Journal of the Korean Association of Oral and Maxillofacial Surgeons
/
제37권5호
/
pp.343-348
/
2011
Introduction: Third molar extraction is one of the most common procedures in oral and maxillofacial surgery. The impacted third molar causes many pathological conditions, such as pericoronitis, caries, periodontitis, resorption of adjacent teeth, and cyst or tumors associated with impacted teeth. Extraction is often considered the treatment of choice for impacted lower third molars. On the other hand, imprudent extraction of deeply impacted third molars can cause permanent complications, such as inferior alveolar nerve damage. Therefore, guidelines for the extraction of lower third molars should be set to prevent embarrassing complications. This study examined the indication and current trends of the extracted lower third molars in the dental hospital of a dental college. Materials and Methods: 557 extracted third molars were evaluated at the department of oral and maxillofacial surgery of Yonsei University. The chief complaint, diagnosis, age and degree of impaction were analyzed to determine the tendency for the extraction of asymptomatic lower third molars. Results: The percentage of asymptomatic third molars was 40.8%. In cases of full impacted tooth or full erupted tooth, the percentage of asymptomatic teeth was more than 50% (52.4% and 54.3, respectively). Among those partially impacted teeth, 73.1% of them showed symptoms, such as pain, tenderness and swelling. In terms of age, pericoronitis was evident at a younger age, and dental caries/periodontitis was the main cause of removal in those aged over 50. Twenty nine cases (1.6%) had teeth associated with pathological changes Conclusion: The incidence of pathological changes to the lower third molar was relatively low. Surgical extraction is recommended in cases of partially impacted teeth. In Korea, the incidence of asymptomatic third molar extraction was relatively higher than in European countries. More careful attention would be desirable to consider the risks and benefits of lower third molar extraction.
Jung Min Woo;Hwang Chang Mo;Jeong Gi Seok;Kang Jung Soo;Ahn Chi Bum;Kim Kyung Hyun;Lee Jung Joo;Park Yong Doo;Sun Kyung
대한의용생체공학회:의공학회지
/
제26권6호
/
pp.393-398
/
2005
An electromechanical type is the most useful mechanism in the various pumping mechanisms. It, however, requires a movement converting system including a ball screw, a helical cam, or a solenoid-beam spring, which makes the device complex and may lessen reliability. Thus, the authors have hypothesized that an electromagnetic actuator mechanism can eliminate the movement converting system and that thereby enhance the mechanical reliability and operative simplicity of an electropneumatic pump. The purpose of this study was to show a novel application of electromagnetic actuator mechanism in pulsatile pump and to provide preliminary data for further evaluations. The electromagnetic actuator consists of stators with a single winding excitation coil and movers with a high energy density neodymium-iron-boron permanent magnet. A 0.5mm diameter wire was used for the excitation coil, and 1000 turns were wound onto the stators core with parallel. A prototype of extracorporeal electro-pneumatic pump was constructed, and the pump performance tests were performed using a mock system to evaluate the efficiency of the electromagnetic actuator mechanism. When forward and backward electric currents were supplied to the excitation coil, the mover effectively moved back and forth. The nominal stroke length of the actuator was 10mm. The actuator dimension was 120mm in diameter and 65mm in height with a mass of 1.4kg. The prototype pump unit was 150mm in diameter, 150mm in thickness and 4.5kg in weight. The maximum force output was 70N at input current of 4.5A and the maximum pump rate was 150 beats per minute. The maximum output was 2.0 L/minute at a rate of 80bpm when the afterload was 100mmHg. The electromagnetic actuator mechanism was successfully applied to construct the prototype of extracorporeal electropneumatic pump. The authors provide the above results as a preliminary data for further studies.
우리나라의 기록물관리제도는 20년이라는 짧은 역사에도 불구하고 비교적 안정적으로 정착되고 있다. 그러나 이러한 성장은 주로 '공공'의 영역에서 이루진 것으로 '민간' 영역으로의 발전은 다소 미진하였다. 다행히도 최근에 지방영구기록물관리기관 두 곳이 개원하게 되면서 그간 지지부진했던 지방기록물관리에 대한 관심이 증대되고 있다. 더불어 지방기록물의 한 축으로써 지역의 정체성과 다양성을 포함하는 민간기록물의 수집 및 관리에도 이목이 집중되고 있다. 지방기록물관리기관의 민간기록물 수집은 지방자치단체에서 정하는 조례에 따라야 한다. 이에 본 연구는 민간기록물의 수집 및 관리의 법제 근거가 되는 조례를 분석하고자 한다. 분석의 대상은 현재 우리나라에 제정된 민간기록물관리 관련 조례를 분석의 대상으로 정한다. 연구의 진행은 민간기록물관리에 관한 조례의 제정 현황, 조례의 제정 배경, 조례의 내용을 분석하였다. 본 연구의 결과는 실질적으로 우리나라 민간기록물의 수집과 관리를 위한 조례가 대상이라는 점에서 향후 민간기록물관리 관련 조례의 제정 시 참고할 만한 기반 연구로 활용될 수 있다.
