• 제목/요약/키워드: Phase Shift Method

검색결과 477건 처리시간 0.025초

전자 광학적 훌로그래픽 간섭법을 이용한 진동물체의 모드형태 계측법 (Measurement Method of the Vibration Mode Shapes Using Electro-Optic Holographic Interferometry)

  • 최장섭;강영준
    • 대한기계학회논문집A
    • /
    • 제20권2호
    • /
    • pp.564-574
    • /
    • 1996
  • This paper describes as Electronic Speckle Pattern Interferometry system which has been designed for measuring vibration patterns and quantitative measurement of vibration amplitude fields by using the time average method on a object. Visbility of fringe patterns is more improved by using the phase stepping and frame average method to reduce speckle and electric noise. And a bias vibration is introduced into the reference beam to shift the $\frac{2}{0}$ fringes so that fringe shift algorithms can be used to determine vibration amplitude. The experimental results are compared to those of the FFT analyzer and the FEM model analysis.

횡방향 주사를 이용한 광위상 간섭계의 페이즈 언래핑 향상에 대한 연구 (Phase unwrapping enhancement of phase shift interferometry by using lateral scanning)

  • 박도민;박성림;권대갑
    • 대한기계학회논문집A
    • /
    • 제22권3호
    • /
    • pp.684-687
    • /
    • 1998
  • The biggest problem common on to all forms of Phase Shift Interferometer is unwrapping the phase. Simple phase unwrapping algorithms assume that every pixel is within radians of its neighbors. If this is true, any reasonable algorithm will return the correct unwrapped phase. If not, correct unwrapped phase will not be obtained. In rough surface, frequently, neighboring pixels have phase steps greater than. This paper proposes the new method which makes phase steps smaller than by sub-pixel movement.

도플러 추정을 적용한 직접수열 대역확산 전송 기반 수중 이동통신 방법 및 가상 이동신호를 이용한 해상시험 결과 (Underwater mobile communication scheme based on the direct sequence spread spectrum transmission using Doppler estimation and its sea trial results with the pseudo-moving transmission)

  • 김승근
    • 한국음향학회지
    • /
    • 제41권1호
    • /
    • pp.16-29
    • /
    • 2022
  • 본 논문에서는 수중통신 장치가 수중에서 이동시 발생하는 도플러(Doppler) 편이를 극복하기 위한 도플러 편이 추정방법과 직접수열 확산대역 전송의 신호처리 방법을 제시한다. 제안한 방법은 도플러 편이에 강인하고, 자기 상관 특성이 우수한 64길이의 Frank 신호열을 두 번 반복하는 프리앰블을 사용하여 2단계로 도플러 편이를 추정한다. 또한, 제안한 방법을 직접수열 대역확산 전송을 사용하는 수중통신방식에 적용하여 수중이동통신용 패킷 설계와 RAKE 수신기를 설계한다. 설계한 확산대역 수중이동통신 변조방식은 데이터 심볼을 Differential-Quadrature Phase Shift Keying(DQPSK) 변조하여 수신시 위상추적이 필요 없고, RAKE 수신기에서 동위상 결합이 용이하게 할 수 있는 장점이 있다. 제안한 도플러 편이 추정방법을 포함하는 RAKE 수신방법은 약 17.5 m/s의 이동속도까지 가상으로 이동하는 송신기로부터 수신한 직접수열 대역 확산 신호를 성공적으로 수신한다.

ZVS 위상천이 풀브리지 컨버터의 소신호 모델링 및 디지털 제어기 설계 (ZVS Phase Shift Full-Bridge Converter's Small Signal Modeling and Digital Controller Design)

  • 김정우;조영훈;최규하
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2014년도 전력전자학술대회 논문집
    • /
    • pp.321-322
    • /
    • 2014
  • In this paper, a zero-voltage switching (ZVS) phase shift full-bridge converter is analyzed. The small-signal model is derived to design a digital controller. PLECS simulation shows how sampling method effects on transfer function of ZVS phase shift full-bridge converter.

