• Title/Summary/Keyword: Periodic Monitoring

Search Result 255, Processing Time 0.024 seconds

Serial Survey on Group A beta-Hemolytic Streptococcal Carrier Rate and Serotyping in Elementary School Children in 1996~1998 (3년간(1996~1998) 초등학생의 A군 연쇄구균 보균율과 혈청학적 분류에 관한 연구)

  • Kim, Ji-Hyun;Kim, Ju-Ye;Kang, Hyeon-Ho;Cha, Sung-Ho;Lee, Young-Hee
    • Pediatric Infection and Vaccine
    • /
    • v.7 no.1
    • /
    • pp.143-151
    • /
    • 2000
  • Purpose : The accuracy of bacteriologic diagnosis of beta-hemolytic streptococcal pharyngotonsillitis depends on the degree of carrier rate in that area where the throat swabs are obtained and the evaluation of serological T typing as an epidemiologic marker is important to understand epidemiology of streptococcal infection. The purpose of this study is to know the carrier rates of group A streptococcus in normal children form four different areas and to find out the epidemiologic characteristic in distribution of the serotypes for 3 years. Method : Throat swabs were obtained from the tonsillar fossa of normal school children in four different areas(Uljin, Seoul, Osan, Kunsan) from March to May 1996, in Uljin in April 1997, and in Uljin in April 1998. The samples were plated on a 5% sheep blood agar plate and incubated overnight at $37^{\circ}C$ before examination for the presence of beta-hemolytic colonies. All isolated beta-hemolytic streptococcus were grouped and serotyped by T agglutination. Results : The carrier rate of beta-hemolytic streptococci and group A streptococci in 1996 were 27.6%, 18.6% at Uljin; 16.4%, 2.7% at Seoul; 33.0%, 26.0% at Osan; 20.0%, 12.3% at Kunsan, respectively. Among 1,192 normal school children from 4 different areas, we obtained 179 strains of group A streptococci. Fifty two percent of the strains were typable by T agglutination in 1996. Common T-type in 1996 were NT, T1, T3, T2 at Uljin; T12, T25 at Seoul; NT, T6, T28 at Osan; T25, T4, NT, T5 at Kunsan, in decreasing order, respectively. At Uljin, T1, T3, T25 accounted for 69% of strains in 1996, T1, T12, T25 accounted for 70% in 1997, and T12, T4 accounted for 88% in 1998. Conclusion : Higher carrier rates were found in Uljin and Osan, where there are a lower population density with scanty of medical facilities compared with another areas. We supposed that low carrier rates is likely to be related to antibiotic abuse or some epidemiologic factor. The periodic and seasonal serotyping analysis is important in monitoring and understanding the epidemiologic patterns of group A streptococci.

  • PDF

Microbiological Safety Assessment to Secure Safety of Food Service in University (대학 내 급식소의 안전성 확보를 위한 미생물학적 안전성 평가)

  • Kim, Kyeong-Yeol;Nam, Min-Ji;Nam, Bo-Ram;Ryu, Hee-Jung;Heo, Rok-Won;Shim, Won-Bo;Chung, Duck-Hwa
    • Journal of Food Hygiene and Safety
    • /
    • v.25 no.1
    • /
    • pp.49-58
    • /
    • 2010
  • The objectives of this study were to investigate the microbial contamination levels on food service in university and to provide the information of microbial contamination to improve food safety. A total of 288 samples were collected during summer and winter season between 2006 and 2008 from 4 food services located in the university in Western Gyeongnam and were used to detect sanitary indicator bacteria [aerobic plate count (APC), coliform, and Escherichia coli] and pathogenic bacteria (Staphylococcus aureus, Salmonella spp.). As a result, APC and coliform for hand and kitchen utensils which are used often by the employee were detected at high levels of 1.1~5.5 and 1.3~5.3 log CFU/($100\;cm^2$, hand), respectively. The contamination levels of APC and coliform in cooked foods and drinking water were 0.8~6.4 and 1.3~5.0 log CFU/(g, mL), respectively. Especially, the cooked foods showed the highest contamination for APC (2.1~6.4 log CFU/g) and coliform (1.0~5.0 log CFU/g). We think the reason that the cooked foods may be contaminated with APC and coliform on cooking process by using employee's hand and kitchen utensils. Moreover, S. aureus for hand and kitchen utensils was detected at levels of 2.8~3.0 and 2.0~2.3 log CFU/(g, hand), but Salmonella spp. was not detected. According to the above results, contamination levels of the samples were mostly decreased irrespective of summer and winter season. The results obtained indicated that it is necessary to periodic monitoring for microorganism contamination and education about personal and environmental hygiene to employee for ensuring food safety of food service in university.

