Clinical Applications of Neuroimaging with Susceptibility Weighted Imaging: Review Article (SWI의 신경영상분야의 임상적 이용)

  • Roh, Keuntak;Kang, Hyunkoo;Kim, Injoong
    • Investigative Magnetic Resonance Imaging
    • /
    • v.18 no.4
    • /
    • pp.290-302
    • /
    • 2014
  • Purpose : Susceptibility-weighted magnetic resonance (MR) sequence is three-dimensional (3D), spoiled gradient-echo pulse sequences that provide a high sensitivity for the detection of blood degradation products, calcifications, and iron deposits. This pictorial review is aimed at illustrating and discussing its main clinical applications. Materials and Methods: SWI is based on high-resolution, 3D, fully velocity-compensated gradient-echo sequences using both magnitude and phase images. To enhance the visibility of the venous structures, the magnitude images are multiplied with a phase mask generated from the filtered phase data, which are displayed at best after post-processing of the 3D dataset with the minimal intensity projection algorithm. A total of 200 patients underwent MR examinations that included SWI on a 3 tesla MR imager were enrolled. Results: SWI is very useful in detecting multiple brain disorders. Among the 200 patients, 80 showed developmental venous anomaly, 22 showed cavernous malformation, 12 showed calcifications in various conditions, 21 showed cerebrovascular accident with susceptibility vessel sign or microbleeds, 52 showed brain tumors, 2 showed diffuse axonal injury, 3 showed arteriovenous malformation, 5 showed dural arteriovenous fistula, 1 showed moyamoya disease, and 2 showed Parkinson's disease. Conclusion: SWI is useful in detecting occult low flow vascular lesions, calcification and microbleed and characterising diverse brain disorders.

Analysis on the Operation Characteristics of Induction Motor Operated by Symmetric Unbalanced Voltage (대칭 불평형 전압 운전시 유도전동기의 동작 특성 해석)

  • Kim, Jong-Gyeum;Sohn, Hong-Kwan;Jeong, Jong-Ho;Lee, Eun-Woong
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.53 no.3
    • /
    • pp.110-115
    • /
    • 2004
  • Most of the loads in industrial power distribution systems are balanced and connected to three power systems. However, in the user power distribution systems, most of the loads are single & three phase and unbalanced, generating voltage unbalance. This paper presents a scheme on operation states of a three-phase induction motor under unbalanced voltages. The three-phase voltages applied to the stator winding of the studied induction motor are controlled by respectively adjusting the magnitude and phase angle of each phase. The voltage unbalanced factor(VUF) of the three-phase source voltages can then be varied to examine the different values of VUF on machine's operation characteristics.

Comparison of VUF using Resistor & Inductive Load (저항성 및 유도성 부하의 운전시 전압불평형율의 비교)

  • Kim, Jong-Gyeum;Park, Young-Jeen;Lee, Eun-Woong;Lee, Jong-Han;Lee, Dong-Ju
    • Proceedings of the KIEE Conference
    • /
    • 2005.07b
    • /
    • pp.1062-1064
    • /
    • 2005
  • 3 phase 4-wire system has been widely used in the customer's application due to merit of 1 bank construction of loads such as 1-phase lighting, heat and 3-phase motor. But if the load distribution is not uniformed by the operation conditions, voltage unbalance is highly appeared by the difference of each phase current value. Especially, if the linear load such as resistance or inductive load has different power factor value, voltage unbalance factor is not the same due to the phase angle and magnitude of each phase voltage. In this paper, we composed the measurement device and analyzed by varying of load pattern.

  • PDF

Three Phase Drive Transfer Algorithm for Fault Tolerance Control of Six-Phase PMSM (6상 영구자석 동기전동기의 고장대응운전을 위한 3상 구동시스템 전환 알고리즘)

  • Kim, Seong-Hoon;Jang, Won-Jin;Cho, Kwan-Yuhl;Kim, Hag-Wone
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.26 no.4
    • /
    • pp.256-262
    • /
    • 2021
  • Six-phase motors can be used in industrial applications, such as an electric vehicle, due to their high reliability and low current magnitude per phase. An asymmetrical PMSM with two sets of three-phase windings is a commonly used structure for six-phase motors, with each winding set demonstrating a phase difference of 30°. Although the asymmetrical PMSM presents low torque ripples, its dynamic torque response deteriorates due to coupled components in the two three-phase windings. The decoupled VSD control is applied to eliminate the coupling effect. Load ratio control of two inverters for the six-phase PMSM is proposed in this study. DQ currents are controlled on the basis of two synchronous reference frames, and the six-phase drive system can be changed to a three-phase drive system when one inverter presents fault conditions. The operation and effectiveness of the proposed algorithm is verified through simulation and experiments. The six-phase drive system is transferred to a three-phase drive system by changing the current reference of the second DQ reference frame. Moreover, control of both torque and speed exhibits satisfactory performance before and after the mode change.

Daylight Observations of Venus with Naked Eye in the Goryeosa

  • Lee, Ki-Won
    • Journal of Astronomy and Space Sciences
    • /
    • v.34 no.1
    • /
    • pp.67-73
    • /
    • 2017
  • In this paper, we investigate the observations of Venus in daytime that are recorded in the Goryeosa (History of the Goryeo Dynasty, A.D. 918-1392). There are a total of 167 accounts of such observations in this historical book, spanning a period of 378 yr (from 1014 to 1392). These include six accounts where the days of the observation are not specified and two accounts where the phase angles are outside the calculation range of the equation used in our study. We analyze the number distribution of 164 accounts in 16 yr intervals covering the period from 1023 to 1391. We find that this distribution shows its minimum at around 1232, when the Goryeo dynasty moved the capital to the Ganghwa Island because of the Mongol invasion, and its maximum at around 1390, about the time when the dynasty fell. In addition, we calculate the azimuth, altitude, solar elongation, and apparent magnitude of Venus at sunset for 159 observations, excluding the eight accounts mentioned above, using the DE 406 ephemeris and modern astronomical algorithms. We find that the average elongation and magnitude of Venus on the days of those accounts were ${\sim}40^{\circ}$ and -4.5, respectively, whereas the minimum magnitude was -3.8. The results of this study are useful for estimating the practical conditions for observing Venus in daylight with the naked eye and they also provide additional insight into the corresponding historical accounts contained in the Goryeosa.

