• Title/Summary/Keyword: Phase-control

Search Result 7,247, Processing Time 0.039 seconds

Implementation of Phase Shift Full-Bridge PWM Converter Using DSP (DSP를 이용한 위상 천이 풀-브릿지 컨버터의 디지털 제어기 구현)

  • Lim Soo-Hyun;Lim Jeong-Gyu;Chung Se-Kyo;Lee Hyun-Woo
    • Proceedings of the KIPE Conference
    • /
    • 2006.06a
    • /
    • pp.137-139
    • /
    • 2006
  • This paper present an implementation of digital control system for a phase-shift full-bridge converter using a digital signal processor. The digital control of phase-shift full-bridge converter provides many advantageous of easily generating various phase-shift timing and implementing a complex voltage and current control algorithm. The digital controller is implemented using the DSP TMS320F2812 and the converter and controller operation is proved through the experimental results.

  • PDF

Modified RCC MPPT Method for Single-stage Single-phase Grid-connected PV Inverters

  • Boonmee, Chaiyant;Kumsuwan, Yuttana
    • Journal of Power Electronics
    • /
    • v.17 no.5
    • /
    • pp.1338-1348
    • /
    • 2017
  • In this study, a modified ripple correlation control (RCC) maximum-power point-tracking (MPPT) algorithm is proposed for a single-stage single-phase voltage source inverter (VSI) on a grid-connected photovoltaic system (GCPVS). Unlike classic RCC methods, the proposed algorithm does not require high-pass and low-pass filters or the increment of the AC component filter function in the voltage control loop. A simple arithmetic mean function is used to calculate the average value of the photovoltaic (PV) voltage, PV power, and PV voltage ripples for the MPPT of the RCC method. Furthermore, a high-accuracy and high-precision MPPT is achieved. The performance of the proposed algorithm for the single-stage single-phase VSI GCPVS is investigated through simulation and experimental results.

A Basic Study for the Control Circuit of 2-phase 8-pole HB type Linear Pulse Motor (2상 8극 HB형 리니어펄스모터의 제어회로구성을 위한 기초연구)

  • Kim, Sung-Hun;Kim, Il-Jung;Lee, Eun-Woong
    • Proceedings of the KIEE Conference
    • /
    • 1994.07a
    • /
    • pp.135-137
    • /
    • 1994
  • In this paper, step response, speed, maximum frequency characteristics of 2-phase, 8-pole, HB type, prototype linear pulse motor(LPM) were investigated with the open loop control system(OLCS) being attached to the LPH. In this experiment, both 1-phase and 1-2 phase excitation types were adopted and microcomputer was used in deal with the data. The results point to some directions for the improvement of the open loop control system.

  • PDF

Instantaneous Control of Single Phase AC/DC PWM Parallel Converters (단상 AC/DC PWM 병렬 컨버터의 순시 제어)

  • Won June-Hee;Cheong Dal-Ho;Oh Jae-Yoon
    • Proceedings of the KIPE Conference
    • /
    • 2001.07a
    • /
    • pp.356-359
    • /
    • 2001
  • In this paper, the new control algorithm is proposed that compensates instantaneously the active and reactive components of the input currents by the synchronous d,q axis conversion of a single-phase current in controlling the single-phase AC/DC parallel converters for a high speed train. The leakage inductance of a transformer was used as a boost inductance and the ripple of a transformer's primary current was reduced considerably by the parallel operation of the two converters with a proper switching phase-shift. The stable and fast control response characteristic is certificated by a simulation.

  • PDF

Improvement Control of Power Quality of Grid-Tied PCS for Fuel Cell System (연료전지용 계통연계형 전력변환기의 전력품질개선제어)

  • Lee, J.M.;Jung, S.M.;Suh, I.Y.;Han, S.H.;Mok, H.S.;Choe, G.H.
    • Proceedings of the KIPE Conference
    • /
    • 2007.07a
    • /
    • pp.77-79
    • /
    • 2007
  • The phase angle of the utility voltage is used in current control of grid-tied fuel cell power converter. Therefore if the detection of phase angle is a problem, Current control is affected by the distorted phase angle. This paper presents a problem of synchronous reference frame PLL algorithm for single-phase systems and proposes compensated synchronous reference frame PLL algorithm. The proposed method helps power quality improvement of grid-tied fuel cell power converter under distorted utility conditions. Simulation and experimental results are presented to demonstrate the validity of the proposed method.