  • PDF

진폭 변조 거리 측정 시스템에 적용 가능한 개선된 위상 추정 기법 (An Improved Phase Estimation Method for AM Range Measurement System)

  • 김대중;오택환;황선영
    • 한국통신학회논문지
    • /
    • 제37권6C호
    • /
    • pp.453-461
    • /
    • 2012
  • 본 논문에서는 진폭 변조 거리 측정 시스템에 적용 가능한 개선된 위상 추정 기법을 제안한다. 기존 위상 측정 방법은 이동 목표물의 도플러 천이에 의해 위상 측정 오차가 발생한다. 제안된 위상 추정 기법은 도플러 천이에 대해 적응 도플러 보정(Adaptive Doppler Correction)을 사용하여 위상 추정 오차를 보정하므로 거리 측정 정확도를 향상 시킬 수 있다. 모의실험 결과 도플러 주파수 천이 보정은 기존 방식보다 94.7% 향상된 성능을 보이며, 거리 측정 정확도는 50%로 향상되었다. 음향 수조에서는 오차가 7.7cm로 추정되어 해양 환경에서 음파를 이용하여 거리 추정에도 적용 가능함을 확인하였다.

Review on the Determination of Frumkin, Langmuir, and Temkin Adsorption Isotherms at Electrode/Solution Interfaces Using the Phase-Shift Method and Correlation Constants

  • Chun, Jinyoung;Chun, Jang H.
    • Korean Chemical Engineering Research
    • /
    • 제54권6호
    • /
    • pp.734-745
    • /
    • 2016
  • This review article described the electrochemical Frumkin, Langmuir, and Temkin adsorption isotherms of over-potentially deposited hydrogen (OPD H) and deuterium (OPD D) for the cathodic $H_2$ and $D_2$ evolution reactions (HER, DER) at Pt, Ir, Pt-Ir alloy, Pd, Au, and Re/normal ($H_2O$) and heavy water ($D_2O$) solution interfaces. The Frumkin, Langmuir, and Temkin adsorption isotherms of intermediates (OPD H, OPD D, etc.) for sequential reactions (HER, DER, etc.) at electrode/solution interfaces are determined using the phase-shift method and correlation constants, which have been suggested and developed by Chun et al. The basic procedure of the phase-shift method, the Frumkin, Langmuir, and Temkin adsorption isotherms of OPD H and OPD D and related electrode kinetic and thermodynamic parameters, i.e., the fractional surface coverage ($0{\leq}{\theta}{\leq}1$) vs. potential (E) behavior (${\theta}$ vs. E), equilibrium constant (K), interaction parameter (g), standard Gibbs energy (${\Delta}G_{\theta}{^{\circ}}$) of adsorption, and rate (r) of change of ${\Delta}G_{\theta}{^{\circ}}$ with ${\theta}$ ($0{\leq}{\theta}{\leq}1$), at the interfaces are briefly interpreted and summarized. The phase-shift method and correlation constants are useful and effective techniques to determine the Frumkin, Langmuir, and Temkin adsorption isotherms and related electrode kinetic and thermodynamic parameters (${\theta}$ vs. E, K, g, ${\Delta}G_{\theta}{^{\circ}}$, r) at electrode/solution interfaces.

A Novel Interleaving Control Scheme for Boost Converters Operating in Critical Conduction Mode

  • Yang, Xu;Ying, Yanping;Chen, Wenjie
    • Journal of Power Electronics
    • /
    • 제10권2호
    • /
    • pp.132-137
    • /
    • 2010
  • Interleaving techniques are widely used to reduce input/output ripples and to increase the power capacity of boost converters operating in critical conduction mode. Two types of phase-shift control schemes are studied in this paper, the turn-on time shifting method and the turn-off time shifting method. It is found that although the turn-off time shifting method exhibits better performance, it suffers from sub-harmonic oscillations at high input voltages. To solve this problem, an intensive quantitative analysis of the sub-harmonic oscillation phenomenon is made in this paper. Based upon that, a novel modified turn off time shifting control scheme for interleaved boost converters operating in critical conduction mode is proposed. An important advantage of this scheme is that both the master phase and the slave phase can operate stably in critical conduction mode without any oscillations in the full input voltage range. This method is implemented with a FPGA based digital PWM control platform, and tests were carried out on a two-phase interleaved boost PFC converter prototype. Experimental results demonstrated the feasibility and performance of the proposed phase-shift control scheme.