영구정지 후 해체가 계획된 고리 1호기 원자력발전소는 해체 과정에서 다양한 종류의 방사성폐기물이 대량으로 발생할 것으로 예상되고 있다. 이 중 가장 많은 발생량을 차지할 것으로 예상되는 콘크리트 방사성폐기물에 대하여 기존 폐기물의 처분 현황 및 법적 제한사항등을 분석하여 적절하고 효율적인 처분방법을 마련하는 것은 중요한 사안일 것으로 판단된다. 콘크리트 방사성폐기물은 다양한 준위의 폐기물들이며, 이 중 규제해제 준위에 해당되어 자체처분이 가능한 폐기물은 바이오실드 콘크리트이다. 본 논문에서는 방사화 평가 결과를 바탕으로 자체처분이 가능한 폐기물을 자체처분 평가 코드인 RESRAD 코드 프로그램을 이용하여 자체처분 안전성 평가를 수행하였다. 대상 폐기물의 자체처분 시나리오를 선정하고 자체처분시 개인별 피폭선량을 계산하여 국내 원자력안전법에서 규정하는 자체처분 기준 제한치의 만족 여부를 판단하였다. 평가 결과, 전체적으로 상당히 낮은 결과 값을 보이며 기준 제한치를 만족하는 결과를 나타내었다. 이러한 자체처분 안전성 평가 결과를 바탕으로 규제해제 대상으로서 자체처분 가능한 바이오실드 콘크리트 폐기물에 대한 적절한 처분방법을 제시하였다.
국내 작은도서관이 가장 많이 소재하고 있는 경기도에는 공동주택단지 내 작은도서관의 비율이 42%에 이르고 있으나, 법적 의무에 의해 설립된 도서관들이 자발적 의지에 의존하여 관리·운영됨에 따라 휴관·폐관되는 사례가 지속적으로 발생하고 있다. 공동주택단지 내 작은도서관의 활성화를 위해서는 단지 내 마을 공동체의 구심점 역할을 통해 활성화의 방안을 모색하는 것이 타당하다. 이를 위해 본 연구에서는 경기도 작은도서관의 현황 조사, 경기도 및 31개 시군의 공동주택단지 내 작은도서관 운영자 및 관계자 대상의 설문조사와 심층인터뷰를 실시하였으며, 이를 기반으로 공동주택단지내 작은도서관 운영의 실제적인 활성화 방안을 도출하고자 하였다. 작은도서관에 대한 공동체 인식 개선, 자체 운영 능력 배양, 법·제도 개선, 지자체의 지원 강화의 4가지 목표를 설정하여 실천방안을 도출하였다. 사회의 변화에 따른 경기도 공동주택단지 내 작은도서관 뿐 아니라 타 사립작은도서관의 지속적인 발전을 위한 연구도 수행될 필요가 있다.
NiFe/Cu/NiFe/IrMn 스핀밸브 박막소자에 대해 자화 용이축에 의존하는 형상 자기이방성을 조사하였다. Ta(5 nm)/NiFe(8 nm)/Cu(2.3 nm)/NiFe(4 nm)/IrMn(8 nm)/Ta(2.5 nm) 다층박막을 증착할 때 350 Oe의 자기장으로 인가한 자화 용이축을 폭 방향 또는 길이 방향으로 설정하여 $1\;{\mu}m\;{\times}\;18\;{\mu}m$의 소자를 제작하였다. 2단자 방법으로 소자의 자기저항 곡선으로부터 자장감응도를 측정하고 자화 용이축에 따른 형상 자기이방성을 비교하였다. 측정한 소자 길이 방향의 센싱전류와 고정층의 자화 용이축이 소자 폭방향 각도가 GMR-SV 소자를 바이오센서로 활용하는데 중요한 요인임을 확인하였다.
지방분권의 흐름에 맞춰 새 시대의 기록관리를 위해 기록 분권을 통한 기록관리 현장에서부터의 내재적 발전을 준비해야 할 시점이다. 중앙집중화되고 있는 기록관리체제를 극복하기 위해서는 더 많은 아카이브가 설립되어 자율적이고 분권적인 기록관리를 실현해야 한다. 본격적인 전자기록관리 환경으로의 변화에 따라 물리적인 이관을 전제로 한 처리과-기록관-영구기록물관리기관의 3단계 체제는 이관비용 및 업무효율 측면에서 그 적절성과 효율성이 재검토되어야 한다. 이에 따라 기록관은 기관 단위의 연속체적 기록관리 수행과 자율적인 기록관리업무 수행을 위해 기관 아카이브로의 기능을 수행해야 한다. 본 연구는 기록관리의 분권화와 정보거버넌스 지향의 차원에서 기록관이 기관의 아카이브로써 기능을 확장하도록 하는 가능성과 시사점을 몇 가지 사례를 통해 살펴보았다. 또 이를 수행하기 위한 방법으로 기록관리기관 유형을 다각화하고 현용-준현용-비현용 기록관리를 통합적으로 수행하는 기록관의 기능이 어떻게 설계되어야 하는지 도출하였다. 각급 기관은 기관의 상황과 여건에 맞게 기록관을 설립하고 각 기록관 차원에서 정보거버넌스를 지향해야 하며 각급 기록관은 수평적인 네트워크를 구축하여 기록정보관리의 거버넌스를 수행하도록 해야 한다.
