• Title/Summary/Keyword: Permeable design

Search Result 123, Processing Time 0.03 seconds

Establishment of Design Factors and Procedure for Permeable Asphalt Pavements Structural Design (투수성 아스팔트 포장 구조설계를 위한 설계인자 도출 및 설계방법에 관한 연구)

  • Yoo, Hyun Woo;Oh, Jeongho;Jung, Young Wook;Han, Shin In
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.38 no.1
    • /
    • pp.113-119
    • /
    • 2018
  • An extensive effort is actively being made to implement permeable pavement systems in urban or residential areas of South Korea in order to achieve efficient water circulation system based on low impact development (LID) design concept. This study aims to establish the design factors and procedure for permeable asphalt pavements structural design. Based on the review of previous studies, the 1993 AASHTO design method is found to be adequate for permeable pavements structural design. In this study, the design program based on 1993 AASHTO design procedure in conjunction with domestic roadway design standards was developed to accommodate the characteristics of permeable asphalt pavements. Primary design parameters such as structural layer coefficients of permeable materials were successfully quantified based on literature reviews and parallel analyses. Comparable design thicknesses were obtained between the developed permeable pavement design (PPD) program and Korea pavement research program (KPRP) under different levels of traffic and subgrade load bearing capacity.

Elastic Modulus and Layer Coefficient of Permeable Block Pavements Based on Plate Load Tests (평판재하시험을 통한 투수 블록포장의 탄성계수 및 상대강도계수 산정)

  • Choi, Yong-Jin;Oh, Jeong-Ho;Han, Shin-In;Ahn, Jaehun;Shin, Hyun-Suk
    • Journal of the Korean Geotechnical Society
    • /
    • v.33 no.12
    • /
    • pp.75-80
    • /
    • 2017
  • Permeable block pavement systems are widely used to relieve the flood and enhance water circulation. However, domestic design method has not yet been established well. Although AASHTO 93 flexible pavement design method is applied as a structural design method outside the country, there is a lack of information on layer coefficient of the permeable pavement materials, which makes it difficult to apply the design to various materials. Therefore, in this study, a method of calculating the layer coefficient of permeable block pavement materials by plate load test was presented and the layer coefficient of a permeable block pavement in a testbed was evaluated. Overall, calculated layer coefficient of open graded aggregate and permeable block pavement surface layer were similar to those of the conventional values. The presented method may be used to evaluate layer coefficients of permeable block pavements for design.

Design and Control of X-ray Permeable Teleoperated Stewart Platform for Fracture Surgery (골절 수술용 엑스레이 투과 원격조종 스튜어트 플랫폼의 설계 및 제어)

  • Yoo, Byeongjun;Kim, Hyemi;Lee, Sung-Hak;Lim, Sunho;Park, Tae Gon;Lee, Chibum
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.24 no.6
    • /
    • pp.660-666
    • /
    • 2015
  • To avoid radiation exposure from repeated x-rays taken during orthopedic surgery, an x-ray permeable teleoperated Stewart platform for orthopedic fracture surgery was developed. This system is composed of a user interface device and a teleoperated operational robot, both of which use a Stewart platform mechanism. The links of the operational robot are made from an x-ray permeable material, polycarbonate, to minimize the interference. The forward and inverse kinematics algorithm applied and the structural reliability were both verified through an analysis using commercial engineering software. To monitor the operating status in real time and stop the device during an emergency, a monitoring software was developed. The performance of the x-ray permeable teleoperated Steward platform was validated experimentally.

An Experimental Study of Permeable Concrete Pavement for Practical Use in the Field