귀금속(Au, Rh) 전극계면에서 Langmuir 흡착등온식에 관한 위상이동방법 (The Phase-Shift Method for the Langmuir Adsorption Isotherms at the Noble Metal (Au, Rh) Electrode Interfaces)

  • 천장호;전상규;이재항
    • 전기화학회지
    • /
    • 제6권2호
    • /
    • pp.119-129
    • /
    • 2003
  • The Langmuir adsorption isotherms of the over-potentially deposited hydrogen (OPD H) fur the cathodic $H_2$ evolution reaction (HER) at the poly-Au and $Rh|0.5M\;H_2SO_4$ aqueous electrolyte interfaces have been studied using cyclic voltammetric and ac impedance techniques. The behavior of the phase shift $(0^{\circ}{\leq}{-\phi}{\leq}90^{\circ})$ for the optimum intermediate frequency corresponds well to that of the fractional surface coverage $(1{\geq}{\theta}{\geq}0)$ at the interfaces. The phase-shift profile $({-\phi}\;vs.\;E)$ for the optimum intermediate frequency, i.e., the phase-shift method, can be used as a new electrochemical method to determine the Langmuir adsorption isotherm $({\theta}\;vs.\;E)$ of the OPD H for the cathodic HER at the interfaces. At the poly-Au|0.5M $H_2SO_4$ aqueous electrolyte interface, the equilibrium constant (K) and the standard free energy $({\Delta}G_{ads})$ of the OPD H are $2.3\times10^{-6}$ and 32.2kJ/mol, respectively. At the poly-Rh|0.5M $H_2SO_4$ aqueous electrolyte interface, K and ${\Delta}G_{ads}$ of the OPD H are $4.1\times10^4\;or\;1.2\times10^{-2}$ and 19.3 or 11.0kJ/mol depending on E, respectively. In contrast to the poly-Au electrode interface, the two different Langmuir adsorption isotherms of the OPD H are observed at the poly-Rh electrode interface. The two different Langmuir adsorption isotherms of the OPD H correspond to the two different adsorption sites of the OPD H on the poly-Rh electrode surface.

소프트웨어 PLL 기반 소형 고속 BLDC의 속도 제어 (Software PLL Based Speed Control of High Speed Miniature BLDC)

  • 박태흡;석승훈;이동희;안진우
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 추계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.132-135
    • /
    • 2008
  • This paper presents a PLL(Phase Lock Loop) control method for speed control of high speed miniature BLDCM(Brushless DC Motor) using hall sensor. The Proposed PLL based speed control method uses a only phase shift between reference pulse signal according to speed reference and actual pulse signal from hall sensor. It doesn't use any speed calculation, and calculates a direct current reference from phase shift. The current reference is changed to reduce the phase shift between reference and actual pulse. So the actual speed can keep the reference speed. The proposed control scheme is very simple but effective speed control is possible.

  • PDF

DAB 컨버터의 전도 손실 저감을 위한 가변 주파수의 단일 위상 시프트 변조기법 (Single Phase-Shift Modulation with Variable-Frequency to Reduce Conduction Losses of DAB Converters)

  • 다오녹닷;이동춘
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2019년도 추계학술대회
    • /
    • pp.124-125
    • /
    • 2019
  • This paper proposes a novel control method to minimize conduction losses of dual active bridge (DAB) converters for on-board chargers of electric vehicles (EVs). In the control method, two variables are regulated, which are the phase-shift angle between the primary and secondary full bridges and the switching frequency. From time-domain analysis, an optimal phase-shift angle is derived to achieve the minimum RMS value of the transformer current. The proposed method was implemented for a 3.6-kW SiC-based prototype to validate its effectiveness. A high efficiency over 97.3% has been achieved for a wide output voltage range.

  • PDF