• Title/Summary/Keyword: Pet management system

Search Result 47, Processing Time 0.025 seconds

A Comparative Study of the Standard Uptake Values of the PET Reconstruction Methods; Using Contrast Enhanced CT and Non Contrast Enhanced CT (PET/CT 영상에서 조영제를 사용하지 않은 CT와 조영제를 사용한 CT를 이용한 감쇠보정에 따른 표준화섭취계수의 비교)

  • Lee, Seung-Jae;Park, Hoon-Hee;Ahn, Sha-Ron;Oh, Shin-Hyun;NamKoong, Heuk;Lim, Han-Sang;Kim, Jae-Sam;Lee, Chang-Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.12 no.3
    • /
    • pp.235-240
    • /
    • 2008
  • Purpose: At the beginning of PET/CT, Computed Tomography was mainly used only for Attenuation Correction (AC), but as the performance of the CT have been increase, it could give improved diagnostic information with Contrast Media. But it was controversial that Contrast Media could affect AC on PET/CT scan. Some submitted thesis' show that Contrast Media could overestimate when it is for AC data processing. On the contrary, the opinion that Contrast Media could be possible to affect the alteration of SUV because of the overestimated AC. But it does not have a definite effect on the diagnosis. Thus, the affection of Contrast Media on AC was investigated in this study. Materials and Methods: Patient inclusion criteria required a history of a malignancy and performance of an integrated PET/CT scan and contrast- enhanced CT scan within a 1-day period. Thirty oncologic patients who had PET/CT scan from December 2007 to June 2008 underwent staging evaluation and met these criteria. All patients fasted for at least 6 hr before the IV injection of approximately 5.6 MBq/kg (0.15 mCi/kg) of $^{18}F$-FDG and were scanned about 60 min after injection. All patients had a whole body PET/CT performed without IV contrast media followed by a contrast-enhanced CT on the Discovery STe PET/CT scanner. CT data were used for AC and PET images came out after AC. The ROIs drew and measured SUV. A paired t-test of these results was performed to assess the significance of the difference between the SUV obtained from the two attenuation corrected PET images. Results: The mean and maximum Standardized Uptake Values (SUV) for different regions averaged over all Patients. Comparing before using Contrast Media and after using, Most of ROIs have the increased SUV when it did Contrast Enhanced CT compare to Non-Contrast enhanced CT. All regions have increased SUV and also their p value was under 0.05 except the mean SUV of the Heart region. Conclusion: In this regard, the effect on SUV measurements that occurs when a contrast-enhanced CT is used for attenuation correction could have significant clinical ramifications. But some submitted thesis insisted that the percentage change in SUV that can determine or modify clinical management of oncology patients is small. Because there was not much difference that could be discovered by interpreter. But obviously the numerical change was occurred and on the stage finding primary region, small change would be base line, such as the region of liver which has greater change than the other regions needs more attention.

  • PDF

Development of Smart Pet House with AI Function (AI 기능을 탑재한 스마트 반려동물 하우스 개발)

  • Song, Soon-Myung;Park, Soo-Yong;Jo, Eun-Hyeon;Lee, Dong-Hyung
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.42 no.2
    • /
    • pp.86-93
    • /
    • 2019
  • The population of domestic companion animals is estimated to be about 10 million now. In recent years, the domestic pet market has been launching a wide range of products and services for high quality, smart and well-being. As a result, the market size will increase from 900 billion won in 2012 to 2.3 trillion won in 2016, which has more than doubled in five years. The industry expects to reach 6 trillion won by 2020, expecting 3 trillion won this year. In particular, domestic dogs and cats market is estimated at 275.5 billion won, accounting for 19% of the domestic animal market and 1.425 billion won for the world market. However, despite the growing market for companion animals products, unfortunately the import dependence on related industrial goods is still high and the quality of service is very low. Unlike Europe and the United States, 90% of companion animals are housed in apartments, often causing problems in the health and safety of companions and companions. The purpose of this study is to develop a smart house for companion animals with environmental friendliness and AI function that can be won in competition with products of developed countries. The results of this study are expected to contribute to the creation of a new value - added base for the related industries through the strengthening of the competitiveness of the related SMEs and further the effect of employment increase and import substitution.