  • Kim, Seong-Soo;Jung, Ho-Seop;Moon, Han-Young
    • International Journal of Concrete Structures and Materials
    • /
    • v.19 no.1E
    • /
    • pp.17-23
    • /
    • 2007
  • In rainy weather, permeable concrete pavement has advantages such as good drainage, increased skid resistance, reduced splash and spray behind vehicles for improving the safety of driving vehicles as well as reduction of the traffic noise. It also contributes to improvement of traffic environment. In this study, the fundamental properties of permeable concrete in accordance with maximum size of aggregate, sand percentage and unit cement content were investigated for practical use of permeable concrete pavement. Although the permeability standard for typical permeable asphalt-concrete pavement is $1{\times}10^{-2}cm/sec$, the researchers determined that the coefficient of permeability of the permeable concrete should be set higher at $1{\times}10^{-1}cm/sec$. Then, the researchers measured the coefficient of permeability, strength, void ratio, and continuous void ratio of the permeable concrete while varying maximum size of the aggregate, sand percentage, unit cement content for detailed analysis. It was found that the void ratio, continuous void ratio, and flexural strength were about 15%, 12%, and 5.0MPa, respectively, when the permeability of the concrete was set at $1{\times}10^{-1}cm/sec$. Given that the maximum size of aggregate was $10{\sim}13mm$, we reached the conclusion that the best mix design for permeable concrete was $0{\sim}20%$ of sand percentage and $380kg/m^3$ of unit cement content.

A Study on the Inverse Shape Design of a Turbine Cascade Using the Permeable Boundary Condition and CFD (침투경계조건과 CFD를 이용한 터빈 역형상 설계에 관한 연구)

  • Lee, Eun-Seok;Seol, Woo-Seok
    • Proceedings of the KSME Conference
    • /
    • 2007.05b
    • /
    • pp.3116-3121
    • /
    • 2007
  • In this paper, the inverse shape design is introduced using the permeable wall boundary condition. Inverse shape design defines the blade shape for the prescribed Mach numbers or pressure distribution on its surface. It calculates the normal mass flux from the difference between the calculated and prescribed pressure at the surface. A new geometry can be achieved after applying the quasi one-dimensional continuity equation from the leading edge to the trailing edge. For validation of this method, two test cases are studied. The first test case of inverse shape design illustrates the cosine bump with a strong shock. After seven geometry modifications, the shock-free bump geometry can be obtained. The second example concerns the redesign of a transonic turbine cascade. The initial isentropic Mach distribution has a peak on the upper surface. The target isentropic Mach number distribution was imposed smoothly. The peak of Mach distribution has disappeared at the final geometry. This proposed inverse design method has proven to be an efficient and robust tool in turbomachinery design fields.

  • PDF

Engineering Properties of Permeable Polymer Concrete for Pavement using Powdered Waste Glass and Recycled Coarse Aggregate (폐유리분말과 재생골재를 사용한 포장용 투수성 폴리머 콘크리트의 공학적 성질)

  • Sung, Chan-Yong;Kim, Tae-Ho
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.53 no.6
    • /
    • pp.59-65
    • /
    • 2011
  • This study was performed to evaluate the compressive and flexural strength, void ratio and permeability coefficient used powdered waste glass, $CaCO_3$, recycled coarse aggregate and unsaturated polyester resin to find optimum mix design of permeable polymer concrete for pavement. The compressive and flexural strength of permeable polymer concrete for pavement using powdered waste glass were in the range of 16.8~19.7 MPa and 4.7~6.1 MPa, respectively. it was satisfied the regulation of permeable concrete for pavement (18 MPa and 4.5 MPa). The void ratio and permeability coefficient were decreased with increasing the powdered waste glass, respectively. The void ratio and permeability coefficient were satisfied national regulation of permeable concrete for pavement (8 % and $1{\times}10^{-2}$ cm/s). In addition, this study found out that required amount of binder was decreased with increasing the powdered waste glass. This fact is expected to have economical effects during the use of powdered waste glass in the manufacture of permeable polymer concrete for pavement. Accodingly, the powdered waste glass can be used for permeable concrete material.

Sound Absorption Characteristics of Permeable Membrane (통기성을 갖는 막재료의 흡음특성)

  • Jeong, Jeong-Ho;Kim, Jung-Joong;Kim, Ku-Je
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2009.10a
    • /
    • pp.270-275
    • /
    • 2009
  • Sound absorption characteristics of membrane system which are used in stadiums and arenas were investigated. Theoretical studies on acoustic properties of single and double leaf permeable membrane conducted. Also, experimental studies on sound absorption characteristics of combined membrane system that is composed of outer and inner membrane material were conducted. In this study, sound absorption characteristics of each membrane were investigated by experiments in reverberation chamber. 4 types of permeable membranes and a non-permeable membrane were used for experiments. Air space behind membrane material and tension on the membrane was varied. Sound absorption performance of permeable membrane materials was confirmed. As increasing air space behind the membrane material, sound absorption coefficient was increased. In a resonance absorption frequency band sound absorption coefficient varied more dramatically. Sound absorption characteristics were flat in mid and high frequency range and sound absorption coefficient was from 0,3 to 0,5. Also sound absorption coefficient was increased by the increment of surface density and air permeability of membrane. However, over the certain value of air permeability, sound absorption coefficient was decreased. These results can be used as design factors and method for the room acoustic design of dome-stadiums and large free-form buildings.

