• Title/Summary/Keyword: Permeable

Search Result 1,045, Processing Time 0.026 seconds

Strength Variation of Cemented Sand Due to Wetting (수침이 고결모래의 강도에 미치는 영향)

  • Park, Sung-Sik;Kim, Ki-Young;Kim, Chang-Woo;Choi, Hyun-Seok
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.29 no.6C
    • /
    • pp.303-311
    • /
    • 2009
  • In this study, weakly cemented sand was cured at air dry condition with different periods (3, 7, 14, 21, 28 days) and its unconfined compressive strength was evaluated. As a result, the strength of specimens with low cement ratios such as 4 and 8% increases until 7 days curing but, after 7 days, their strength continuously decreases. The strength of specimens with relatively high cement ratios such as 12 and 16% increases up to 7 days curing and then stays almost constant until 21 days. After 21 days curing, their strength suddenly dropped down, which is much lower than the strength of 3 days curing specimen. A cemented sand and gravel called CSG, which is highly permeable, could be exposed to repetitive drying and wetting conditions due to rainfall or groundwater table change during curing. In this study, the weakly cemented sand is exposed to repetitive drying and wetting and then its unconfined compressive strength was evaluated. As a result, the strength of a specimen with 27 days drying condition following 1 day wetting was at maximum 35% lower than the one cured under 28 days drying. The strength degradation due to wetting decreases as a cement ratio increases. However, the strength of a specimen with repetitive drying and wetting increases as the number of wetting increases until 3 cycles. After 3 cycles of drying and wetting, the rate of strength increase decreases due to an insufficient water for hydration or stays constant. If the sufficient water supply is provided to cemented sand during curing, the target or design strength increase can be achieved. Otherwise, the strength degradation due to wetting should be considered at the design stage.

The Phase Difference Effects on 3-D Structure of Wave Pressure Acting on a Composite Breakwater (혼성방파제에 작용하는 3차원 파압구조에 미치는 위상차의 영향)

  • Hur, Dong-Soo;Yeom, Gyeong-Seon;Bae, Ki-Seong
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.26 no.5B
    • /
    • pp.563-572
    • /
    • 2006
  • In designing the coastal structures, the accurate estimation of wave forces on them is very important. Recently, the empirical formulae such as Goda formula are widely used to estimate wave forces, as well as 2-D hydraulic and numerical model tests. But, sometimes, these estimation methods mentioned above seem to be unreasonable to predict 3-D structure of wave pressure on the coastal structures with 3-D plane arrangement in the real coastal area. Especially, in case of consideration of phase difference at harbor and seaward sides of the large-sized coastal structures like a composite breakwater, it is easily expected that the real wave pressures on each section of coastal structure have 3-D distribution. A new numerical model of 3-D Large Eddy Simulation, which is applicable to permeable structure, is developed to clarify the 3-D structure of wave pressures acting on coastal structure. The calculated wave forces on 3-D structure installed on the submerged breakwater show in good agreement with the measured values. In this study, the composite breakwater is adopted as a representative structure among the large-sized coastal structures and the 3-D structure of wave pressures on it is discussed in relation to the phase difference at harbor and seaward sides of it due to wave diffraction and transmitted wave through rubble mound.

The Experimental Study on Electrokinetic Injection Improvement of Low Permeable Ground (저 투수성 지반의 동전기 주입 개량의 실험 연구)

  • Kim, Soo-Sam;Han, Sang-Jae;Kim, Ki-Nyun
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.26 no.2C
    • /
    • pp.99-108
    • /
    • 2006
  • In this study a series of bench scale test are conducted to increase the undrained shear strength of clayey soils using by Electro-kinetic injection stabilization method. The sodium silicate was injected in anode reservoir and its concentration was changed with 500, 1000, 1500, 2000, 2500mM for configuration of applicability of Electro-kinetic injection stabilization method. Also, the treatment time and electric gradient was changed to acquire the optical influence factors. For increasing the shear strength to maximum values, the calcium chloride and aluminium hydroxide, which concentration was changed with 50, 250, 500, 750, 1000mM, were added at anode reservoir for 5 days after the treatment of sodium silicate in 5 days as the 2nd additives. The test of results in determination of sodium silicate concentration show that the undrained shear strength at each point had a tendency to converge into a constant value when the concentration of sodium silicate came to 1000mM and above. The maximum shear strength increasement was 800% compared with initial value. After a series of test, the electric gradient and treatment time for application of electric fielld were 1V/cm and 6 days. In case of 2nd additives test, the concentration for maximum shear strength is 250mM in all additives and the effects of shear strength improvement was developed approximately 20~30% in comparison to addition of single injection material.

