• Title/Summary/Keyword: Phase-Average

Search Result 2,212, Processing Time 0.03 seconds

Measuring the Average Torque according to Exciting Region of Single Phase SRM (단상 SRM의 여자구간에 따른 평균 토크 측정)

  • Kim Yong-Heon;Lee Eun-Woong;Lee Jong-Han;Lee Hyeon-Woo;Kim Jun-ho
    • Proceedings of the KIEE Conference
    • /
    • summer
    • /
    • pp.989-991
    • /
    • 2004
  • There are many elements that affect the average torque of the single phase SRM. It is related with the stator and rotor pole arcs, the dwell angle of the exciting current, the turn on/off angle, etc., Most of all, the turn on/off angle is affect the design procedure of the driving and control circuit. So, in this study, it is intend to analyze the effect that the variations of the turn on/off angle affects the average torque. and then this analyses will be used to design the control driver of the single phase SRM.

  • PDF

A study to 3D dose measurement and evaluation for Respiratory Motion in Lung Cancer Stereotactic Body Radiotherapy Treatment (폐암의 정위적체부방사선치료시 호흡 움직임에 따른 3D 선량 측정평가)

  • Choi, Byeong-Geol;Choi, Chang-Heon;Yun, Il-Gyu;Yang, Jin-Seong;Lee, Dong-Myeong;Park, Ju-Mi
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.26 no.1
    • /
    • pp.59-67
    • /
    • 2014
  • Purpose : This study aims to evaluate 3D dosimetric impact for MIP image and each phase image in stereotactic body radiotherapy (SBRT) for lung cancer using volumetric modulated arc therapy (VMAT). Materials and Methods : For each of 5 patients with non-small-cell pulmonary tumors, a respiration-correlated four-dimensional computed tomography (4DCT) study was performed. We obtain ten 3D CT images corresponding to phases of a breathing cycle. Treatment plans were generated using MIP CT image and each phases 3D CT. We performed the dose verification of the TPS with use of the Ion chamber and COMPASS. The dose distribution that were 3D reconstructed using MIP CT image compared with dose distribution on the corresponding phase of the 4D CT data. Results : Gamma evaluation was performed to evaluate the accuracy of dose delivery for MIP CT data and 4D CT data of 5 patients. The average percentage of points passing the gamma criteria of 2 mm/2% about 99%. The average Homogeneity Index difference between MIP and each 3D data of patient dose was 0.03~0.04. The average difference between PTV maximum dose was 3.30 cGy, The average different Spinal Coad dose was 3.30 cGy, The average of difference with $V_{20}$, $V_{10}$, $V_5$ of Lung was -0.04%~2.32%. The average Homogeneity Index difference between MIP and each phase 3d data of all patient was -0.03~0.03. The average PTV maximum dose difference was minimum for 10% phase and maximum for 70% phase. The average Spain cord maximum dose difference was minimum for 0% phase and maximum for 50% phase. The average difference of $V_{20}$, $V_{10}$, $V_5$ of Lung show bo certain trend. Conclusion : There is no tendency of dose difference between MIP with 3D CT data of each phase. But there are appreciable difference for specific phase. It is need to study about patient group which has similar tumor location and breathing motion. Then we compare with dose distribution for each phase 3D image data or MIP image data. we will determine appropriate image data for treatment plan.

Analysis and Design of a 3-phase Series-Resonant type High Voltage Capacitor Charger (3상 직렬공진형 고전압 커패시터 충전기의 해석 및 설계)

  • Lee, Byungha;Park, Sangeun;Cha, Hanju
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.62 no.4
    • /
    • pp.510-516
    • /
    • 2013
  • This paper suggests a 3-phase series-resonant type high voltage capacitor charger for an EML pulsed power system. The operating principle on the charger is explained by an equivalent circuit. Additionally, we analyze the charging characteristic in one discontinuous conduction mode and three continuous conduction modes. The analysis shows that the resonant current per phase is two thirds of the 3-phase charger's average charging current and one third of the single-phase charger's average charging current with the same capacity. We suggest a design method of the 3-phase capacitor charger in each operational mode and present an example of 3.5 kW capacitor charger at ${\omega}_s=0.33{\omega}_r$. The 3.5 kW 3-phase capacitor charger prototype is assembled with a TI28335 controller and a 40 kJ, 7 kV capacitor. The design rules based on the analysis are verified by experiment.

The Average Power Algorithm of Active Power Filters for Asymmetrical Three-Phase Three-Wire Power System (비대칭 3상 3선 전원 시스템을 위한 능동전력필터의 평균전력 알고리즘)

  • 정영국;김우용;임영철
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.6 no.6
    • /
    • pp.514-524
    • /
    • 2001
  • Conventional average power theory has been used to design and control active power filters But compensating reference currents of active power filters calculated by conventional average power theory are definitively influenced by three phase source voltage conditions such as unbalance or distortion. This paper presents a new average power algorithm for active power filters which can detect symmetrically equally active or fundamental reactive currents in each phase based on decomposition of fundamental reactive component and harmonics under unbalanced power conditions. The effectiveness of the proposed algorithm is demonstrated by MATLAB/SIMULINK simulation and experimental results for a three wire distribution system with 15% unbalanced source voltages.