  • PDF

Engineering Characteristics of Permeable Mortar using Water-Quenched Blast Furnace Slag as Eine Aggregates (고로급냉슬래그를 활용한 투수성 모르타르의 공학적 특성에 관한 기초연구)

  • 방윤경;박재로
    • Journal of the Korean Professional Engineers Association
    • /
    • v.33 no.4
    • /
    • pp.77-83
    • /
    • 2000
  • In this study, engineering characteristics of permeable mortar using water-quenched blast furnace slag as fine aggregates were analyzed by laboratory experiments to examine its suitability for permeable concrete pavement techniques. Engineering characteristics of mortar were investigated by performing both the compressive, flexural strength tests together with the constant head permeability tests for twenty-six types of mixing samples having different percetage of slag, cement and water. After 28days of curing, every performance was tested to find optimum mixture. When the go coefficient of permeability was 10$\^$-2/cm / sec and flexural strength was 30kg/㎠, we conclusion that the best mix design in permeable mortar was made in the condition,60% of cement and 20% of water percentage of unit slag contents. From the present investigations, it is concluded that suitability for permeable concrete pavement techniques using water-quenched blast furnace slag as fine aggregates may possibly be used to achieve effects on strength together with drainage effects.

  • PDF

Engineering properties of permeable polymer concrete for pavement using powdered waste glass as filler (폐유리분말을 충전재로 사용한 포장용 투수성 폴리머 콘크리트의 공학적 성질)

  • Sung, Chan-Yong;Kim, Tae-Ho
    • Korean Journal of Agricultural Science
    • /
    • v.38 no.1
    • /
    • pp.145-151
    • /
    • 2011
  • This study was performed to evaluate the void ratio, compressive and flexural strength, and permeability coefficient used powdered waste glass, $CaCO_3$, recycled coarse aggregate and unsaturated polyester resin to find optimum mix design of permeable polymer concrete for pavement. The void ratio and permeability coefficient of permeable concrete for pavement was decreased with increasing the powdered waste glass, respectively. The compressive strength and flexural strength was increased with increasing the powdered waste glass, respectively. In addition, this study found out that required amount of binder was decreased with increasing the powdered waste glass. This fact is expected to have economical effects during the use of powdered waste glass in the manufacture of permeable polymer concrete for pavement. Therefore, powdered waste glass and recycled coarse aggregate can be used for permeable polymer pavement.

Experimental Study on Rainfall Runoff Reduction Effects by Permeable Polymer Block Pavement (투수성 폴리머 블록 포장에 의한 우수 유출 저감 효과에 관한 실험적 연구)

  • Sung, Chan-Yong;Kim, Young-Ik
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.54 no.2
    • /
    • pp.157-166
    • /
    • 2012
  • Most of the roads are paved with impermeable materials such as asphalt concrete and cement concrete, and in the event of heavy rainfall, rainwater directly flows into river through a drainage hole on the pavement surface. This large quantity of rainwater directly spilled into the river frequently leads to the flooding of urban streams, damaging lowlands and the lower reaches of a river. In recent years there has been a great deal of ongoing research concerning water permeability and drainage in pavements. Accordingly, in this research, a porous polymer concrete was developed for permeable pavement by using unsaturated polyester resin as a binder, recycled aggregate as coarse aggregate, fly ash and blast furnace slag as filler, and its physical and mechanical properties were investigated. Also, 3 types of permeable polymer block by optimum mix design were developed and rainfall runoff reduction effects by permeability pavement using permeable polymer block were analyzed based on hydraulic experimental model. The infiltration volume, infiltration ratio, runoff initial time and runoff volume in permeability pavement with permeable polymer block of $300{\times}300{\times}80$ mm were evaluated for 50, 100 and 200mm/hr rainfall intensity.