• 제목/요약/키워드: Phase plate

검색결과 733건 처리시간 0.023초

Phase Error due to Polarization Components of the Modified Triangular Interferometer

  • Kim, Soo-Gil
    • Journal of the Optical Society of Korea
    • /
    • 제11권1호
    • /
    • pp.10-17
    • /
    • 2007
  • We need two operation modes to obtain the complex hologram without bias and the conjugate image in the modified triangular interferometer (MTI). To solve the problem, we proposed the optimized MTI with one wave plate, which can obtain cosine and sine functions by the combination of one wave plate and one linear polarizer. In the extraction of phase term using the combination of polarization components, the phase error occurs, and we analyzed such potential phase errors in the optimized MTI.

분리 웨어의 상하 조절과 전형판을 이용한 유기상 원심추출기 개발 (Development of centrifugal extractor for organic phase extraction using a height controlled separation weir and a divert plate)

  • 김영환;윤지섭;정재후;홍동희;박기용
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 1997년도 추계학술대회 논문집
    • /
    • pp.515-518
    • /
    • 1997
  • Resident time of the centrifugal extractor for organic phase extraction using a height controlled separator weir and a divert plate is the important factor that affects significantly the chemical material extraction and the productivity in the chemical and mechanical processes. In this paper, it describes the design of the device for extraction of an organic phase from radioactive wastes, and considers phase separating weir and divert disk, both being designed to be adjustable in their positions, for effectively separating an organic phase. A height-adjustable separating weir unit used for separating the organic phase from the aqueous phase using a phase separating weir and designed to control the height of the separating weir as desired so as to allow the weir to be positioned at a boundary layer between two separated phases. The centrifugal extractor controls satisfactorily the mixed reaction time of two phases within the separator regardless of the variations of the mixing ratio of the two phases and the rotating speed of the extractor, is designed to be adjustable in its position in the vertical direction, thus allowing the user to appropriately select the mixed reaction time of the two phases within the extractor as desired. From development of a centrifugal extractor, it can effectively recover such usable elements, and preferably reducing the output quantity of radioactive wastes.

  • PDF

Wave propagation investigation of a porous sandwich FG plate under hygrothermal environments via a new first-order shear deformation theory

  • Al-Osta, Mohammed A.
    • Steel and Composite Structures
    • /
    • 제43권1호
    • /
    • pp.117-127
    • /
    • 2022
  • This study investigates the wave propagation in porous functionally graded (FG) sandwich plates subjected to hygrothermal environments. A new simple three-unknown first-ordershear deformation theory (FSDT) incorporating an integral term is utilized in this paper. Only three unknowns are used to formulate the governing differential equation by applying the Hamilton principle. The FG layer of the sandwich plate is modeled using the power-law function with evenly distributed porosities to represent the defects of the manufacturing process. The plate is subjected to nonlinear hygrothermal changes across the thickness. The effects of the power-law exponent, core to thickness ratios, porosity volume, and the relations between volume fraction and wave properties of porous FG plate under the hygrothermal environment are investigated. The results showed that the waves' phase velocities increase linearly with the waves number in the FGM plate. The porosity of the FG materials plate has a noticeable impact on the phase velocity when considering the high ratios of the core layer. It has a negligible effect on small core layers. Finally, it is observed that changing temperatures and moistures do not influence the relationship between the power law and the phase velocity.

얇은 판재에서의 초음파 종파속도 측정 (Measurement of the Ultrasonic Longitudinal Wave Velocities in Thin Plate)

  • 안봉영;이승석;이재옥
    • 대한기계학회논문집
    • /
    • 제15권6호
    • /
    • pp.2181-2188
    • /
    • 1991
  • 본 연구에서는 주파수도메인에서의 측정방법중 진폭 스펙트럼 방법에 대한 이 론적 배경을 알아보고, 얇은 두께의 재료에 적용한 측정결과를 보이고자 하며, 비교적 두께가 두꺼운 재료에서의 측정결과를 위상 스펙트럼 방법으로의 측정 결과와 비교하 여 측정의 정확성을 서로 비교하였다.

피스톤 펌핑 위상이 텐덤형 사판식 액셜 피스톤 펌프의 진동, 소음에 미치는 영향에 관한 연구(2) (A Study on Effects of Piston Pumping Phase on Vibration and Noises of Tandem Swash Plate Type Axial Piston Pump(2))

  • 박성환;이진걸
    • 한국정밀공학회지
    • /
    • 제16권12호
    • /
    • pp.31-39
    • /
    • 1999
  • Previous researches and experiments have already verified that the primary noise source of high pressure tandem axial thpe piston pump is fluid-borne noise from the process of oil distribution between the kidney-shaped port and valve plate. So, many researchers have improved pressure gradients and reduced sound levels by applying pre-compression and pre-decompression metering grooves to valve plate. In practice however, the sound level of th high pressure tandem axial type piston pump is still undesirable. This paper testified the effect of pumping phase of the piston on vibration and noise of th high pressure tandem axial type piston pump on the best of theoretical research in $this^(1)$. Therefore considering the pumping phase of the piston when assembling the tandem axial type piston pump, it is possible to reduce 1.5~2[dB]of sound level.

