• 제목/요약/키워드: Phase compensating transformer

검색결과 21건 처리시간 0.022초

교류전압 보상 기능을 갖는 독립형 단상 연료전지 마이크로 소스 (Stand-Alone Type Single-Phase Fuel Cells Micro-Source with ac Voltage Compensation Capability)

  • 정영국
    • 전기학회논문지
    • /
    • 제58권1호
    • /
    • pp.35-41
    • /
    • 2009
  • This paper proposes a stand alone type single-phase fuel cells micro-source with a voltage sag compensator for compensating the ac output voltage variations (sag or swell) of micro-source. The proposed micro-source is consist of a PEM(polymer electrolyte membrane) fuel cells simulator, a full bridge de converter, a 60Hz PWM(pulse width modulation) VSI(voltage source inverter), and a voltage sag compensator. Voltage sag compensator is similar to the configuration of hybrid series active power filter, and it is directly connected to micro-source through the injection transformer. Compensation algorithm of a voltage sag compensator adopts a single phase p-q theory. Effectiveness of the proposed the system is verified by the PSIM(power electronics simulation tool) simulation in the steady state and transient state which the proposed system is able to simultaneously compensate the harmonic current and source voltage sag or swell.

직접 보상전압 추출기법을 이용하여 고조파전류와 무효전력을 보상하는 3상 4선식 직렬 형 능동전력필터의 제어법 (Three-phase Four-wire Series Active Power Filter Control Strategy for The Compensation of Harmonics and Reactive Power Based-on Direct Compensating Voltage Extraction Method)

  • 김진선;김영석
    • 전력전자학회논문지
    • /
    • 제9권3호
    • /
    • pp.213-221
    • /
    • 2004
  • 최근에, 평활용 직류 커패시터가 설치된 다이오드 정류기가 가전제품 및 교류 운전 장치와 같은 전자 장치에 점점 많이 사용되고 있고, 이러한 부하에 의해서 발생하는 고조파 문제가 점차 중요한 문제로 부각되고 있다. 또한, 3상 4선식 전력 시스템은 상업용 빌딩이나 제조 플랜트 등에 전력을 공급하는 방법으로 많이 사용되고 있는데 이러한 시스템에서는 중성선에 과도한 전류가 흐르게 되고, 중성선 전류는 기본적으로 3고조파 성분으로 중성선 도체 사이즈 선정의 실패나 중성점의 전위를 상승시키거나 변압기의 과열 현상 등을 유발할 수 있다. 이러한 관점에서 본 논문에서는 직접 보상전압 추출기법으로 동작하는 직렬 형 능동 필터를 제안하며, 성능함수 알고리즘의 장점은 게인을 곱하지 않고 보상 전압을 직접 구함으로써, 어떠한 다른 알고리즘보다 보상 전압 계산 방법이 간단하다. 제안된 알고리즘의 타당성을 증명하기 위하여 프로토타입 능동 필터를 제작하여 실험을 수행하였다.

철도 부하의 동적 특성을 고려한 전류 불평형의 분석과 보상 (Analysis and compensation of the current unbalance considering dynamic characteristic of feeding traction loads)

  • 김기표;김진오
    • 조명전기설비학회논문지
    • /
    • 제17권1호
    • /
    • pp.54-60
    • /
    • 2003
  • 3상 전력계통에 단상 대용량의 전철부하가 접속되면 3상 전류가 불평형하게 되어 역상 전류가 흐르게 된다. 이 역상전류는 전원 측 발전기의 회전자 표면에 과전류를 발생시키며, 급전계통 및 관련 설비에 나쁜 영향을 끼치게 된다. 현재 교류 전기철도에서는 불평형 경감을 위하여 Scott결선 변압기를 채용하고 있으나 2차 극의 서로 다른 단상부하 크기 및 위상을 동일하게 일치시킬 수는 없고, 회생부하 전기차 도입과 인관 변전소 사고로 인한 연장급진도 고려해야 되기 때문에 역상전류 보상기가 필요하다. 본 논문은 기존의 전류불평형 해석방법인 정적모델 평가기법 대신에 열차운행스케줄에 따른 동적 특성을 이용한 새로운 전류불평형 평가기법을 유도하였으며, 이를 통해 부하 측의 불평형에 의해 발생하는 역상전류를 흡수하기 위한 보상기를 제안하고 실 계통에 가까운 전류불평형 문제를 분석하였다.