Classification of submitted nuclear medicine dissertation and directional consideration (핵의학 투고 논문 분류 및 방향성 고찰)

  • Ho-Yeon, Cho;Yeong-Ran, Woo;Kang-Rok, Seo;Gun-Chul, Hong
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.26 no.2
    • /
    • pp.37-42
    • /
    • 2022
  • Purpose Since 1985, the Korean society of nuclear medicine technology (KSNMT) has been engaged in academic activities related to nuclear medicine imaging. From 2017 to 2021, the papers published in the journal were classified by the specific fields to examine the trends in the research and the direction of nuclear medicine in comparison with the papers submitted to the Korean Society of Nuclear Medicine (KSNM) during the same period. Materials and Methods From 2017 to 2021, papers submitted to KSNMT and KSNM were classified and databaseization using the Excel program by submission type, examination equipment, and examination field. Through this data, the number of papers published in journals by year, the number of papers submitted by detailed fields, and key words by era were analyzed and compared. Results The papers included by journal was 57 KSNMT and 280 KSNM. The major large classification of equipment, PET, Planar and SPECT was 26.3%, 21.1%, 19.3% in the KSNMT, KSNM was 49.6%, 6.4%, and 9.3%, with 66.7% and 65.3%, respectively. the major medium classification of equipment, industrial safety, urogenital system, nervous system, and quality control accounted for 54.4% of the total papers of the total ratio in the KSNMT, while the medium classification of oncology, endocrine system, urogenital system, therapy, and nervous system accounted for 61.1% of KSNM. In the major small classification of image acquisition, improvement effect, and exposure management accounted for 70.2% in KSNMT, while the items of image acquisition, report, and improvement effect accounted for 60.7% in KSNM. The major keywords except for equipment-related keywords such as PET/CT, PET/MR, and SPECT were SUV, Planar Image, and Respiration Gating Method in KSNMT and Ga68, Thyroid, and Lymphoma in the KSNM. Conclusion When checking the last 5 years of submissions, we can see that KSNMT is mainly concerned with image acquisition using existing radiotracers, while KSNM has focused on new radiotracers such as 68Ga, 177Lu, etc., and new medical technologies of theranostic. It has been confirmed that more PET-related papers than other examination equipment will account for a greater number of papers, and it is believed that future submissions will also account for a higher proportion of PET-related papers than other equipment.

The latest development in Dementia (치매에 관한 최근의 연구 동향)

  • Na, Chang-Su;Kim, Jeong-Sang;Chae, U-Seok;Park, Seok-Cheon
    • The Journal of Internal Korean Medicine
    • /
    • v.19 no.1
    • /
    • pp.291-300
    • /
    • 1998
  • Dementia is the neurodegenerative process that affects cognition, behavior and function and one of the most prominent diseases of dementia is Alzheimer's disease(AD). AD is a dementing illness characterized clinically by the progressive and irreversible deafferentation of the limbic system, association neocortex and basal forebrain. A number of conditions are known to be predisposing risk factors for AD. In several of these, initiation of glial-mediated inflammatory pathways as a mechanism of AD is getting a lot of attention. On the other hand, a biochemical marker for monitoring the onset and progression of the disease would be a valuable tool for disease management. Also such a marker might be used as an end point in clinical intervention protocols. This biochemical marker will have the potential for identifying subjects afflicted with the disease and possibly for monitoring the onset and longitudinal progression of the disease. Here we have reviewed the latest papers of different approaches to AD. Of course, there is a section of PET which is very useful clinically nowadays.

  • PDF

A Study on Dose Assessment by 18F-FDG injected into Patients (환자에게 주입된 18F-FDG 의한 선량 평가에 대한 연구)

  • Kim, Chang-Ju;Kim, Jang-Oh;Jeong, Geun-Woo;Shin, Ji-Hey;Lee, Ji-Eun;Jeon, Chan-Hee;Min, Byung-In
    • Journal of the Korean Society of Radiology
    • /
    • v.14 no.4
    • /
    • pp.467-475
    • /
    • 2020
  • The purpose of this study is to assess doses to 18F-FDG, a radioactive drug, during PET examinations, to alleviate anxiety about radiation in patients and carers, to minimize the indiscriminate examination progress caused by medical institution personnel and space clearance problems, and health examination. The dose assessment was measured using a thermo-fluorescent dosimeter (TLD) and an electronic personal dosimeter (EPD) at the location of the cervical (hypothyroid), thorax (heart), and lower abdomen (breeding line) which are the three highest tissue areas of the radiation tissue weighting. In addition, spatial dose rates and radioactivity in urine were measured using GM counters and ion boxes. The results are as follows: First, the personal dosimeter TLD was measured 0.0425±0.0277 mSv in the cervical region, 0.0440±0.0386 mSv in the thorax and 0.0485±0.0436 mSv in the lower abdomen, with little difference in the heart dose depending on radiation sensitivity. The EPD was measured at 0.942±0.141 mSv/h immediately after the cervical position, and 0.192±0.031 mSv/h after 120 minutes. Immediately after the thorax position, 0.516±0.085 mSv/h, 120 minutes later 0.128±0.040 mSv/h. Immediately after the lower abdomen position, 0.468±0.091 mSv/h, and after 120 minutes 0.105±0.021 mSv/h were measured. The spatial dose rate at the GM counter was measured immediately at 0.041±0.005 mSv/h, 120 minutes later at 0.014±0.002 mSv/h. The radioactivity in urine using ion chamber was measured at 0.113±0.24 MBq/cc after 60 minutes and 0.063±0.13 MBq/cc after 120 minutes. As a result, 18F-FDG should be administered, dose re-evaluated two hours after the PET test is completed, and caregivers should be avoided. In addition, it is deemed necessary to provide patients and carers with sufficient explanations and expected values of exposure dose to avoid reckless testing. It is hoped that the data tested in this study will help patients and families relieve anxiety about radiation, and that the radiation workers' exposure management system and institutional improvements will contribute to the development of medical radiation.