Sag & Swell Detection by Phase Voltage Compensation in 3-Phase Unbalanced Grid (3상 불평형 계통에서의 상 전압 보상을 통한 Sag 및 Swell 검출)

  • Kim, Min-Gi;Kim, Jun-Gu;Jung, Yong-Chae;Won, Chun-Yuen
    • Proceedings of the KIPE Conference
    • /
    • 2013.11a
    • /
    • pp.258-259
    • /
    • 2013
  • Load connection or disconnection makes instantaneous sag & swell in 3-phase grid. When unbalance state occurs, between sensed phase voltage and actual phase voltage may have discrepancy. It makes difficult to detect accurate sag & swell, so it is hard to satisfy the standard for switching ESS system to UPS mode. In this paper, we analyzed unbalanced 3-phase voltage, and compensated the actual sag & swell magnitude.

  • PDF

Effects of golf drive swing on multiple functional wear wearing (다기능성 웨어 착용이 골프 드라이브 스윙에 미치는 효과)

  • Kim, Jungwoo;Park, Sunkyung;Uh, Mikyung
    • The Research Journal of the Costume Culture
    • /
    • v.22 no.4
    • /
    • pp.632-639
    • /
    • 2014
  • The purpose of this study was to verify the effect of drive swing on multiple functional wear wearing in golf. The subjects were 6 men ($22.67{\pm}0.82$ yrs, $175.42{\pm}3.42cm$, $78.75{\pm}4.78kg$), who had career each with at least 8 yers golf experience with right-hander. For kinemetical analysis, this study used equipments with 7 motion capture cameras (300Hz) and analysis program (Nexus1.5). The total time of the club head, displacement magnitude of the COM and swing plane were compared of according to functional wear wearing and non-weraing during golf drive swing. The results of the study are as follows. The total time of the club on wearing ($2.18{\pm}0.06sec$) was faster than non-wearing ($2.52{\pm}0.15sec$). Displacement magnitude of the COM on wearing ($4.06{\pm}0.67cm$) was shorter than non-wearing ($5.79{\pm}0.72cm$). Also, swing plane was found to be significantly different of 3 phase excepted BST-DS (back swing top-down swing) phase. AD-BST (address-back swing top) phase on wearing ($13.86{\pm}3.08cm$) decrease more than non-wearing ($20.82{\pm}3.99cm$), DS-IP (down swing-impact) phase on wearing ($6.25{\pm}1.35cm$) decrease more than non-wearing ($7.18{\pm}1.52cm$) and IP-FT (impact-follow though) phase on wearing ($7.93{\pm}2.09cm$) decrease more than non-wearing($9.68{\pm}2.02cm$). The multiple functional wear wearing was contribution to come close for one-plane, a long with consistency and accuracy on golf drive swing.

Control Bandwidth Extension Method Based on Phase Margin Compensation for Inverters with Low Carrier Ratio

  • Wei, Qikang;Liu, Bangyin;Duan, Shanxu
    • Journal of Power Electronics
    • /
    • v.18 no.6
    • /
    • pp.1760-1770
    • /
    • 2018
  • This paper presents a control bandwidth extension method for inverters with a low carrier ratio. The bandwidth is extended at the price of decreasing the phase margin. Then the phase margin is compensated by introducing an extra leading angle into an inverse Park transformation. The model of the controller with the proposed method is established. The magnitude and phase characteristics are also analyzed. Then the influence on system stability when the leading angle is introduced is analyzed. The proposed method is applied to design an inverter controller with both a large bandwidth and a desired phase margin, and the experimental results verify that the controller performs well in the steady-state and in terms of transient response.

A.C. current control scheme for R-L load (R-L 부하에 대한 교류전류 제어방식)

  • 박민호;최규하
    • 전기의세계
    • /
    • v.29 no.12
    • /
    • pp.791-797
    • /
    • 1980
  • This paper is concerned with the study of improving the faults of phase control scheme and suggesting a new approach to the control of load circuit with AC source. AC current control can restrict the magnitude of current within the given upper and lower current and make current continuous during every cycle. Also the harmonic contents of current can be greatly reduced using this control scheme. Analog computer and digital computer simulations reveal that the current control scheme is superior to the phase control scheme in controlling the power supply to the load R-L. Experimintal results demonstrate the feasibility and verify the operation of current controlled system.

  • PDF

A Study on the Optimal Tuning of PID Controller (PID 제어기의 최적 동조)

  • 임동균;서병설
    • Journal of the Korean Institute of Telematics and Electronics B
    • /
    • v.30B no.11
    • /
    • pp.27-36
    • /
    • 1993
  • It is well know that the tuning method of Yuwana-Seborg (1982) can not be even applied to the relatively small delay system due to the phase errors from the Pad approximation suh (1984, 85, 86). Jutan and Rodriguez(1984), lee(1989), Chen(1989), Lee and Edgar(1990), etc have been tried to improve it. In this stydy, such recent results and their problems are investigated. A new tuning method by "a frequency scale transformation". which is based on a previous result of Suh(1984). is proposed. It can reduce the magnitude of the phase error significantly.

  • PDF