  • PDF

유체로 연성되고 두께가 상이한 두 직사각 평판의 실험적 모드 해석 (Experimental Modal Analysis of Two Unequal Rectangular Plates Coupled with Fluid)

  • 유계형;정경훈;이성철
    • 대한기계학회논문집A
    • /
    • 제26권12호
    • /
    • pp.2541-2549
    • /
    • 2002
  • In order to study the vibration characteristics of fluid-structure interaction problem, two rectangular plates coupled with bounded fluid were investigated. Experimental modal analyses were carried out to extract the modal parameters of the system. Additionally. finite element modal analyses performed using a commercial computer code, ANSYS. The FEM solutions were compared with the experimental solutions to verify the finite element model. As a result, the comparison between the experiment and FEM results showed excellent agreement. The transverse vibration modes, in-phase and out-of-phase, were observed alternately in the fluid-coupled system. The thickness effect of the plates on the fluid-coupled natural frequencies and mode shapes was investigated for two different cases with the identical thickness and the unequal thickness. It was found that the coupled natural frequencies increase with the thickness for the identical plates regardless of the mode phase. The experimental and the finite element analysis results showed that the out-of-phase mode shapes were deviated from the symmetrical mode shapes in the plate transverse direction fur the unequal plate thickness case.

MNT 시스템에서의 편광소자에 의한 위상오차분석 (Optimization of Modified Triangular Interferometer)

  • 김수길;고명숙
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2007년도 춘계학술대회 논문집
    • /
    • pp.117-119
    • /
    • 2007
  • We need two operation modes to obtain the complex hologram without bias and the conjugate image in the modified triangular interferometer(MTI). To solve the problem, we proposed the optimized MTI with one wave plate, which can obtain cosine and sine functions by the combination of one wave plate and one linear polarizer. In the extraction of phase term using the combination of polarization components, the phase error occurs, and we analyzed such potential phase errors in the optimized MTI.

  • PDF

Cold plate를 이용한 휴대용 컴퓨터 냉각 시스템의 열성능에 관한 연구 (A Study on Thermal Performance of Cooling System for a Laptop Computer Using a Cold Plate)

  • 박상희;조남해;최성대
    • 한국기계가공학회지
    • /
    • 제8권4호
    • /
    • pp.83-89
    • /
    • 2009
  • This study investigates two-phase cooling system of close-loop by using FC-72 and PCM(Phase change material). The cooling system consists of evaporator, cold plate, micro pump, and condenser. The heat input on the performance of evaporator is appreciated by visualizing the boiling on the evaporator. The heat performance of cooling system is investigated to determine the effects of volume fill ratio change at working fluid, pump flow rate change, and volume fill ratio change at PCM in cold plate. Experimental results show the ideal condition when the volume ratio of working fluid, the pump flowing, and the volume ratio of PCM are 60%, 6ml/min, and 60% respectively.

  • PDF

$Si_3N_4-Al_2O_3-SiO_2$계의 1,$700^{\circ}C$에서 생성하는 화합물의 상관계 및 미구조 (Phase Relations and Microstructure of Comounds in the $Si_3N_4-Al_2O_3-SiO_2$ system at $1700^{\cire}C$)

  • 이의종;김환
    • 한국세라믹학회지
    • /
    • 제16권4호
    • /
    • pp.206-212
    • /
    • 1979
  • The phase relations and microstructure appeared at 1700℃ in a system of Si3N4-Al2O3-SiO2 were studied. The samples were pressurelessly sintered at 1700℃ for 1hr and reheated at 1600℃ for 1hr under nitrogen atmosphere. The compounds formed were identified by X-ray diffraction method and the microstrues were observed by SEM. The stable phases appeared in this system were X-phase, Si2ON2, β'-Si3N4 and Mullite. From the results of those experiments, it was concluded that the X-phase has very close composition to that proposed by G, K. Layden, Si3Al6O12N2. SEM photographs showed that Si2ON2 was a plate phase and X-phase was a rectagular plate phase.

  • PDF

단상유동 조건에서 용접형 판형 열교환기의 열전달 및 압력강하 특성연구 (Heat Transfer and Pressure Drop Characteristics of Brazed Plate Heat Exchangers with Single-Phase Flow)

  • 김만배;박창용
    • 설비공학논문집
    • /
    • 제26권11호
    • /
    • pp.522-528
    • /
    • 2014
  • This experimental study measured and analyzed the heat transfer and pressure drop performance of brazed plate heat exchangers. Heat exchangers with different plate numbers of 10, 20, 30, and 40 were used for measurement, and their plate pattern was identical. The experiment was performed with distilled water, by changing the hot-side flow rate, with the cold-side flow rate fixed. The experimental results were compared with the calculated values by correlations based on gasketed plate heat exchangers, and showed that the heat transfer performance and pressure drop of brazed plated heat exchangers were higher than those of gasketed plate heat exchangers. From the variation of the friction factor, it could be inferred that in the flow channels of brazed plate heat exchangers, turbulent flow occurred at Reynolds numbers higher than 500. A new correlation to predict the Nusselt number was developed, and its absolute average deviation was 2.62%, compared with the values from the experimental data.