Breeding Status and Management System Improvement of Pseudemys concinna and Mauremys sinensis Designated as Invasive Alien Turtles in South Korea (법적지정 생태계교란생물의 사육 현황과 관리 개선 방안 - 리버쿠터와 중국줄무늬목거북을 중심으로)

  • Kim, Philjae;Yeun, Sujung;An, Hyeonju;Kim, Su Hwan;Lee, Hyohyemi
    • Ecology and Resilient Infrastructure
    • /
    • v.7 no.4
    • /
    • pp.388-395
    • /
    • 2020
  • Exotic species have been imported for economic purposes, but more recently, an increasing number of animals are imported as pets. With the increasing popularity of two species of turtles, Mauremys sinensis and Pseudemys concinna, the number of pet turtle owners has gradually increased since 2014. The number of turtles increased by 180 in 2017 and 281 in 2019. However, these turtle species have been abandoned to nature, owing to their long lifespans and the changes in conditions of pet owners. The two turtle species have been designated as invasive alien species (AIS) in Korea considering their ecological risks, and the Biological Diversity Act prohibits their release. The owners of Mauremys sinensis and Pseudemys concinna are required to submit the "Application for Approval of Breeding and Grace for AIS" document. In this study, the breeding conditions for the two turtle species were investigated by analyzing the information in the submitted applications for six months (e.g., the suitability of breeding facilities, number of turtles, breeding period, type of pet adoption, and local district of pet owner). A total of 614 cases were analyzed. Because only 58% of breeders provided suitable breeding conditions, breeding information and responsible pet ownership training should be offered to prevent abandonment in natural ecosystems. In addition, continuous monitoring is necessary to prepare for potential problems caused by the lack of information in many applications and the one-off licensing policy.

A Study on Virtual Reality Management of 3D Image Information using High-Speed Information Network (초고속 정보통신망을 통한 3차원 영상 정보의 가상현실 관리에 관한 연구)

  • Kim, Jin-Ho;Kim, Jee-In;Chang, Chun-Hyon;Song, Sang-Hoon
    • The Transactions of the Korea Information Processing Society
    • /
    • v.5 no.12
    • /
    • pp.3275-3284
    • /
    • 1998
  • In this paper, we deseribe a Medical Image Information System. Our system stores and manages 5 dimensional medical image data and provides the 3 dimensional medical data via the Internet. The Internet standard VR format. VRML(Virtual Reality Modeling Language) is used to represent the 3I) medical image data. The 3D images are reconstructed from medical image data which are enerated by medical imaging systems such ans CT(Computerized Tomography). MRI(Magnetic Resonance Imaging). PET(Positron Emission Tomograph), SPECT(Single Photon Emission Compated Tomography). We implemented the medical image information system shich rses a surface-based rendering method for the econstruction of 3D images from 2D medical image data. In order to reduce the size of image files to be transfered via the Internet. The system can reduce more than 50% for the triangles which represent the surfaces of the generated 3D medical images. When we compress the 3D image file, the size of the file can be redued more than 80%. The users can promptly retrieve 3D medical image data through the Internet and view the 3D medical images without a graphical acceleration card, because the images are represented in VRML. The image data are generated by various types of medical imaging systems such as CT, MRI, PET, and SPECT. Our system can display those different types of medical images in the 2D and the 3D formats. The patient information and the diagnostic information are also provided by the system. The system can be used to implement the "Tele medicaine" systems.