  • PDF

Effects of protease enzyme supplementation in weanling pigs' diet with different crude protein levels on growth performance and nutrient digestibility

  • Olivier, Munezero;In Ho, Kim
    • Journal of Animal Science and Technology
    • /
    • v.64 no.5
    • /
    • pp.854-862
    • /
    • 2022
  • The purpose of this study is to determine the impact of different levels of crude protein (CP) diets supplemented with dietary protease on the growth performance and nutrient digestibility of the weanling pigs. In a 5-week study, 100 crossbred ([Landrace × Yorkshire] × Duroc) of weaner pigs that have an average initial body weight (BW) of 7.17±1.06 kg were assigned to one of four dietary treatments with 5 replications and 5 pigs (3 gilts and 2 castrated male pigs) per pen in a randomized complete block design. The dietary treatments were as follows: Phase 1: CON: basal diets (20.60% CP); low protein (LP): CON - 0.30% CP; PLP1: (CON - 0.30% CP) + 0.05% protease; PLP2: (CON - 0.50% CP) + 0.05% protease. Phase 2: CON: basal diets (18.88% CP); LP: CON - 0.30% CP; PLP1: (CON - 0.30% CP) + 0.05% protease; PLP2: (CON - 0.50% CP) + 0.05% protease. The addition of protease to low CP diets significantly increased the feed conversion ratio (FCR) (p = 0.039), BW (p = 0.046), average daily gain (ADG) (p = 0.049), and average daily feed intake (ADFI) tended to increase (p = 0.053) in the young pigs during phase 1. However, FCR tended to increase throughout the experiment but did not change during phase 2, whereas BW, ADG, and ADFI stayed unchanged throughout phase 2 and overall. There was no significant difference in dry matter, nitrogen (N), and gross energy of nutrient digestibility in all phases and overall in weaned pigs with low CP when protease was fed. In contrast, adding protease to the low CP diets increased the tendency of N digestibility (p = 0.059) during phase 1. It is concluded that dietary protease supplementation tended to increase N retention during the first phase of the weaning period, hence increasing piglet performance.

Effect of reducing dietary crude protein level on growth performance, blood profiles, nutrient digestibility, carcass traits, and odor emissions in growing-finishing pigs

  • Aaron Niyonsaba;Xing Hao Jin;Yoo Yong Kim
    • Animal Bioscience
    • /
    • v.36 no.10
    • /
    • pp.1584-1595
    • /
    • 2023
  • Objective: This study was conducted to evaluate the effect of a low-protein diet on growth performance, carcass traits, nutrient digestibility, blood profiles, and odor emissions in growing-finishing pigs. Methods: A total of 126 crossbred pigs ([Yorkshire×Landrace]×Duroc) with an average body weight (BW) of 38.56±0.53 kg were used for a 14-week feeding trial. Experimental pigs were allotted to one of 6 treatments in 3 replicates of 7 pigs per pen in a randomized complete block design. Pigs were fed each treatment diet with different levels of crude protein (CP). Phase 1 (early growing): 14%, 15%, 16%, 17%, 18%, 19%; phase 2 (late growing): 13%, 14%, 15%, 16%, 17%, 18%; phase 3 (early finishing): 12%, 13%, 14%, 15%, 16%, 17%; phase 4 (late finishing): 11%, 12%, 13%, 14%, 15%, 16%. All experimental diets in each phase were contained the same concentration of lysine (Lys), methionine (Met), threonine (Thr), and tryptophan (Trp). Results: Over the entire experimental period, there was no significant difference in BW, average daily feed intake, and gain-to-feed ratio among all treatments (p>0.05), but a quadratic effect (p = 0.04) was observed in average daily gain (ADG) during the late finishing phase with higher ADG in Group D. Blood urea nitrogen concentration linearly increased with an increase in dietary CP levels (p<0.01). Regarding nutrient digestibility, excreted nitrogen in urine and feces and nitrogen retention linearly increased as the CP level increased (p<0.01). A linear effect was observed with increasing CP levels in amines, ammonia, and hydrogen sulfide in odor emissions (p<0.01). No significant effects were observed in the measurements of carcass traits and meat characteristics (p>0.05). Conclusion: In phase feeding, reducing the CP level to 14% in early-growing pigs, 13% in late-growing pigs, 12% in early-finishing pigs, and 11% in late-finishing pigs is recommended.

