• Title/Summary/Keyword: Phase-control

Search Result 7,225, Processing Time 0.035 seconds

Neutral Point Voltage Control for Grid-Connected Three-Phase Three-Level Photovoltaic Inverter (계통연계형 3상 3레벨 태양광 인버터의 중성점 전압제어)

  • Park, Woonho;Yang, Oh
    • Journal of the Semiconductor & Display Technology
    • /
    • v.14 no.4
    • /
    • pp.72-77
    • /
    • 2015
  • Three-level diode clamped multilevel inverter, generally known as neutral point clamped (NPC) inverter, has an inherent problem causing neutral point (NP) potential variation. Until now, the NP potential problem of variation has been investigated and lots of solutions have also been proposed. This paper presents a neutral point voltage control technology using the anti-windup PI controller and offset technology of PWM (Pulse Width Modulation) to control the variation of NPC 3-phase three-level inverter neutral point voltage. And the proposed algorithm is tested and verified using a PLL (Phase Locked Loop) in order to synchronize the phase voltage from the line voltage of grid. It significantly improves the voltage balancing under a solar fluctuation conditions of the inverter. Experimental results show the good performance and effectiveness of the proposed method.

A New Control of Three-Phase PWM Rectifier with Single Current Sensor (단일 전류 센서를 사용한 3상 PWM 정류기의 새로운 제어)

  • Lee, U-Cheol;Hyeon, Dong-Seok;Lee, Taek-Gi
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.48 no.8
    • /
    • pp.440-447
    • /
    • 1999
  • This paper proposes a control method for three-phase PWM rectifier with only single current sensor in DC link side. A PWM modulation strategy for reconstructing three phase currents from the DC link current is given. The states of the retifier switch are modified so that all phase currents can be reconstructed in a switching period although one or two of active vectors is applied only for a short time. Therefore, a new current control using an adjustment scheme of the modulation signal for three-phase PWM rectifier will be discussed, and verified the experimental results.

  • PDF

Development of Advanced Phase-Shedding Control Algorithm for DVR Power Supply (DVR 전원용 진보된 Phase-Shedding 제어 알고리즘 개발)

  • Lee, Jun-Young;Kim, Cheol-Min;Kim, Jong-Soo
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.26 no.6
    • /
    • pp.397-403
    • /
    • 2021
  • In this paper, phase shedding algorithm that measuring to converter's input and output parameter during real-time to control the number of driving converters is proposed. The proposed phase-shedding algorithm drives the DVR power supply with the optimal converter's combination without the loss calculation curve and the lookup table in which the efficiency is measured in advance. The proposed algorithm was implemented through a digital controller and verified in a two-modular LLC converter with a single rated power of 60 Win a 120 W DVR power supply system. Experimental results are presented to prove the validity of the proposed algorithm.

Advanced Control of Three-Phase Four-Wire Inverters using Feedback Linearization under Unbalanced and Nonlinear Load Conditions (불평형 비선형 부하시 궤환선형화 기법을 이용한 3상 4선식 인버터의 제어 성능 개선)

  • Vo, Nguyen Qui Tu;Lee, Dong-Choon
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.18 no.4
    • /
    • pp.333-341
    • /
    • 2013
  • In this paper, a feedback linearization control is proposed to regulate the output voltages of a three-phase four-wire inverter under the unbalanced and nonlinear load conditions. First, the nonlinear model of system including the output LC filters is derived in the d-q-0 synchronous reference frame. Then, the system is linearized by the multi-input multi-output feedback linearization. The tracking controllers for d-q-0-components of three-phase line-to-neutral load voltages are designed by linear control theory. The experimental results have shown that the proposed control method gives the good performance in response to the load conditions.

Improved the Noise Immunity of Phase-Locked Loop

  • Intachot, Terdsak;Panaudomsup, Sumit;Prempraneerach, Yothin
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2003.10a
    • /
    • pp.1643-1647
    • /
    • 2003
  • This paper, we propose a new high noise immunity phase-locked loop(PLL) which can suppress the high incident noise coupling with large amplitude and long period to the input frequency of PLL and keeps constant frequency and phase of the VCO output for providing the high stability distribution clock pulse.