  • PDF

The Evaluation of a Plastic Material Classification System using Near Field IR (NIR) Spectrum and Decision Tree based Machine Learning (Near Field IR (NIR) 스펙트럼 및 결정 트리 기반 기계학습을 이용한 플라스틱 재질 분류 시스템)

  • Kook, Joongjin
    • Journal of the Semiconductor & Display Technology
    • /
    • v.21 no.3
    • /
    • pp.92-97
    • /
    • 2022
  • Plastics are classified into 7 types such as PET (PETE), HDPE, PVC, LDPE, PP, PS, and Other for separation and recycling. Recently, large corporations advocating ESG management are replacing them with bioplastics. Incineration and landfill of disposal of plastic waste are responsible for air pollution and destruction of the ecosystem. Because it is not easy to accurately classify plastic materials with the naked eye, automated system-based screening studies using various sensor technologies and AI-based software technologies have been conducted. In this paper, NIR scanning devices considering the NIR wavelength characteristics that appear differently for each plastic material and a system that can identify the type of plastic by learning the NIR spectrum data collected through it. The accuracy of plastic material identification was evaluated through a decision tree-based SVM model for multiclass classification on NIR spectral datasets for 8 types of plastic samples including biodegradable plastic.

Classification of submitted KSNMT dissertation (대한핵의학기술학회 투고 논문 분류)

  • Han, Dong-Chan;Lee, Hyuk;Hong, Gun-Chul;Ahn, Byeong-Ho;Choi, Seong-Wook
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.21 no.1
    • /
    • pp.65-69
    • /
    • 2017
  • Purpose KSNMT(Korea Society of Nuclear Medicine Technology) stepping first step in 1997, has published first journal related with nuclear medicine technology in 1985. With classifying In Vivo Session Dissertation reported in the entire journal, trend of the Dissertation will be studied. Materials and Methods Dissertations which published from 1985 to first half of 2016 in the journal are classified with presentation form and with scanner, And all the data is organized with Excel program. Through the data, the number of dissertations published in each year, the number of dissertation published in details, and keyword distributions in each period are analyzed. Results The number of In-vivo section dissertations was 1151 and the number of In-vivo section dissertations that have common subject with In-vitro section was 28. The number of In-vivo section dissertation in 1980s was 46, in 1990s was 149, in 2000 was 467 and from 2010 to the first half of 2016 was 517. The number of dissertation with original articles was 571, with abstract was 529, with symposium was 31, with special lecture was 25, with review was 11, with interesting image was 7, with poster was 3 and with case report was 2. With symposium and special lecture excluded, which count 56, the number of dissertation with PET was 319, with Planar was 302, with SPECT was 172, with radiopharmaceutical was 113, with guard and safety management 103, with BMD was 28, etc. was 86. The number of dissertation about oncology was 201, about scanner was 179, about cardiovascular and circulatory system was 102, about safe environment was 82, about musculoskeletal system was 76, about nervous nuclear medicine was 66, about quality assurance was 61, about genitourinary system was 56, about endocrine system was 49, about digestive system was 44, about Therapy, about industrial safety was 24, about molecular imaging was 15, infection and inflammation was 9, about respiratory system was 8 and etc. was 108. The mostly used keyword through 1999 to 2005 was PET and through 2006 to 2016 was PET/CT. Conclusion To encourage various dissertations to be submitted, Korea Society of Nuclear Medicine should analyze date about not only about dissertations that are already published, but also about various research materials. Moreover, Korea Society of Nuclear Medicine also have to provide technical support such as sharing big data from homepage and systematical support to its member to publish dissertation that has high impact factor. It is important each individual researcher to have continuing effort as well as each organization cooperation.

  • PDF

Technical Protection Measures for Personal Information in Each Processing Phase in the Korean Public Sector

  • Shim, Min-A;Baek, Seung-Jo;Park, Tae-Hyoung;Seol, Jeong-Seon;Lim, Jong-In
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.3 no.5
    • /
    • pp.548-574
    • /
    • 2009
  • Personal information (hereinafter referred to as "PI") infringement has recently emerged as a serious social problem in Korea. PI infringement in the public and private sector is common. There were 182,666 cases of PI in 2,624 public organizations during the last three years. Online infringement cases have increased. PI leakage causes moral and economic damage and is an impediment to public confidence in public organizations seeking to manage e-government and maintain open and aboveboard administration. Thus, it is an important matter. Most cases of PI leakage result from unsatisfactory management of security, errors in home page design and insufficient system protection management. Protection management, such as encryption or management of access logs should be reinforced urgently. However, it is difficult to comprehend the scope of practical technology management satisfied legislation and regulations. Substantial protective countermeasures, such as access control, certification, log management and encryption need to be established. It is hard to deal with the massive leakage of PI and its security management. Therefore, in this study, we analyzed the conditions for the technical protection measures during the processing phase of PI. In addition, we classified the standard control items of protective measures suited to public circumstances. Therefore, this study provides a standard and checklist by which staff in public organizations can protect PI via technical management activities appropriate to laws and ordinances. In addition, this can lead to more detailed and clearer instructions on how to carry out technical protection measures and to evaluate the current status.