Counter-Current Air-Water Flow in Narrow Rectangular Channels With Offset Strip Fins

  • Kim, Byong-Joo;Sohn, Byung-Hu;Koo, Kee-Kahb
    • Journal of Mechanical Science and Technology
    • /
    • v.17 no.3
    • /
    • pp.429-439
    • /
    • 2003
  • Counter-current two-phase flows of air- water in narrow rectangular channels with offset strip fins have been experimentally investigated in a 760 mm long and 100 mm wide test section with 3.0 and 5.0 mm gap widths. The two-phase flow regime, channel-average void fractions and two-phase pressure gradients were studied. Flow regime transition occurred at lower superficial velocities of air than in the channels without fins. In the bubbly and slug flow regimes, elongated bubbles rose along the subchannel formed by fins without lateral movement. The critical void fraction for the bubbly-to-slug transition was about 0.14 for the 3 mm gap channel and 0.2 for the 5 mm gap channel. respectively. Channel-average void fractions in the channels with fins were almost the same as those in the channels without fins. Void fractions increased as the gap width increased, especially at high superficial velocity of air. The presence of fins enhanced the two-phase distribution parameter significantly in the slug flow, where the effect of gap width was almost negligible. Superficial velocity of air dominated the two-phase pressure gradients. Liquid superficial velocity and channel gap width has only a minor effect on the pressure gradients.

Parallel Operation of Three-Phase Bi-Directional Isolated Interleaved DC-DC Converters for The Battery Charge/Discharge System (배터리 충·방전기 시스템에 적용되는 3상 양방향 절연형 인터리브드 DC-DC 컨버터의 병렬운전)

  • Jo, Hyunsik;Lee, Jaedo;Cha, Hanju
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.19 no.1
    • /
    • pp.15-22
    • /
    • 2014
  • Recently, parallel operation of dc-dc converters has been widely used in distributed power systems. In this paper, a control method to achieve parallel operation of three-phase bi-directional isolated interleaved dc-dc converters is discussed for the battery charging and discharging system which consists of the 32 battery charger/dischargers and two three-phase bi-directional isolated interleaved dc-dc converters. In the boost mode, the battery energy is delivered to the grid, whereas the grid energy is transferred to the battery in the buck mode operation. The average current sharing control method is employed to obtain an equal conducting of each phase current in the three-phase dc-dc converter. By using the proposed method, the imbalance factor is gratefully reduced from 8 percent to 1 percent. Two 2.5kW three-phase bi-directional dc-dc converter prototype have been built and the proposed method has been verified through experiments.

PIV Measurement of Circular Cylinder Wake Using Vortex Tracking Phase-Average Technique (와추적 위상평균 기법을 이용한 원주후류의 PIV측정)

  • Kim, Gyeong-Cheon;Yun, Sang-Yeol;Kim, Sang-Gi;Bu, Jeong-Suk
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.25 no.7
    • /
    • pp.915-922
    • /
    • 2001
  • A new phase-average technique using instantaneous velocity fields obtained by a PIV method has been developed. The technique tracks vorticity centers and estimates the value of circulation for a chosen domain. The locations of vortex-centers and the magnitudes of circulation are matched together then showing a sine wave feature due to the periodic vortex shedding from the circular cylinder. Ensemble averaged and phase averaged velocity fields are successfully measured for the circular cylinder wake where Reynolds number is 3900 based on free stream velocity and cylinder diameter. The convection velocities of the vortices center and the vortex shedding frequency were measured by a single hot-wire probe.

Experimental Study on Two-Phase Flow Parameters of Subcoolet Boiling in Inclined Annulus

  • Lee, Tae-Ho;Kim, Moon-Oh;Park, Goon-Cherl
    • Nuclear Engineering and Technology
    • /
    • v.31 no.1
    • /
    • pp.29-48
    • /
    • 1999
  • Local two-phase flow parameters of subcooled flow boiling in inclined annulus were measured to investigate the effect of inclination on the internal flow structure. Two-conductivity probe technique was applied to measure local gas phasic parameters, including void fraction, vapor bubble frequency, chord length, vapor bubble velocity and interfacial area concentration. Local liquid velocity was measured by Pilot tube. Experiments were conducted for three angles of inclination; 0$^{\circ}$(vertical), 30$^{\circ}$, 60$^{\circ}$. The system pressure was maintained at atmospheric pressure. The range of average void fraction was up to 10% and the average liquid superficial velocities were less than 1.3 m/sec. The results of experiments showed that the distributions of two-phase How parameters were influenced by the angle of channel inclination. Especially, the void fraction and chord length distributions were strongly affected by the increase of inclination angle, and flow pattern transition to slug flow was observed depending on the How conditions. The profiles of vapor velocity, liquid velocity and interfacial area concentration were found to be affected by the non-symmetric bubble size distribution in inclined channel. Using the measured distributions of local phasic parameters, an analysis for predicting average void fraction was performed based on the drift flux model and flowing volumetric concentration. And it was demonstrated that the average void fraction can be more appropriately presented in terms of flowing volumetric concentration.

  • PDF