• Title/Summary/Keyword: Phase-Average

Search Result 2,212, Processing Time 0.029 seconds

Thermal Decomposition and Sintering Characteristics of Cr-Deficient $(La,Ca)CrO_3$ (크롬부족 (란탄, 칼슘)크로마이트의 열분해과정 및 소결특성)

  • 이상기;조성걸
    • Journal of the Korean Ceramic Society
    • /
    • v.34 no.11
    • /
    • pp.1182-1186
    • /
    • 1997
  • La0.8Ca0.2Cr0.98O3 powder was prepared using the modified Pechini process. Various crystalline phases formed during thermal decomposition were investigated. (La,Ca)CrO4 phase, first formed from the precursor, was transformed to (La,Ca)CrO3 and CaCrO4 above 80$0^{\circ}C$, which remained up to 110$0^{\circ}C$. However, only (La,Ca)CrO3 phase consisting of orthorhombic and intermediate rhombohedral polymorphs was observed after sintering at 125$0^{\circ}C$. The specimens sintered at 140$0^{\circ}C$ exhibited 98% of relative density and rather wide grain size distribution with average grain size of 3-4 ${\mu}{\textrm}{m}$. Densification and grain growth of the specimens observed above 125$0^{\circ}C$ were presumably attributed to liquid phase sintering resulted from melting of Ca3(CrO4)2 phase.

  • PDF

Melting Heat Transfer Characteristics of Plural Phase Change Microcapsules Slurry Having Different Diameters

  • Kim, Myoung-Jun;Kim, Myoung-Hwan
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.28 no.8
    • /
    • pp.1225-1238
    • /
    • 2004
  • The present study has been performed for obtaining the melting heat transfer enhancement characteristics of water mixture slurries of plural microcapsules having different diameters encapsulated with solid-liquid phase change material(PCM) flowing in a pipe heated under a constant wall heat flux condition. In the turbulent flow region, the friction factor of the present PCM slurry was to be lower than that of only water flow due to the drag reducing effect of the PCM slurry. The heat transfer coefficient of the PCM slurry flow in the pipe was increased by both effects of latent heat involved in phase change process and microconvection around plural microcapsules with different diameters. The experimental results revealed that the average heat transfer coefficient of the PCM slurry flow was about 2~2.8 times greater than that of a single phase of water.

Torque Maximization Control of 3-Phase BLDC Motors in the High Speed Region

  • Im, Won-Sang;Kim, Jong-Pil;Kim, Jang-Mok;Baek, Kwang-Ryul
    • Journal of Power Electronics
    • /
    • v.10 no.6
    • /
    • pp.717-723
    • /
    • 2010
  • This paper proposes a new torque control algorithm for BLDC motors to get the maximum torque in the high speed region. The delay of the phase currents is severe due to the stator reactance. The torque fluctuations of BLDC motors increase and the average torque is decreases due to a slow rise in the phase current when compared to the back EMF. In this paper, the phase current of BLDC motors under the high speed condition is analyzed and a torque maximization control is developed on the basis of using numerical analysis. Computer simulations and experimental results show the usefulness of the proposed control algorithm.

A Study on Continuous Control of $1{\Phi}$ Condenser Type Induction Motor using 12 Step PWM 2 Phase Inverter (12 스텝 PWM 2상 인버터를 이용한 콘덴서형 단상 유도전동기의 연속제어 방안에 대한 연구)

  • Oh, Seog-Moon;Lee, Sung-Ryong;Yu, Chul-Ro
    • Proceedings of the KIEE Conference
    • /
    • 1995.07a
    • /
    • pp.227-230
    • /
    • 1995
  • This paper presents continuous control concept of unsymmetrical 2 phase induction machine(I.M.). For 2 phase driving of the unsymmetrical I.M., variable voltage and variable frequency inverter is needed. In this paper, a new 12 step PWM 2 phase inverter was proposed. And then, proposed inverter fed 2 phase driving of unsymmetrical I.M. was studied, expecially on average torque and pulsation torque. This system has merits like higher fundamental component and better harmonic characteristics. The simulation was done on this issue and experimental research is on the way.

  • PDF

Characteristics of Two-Phase Flow in Vertical Pipe (수직관에서의 이상유동 특성)

  • Bae, B.M.;Sim, W.G.
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2004.11a
    • /
    • pp.879-882
    • /
    • 2004
  • Two-phase flow exists in many industrial components. Characteristics of two-phase flow have been studied by many researchers; however, a further study of the two-phase is required for flow-induced vibration. Characteristics of two-phase flow were measured by force sensor at the end of a vertical pipe. The predominant frequency of fluctuation was obtained for various speeds of flow pattern. A correlation to slug frequency for horizontal flow was obtained by Heywood & Richardson (1979), while Legius et al (1997) for vertical flow. A coefficient based on the correlation is estimated and then compared to the existing ones. The existing empirical formulations for average void fraction were proposed by Wallis (1969), Zuber et al (1967) and Ishii (1970). In the present result, flow parameters, such as flow quality and real velocity, are evaluated with void fraction.

