• Title/Summary/Keyword: Phase Seperation

Search Result 22, Processing Time 0.022 seconds

Study on the Separation of MAs from HLLW and Their Extraction Behavior Using New Extractants of Amido Podand

  • An, Ye-Guo;Luo, Fang-Xiang;Zhu, Zhi-Xuan;Zhang, Xiang-Ye;Zhu, Wen-Bin
    • Proceedings of the Korean Radioactive Waste Society Conference
    • /
    • 2004.02a
    • /
    • pp.245-256
    • /
    • 2004
  • The extraction of three kinds of amido podands, N,N,N'N'-tetrabutyl-3-oxa-pentanedi- amide (TBDGA), N,N,N'N'-tetra-isobutyl-3-oxa-pentanediamide(TiBDGA) and N,N,N'N'-tetra- butyl-3,6-dioxa-oct-anediam- ide(TBDOODA) on U(VI),Pu(IV), Am(III), Eu(III) and other metal ions is studied in nitric acid solutions. 40%octanol-kerosene is chosen as diluents to eliminate third phase and emulsion. TBDGA and TiBDGA show extraction selectivity to An(III) and Ln(III) much higher than to U(VI) and Pu(IV). Fe, Ru and Mo is poorly extracted by the three kinds of amid podands in 2~3mol/L $HNO_3$ solutions. Aiming to eliminate interface crude when using simulated HLLW solution in the system of 0.2mol/L TBDGA/Octanol+kerosene, acetohydroxyamic acid was adapted. Distribution ratio of zirconium was decreased when adding acetohydroxyamic acid in aqueous solution, and interface crude disappeared as mixing extractant with HLLW. The counter-current extraction test is carried out in a set of miniature mixer-settler, with 0.2mol/L TBDGA/ 40% octanol-kerosene as extractant to separate U(VI), Pu(IV), Am(III) and Eu(III) from simulated high level liquid waste(HLLW) solution. In battery A, lanthanides and actinides are coextracted into organic phase with the recovery of 99.98% for U(Ⅵ), >99.99% for Pu(IV), and >99.99% for Am(III) and Eu(III) respectively. In battery R1, 99.99% U, 86.2% Pu and a part of Am or Eu are stripped into aqueous phase by 0.2mol/L acetohydroxyamic acid (AHA) in 0.01mol/L $HNO_3$ solution. In battery $R_2$, Am, Eu and remained Pu are completely back-extracted by 0.2mol/L AHA. This separation process contains no salt reagent, and it is not necessary to dilute HLLW feed.

  • PDF

A study on production of early pregnancy diagnostic kit in cattle II. Production of early pregnancy diagnostic kit (소의 조기 임신진단 kit의 개발 II. 조기 임신진단 kit의 개발)

  • Kang, Chung-boo;Lee, Hyo-jong;Choe, Sang-yong
    • Korean Journal of Veterinary Research
    • /
    • v.31 no.2
    • /
    • pp.223-228
    • /
    • 1991
  • Most progesterone enzyme immunoassays(EIA) are used liquid-phase double-antibody or single-antibody seperation. These methods consume considerable time and reagents because of the requirements for several washing and centrifugation steps involving the reactants. Because of these several problems, we were prompted to develop an effective enzyme-linked immunosorbent assay(ELISA) system that would be equal or superior to RIA for assay of progesterone. The results were obtained as follows. 1. Cross reaction of the progesterone antiserum with other steroids determined was shown with progesterone(100%), $11{\alpha}$-deoxycorti-costerone(2.271%), but the other steroids were shown below 0.9%. 2. Standard curve for progesterone ELISA was shown available difference according to progesterone concentration from 0 to 1,000pg/ml. 3. The lower limit of sensitivity was 0.2pg/well 4. Progesterone concentration was 1.6ng/ml for before parturition, and that was below 0.5ng/ml for after parturition. This development enzyme-linked immunosorbent assay for progesterone can be detected pregnancy diagnosis in cattle, and also applicable 10 research on physiological function including such as reproductive disorders.

  • PDF

Comparison of Resveratrol and Oxyresveratrol Contents Among Varietes of Morus alba L. (뽕나무의 품종과 부위에 따른 Resveratrol 및 Oxyresveratrol의 함량비교)

  • Choi, Sang-Yoon;Lee, Kang-Jin;Kim, Sung-Soo;Kim, Sun-Yeou
    • Korean Journal of Medicinal Crop Science
    • /
    • v.13 no.4
    • /
    • pp.146-149
    • /
    • 2005
  • This study carried out to quantitatively analyze the content of resveratrol and oxyresveratrol in various parts and varieties of Morus alba L. The seperation of resveratrol and oxyresveratrol was performed using a reverse phase HPLC system. As the result, underground part of Morus alba L. contained higher concentration of resveratrol and oxyresveratrol compared with the other parts. Moreover, among the various Morus alba cortex species, Suwon and Shinil had the highest concentration of resveratrol and oxyresveratrol. Therefore, underground part of Suwon and Shinil species were most effective for extraction of resveratrol and oxyresveratrol.