Periodic Growth Monitoring and Final Age at Maturity in a Robinia pseudoacacia Stand (아까시나무 임분의 시계열적 생장 모니터링 및 벌기령 도출)

  • Jaeyeop, Kim;Sora, Kim;Jeongeun, Song;Sangmin, Sung;Jongsoo, Yim;Yeongmo, Son
    • Journal of Korean Society of Forest Science
    • /
    • v.111 no.4
    • /
    • pp.613-621
    • /
    • 2022
  • The study aim was to investigate changes in the diameter, number of standing trees, stand volume per ha and site index by the forest survey order, climate zone (northern temperate, central temperate, southern temperate, and warm temperate regions), and altitude in 100 m intervals) by collecting samples of Robinia pseudoacacia from the fifth, sixth, and seventh national forest survey datasets. The rotation cutting age, which is a standard used for wood, was calculated. The changes were statistically analyzed by performing ANOVA and the Duncan multiple test. Diameter growth naturally increased according to the forest survey order and was lowest in the southern temperate region by climate zone and lowest at the 301-400 m altitude. The number of standing trees per ha did not change according to the forest survey order and altitude, and the density was highest in the central temperate region and lowest in the southern temperate region. The stand volume per ha increased according to the forest survey order, and the climate zone was divided into two groups: ① northern temperate region and central temperate region, ② southern temperate region and warm temperate region. The stand volume growth was highest at the 201-300 m point. Thesite index showed results similar to the change pattern of the stand volume per ha. The growth curve, which can be seen by the change in stand volume per ha, was estimated by applying theWeibull formula, and the stand volume per ha was estimated to reach approximately 200 m3/ha at 50-60 years. The rotation of the highest production in volume, which is the standard for using trees as wood rather than honey sources, was calculated to be 34 years.

Priority Analysis of Cause Factors of Safety Valve Failure Mode Using Analytical Hierarchy Process (AHP를 활용한 안전밸브(PSV) 고장모드의 Cause Factors 우선순위 분석)

  • Kim, Myung Chul;Lee, Mi Jeong;Lee, Dong Geon;Baek, Jong-Bae
    • Korean Chemical Engineering Research
    • /
    • v.60 no.3
    • /
    • pp.347-355
    • /
    • 2022
  • The safety valve (PSV) is a safety device that automatically releases a spring when the pressure generated by various causes reaches the set pressure, and is restored to a normal state when the pressure falls below a certain level. Periodic inspection and monitoring of safety valves are essential so that they can operate normally in abnormal conditions such as pressure rise. However, as the current safety inspection is performed only at a set period, it is difficult to ensure the safety of normal operation. Therefore, evaluation items were developed by finding failure modes and causative factors of safety valves required for safety management. In addition, it is intended to provide decision-making information for securing safety by deriving the priority of items. To this end, a Delphi survey was conducted three times to derive evaluation factors that were judged to be important in relation to the Failure Mode Cause Factor (FMCFs) of the safety valve (PSV) targeting 15 experts. As a result, 6 failure modes of the safety valve and 22 evaluation factors of its sub-factors were selected. In order to analyze the priorities of the evaluation factors selected in this way, the hierarchical structure was schematized, and the hierarchical decision-making method (AHP) was applied to the priority calculation. As a result of the analysis, the failure mode priorities of FMCFs were 'Leakage' (0.226), 'Fail to open' (0.201), 'Fail to relieve req'd capacity' (0.152), 'Open above set pressure' (0.149), 'Spuriously' 'open' (0.146) and 'Stuck open' (0.127) were confirmed in the order. The lower priority of FMCFs is 'PSV component rupture' (0.109), 'Fail to PSV size calculation' (0.068), 'PSV Spring aging' (0.065), 'Erratic opening' (0.059), 'Damage caused by improper installation and handling' (0.058), 'Fail to spring' (0.053), etc. were checked in the order. It is expected that through efficient management of FMCFs that have been prioritized, it will be possible to identify vulnerabilities of safety valves and contribute to improving safety.

Gap-Filling of Sentinel-2 NDVI Using Sentinel-1 Radar Vegetation Indices and AutoML (Sentinel-1 레이더 식생지수와 AutoML을 이용한 Sentinel-2 NDVI 결측화소 복원)

  • Youjeong Youn;Jonggu Kang;Seoyeon Kim;Yemin Jeong;Soyeon Choi;Yungyo Im;Youngmin Seo;Myoungsoo Won;Junghwa Chun;Kyungmin Kim;Keunchang Jang;Joongbin Lim;Yangwon Lee
    • Korean Journal of Remote Sensing
    • /
    • v.39 no.6_1
    • /
    • pp.1341-1352
    • /
    • 2023
  • The normalized difference vegetation index (NDVI) derived from satellite images is a crucial tool to monitor forests and agriculture for broad areas because the periodic acquisition of the data is ensured. However, optical sensor-based vegetation indices(VI) are not accessible in some areas covered by clouds. This paper presented a synthetic aperture radar (SAR) based approach to retrieval of the optical sensor-based NDVI using machine learning. SAR system can observe the land surface day and night in all weather conditions. Radar vegetation indices (RVI) from the Sentinel-1 vertical-vertical (VV) and vertical-horizontal (VH) polarizations, surface elevation, and air temperature are used as the input features for an automated machine learning (AutoML) model to conduct the gap-filling of the Sentinel-2 NDVI. The mean bias error (MAE) was 7.214E-05, and the correlation coefficient (CC) was 0.878, demonstrating the feasibility of the proposed method. This approach can be applied to gap-free nationwide NDVI construction using Sentinel-1 and Sentinel-2 images for environmental monitoring and resource management.