• 제목/요약/키워드: Phase-shifted FB-ZVS PWM Converter

Search Result 5, Processing Time 0.019 seconds

A Design of Driving Circuit for Microwave oven using Phase-shifted FB-ZVS PWM Switching (Phase-shifted FB-ZVS PWM 스위칭을 이용한 Micorwave oven 구동회로 설계)

  • 이완윤;정교범;신판석
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.6 no.3
    • /
    • pp.265-272
    • /
    • 2001
  • The traditional 60[Hz] power supply for during magnetron in microwave oven has disadvantages of heavy weight and low efficiency due to 60[Hz] High Voltage Transformer(HVT), capacitor and th phase control of thyristors. To alleviate these disadvantages, this paper proposes a 20[kHz] phase-shifted Full-Bridge(FB) Zero-Voltage-Switched(ZVS) PWM converter for driving a 600[W] magnetron in an 1[kW] microwave oven. The proposed converter has advantages of light weight and high power density.

  • PDF

A Design of Phase-Shifted FB-ZVS PWM Converter for Driving Magnetron and Its Average Anode Current Controller

  • Lee Wan-Yun;Chung Gyo-Bum;Shin Pan-Seok
    • Proceedings of the KIPE Conference
    • /
    • 2001.10a
    • /
    • pp.140-145
    • /
    • 2001
  • This paper proposes to use a 20[kHz] phase­shifted Full-Bridge (FB) Zero-Voltage-Switched (ZVS) PWM converter in order to drive a 600[W] magnetron, and analyzes the operational modes in a switching period. Additionally, the controller of the average anode current is designed. Simulation studies and experiments verify that the proposed converter and the average anode current controller shows good performance to drive the magnetron.

  • PDF

Phase-shifted PWM FB DC/DC Converter with ZVS Method (ZVS 기법을 사용한 위상제어 PWM FB DC/DC 컨버터)

  • Kim, Sung-Chul;Kwon, Soon-Kurl;Kye, Moom-Ho;Joe, Kee-Yeon
    • Proceedings of the KIEE Conference
    • /
    • 1996.07a
    • /
    • pp.392-394
    • /
    • 1996
  • This paper is to describe how to apply the Phase-shifted Full Bridge 100kHz high frequency soft-switching PWM method to 48[V], 200[A] DC/DC converter. The soft-switching is achieved from light load to full load by using phase-shifted zero voltage switching method with additional capacitors besides the MOSPET's of the right leg even though the leakage inductance of high frequency transformer is designed small. This method can reduce the switching tosses, EMI problems, and increase the effective duty. Also, this paper includes the simulation, analysis, and experiment results of the DC/DC converter unit.

  • PDF

A Design of PS FB-ZVS PWM Converter with Magnetron Load (부하특성을 고려한 마그네트론 구동용 PS FB-ZVS PWM 컨버터의 설계)

  • Lee Wan-Yun;Chung Gyo-Bum;Shin Pan-Seok
    • Proceedings of the KIPE Conference
    • /
    • 2001.07a
    • /
    • pp.360-363
    • /
    • 2001
  • The conventional 60(Hz) power supply for driving magnetron in microwave oven has disadvantages of heavy weight and low efficiency due to 60(Hz) High Voltage Transformer(HVT), capacitor and the phase control of thyristors with open-loop controller. To alleviate these disadvantages, this paper proposes a 20(kHz) phase-shifted(PS) Full-Bridge(FB) Zero- voltage-Switched(ZVS) PWM converter to drive a 600(W) magnetron in an 1(kW) microwave oven and to control the average anode current.

  • PDF

An auxiliary circuit for reducing loss during free-wheeling interval in FB ZVT PWM converter (FB ZVT PWM 컨버터의 환류구간 손실저감을 위한 보조회로)

  • 윤창선;김병철;김광헌
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.5 no.3
    • /
    • pp.209-214
    • /
    • 2000
  • In this paper, we propose a FB ZVT(full bridge zero voltage transition) PWM OC~OC converter which uses a a saturable reactor, instead of two additional switches, to achieve zero voltage switching. The conventional h high frequency phase shifted FB ZVT PWM OC-OC converter has a disadvantage that a circulating current f flows through high frequency transformer and switching devices during the free-wheeling interval. Due to this c circulating current, conduction loss increases. In order to reduce such the loss as this, we propose circuit of r reducing conduction loss at the secondary side of transformer. The operation principles are explained in detail a and the several interesting simulations and experimental results verify the validity of the proposed circuit.

  • PDF