Evaluation of the Characteristics of High-Flux Reverse Osmosis Membranes with Various Additives (다양한 첨가제에 따른 고투과성 역삼투막의 특성평가)

  • Hyun Woong Kwon;Kwang Seop Im;Gede Herry Arum Wijaya;Seong Min Han;Seong Heon Kim;Jun Ho Park;Dong Jun Lee;Sang Min Eom;Sang Yong Nam
    • Membrane Journal
    • /
    • v.33 no.6
    • /
    • pp.427-438
    • /
    • 2023
  • In this study, in order to improve the performance of the reverse osmosis membrane with high water flux and high salt rejection, a study was conducted on the evaluation of characteristics according to the curing temperature and time during various additives and interfacial polymerization. The morphology of the membrane with no additives and the membrane with additives both showed a "rigid-and-valley" structure, confirming that the polyamide layer was successfully polymerized on the surface of the porous support layer. In addition, the additive of 2-Ethyl-1,3-hexanediol (EHD) had improved hydrophilicity and water flux, which was confirmed by measuring the contact angle. Finally, a highly permeable TFC membrane with NaCl and MgSO4 salt rejection of 97.78% and 98.7% and a high water flux of 3.31 L/(m2⋅h⋅bar) was prepared.

Analysis of the Relationship between Urban Permeable/Impermeable Surfaces and Urban Tree Growth Using GeoXAI (GeoXAI를 활용한 도시 투수/불투수면과 도시수목 생육 관계 분석)

  • Seok Jun Kong;Joon Woo Lee;Geun Han Kim
    • Korean Journal of Remote Sensing
    • /
    • v.39 no.6_1
    • /
    • pp.1437-1449
    • /
    • 2023
  • The purpose of this study is to analyze whether pervious and impervious areas in urban areas affect tree growth. In order to determine the differences in the growth of six species of trees planted simultaneously, the effects of pervious and impervious surfaces on tree growth were analyzed using the Normalized Difference Vegetation Index (NDVI) produced using Sentinel-2 and sub-divided land cover map from the Ministry of Environment. For this purpose, the Geospatial eXplainable Artificial Intelligence(GeoXAI) concept was applied. As a result of the analysis, the explanatory power of the model was found to be the best when considering the area of land cover included in the 10m range for Pinus densiflora, the 20 m range for Zelkova Serrata, Metasequoia glyptostroboides, and Ginkgo biloba, the 30 m range for Platanus occidentalis, and the 40 m range for Yoshino cherry trees. In addition, the wider the pervious area, the more active the growth of trees,showing a positive correlation, and the wider the impervious area, such as nearby artificial ground, showed a negative correlation with tree growth. This shows that surrounding pervious and impervious areas affect the growth of trees and that the scope of influence varies depending on the tree species.

Biogeochemical Organic Carbon Cycles in the Intertidal Sandy Sediment of Nakdong Estuary (낙동강 하구 갯벌 사질 퇴적물에서 생지화학적 유기탄소순환)

  • Lee, Jae-Seong;Park, Mi-Ok;An, Soon-Mo;Kim, Seong-Gil;Kim, Seong-Soo;Jung, Rae-Hong;Park, Jong-Soo;Jin, Hyun-Gook
    • The Sea:JOURNAL OF THE KOREAN SOCIETY OF OCEANOGRAPHY
    • /
    • v.12 no.4
    • /
    • pp.349-358
    • /
    • 2007
  • In order to understand biogeochemical cycles of organic carbon in the permeable intertidal sandy sediments of the Nakdong estuary, we estimated the organic carbon production and consumption rates both in situ and in the laboratory. The Chl-a content of the sediment and the nutrient concentrations in below surface pore water in the sandy sediment were lower than in the muddy sediment. The sediment oxygen consumption rates were relatively high, especially when compared with rates reported from other coastal muddy sediments with higher organic carbon contents. This implied that both the organic carbon degradation and material transport in the sandy sediment were enhanced by advection-related process. The simple mass balance estimation of organic carbon fluxes showed that the major sources of carbon in the sediment would originate from benthic microalgae and detrital organic carbon derived from salt marsh. The daily natural biocatalzed filtration, extrapolated from filtration rates and the total area of the Nakdong estuary, was one order higher than the maximum capability of sewage plants in Busan metropolitan city. This implies that the sandy sediment contributes greatly to biogeochemical purification in the area, and is important for the re-distribution of materials in the coastal environment.