Compatibility Study of HNBR/Silicone Rubber Blends (HNBR/Silicone 고무의 상용성에 관한 연구)

  • Oh, Taeg-Su;Ryou, Jin-Ho;Kim, Chang-Hee
    • Elastomers and Composites
    • /
    • v.31 no.2
    • /
    • pp.111-121
    • /
    • 1996
  • The characteristic of silicone rubber can be seen from its resistance to both low and high temperature, whereas HNBR is resistant only in high temperature moderatly although it can be compounded to give good tensile properties, good oil resistance while silicone rubber severely lacks in these qualities. This study was initiated a balance of properties by blending HNBR and silicone rubber which is not considered for commercial blending; blends of HNBR with silicone rubber tend to show immiscible due to dissimilar nature of silicone and HNBR, the possibility of phase separation cannot be ruled out, in unfilled system after vulcanisation leading to premature failure. Attempt has been made to improve compatibility and minimise the layer seperation by the use of compatibilizer. Both filled and unfilled systems, in presence and absence of compatibilizer have been studied. Improvement in tensile properties of the blends or are observed as compared to the non-blended rubber. Different ratios of HNBR and silicone rubber are represented in this study. Blends of HNBR with silicone rubber were immiscible system. The tensile strength increased with filler loading.

  • PDF

Detection and Measurement of Retinoic Acid in Human Liver Samples (간 조직내의 Retinoic Acid 검출 및 측정 방법)

  • 김초일
    • Journal of Nutrition and Health
    • /
    • v.24 no.3
    • /
    • pp.199-205
    • /
    • 1991
  • Retinoic acid. the active metabolite of vitamin A. was detected in the human liver for the first time using a new method. A rapid and sensitive technique has been developed using gradient-elution. reverse-phase high performance liquid chromatography. This assay. with simultaneous multiwavelength detection at 294nm, 325nm and 450nm after saponifcation of liver samples. allows us seperation and quantitation of vitamin E, retinoic acid, total retinoids and various carotenoids in one small sample. The proportion of retinoic acid to total retinoids in human liver appears to be quite $consistent(2.4\pm0.2%$ ). With low vitamin A storage in liver, detection at another wavelenth 354nm would increase the sensitivity for retinoic acid of small quantity This method of analysis could be used for other tissues like red blood cells, plasma or serum, also. Hepatic retinoic acid level with total retinoids and carotenoids would serve a better indicator of functional vitamin A nutriture especially for those with disease requiring needle biopsy of liver.

  • PDF

Influences of the Molar Ratio of $Mo/MoO_3$ on Characteristics of $MoSi_2-Al_2O_3$ composites by SHS Methods (연소합성법에 의한 $MoSi_2-Al_2O_3$ 복합재료의 특성에 미치는 $Mo/MoO_3$ 몰비의 영향)

  • 장윤식;이윤복;김용백;김인술;박흥채;오기동
    • Journal of the Korean Ceramic Society
    • /
    • v.33 no.11
    • /
    • pp.1209-1216
    • /
    • 1996
  • MoSi2-Al2O3 composites were prepared by thermal explosion mode of self-propagating high temperature syn-thesis (SHS) using element powders of MoO3 Mo Si and Al. The combustion products of MoSi2 which have 10, 20, 30 and 40 wt% Al2O3 showed the molten state in the range of Mo to MoO3 6:1-9.5:1, 2:1-8:1, 1:1-5:1, and 1:1-3:1 (molar ratio) respectively. The combustion products which made least seperation the molten phase from the slag phase were in Mo/MoO3=9, 5:1, 8:1, 5:1 and 3:1 (molar ratio) respectively. Particles size of MoSi2 and Al2O3 in the combustion product were decreased as the molar ratio of Mo to MoO3 increase. By XRD analysis only MoSi2 and $\alpha$-Al2O3 peaks were identified in the combusion products, In case of MoSi2 containing 20wt% Al2O3 5.1wt% Al existed into MoSi2 grains and 30.7wt% Si and 7.7wt% Mo existed into Al2O3 grains. The relative density of MoSi2 containing 10, 20, 30 and 40 wt% Al2O3 were 82.7, 85.2, and 81.9% respectively. The fracture strength of MoSi2-Al2O3 composites increased with increasing Al2O3 and that of MoSi2-20wt% Al2O3 composite was 195 MPa.

  • PDF

Development of Biomimetic Scaffold for Tissue Engineering (조직공학을 위한 생체모사용 스캐폴드 개발)

  • Park, Su-A;Lee, Jun-Hee;Kim, Wan-Doo
    • Elastomers and Composites
    • /
    • v.44 no.2
    • /
    • pp.106-111
    • /
    • 2009
  • Tissue engineering is a research field for artificial substitutes to improve or replace biological functions. Scaffolds play a important role in tissue engineering. Scaffold porosity and pore size provide adequate space, nutrient transportation and cell penetration throughout the scaffold structure. Scaffold structure is directly related to fabrication methods. This review will introduce the current technique of 3D scaffold fabrication for tissue engineering. The conventional technique for scaffold fabrication includes salt leaching, gas foaming, fiber bonding, phase seperation, melt moulding, and freeze drying. These conventional scaffold fabrication has the limitations of cell penetration and interconnectivity. In this paper, we will present the solid freeform fabrication (SFF) such as stereolithography (SLA), selective laser sintering (SLS), and fused deposition modeling (FDM), and 3D printing (3DP).

