• 제목/요약/키워드: Phase displacement

검색결과 576건 처리시간 0.025초

전류변성기 비교기의 위상오차 평가 기술 (Evaluation technique for phase displacement of current transformer comparator)

  • 김윤형;한상길;정재갑;한상옥
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 제39회 하계학술대회
    • /
    • pp.2032-2033
    • /
    • 2008
  • We have developed an evaluation technique for phase displacement of current transformer (CT) comparator by using the precise standard capacitors and resistors. By applying this technique for equivalent circuit of CT comparator evaluation system, we can obtain the calculated and measured phase displacement in the CT comparator. Thus we can evaluate phase displacement of CT comparator by comparing the calculated and measured phase displacement. The method was applied to CT comparator under test with the phase displacement ranges of $0{\sim}{\pm}7.5$ crad. Finally we have compared the phase displacement of the CT comparator under test theoretically obtained in this method with the specification.

  • PDF

Application of Phase-Shifting Method in Speckle Interferomtery to Measurement of Micro-Scale Displacement

  • Baek, Tae-Hyun;Kim, Myung-Soo
    • 비파괴검사학회지
    • /
    • 제26권3호
    • /
    • pp.162-168
    • /
    • 2006
  • Speckle interferometry with phase-shifting method has been applied to measurement of micro-scale displacement through optical signal processing. Four-step phase-shifting method by PZT is used to measure out-of-plane displacement in spot-welded cantilever and results of optical experiments are comparable to those of FEM. Phase-shifting method using Fourier transform by PZT is applied to measurement of in-plane displacement on rectangular steel plate with a circular hole. The results of optical experiment agree well with theoretical calculation. New phase-shifting method in speckle interferometry has been implemented with a quarter wave plate. In-plane displacement of specimen is measured by the new phase-shifting method. Results of optical experiment show that the quarter wave plate can be used for phase-shifting method that is cheap and easy to use in speckle interferometry.

전류변성기 비교기의 비오차 및 위상오차 평가기술 (Evaluation Technique for Ratio Error and Phase Displacement of Current Transformer Comparator)

  • 김윤형;한상길;정재갑;한상옥
    • 전기학회논문지P
    • /
    • 제57권4호
    • /
    • pp.437-443
    • /
    • 2008
  • We have developed an evaluation technique for both ratio error and phase displacement of current transformer (CT) comparator by using the precise standard capacitors and resistors. By applying this technique to equivalent circuit of CT comparator evaluation system, we can obtain the calculated and measured ratio errors (or phase displacements) in the CT comparator. Thus we can evaluate ratio errors and phase displacement of CT comparator by comparing the calculated and measured ratio errors (or phase displacements). The method was applied to CT comparator under test with the ratio errors and phase displacement ranges of $0{\sim}{\pm}10%$ and $0{\sim}{\pm}7.5$ crad, respectively. Finally we have compared the ratio error and phase displacement of the CT comparator obtained in this method with specifications of two companies.

미터링 오리피스를 이용한 방향제어밸브 위상각 대역폭 주파수 측정에 관한 연구 (A Study on the Phase Bandwidth Frequency of a Directional Control Valve based on the Metering Orifice)

  • 김성동;전세형;윤주섭
    • 드라이브 ㆍ 컨트롤
    • /
    • 제15권1호
    • /
    • pp.1-9
    • /
    • 2018
  • The spool displacement of directional control valve can be considered as the standard signal to measure the bandwidth frequency of a directional control valve. When the spool displacement is not available, the metering-orifice system is implemented in this research as an alternative way of measuring the 90 degrees phase bandwidth frequency of the hydraulic directional control valve. The inertia effect on the transmission line oil induces the phase lead of the valve load pressure when compared with the phase of spool displacement. The capacitance effect of the oil induces the phase lag of the valve load pressure. The phase of the load pressure can be adjusted to be the same as that of the spool displacement by controlling the opening area of the metering orifice. A series of experiments were conducted to verify the effectiveness of the metering orifice. The 90 degrees phase bandwidth frequency measured from the valve load pressure was significantly deviated in some cases from the frequency of the spool displacement. The metering orifice was hard to be applied to measure the -90 degrees phase bandwidth frequency of the high precision.

노인의 장애물 보행 시 장애물 높이에 의한 압력중심 이동시간의 차이 (Time Difference of the COP Displacement according Obstacle Height during Obstacle Crossing in Older Adults)

  • 박설;김경;박지원
    • The Journal of Korean Physical Therapy
    • /
    • 제23권2호
    • /
    • pp.1-5
    • /
    • 2011
  • Purpose: This study examined the difference in the center of pressure (COP) displacement time in older adults according to the obstacle height during stance at each sub.phase when crossing obstacles. Methods: Fifteen older adults were enrolled in this study (${\geq}65$ years of age). The F-scan was used to measure the COP displacement time when crossing a 0, 10 and 40cm obstacle, and the stance phase was divided into 4 sub-phases according to the foot contact pattern. Results: During the stance phase, the COP displacement time increased with increasing obstacle height. During the mid-stance, terminal stance and pre-swing except for the loading response, there were significant differences in the COP displacement time according to the obstacle height. Conclusion: This study suggests that older adults show differences in the COP displacement time according to the stance sub-phase while crossing obstacles, and they use different mechanisms according the sub-phases to maintain balance during obstacle crossing.