  • PDF

Sensorless Control Method of the BLDC Motor Without Neutral Point (중성점을 사용하지 않는 BLDC 전동기 센서리스 제어 기법)

  • Sim, Kwang-Ryeol;An, Jeong-Ryeol
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.61 no.3
    • /
    • pp.111-115
    • /
    • 2012
  • Generally, brushless DC motor(BLDCM) driving system uses hall sensors or encoders as the mechanical position or speed sensor. It is necessary to achieve the informations of rotor position for driving trapezoidal type brushless DC motor without any position sensor. In this paper, the commutation signals are obtained without the motor neutral voltage, multistage analog filters, A/D converters, or the complex digital phase shift circuits which are indispensable in the conventional sensorless control algorithms. In the proposed method, in stead of detecting the zero crossing point of the nonexcited motor back electromagnetic force for the average motor terminal to neutral voltage, the commutation signal are extracted directly from the specific average line to line voltage with low-pass filter, adder and comparators circuit. In contrast to conventional methods, the neutral voltage is not need; therefore, the commutation signals are insensitive to the common mode noise. Moreover, the complex phase shift circuit can be eliminated. The effectiveness of the proposed method is verified through simulation results.

A visual investigation of non-premixed flame behavior under acoustic excitation (음향 가진 하에서 비예혼합 화염거동에 관한 가시화 연구)

  • Lee, Kee-Man;Oh, Sai-Kee
    • Proceedings of the KSME Conference
    • /
    • 2001.06d
    • /
    • pp.871-877
    • /
    • 2001
  • Experimental study was conducted to investigate the effects of axial forcing on the flame structures near the nozzle exit of non-premixed flame. The most notable observation is that the direction of vortical motions is changed at some ranges, according to the increase of excitation amplitude. Especially, the elongation flame and the phenomenon of In-burning are always occurred when the vortical motion turnabout. In an analysis of the flame/flow visualization by means of direct photography and RMS technique, a plausible explanation can be made that above phenomena are related only to the amplitude of phase average velocity between the instantaneous velocity elements of excited flow.

  • PDF

Vibration Analysis of Loudspeaker by Using Electronic Speckle Pattern interferometry (전자 스페클 간섭계에 의한 스피커 진동 해석)

  • 강영준
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.6 no.1
    • /
    • pp.92-99
    • /
    • 1997
  • Nowadays, Electronic Speckle Pattern Interferometry is a well-established measuring technique with a wide range of industrial applications, particularly in the fields of deformation measurement and vibration analysis. Comparing with holographic interferometry, it has some attractive features, which are rapid recording and reconstruction, satisfiable automation etc. The Time-Average ESPI is used to provide vibration mode shape of an object whose vibration amplitude is given as a fringe pattern. Its merit is rapid and simple measurement for vibrating object. However, it is not possible to determine the direction of motions of a point on the object at any given time, because it does not give any information about the phase of vibration. But, Stroboscopic ESPI can measure the amplitude and phase of vibrating surface. In this paper, loudspeakers were tested by these two methods. As a result, we can assume that these techniques will be applied directly in the loudspeaker industry.

  • PDF

Evaluation of Rotary Composting Technique for Animal Wastes

  • Oh, I.H.
    • Agricultural and Biosystems Engineering
    • /
    • v.1 no.1
    • /
    • pp.54-58
    • /
    • 2000
  • In order to investigate the compost process and the evaporating phenomenon, a rotary reversing compost system has been tested in a swine farm. During the summer season, the compost temperature was varied in the range of 50~$60^{\circ}C.$ and the ash content was increased by 12.8 % with the average of 24.7 % at the end of phase. In the winter season, the compost temperature was varied in the range of 40~$57^{\circ}C.$ and the ash content was increased to 8.5 % showing the average of 18 % at the end of phase. In summer, the compost facility could handle all of the animal waste, but it could not handle 1/4~1/3 of the animal excrement during the winter. The required amount of sawdust by this method could be reduced to 1/3 than that of the mixing method at the beginning of compost process.

  • PDF

A Study of Failure Mode for 3 Phase VSI by Power Loss Averaging Technique (전력 손실 평균화 기법에 의한 3상 전압형 인버터의 소손 모드에 관한 연구)

  • Cho, S.E.;Park, S.J.
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.59 no.3
    • /
    • pp.575-580
    • /
    • 2010
  • This paper is to design an optimum power conversion device for the system required for development of a low cost 3-phase power inverter. For this purpose, in order to meet with endurance required by the industry, failure mode is standardized to guarantee lifetime of a power semiconductor by monitoring real time power loss and to facilitate failure mode analysis. As normality of heat loss of a power semiconductor is identified remaining in a certain range by comparing heat rise slope between that is calculated by using average current or average loss and that is measured at a heat sink, its feasibility is confirmed by experiment.