• Title/Summary/Keyword: Phase method

Search Result 13,694, Processing Time 0.032 seconds

Output Voltage Control in a Serise Multilevel H-bridge Inverter with SHE-PWM Method (직렬 멀티레벨 H-bridge inverter에서 SHE-PWM방식을 사용한 출력 전 압의 제어)

  • Kim J.Y.;Jeong S.G.
    • Proceedings of the KIPE Conference
    • /
    • 2003.07a
    • /
    • pp.1-4
    • /
    • 2003
  • This paper proposes a method of voltage control for three-phase multilevel H-bridge inverters with selective harmonic elimination (SHE) PWM The full-bridge configuration of H-bridge inverter cells enables voltage control with a fixed PWM pattern by means of phase shifting between the legs, which greatly simplifies the control while maintaining the harmonic elimination characteristics. The series combination of the cells in multilevel configuration can be exploited to further improve the hormonic elimination characteristics with proper phase shifting between the ceil volitage. A complexor-based control method is introduced to control the magnitude and phase angle of cell voltages that form three-phase multilevel output voltages. Simulation results show that the proposed method along with SHE PWM would provide satisfactory performance in spite of its simplicity.

  • PDF

Developed Inherent Strain Method Considering Phase Transformation of Mild Steel in Line Heating (선상가열시 강의 상변태를 고려한 개선된 고유변형도 기반의 등가하중법)

  • Ha, Yun-Sok;Jang, Chang-Doo
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.41 no.6
    • /
    • pp.65-74
    • /
    • 2004
  • The inherent strain method is known to be very efficient in predicting the deformation of steel plate by line heating. However, in the actual line heating process in shipyard, the rapid quenching changes the phase of steel. In this study, In order to consider additional effects under phase transformation, inherent strain regions were assumed to expand. Also, when calculating inherent strain, material properties of steel in heating and cooling are applied differently considering phase transformation. In this process, a new method which can reflect thermal volume expansion of martensite is suggested.8y the suggested method, it was possible to predict the plate deformations by line heating more precisely.

Enhanced Phase Angle Detect Method Using High-pass Filter (고주파 필터를 이용한 개선된 위상각 검출 방법)

  • Heo, Min-Ho;Song, Sung-Gun;Kim, Gwang-Heon;Nam, Hae-Gon;Park, Sung-Jun
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.12
    • /
    • pp.2370-2378
    • /
    • 2009
  • The enhanced phase angle estimation algorithm is essential to supply the power stably under synchronizing with grid source. In this paper, we are proposed the novel phase angle estimation algorithm and verified the validity of proposed method as simulation with PSIM and experiments. We sort the harmonics element using high-pass filter(HPF) that have the cut-off frequency below basic element and make reverse d-q transformation. So, it can be restored the harmonics element at stationary axis, and we can get the fundamental voltage element of AC grid. Proposed PLL method have a rapid responsibility and a large margin at controller design than conventional method because it have a small phase delay and a sufficient controller gain margin. And, it can reduce the error of voltage rms value and axis transformation according to robust PLL algorithm against the harmonic and phase unbalance.

Numerical Study on The Pressure Drop of Immiscible Two-Phase Flow in The Pressure Driven Micro Channel Using Lattice Boltzmann Method (Lattice Boltzmann 방법을 이용한 압력구동 미세채널 내 비혼합 2상 유체 흐름의 압력강하에 대한 수치적 연구)

  • Jeong, Soo-In;Kim, Kui-Soon;Kang, Beom-Soon
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2008.03b
    • /
    • pp.436-439
    • /
    • 2008
  • Computer simulation of multiphase flows has grown dramatically in the last two decades. In this work, we have studied the flow characteristics of immiscible two fluids in a 2-D micro channel driven by pressure gradient using multi-phase lattice Boltzmann method suggested by Shan and Chen(1993) considering the fluid-surface interaction. we tried to examine the effects of parameters related to the two phase flow characteristics and pressure drop in the micro channel like contact angle and channel configuration by changing their value. The results of current study could show the lattice Boltzmann method can simulate the behaviors of two phase flow in the region of micro fluidics well.

  • PDF

A Modified Sapce-Vector PWM Inverter without Phase Current Sensors

  • Joo, Hyeong-Gil;Shin, Hwi-Beom;Oh, In-Hwan;Youn, Myung-Joong
    • Journal of Electrical Engineering and information Science
    • /
    • v.2 no.4
    • /
    • pp.86-91
    • /
    • 1997
  • A method of detecting the three phase currents for a voltage-fed pusle width modulated(PWM) inverter is proposed, where only one current sensor is utilized on the dc-link. The proposed method has the constant sampling time by employing he modified space-vector PWM technique which generates the rearranged switching pattern to detect a phase current from ad dc-link current. Experimental results show that eh proposed scheme provides a very good detection method of three phase currents without phase current sensors. This method is very simple and has small detection errors.