고층 스카이브리지의 변위 허용치 산정에 대한 연구 (Study on Evaluating Displacement Tolerance of Sky-bridge in Tall Buildings)

  • 김윤곤
    • 대한건축학회논문집:구조계
    • /
    • 제36권4호
    • /
    • pp.135-142
    • /
    • 2020
  • The new method for evaluating the displacement tolerance of sky-bridges with pin-roller type supports was proposed considering both return period of phase difference between connected buildings and geometrical characteristics of skybridge. Because displacement tolerance is relative value, which is most affected by the phase difference of the connected buildings, the dynamic response of these building with time history analysis should be evaluated. However, the initial phase could not be specified, so the result of displacement tolerance would be varied with respect to initial value. Thus, the tolerance can be reasonably evaluated SRSS calculation with design displacements based on statistical approach and of each building. In addition, the geometrical characteristics of sky-bridge should be considered because the transverse displacement of sky-bridge span causes the shear deformation of the bridge and longitudinal displacement tolerance cannot release the shear deformation. Therefore, the some pin-end support in sky-bridge should have longitudinal displacement tolerance to accommodate the shear deformation. By resolving this shear deformation, it is possible not only to accommodate transverse displacement, but also to avoid the complicated joint details such as both pot bearing and guided supports with shear key.

An absolute displacement approach for modeling of sliding structures

  • Krishnamoorthy, A.
    • Structural Engineering and Mechanics
    • /
    • 제29권6호
    • /
    • pp.659-671
    • /
    • 2008
  • A procedure to analyse the space frame structure fixed at base as well as resting on sliding bearing using total or absolute displacement in dynamic equation is developed. In the present method, the effect of ground acceleration is not considered as equivalent force. Instead, the ground acceleration is considered as a known value in the acceleration vector at degree of freedom corresponding to base of the structure when the structure is in non-sliding phase. When the structure is in sliding phase, only a force equal to the maximum frictional resistance is applied at base. Also, in this method, the stiffness matrix, mass matrix and the damping matrix will not change when the structure enters from one phase to another. The results obtained from the present method using absolute displacement approach are compared with the results obtained from the analysis of structure using relative displacement approach. The applicability of the analysis is also demonstrated to obtain the response of the structure resting on sliding bearing with restoring force device.

The Relationship between Dynamic Balance Measures and Center of Pressure Displacement Time in Older Adults during an Obstacle Crossing

  • Park, Seol;Park, Ji-Won
    • The Journal of Korean Physical Therapy
    • /
    • 제23권3호
    • /
    • pp.1-5
    • /
    • 2011
  • Purpose: This study examined the relationship between the center of pressure (COP) displacement time during the stance phase and dynamic balance ability when older adults cross a 10 cm obstacle. Methods: Fifteen older adults were enrolled in this study (all ${\geq}65$ years of age). The F-scan was used to measure the COP displacement time when subjects cross a 10 cm obstacle, and the Dynamic gait index. Berg's balance scale and the Four square step test were used to measure dynamic balance ability. Results: The Dynamic gait index, Berg's balance scale and the Four square step test were correlated with each other. Dynamic balance ability was correlated with COP displacement time during the stance phase at an obstacle crossing in older adults. Conclusion: People with higher dynamic balance ability show a smaller COP displacement time during the stance phase at an obstacle crossing. Therefore, dynamic balance ability can be predicted by measuring the center of pressure displacement time.

초음파 센서를 이용한 변위 측정 시스템 개발 (A Development of Displacement Measurement System using Ultrasonic Sensor)

  • 김정섭;김상희
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1995년도 추계학술대회 논문집 학회본부
    • /
    • pp.142-145
    • /
    • 1995
  • This paper is to develop a measurement system of the displacement distance using ultrasonic sensors. Two 400KHz ultrasonic sensors are used for realizing the measurement system, such as one sensor transmits the sine wave and the other sensor receives this wave. The displacement is measured by the phase difference between transmitting and receiving signals. A phase defecter transforms phase difference to voltage. Because the output voltage pattern has nonlinear characteristics, the relations of the voltage and the distance are learned by a neural network. As the results of teaming, the efficiency of measurement system is improved. This system can measure the displacement distance at the accuracy of 1 micrometer level.

  • PDF

철심형 전류변성기의 비오차 및 위상오차 절대 평가 기술의 확장 : 1차 전류 = $5\;kA{\sim}40\;kA$ (Extension of Absolute Evaluation Technique for Ratio Error and Phase Displacement of Core Type Current Transformers: Ip =$5\;kA{\sim}40\;kA$)

  • 김윤형;한상길;정재갑;한상옥
    • 전기학회논문지P
    • /
    • 제57권4호
    • /
    • pp.431-436
    • /
    • 2008
  • We have extended an absolute evaluation method to obtain the ratio error and phase displacement of a current transformer (CT) up to primary current of 40,000 A by measuring four parameters of equivalent circuit in CT. The method was applied to CTs under test with the current ratios in the range of 5,000 A / 5 A - 40,000 A / 5 A. The ratio error and phase displacement of the CTs under test obtained in this study are consistent with those measured at the national institutes in Canada and Germany using the same CTs under test within an expanded uncertainty (k = 2) in the overall current ratios.