Evaluation of Hydrogeological Characteristics of Deep-Depth Rock Aquifer in Volcanic Rock Area (화산암 지역 고심도 암반대수층 수리지질특성 평가)

  • Hangbok Lee;Chan Park;Junhyung Choi;Dae-Sung Cheon;Eui-Seob Park
    • Tunnel and Underground Space
    • /
    • v.34 no.3
    • /
    • pp.231-247
    • /
    • 2024
  • In the field of high-level radioactive waste disposal targeting deep rock environments, hydraulic characteristic information serves as the most important key factor in selecting relevant disposal sites, detailed design of disposal facilities, derivation of optimal construction plans, and safety evaluation during operation. Since various rock types are mixed and distributed in a small area in Korea, it is important to conduct preliminary work to analyze the hydrogeological characteristics of rock aquifers for various rock types and compile the resulting data into a database. In this paper, we obtained hydraulic conductivity data, which is the most representative field hydraulic characteristic of a high-depth volcanic bedrock aquifer, and also analyzed and evaluated the field data. To acquire field data, we used a high-performance hydraulic testing system developed in-house and applied standardized test methods and investigation procedures. In the process of hydraulic characteristic data analysis, hydraulic conductivity values were obtained for each depth, and the pattern of groundwater flow through permeable rock joints located in the test section was also evaluated. It is expected that the series of data acquisition methods, procedures, and analysis results proposed in this report can be used to build a database of hydraulic characteristics data for high-depth rock aquifers in Korea. In addition, it is expected that it will play a role in improving technical know-how to be applied to research on hydraulic characteristic according to various bedrock types in the future.

Determination Method of Suitable Mud Density While Drilling through Confined Aquifer and Its Application (피압대수층을 통과하는 대심도 시추 중 적정이수밀도 결정 방법 및 적용 사례)

  • Woon Sang Yoon;Yoosung Kim;Hyeongjin Jeon;Yoonho Song;Changhyun Lee
    • The Journal of Engineering Geology
    • /
    • v.34 no.2
    • /
    • pp.217-228
    • /
    • 2024
  • During deep drilling, confined aquifers can present various challenges such as the inability to remove cuttings, rapid groundwater influx, and mud loss. Particularly in flowing well conditions, it is essential to apply the suitable mud density since the aquifer can generates an overpressurized condition. This paper proposes a method for determining the suitable mud density while drilling (SMD) through confined aquifers using mud window analysis and applies it to a case study. The minimum mud density at each depth, which represents the lower limit of the mud window, is determined by the equivalent mud density pore pressure gradient (or by adding a trip margin) at that depth. The pore pressure gradient of a confined aquifer can be calculated using the piezometric level or well head pressure of the aquifer. As the borehole reaches the confined aquifer, there is a significant increase in pore pressure gradient, which gradually decreases with increasing depth. The SMD to prevent a kick can be determined as the maximum value among the minimum mud densities in the open hole section. After entering the confined aquifer, SMD is maintained as the minimum mud density at the top of the aquifer during the drilling of the open hole section. Additionally, appropriate casing installation can reduce the SMD, minimizing the risk of mud loss or invasion into the highly permeable aquifer.

Study of Polysulfone Membrane for Membrane-covered Oxygen Probe System (산소 전극 시스템에 사용되는 polysulfone막에 대한 연구)