3상 PWM 전압형 인버터에 발생하는 누설전류와 동상모드 전압의 억제 (The Suppression of both leakage current and common-mode voltage occurring three phase PWM voltage type inverter)

  • 문상필;서기영;권순걸;김주용;김영문;김해제;김종실
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 제36회 하계학술대회 논문집 B
    • /
    • pp.1515-1517
    • /
    • 2005
  • In this paper, we represent both occurrence reason of Surge-voltage and Leakage-current of AC drive system which is operated by Voltage-type PWM Inverter. It generates a compensating voltage which has the same amplitude as, but the opposite phase to, the common-mode voltage produced by the PWM inverter. The compensating voltage is superimposed on the inverter output by a common-mode transformer. As a result, the common-mode voltage applied to the load is canceled completely. The design method of the active common-mode noise canceler is also presented in detail. Therefore, we try to describe the method controling both of them and all of the proprieties are proved by our experiment.

  • PDF

공극 변류기의 2차 전류 보상 (Compensation for the Secondary Current of an Air-gapped Current Transformer)

  • 강용철;정태영;장성일;김용균;박지연
    • 전기학회논문지
    • /
    • 제57권2호
    • /
    • pp.149-154
    • /
    • 2008
  • An air-gapped current transformer(CT) has been used to reduce a remanent flux in the core, particularly in the case of auto-reclosure. However, it causes larger transient, ratio and phase errors than the iron-cored CT because of the small magnetizing inductance. This paper proposes a compensation algorithm for the secondary current of the air-gapped CT during the fault conditions including auto-reclosure as well as in the steady-state. The core flux is calculated from the measured secondary current of the CT and inserted into the hysteresis loop to estimate the exciting current. Finally, the correct current is estimated by adding the measured secondary current to the estimated exciting current. Various test results clearly indicate that the proposed compensating algorithm can improve the accuracy of the air-gapped CT significantly and reduce the required core cross-section of the air-gapped CT significantly.

CCVT의 2차 전압 보상 방법 (Compensation of the Secondary Voltage of a Coupling Capacitor Voltage Transformer)

  • 강용철;정태영;이지훈;장성일;김용균
    • 전기학회논문지
    • /
    • 제57권6호
    • /
    • pp.909-914
    • /
    • 2008
  • A coupling capacitor voltage transformer(CCVT) is used in an extra or ultra high voltage system to obtain the standard low voltage signal for protection. To avoid the phase angle error between the primary and secondary voltages, a tuning reactor is connected between a capacitor and a voltage transformer. The inductance of the reactor is designed based on the power system frequency. If a fault occurs on the power system, the secondary voltage of the CCVT contains some errors due to a dc offset component and harmonic components resulting from the fault. The errors become severe in the case of a close-in fault. This paper proposes an algorithm for compensating the secondary voltage of a CCVT in the time-domain. From the measured secondary voltage of the CCVT, the secondary and primary currents are obtained; then the voltage across the capacitor and the inductor is calculated and then added to the measured secondary voltage to obtain the correct primary voltage. Test results indicate that the proposed algorithm can compensate the distorted secondary voltage of the CCVT irrespective of the fault distance, the fault inception angle, and the burden of the CCVT.

고안정 전류제어 전원장치 (A Highly Stable Current-Controlled Power Supply)

  • Kwon, Bong-Hwan
    • 대한전기학회논문지
    • /
    • 제41권2호
    • /
    • pp.144-155
    • /
    • 1992
  • A design of a highly stable current-controlled power supply combining the phase-controlled rectifier (PCR), passive filter and active filter is investigated. A digital phase-looked voltage control (PLVC) with a capability of compensating the thyristor firing angles under unvalanced power source is proposed` otherwise the PCR output voltage has low-order subharmonics whose suppression requires a bulky passive filter. The digital PLVC has a fast dynamic characteristics as an inner control loop of the PCR. To suppress further the output ripple, an active filter using a transformer is introduced and its design is described through the frequency domain analysis. An optimal integral, proportional and measurable variable feedback (IPM) controller is designed using the time-weighted performance index based on the time domain analysis. The design method based on the time-weighted performance index gives better response characteristics than that based on the conventional performance index. It is also shown via experimental results that the proposed scheme gives better response characteristics than that based on the conventional performance index. It is also shown via experimental results that the proposed scheme gives good dynamic and static performances.