  • PDF

A Precision Voltage Control of Single Phase PWM Inverters Using PLL Compensation Loop (PLL보상루프를 이용할 단상 PWM 인버터의 정밀 전압제어)

  • Chung Se-Kyo;Choi Seong-Rak;Choi Jin-Woo
    • Proceedings of the KIPE Conference
    • /
    • 2001.12a
    • /
    • pp.185-189
    • /
    • 2001
  • This paper presents a precision voltage control technique of a single phase PWM inverter for a constant voltage and constant frequency(CVCF) applications. The proposed control employes a PLL compensating loop which minimize the steady state error and phase delay. The computer simulation and experiment are carried out for the actual single phase PWM inverter and the results well demonstrate the effectiveness of the proposed control.

  • PDF

Robust PID controller design to ensure specified Gain and Phase Margin (이득여유와 위상여유를 보강하는 견실한 PID 제어기 설계)

  • Cho, Joon-Ho;Ryu, Young-Guk;Choi, Jung-Nae;Hwang, Hyung-Soo
    • Proceedings of the KIEE Conference
    • /
    • 2000.11d
    • /
    • pp.632-634
    • /
    • 2000
  • The robust design of controllers to ensure gain and phase margin is can be use approximation of arctan function. In this paper, We proposed a tuning algorithm PID controllers based on specified gain and phase margin by a new approximation of arctan function. This method have linear interpolation equations of two arctan interval instead of one arctan interval of arctan(x). It is shown that the frequency response of this method was to ensure specified gain and phase margin.

  • PDF

Control Algorithm for 4-Switch Inverter of 3-Phase SRM (3상 SRM 구동용 4-스위치 인버터 PWM 제어 알고리즘)

  • Yoon, Yong-Ho;Lee, Byoung-Kuk;Won, Chung-Yuen
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.58 no.3
    • /
    • pp.303-309
    • /
    • 2009
  • Switched Reluctance Motor(SRM) has become popular for industrial application, particularly for low medium drives due to the advantages of SRM over the other ac motors: SRM can be manufactured with low cost because it has a simple structure. But, asymmetric bridge converter that generally is used for driving requires two discrete switching devices and freewheeling diodes per phase, and cause the SRM drives to be complicated and to increase the cost of overall system. Therefore, this paper suggests a new type of 4-switch converter for SRM. 4-switch converter topology is studied to provide a possibility for the realization of low cost 3-phase SRM drive system. For effective utilization of the developed system, a new current control algorithm is designed and implemented to produce the desired dynamic performance. With the developed power conversion circuit and control scheme, it is expected that the proposed system can be widely used in commercial applications with reduced system cost.

DCM Frequency Control Algorithm for Multi-Phase DC-DC Boost Converters for Input Current Ripple Reduction

  • Joo, Dong-Myoung;Kim, Dong-Hee;Lee, Byoung-Kuk
    • Journal of Electrical Engineering and Technology
    • /
    • v.10 no.6
    • /
    • pp.2307-2314
    • /
    • 2015
  • In this paper, a discontinuous conduction mode (DCM) frequency control algorithm is proposed to reduce the input current ripple of a multi-phase interleaved boost converter. Unlike conventional variable duty and constant frequency control, the proposed algorithm controls the switching frequency to regulate the output voltage. By fixing the duty ratio at 1/N in the N-phase interleaved boost converter, the input current ripple can be minimized by ripple cancellation. Furthermore, the negative effects of the diode reverse recovery current are eliminated because of the DCM characteristic. A frequency controller is designed to employ the proposed algorithm considering the magnetic permeability change. The proposed algorithm is analyzed in the frequency domain and verified by a 600 W three-phase boost converter prototype that achieved 57% ripple current reduction.

Parameters Estimation Characteristics of Five-Phase Squirrel-Cage Induction Motor within Over Current Load (과전류 부하에서 5상 농형 유도전동기의 정수 특성)

  • Kim, Min-Huei
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.29 no.7
    • /
    • pp.38-46
    • /
    • 2015
  • This paper propose a variable parameter estimations for variable over current load of five-phase squirrel-cage induction motor(IM) to servo control system. In order to high performance control of AC motor using a field oriented control(FOC) and direct torque control(DTC) algorithm, there are required precise motor parameters for slip calculation, flux observer, controller gain, torque command of current components, rotor position, speed estimation, and so on. We are suggest a analyzed estimation results of the motor parameters that developing five-phase squirrel-cage IM have a stator of concentrated winding for experimental within variable over current load at rated input frequency. There are results of stator winding measurement, no-load test, locked-rotor test, variable over current load test, and estimated parameters of equivalent circuits using manufactured experimental apparatus by IEEE Standard Test Procedure for Polyphase Induction Motors and Generators 112-2004.