  • PDF

Study on Switching Angle Characteristic for Optimal Driving Condition of SRM (SRM의 최적운전을 위한 스위칭각 선정에 관한 연구)

  • Oh Seok-Gyu;Lee Sang-Hoon;Kim Chang-Sub;Ahn Jin-Woo
    • Proceedings of the KIPE Conference
    • /
    • 2001.07a
    • /
    • pp.231-234
    • /
    • 2001
  • The torque of SRM depends on phase current and the derivative of inductance. But the inductance of SRM is nonlinearly changed according to rotor position angle and phase current because of saturation in magnetic circuit. Therefore this has a concern in torque ripple and speed variation, and it is difficult to control the desired torque The torque of SRM depends on phase current and the derivative of inductance. But the inductance of SRM is nonlinearly changed according to rotor position angle and phase current because of saturation in magnetic circuit, and it is difficult to control the desired torque. This paper proposes an optimization control scheme by adjusting both the turn-on and turn-off angle according to high efficiency points which are simulated by GA-Neural Network, which is used to simulate the reasonable switching angle which is nonlinearly varied with rotor speed and load.

  • PDF

Assessment of Three-Phase Actuated Signal Operation at Diamond Interchanges (다이아몬드 인터체인지의 3 현시 신호운영 평가)

  • 이상수
    • Proceedings of the KOR-KST Conference
    • /
    • 2002.02a
    • /
    • pp.143-159
    • /
    • 2002
  • The performance of two single-barrier three-phase actuated control systems at diamond interchanges was evaluated for various traffic conditions. To emulate the actuated signal control, hardware-in-the-loop system combined with CORSIM simulation program was used. Two performance measures, average delay and total stops, were used for the evaluation process. Results showed that the two three-phase systems gave similar performance in terms of average delay, but not stops. The delay performance of each phasing system was generally dependent on the traffic pattern and ramp spacing. The total stops decreased as the spacing increased, and it was the most sensitive variable that can differentiate between the two three-phase systems. It was also shown that the hardware-in-the-loop control could provide a good method to overcome the limitations of current simulation technology.

  • PDF

Active Control of Flame Oscillation in Lean Premixed Burners by Phase-Controlled Sound Waves

  • Hoshida, Yoshiteru;Inokuchi, Yuzo;Yamasaki, Nobuhiko
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2008.03a
    • /
    • pp.606-611
    • /
    • 2008
  • The objective of the present study is to actively control the flame oscillation in the experimental lean premixed methane burner by the phase-controlled sound waves. The authors propose the methodology of generating the phase-controlled sound waves by directly sensing the preferential frequency and generating the sensor-triggered sound waves with fixed optimum phase difference with the flame oscillation. The real-time controller is implemented in the present study, and the combustion noise reduction is achieved. The reduction is 20dB at peak frequency and 13dB in the OASPL.

  • PDF

Analytical and Experimental Validation of Parasitic Components Influence in SiC MOSFET Three-Phase Grid-connected Inverter

  • Liu, Yitao;Song, Zhendong;Yin, Shan;Peng, Jianchun;Jiang, Hui
    • Journal of Power Electronics
    • /
    • v.19 no.2
    • /
    • pp.591-601
    • /
    • 2019
  • With the development of renewable energy, grid-connected inverter technology has become an important research area. When compared with traditional silicon IGBT power devices, the silicon carbide (SiC) MOSFET shows obvious advantages in terms of its high-power density, low power loss and high-efficiency power supply system. It is suggested that this technology is highly suitable for three-phase AC motors, renewable energy vehicles, aerospace and military power supplies, etc. This paper focuses on the SiC MOSFET behaviors that concern the parasitic component influence throughout the whole working process, which is based on a three-phase grid-connected inverter. A high-speed model of power switch devices is built and theoretically analyzed. Then the power loss is determined through experimental validation.

An Experimental Study on the Prediction Control Technique for a Magnetic Bearing (자기베어링 예측 제어 기법의 실험적 연구)

  • Kim, Chae Sil;Jung, Hoon Hyung;Shin, Min Jae
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.31 no.2
    • /
    • pp.99-104
    • /
    • 2014
  • Active vibration control methods are required in the high speed rotor systems supported by magnetic bearings. A prediction control technique is one of the control methods. Gain and phase angle are primarily chosen with analyzing the responses for a certain rotor speed. The feasibility of this technique has been reported for only analytical simulations. Therefore this paper constructs the test rig supported by ball bearings with a magnetic bearing type actuator and develops a prediction control system by using LabVIEW and Compact RIO. Finally as rotating speeds are modulated, the gains and phase angles for the speeds are determined with vibration control of the test rig. This leads that the prediction control technique may be applied to the rotor system with the magnetic bearing.