  • Hong, Suk In;Kim, Hyun Joon;Park, Hee Young;Kim, Tae Jin;Jeong, Yong Seob
    • Applied Chemistry for Engineering
    • /
    • v.7 no.5
    • /
    • pp.877-887
    • /
    • 1996
  • The ideal membranes for membrane-covered oxygen probes system should be selectively permeable for oxygen and chemically inert, and have good mechanical strength. Polysulfone(PSf) was selected to develop the membrane for membrane-covered oxygen electrodes system. PSf membranes have properties such as good reproducibility, good mechanical strength, chemical inertness, and high heat resistance. PSf membranes were cast from polymer solution on the glass plate at constant temperature, and casting solvents used were tetrahydrofuran(THF), methylene chloride, and N-methyl-2-pyrrolidone(NMP). Tricresyl phosphate(TCP) as plasicizer was added to PSf to increase the softness of membrane. The permeation characteristics were observed for pure oxygen and nitrogen through pure PSf membranes by variable volume method and membrane-covered electrode system. The permeability coefficients of oxygen and nitrogen measured by variable volume method were slightly decreased with increasing of upstream pressure. The permeation properties of PSf membrane using methylene choride as casting solvent were not affected by the PSf amount of polymer solution. The permeability coefficients of oxygen and nitrogen for PSf membrane containing TCP were very slightly lower than those for pure PSf membrane, but ideal separation factors were slightly higher. The flexibility of PSf membrane containing 2wt% TCP was better than that of pure PSf membrane. It was expected that this increase in flexibility would solve the difficulty of fixing the membrane to the cathode. The membrane-covered oxygen probes system was composed of anode, cathode and electrolyte. The type of the anode was Ag/AgCl half-cell, that of cathode was Ag, and the electrolyte was 4N KCl solution. The result of sampled current voltametry for PSf membrane showed the plateu region at -0.3V~-1.0V. The correlation coefficient of oxygen partial pressure versus current for PSf membrane was relatively high, 0.99949. It was concluded that PSf membrane was the good candidate for the membrane-covered oxygen probes system.

  • PDF

Effects of Active Modified Atmosphere Packaging on the Storability of Fresh-cut Paprika (Active MAP가 파프리카 신선편이 저장성에 미치는 영향)

  • Choi, In-Lee;Yoo, Tae-Jong;Jung, Hyun-Jin;Kim, Il-Seop;Kang, Ho-Min;Lee, Yong-Beom
    • Journal of Bio-Environment Control
    • /
    • v.20 no.3
    • /
    • pp.227-232
    • /
    • 2011
  • The processing techniques are need to use the non-marketable paprika fruit because paprika that is difficult crop for cultivation and produced easily non-marketable fruits, such as physiological disorder fruit, malformed fruit, and small size fruit. This study was carried out to investigate the proper active modified atmosphere packaging (MAP) condition for enhancing the storability of fresh-cut paprika fruit. The fresh-cut paprika (cv 'Score', seminis) put into $7cm{\times}0.7cm$ size and packed them in 20 g bags. The active MAP and vacuum treated paprika fruits were packaged with LLDPE/Nylon, EVOH, Tie film, and injected partial pressures of $CO_2$ and $O_2$, and $N_2$ in the packages immediately after sealing to treat active MAP. The ratio of $CO_2$, $O_2$, and $N_2$ of active MAP conditions were 0 : 20 : 80 (air), 5 : 5 : 90, 30 : 10 : 60, 10 : 70 : 20 and vacuum treatment did not contain any gas. The passive packaging treated paprika packaged with $40{\mu}m$ ceramic film. After 7 days of storage at $9^{\circ}C$, the fresh weight decreased less than 2% in all treatments, and showed lower in 5 : 5 : 90 ($CO_2:O_2:N_2$) active-MAP treatment and higher in vacuum treatment than other treatments. The $CO_2$ and $O_2$ concentration in packages did not change remarkably in active-MA treatments except 30 : 10 : 60 active-MAP treatment that showed sharply decreased $O_2$, concentration and increased $CO_2$ concentration at $1^{st}$ day of storage at $9^{\circ}C$. The ethylene concentration in package was the highest in 30 : 10 : 60 active-MAP treatment and the lowest in the passive MAP treatment that packaged with gas permeable film during $9^{\circ}C$ storage for 7 days. The 30 : 10 : 60 active-MAP treatments were not proper condition to storage fresh-cut paprika. The visual quality was maintained higher in 0 : 20 : 80 (air), 5 : 5 : 90, and 10 : 70 : 20 active MAP treatments and passive MAP treatment than others and the firmness, off-odor, and electrolyte leakage was investigated at 7th day of storage at $9^{\circ}C$. The 5 : 5 : 90 and 10 : 70 : 20 active-MAP treatment showed higher firmness and lower off-odor than other treatments after $7^{th}$ day of storage at $9^{\circ}C$. In addition, the electrolyte leakage was reduced less than 20% at 0 : 20 : 80 (air), 5 : 5 : 90, 10 : 70 : 20, and passive MA treatments. Therefore, 10 : 70 : 20 ($CO_2:O_2:N_2$) and 0 : 20 : 80 (air) might be recommended for proper active MAP conditions.