Large single grain $Gd_{1.5}Ba_2Cu_3O_{7-y}$ (Gd1.5) bulk superconductors were fabricated by a top-seeded melt growth (TSMG) process using an $NdBa_2Cu_3O_{7-y}$ seed. The seeded Gd1.5 powder compacts with a diameter of 50 mm were subjected to the heating cycles of a TSMG process. After the TSMG process, the diameter of the single grain Gd1.5 compact was reduced to 43 mm owing to the volume contraction during the heat treatment. The superconducting transition temperature ($T_c$) of the top surface of the single grain Gd1.5 sample was as high as 93.5 K. The critical current densities ($J_cs$) at 77 K and 1T and 1.5 T were in ranges of 25,200-43,900 $A/cm^2$ and 10,000-23,000 $A/cm^2$, respectively. The maximum attractive force at 77 K of the sample field-cooled using an Nd-B-Fe permanent magnet (surface magnetic field of 0. 527 T) was 108.3 N; the maximum repulsive force of the zero field-cooled sample was 262 N. The magnetic flux density of the sample field-cooled at 77 K was 0.311T, which is approximately 85% of the applied magnetic field of 0.375 T. Microstructure investigation showed that many $Gd_2BaCuO_5$ (Gd211) particles of a few ${\mu}m$ in size, which are flux pinning sites of Gd123, were trapped within the $GdBa_2Cu_3O_{7-y}$ (Gd123) grain; unreacted $Ba_3Cu_5O_8$ liquid and Gd211 particles were present near the edge regions of the single grain Gd1.5 bulk compact.
지난 5년간 NdFeB계 이방성 본드자석은 25 MGOe의 높은 자기특성을 강점으로 기존 페라이트 영구자석을 갈음하면서 모터의 경량화라는 새로운 패러다임을 주도했고 자동차용과 전동공구용 모터산업분야에서 두드러진 약진을 보였다. 또한 차체중량감소를 통한 연비향상이라는 자동차산업의 기술동향에 정확히 초점을 두고 기존모터의 50 % 경량화라는 새로운 변혁을 이끌어 냈다. 그러나 2010년 7월에 중국이 희토류원소의 수출규제를 발표함에 따라 2011년 희토류 원자재는 또 한 차례의 폭등을 기록하였고 그 여파는 전방 수요산업에 심각한 충격으로 던져지고 있다. 각 희토류 주요 소비국들은 자원 확보, 희토류 최소사용부품개발 및 희토류 대체 신기술개발 강화에 총력을 다하는 모습이다. 이러한 환경적 변화가 이방성 본드자석 분야에는 중희토류 원소인 Dy의 사용량을 줄이면서 보자력을 향상시키고자하는 기술적 도전을 유발하였고 모터고속화 응용분야에 탐색을 시도하게 하였다. 본 글에서는 희토류 자원문제에 대한 각국 희토류자석산업의 대응과 NdFeB 이방성 본드자석으로 대표되는 Aichi Steel사의 MAGFINE 자성분말에 대해 최근의 개발 동향 및 응용분야에 대해 소개하고자 한다.
본 논문은 핵자기 공명신호를 검출하기 위하여 자석상자 내에 한 개의 코일을 가진 펄스방식의 핵자기 공명장치에 대한 새로운 구현방법에 관한 것이다. 수소 원자핵의 Larmor 주파수가 5MHz가 되도록 설계된 자석상자에 5MHz 고주파 자기장을 인가하여 자석상자 내에 투입된 글리세린 시료로부터 수소 원자핵의 공명신호를 얻었다. 자석상자 내의 정자기장은 자기장의 세기가 1168 gauss인 영구자석을 사용하여 만들었으며, 고주파 자기장은 5MHz의 주파수를 가지며 전류의 크기가 8A인 고주파 신호를 5.73μH의 코일에 인가하여 발생시켰다. 고주파 자기장의 발생시간을 2.8μsec로 하였을 때 핵자기 공명신호는 최대 크기로 나타났으며, 반복 검출을 하기 위하여 고주파 자기장의 발생주기를 100msec로 설계하였다. 시료에서 발산되어 자석상자 내의 코일에 감지되는 핵자기 공명신호는 Larmor 주파수와 같은 주파수를 가지는 신호가 진폭변조된 형태로 나타났다. 코일에 감지된 신호를 송수신 분리회로와 전치증폭기 및 중간증폭기에서 각각 20.7dB, 36dB 및 40dB로 증폭하고 동기검파회로에서 검파하여 핵자기 공명신호를 얻었다.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.