HPLC Analysis of Marker Substances in Taeumin Gamijowi-tang (태음인(太陰人) 가미조위탕(加味調胃湯)의 HPLC 분석)

  • Hwang, Young-Myung;Yu, Young-Beob;Kim, Jong-Youl;Koh, Byung-Hee;Lee, Eui-Ju
    • Journal of Sasang Constitutional Medicine
    • /
    • v.18 no.1
    • /
    • pp.147-154
    • /
    • 2006
  • 1. Objectives This study was aimed to evaluate marker substances in Gamijowi-tang by high performance liquid chromatography(HPLC) 2. Methods The seperation was performed an AquasilC18(4.6X250mm)column by gradient elution with 0.1N H3PO4 in H2O - acetonitrile(0min 100:10,20min60:40, 40min 80:20, 60min 100:0) as the mobile phase at a flow-rate of 1.0 ml/min with detection at 190-800nm 3. Results Ephedrine and schizandrin were established as marker substances in Gamijowi-tang and its qualitative analysis was carried out. Analyzed was similarity of marker substances between in standard article and in Gamijowi-tang. The result of the analysis was that ephedrine and schizadrin showed 0.9999 of similarity, which meant they were really ephedrine and schizadrin. In addition, ephedrin content was 12.16mg, pseudoephedrine conrenr was 5.09mg, and schizandrin content was 26.6mg in 76g of Gamijowi-tang. 4. Conclusions Qualitative and quantitative analyses of ephedrine and schizandrin in Gamijowi-tang were conducted, and it was identified thar they could be used as marker substances in standardizing quality of Gamijowi-rang.

  • PDF

Fracture Behaviour of Lubricants in ABS Terpolymer (ABS 중에 첨가된 저분자 화합물의 파단 거동에 미치는 영향)

  • Don, Yoon-Seung;Shim, Mi-Ja;Kim, Sang-Wook
    • Applied Chemistry for Engineering
    • /
    • v.5 no.5
    • /
    • pp.878-888
    • /
    • 1994
  • In order to investigate the fracture behavior of ABS terpolymer under the tension and impact load, varing the content of rubber, molecular weight of SAN, content and kinds of lubricant, tension speed, the mechanical properties were measured and SEM pictures of fracture area were taken. Under the tension, the tensile strength increased as rubber content and lubricant content decreased, while molecular weight and tension speed increased. The deformation of area near fracture site did not occur as rubber content, tension speed and molecular weight decreased and liquid lubricant was used. And in the shape of fracture seemed phase seperation. Under the impact load, the notched izod impact strength increased as rubber content, molecular weight, ambient temperature and lubricant content increased. In the SEM picture, the strength was high white the fracture surface was small.

  • PDF

Spectroscopic Imaging at 1.0Tesla MR Unit (1.0Tesla 자기공명 영상장치에서의 분광영상기법에 관한 연구)

  • Yi, Y.;Ryu, T.H.;Oh, C.H.;Ahn, C.B.;Lee, H.K.;Cho, Z.H.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1997 no.11
    • /
    • pp.517-527
    • /
    • 1997
  • Magnetic Resonance Spectroscopic Imaging is a methodology combining the imaging and spectroscopy. It can provide the spectrum of each areas of image so that one can easily compare the spectrum of one position to another position of the image. In this study, we developed pulse sequence or the spectroscopic imaging method, RF wave forms or the saturation of water signal, computer simulations to validate our method, and confirmed the methodology with phantom experiment. Then we applied the spectroscopic method to human subject and identified a few important metabolites in in vivo. To develope a water saturating RF waveform, we used Shinnar-Le-Roux algorithm and obtained maximum phase RF waveform. With this RF pulse, it could suppress the water signal to 1:1000. The magnet is shimmed to under 1.0ppm with auto-shimming technique. The saturation bandwidth is 80Hz(2ppm). The water and fat seperation is 3.3ppm(about 140Hz at 1 Tesla magnet), the bandwidth is enough to resolve the difference. But we are more concerned about the narrow window in between the two peaks, in which the small quantity of metabolites reside. We performed the computer simulation and phantom experiments in 8*8 matrix form and showed good agreement in the image and spectrum. Finally we applied spectroscopic imaging to the brain of human subject. Only the lipid signal was shown in the periphery region which agrees with the at distribution in human head surface area. The spectrum inside the brain shows the important metabolites such as NAA, Cr/PCr, Choline. We here have shown the spectroscopic imaging which is normally done above 1.5 Tesla machine can be performed in the 1 Tesla Magnetic Resonance Imaging Unit.

  • PDF