  • PDF

A Numerical Study on the Phase-change Heat transfer problem in Cryosurgery (냉동수술시 수반되는 상변화 열전달 문제에 대한 수치해석적 연구)

  • 김동혁
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.20 no.3
    • /
    • pp.162-170
    • /
    • 1996
  • A numerical study on the Stefan problem occurred in cryosurgery is performed. Crank-Nicholson type finite difference algorithm based on the enthaly method is adapted to solve the phase change problem in this study. As it is a moving boundary problem, special emphasis is put on the estimation of the freezing front location. Two cases selected here are freezings of human tissue by disk type cryoprobe and by hemispherical one. In both cases, the heat flows are considered to be one dimensional. The calculated results using enthalpy method are compared with those using the program TRUMP and with Neumann's solution. These results agree guite well with each other. While it is pretty difficult to get accurate freezing front location by TRUMP due to the so- called "phase change knee" occured during the phase change, the algorithm based on the enthalpy method is proved to be very powerful to cope with this kind of problem.f problem.

  • PDF

Analysis of the torque transient performance of the induction motor by means of phase segregation method (상분리법에 의한 유도전동기의 토오크 과도특성해석)

  • Jeong, Jong-Ho;Lee, Eun-Woong;Choi, Jae-Young
    • Proceedings of the KIEE Conference
    • /
    • 2000.11b
    • /
    • pp.247-249
    • /
    • 2000
  • Transient phenomena cause delay in control response and must be studied and eliminated, if possible, suppressed. The difficulty in analyzing transient phenomena in ac machines comes from the large number of windings involved. But, it is possible that only one phase is used to represent three phases of the induction motor as called phase segregation method. The phase segregation method provides equivalent circuits for both the steady and transient states of induction motor. In this paper, analysis of the torque transient of the induction motor be carried out the phase segregation method and confirmed in the possibility of transientless torque control.

  • PDF

Control Bandwidth Extension Method Based on Phase Margin Compensation for Inverters with Low Carrier Ratio

  • Wei, Qikang;Liu, Bangyin;Duan, Shanxu
    • Journal of Power Electronics
    • /
    • v.18 no.6
    • /
    • pp.1760-1770
    • /
    • 2018
  • This paper presents a control bandwidth extension method for inverters with a low carrier ratio. The bandwidth is extended at the price of decreasing the phase margin. Then the phase margin is compensated by introducing an extra leading angle into an inverse Park transformation. The model of the controller with the proposed method is established. The magnitude and phase characteristics are also analyzed. Then the influence on system stability when the leading angle is introduced is analyzed. The proposed method is applied to design an inverter controller with both a large bandwidth and a desired phase margin, and the experimental results verify that the controller performs well in the steady-state and in terms of transient response.

3-D Surface Profile Measurement Using An Acousto-optic Tunable Filter Based Spectral Phase Shifting Technique

  • Kim, Dae-Suk;Cho, Yong-Jai
    • Journal of the Optical Society of Korea
    • /
    • v.12 no.4
    • /
    • pp.281-287
    • /
    • 2008
  • An acousto-optic tunable filter based 3-D micro surface profile measurement using an equally spaced 5 spectral phase shifting is described. The 5-bucket spectral phase shifting method is compared with a Fourier-transform method in the spectral domain. It can provide a fast measurement capability while maintaining high accuracy since it needs only 5 pieces of spectrally phase shifted imaging data and a simple calculation in comparison with the Fourier transform method that requires full wavelength scanning data and relatively complicated computation. The 3-D profile data of micro objects can be obtained in a few seconds with an accuracy of ${\sim}10nm$. The 3-D profile method also has an inherent benefit in terms of being speckle-free in measuring diffuse micro objects by employing an incoherent light source. Those simplicity and practical applicability is expected to have diverse applications in 3-D micro profilometry such as semiconductors and micro-biology.

Carrier Phase-Shift PWM to Reduce Common-Mode Voltage for Three-Level T-Type NPC Inverters

  • Nguyen, Tuyen D.;Phan, Dzung Quoc;Dao, Dat Ngoc;Lee, Hong-Hee
    • Journal of Power Electronics
    • /
    • v.14 no.6
    • /
    • pp.1197-1207
    • /
    • 2014
  • Common-mode voltage (CMV) causes overvoltage stress to winding insulation and damages AC motors. CMV with high dv/dt causes leakage currents, which create noise problems for equipment installed near the converter. This study proposes a new pulse-width modulation (PWM) strategy for three-level T-type NPC inverters. This strategy substantially eliminates CMV. The principle for selecting suitable triangle carrier signals for the three-level T-type NPC is described. The proposed method can mitigate the peak value of CMV by 50% compared with the phase disposition pulse-width modulation method. Furthermore, the proposed method exhibits better harmonic spectrum and lower root mean square value for the CMV than those of the reduced-CMV method on the basis of the phase opposition disposition PWM scheme with modulation index higher than 0.5. The proposed modulation can easily be implemented using software without any additional hardware modifications. Both simulation and experimental results demonstrate that the proposed carrier phase-shift PWM method has good output waveform performance and reduces CMV.