영상성분을 고려한 DVR 기기 해석 (The Analysis of Zero Sequence Components in Dynamic Voltage Restorer System)

  • 정일엽;박상영;원동준;문승일;박종근;한병문
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제51권4호
    • /
    • pp.169-174
    • /
    • 2002
  • The magnitude and phase of the compensating voltage in Dynamic Voltage Restorer (DVR) system depend on the voltage sag in the phases affected by the fault and on the influence of the zero sequence components. If the delta connection of the transformer is used, the zero sequence components do not appear on the load side. But nowadays, Y connected transformers with grounded neutral, that is 3-phase 4-wire system, are usually used. Therefore the zero-sequence components are occurred during faults. The zero-sequence components result in the high insulation costs and the asymmetry of the phase and magnitude of the terminal voltages. In this paper 3 phase 4 wire distribution system and 3 phase 3 wire system are analyzed and characteristics of voltage sag are presented. And this paper proposes the method that can mitigate the zero-sequence under the unbalance faults causing voltage sage and phase angle iumps.

전원측 리액터 불평형을 고려한 전압형 컨버터의 전류 보상 제어기 구현 (The Implementation of Current Compensation Controller in Driving Voltage type Converter considering the Unbalance of Reactor at the Source Side)

  • 전지용;조유환;이근홍
    • 한국산학기술학회논문지
    • /
    • 제5권5호
    • /
    • pp.413-420
    • /
    • 2004
  • 본 연구에서는 인버터를 구동하는 용도의 직류전원장치에 대한 제어 알고리즘 개발을 목표로 하고 있으며, 구동과 회생기능을 갖는 전압형 PWM 컨버터에서 운전시 전원의 불평형을 보상하는 제어방법을 제안하고자 한다. 이를 위해 전력회생기능을 갖는 정류기에 대하여 기존 다이오드 및 SCR을 이용한 정류방식과의 비교를 통해 본 제어방식의 우수성을 시뮬레이션과 실험을 통해 입증하고자 한다. 전력변환기가 항상 평형상태를 유지하기 위해 전류제어 루프에 의하여 불평형 상태를 보상하는 방법을 사용하였으며, 통상적으로 전력변환기의 구성시 각상의 리액턴스가 같지 않은 누설변압기 등의 사용을 가능하게 하므로 제안된 전력변환기의 리액턴스가 불평형상태가 되어도 운전시 항상 평형상태로 유지되어 시스템을 안정적으로 구동 시킬 수 있는 제어기법의 설계를 통해 어떤 환경에서도 장치의 안정된 구동특성을 확인하고자 하였다.

  • PDF

Design and Implementation of Solar PV for Power Quality Enhancement in Three-Phase Four-Wire Distribution System

  • Guna Sekar, T.;Anita, R.
    • Journal of Electrical Engineering and Technology
    • /
    • 제10권1호
    • /
    • pp.75-82
    • /
    • 2015
  • This paper presents a new technique for enhancing power quality by reducing harmonics in the neutral conductor. Three-Phase Four-Wire (3P4W) system is commonly used where single and three phase loads are connected to Point of Common Coupling (PCC). Due to unbalance loads, the 3P4W distribution system becomes unbalance and current flows in the neutral conductor. If loads are non-linear, then the harmonic content of current will flow in neutral conductor. The neutral current that may flow towards transformer neutral point is compensated by using a series active filter. In order to reduce the harmonic content, the series active filter is connected in series with the neutral conductor by which neutral and phase current harmonics are reduced significantly. In this paper, solar PV based inverter circuit is proposed for compensating neutral current harmonics. The simulation is carried out in MATLAB/SIMULINK and also an experimental setup is developed to verify the effectiveness of the proposed method.