• Title/Summary/Keyword: Period of Durability

Search Result 252, Processing Time 0.028 seconds

Phased Array Ultrasonic Application for Defects Estimation of FRP Box Member (FRP 박스부재의 결함평가를 위한 위상배열초음파 적용성 평가)

  • Kwak, Kae-Hwan;Yang, Dong-Woon;Kim, Ho-Sun;Lee, Ho-Hyun;Yun, Kuk-Hyun
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.52 no.5
    • /
    • pp.69-76
    • /
    • 2010
  • The structural material with the highest possibility of new materials that will be used in the future construction field is fiber reinforced polymer. The current studies on FRP members by using such excellent material characteristics mostly focused on stability, composite problem, and durability of FRP members. The initially constructed FRP members secure excellent stability and durability compared to reinforced concrete and steel materials, but measures for defections during the periodical inspection, methods for detecting breakages, and maintenance and reinforcement are not insufficient. Accordingly, this study proposed a measurement system using the FRP sensor to evaluate the safety of the FRP modular box member, and applied the phased array ultrasonic technique to detect the defects and damage likely to occur during the performance period.

A Study on the Improvement Plans of Maintenance Monitoring in Tunnel Structure (터널구조물 유지관리계측의 개선방안 연구)

  • Woo, Jong-Tae
    • Journal of the Society of Disaster Information
    • /
    • v.16 no.1
    • /
    • pp.10-20
    • /
    • 2020
  • Purpose: Analyze the results of on-site inspection of the tunnel structure maintenance management monitoring and suggest improvement plans. Method: We investigate and analyze the problems of various items on maintenance monitoring of tunnel structure of 14 subway lines of Seoul subway in downtown area. Result: The maintenance monitoring items, measurement quantity and installation location are classified into open tunnel and excavation tunnel and improvement plans are suggested respectively. Various durability criteria of the measuring instruments were examined, and durability confirmation method suggested improvement measures such as approval, inspection, inspection and testing, calibration of monitoring sensors. Conclusion: Applying the improvement measures of the tunnel structure maintenance monitoring to the construction site will increase the efficiency of the maintenance monitoring and contribute to the development of construction monitoring technology.

Evaluation of Durability Performance in Concrete Incorporating Low Fineness of GGBFS (3000 Grade) (저분말도 고로슬래그 미분말(3000급)을 혼입한 콘크리트의 내구성능평가)

  • Lee, Seung-Heun;Cho, Sung-Jun;Kwon, Seung-Jun
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.23 no.4
    • /
    • pp.96-102
    • /
    • 2019
  • When GGBFS(Ground Granulated Blast Furnace Slag) with high blaine is incorporated in concrete, compressive strength in the initial period is improved, but several engineering problems arise such as heat of hydration and quality control. In this paper, compressive strength and durability performance of concrete with 3,000 Grade-low fineness slag are evaluated. Three conditions of concrete mixtures are considered considering workability, and the related durability tests are performed. Although the strength of concrete with 3,000 Grade slag is slightly lower than the OPC(Ordinary Portland Cement) concrete at the age of 28 days, but insignificant difference is observed in long-term compressive strength due to latent hydration activity. The durability performances in concrete with low fineness slag show that the resistances to carbonation and freezing/thawing action are slightly higher than those of concrete with high fineness slag, since reduced unit water content is considered in 3,000 Grade slag mixture. For the long-term age, the chloride diffusion coefficient of the 3000-grade slag mixture is reduced to 20% compared to the OPC mixture, and the excellent chloride resistance are evaluated. Compared with concrete with OPC and high fineness GGBFS, concrete with lower fineness GGBFS can keep reasonable workability and durability performance with reduced water content.

A Study of the Proper Control-Interval through Comparative Analysis on Bridge Maintenance System (교량 적정 점검 주기에 관한 비교 연구)

  • Lee Yong-Su
    • Proceedings of the Korean Institute Of Construction Engineering and Management
    • /
    • autumn
    • /
    • pp.113-118
    • /
    • 2001
  • Bridge Control and Inspection ensures the safety, utility, and durability of Bridge in use. This Paper compares Control-interval of Germany with that of Korea, which was described in the special law recently revised concerning the Safety Checkup of Facilities, and analyzes Period of Damage Discovery that the Damage report of other countries showed. According to a result of the analysis, damage requiring structure repair and reinforcement more frequently been discovered even in less than a decade after the completion of construction. The paper, therefore, suggested the reregulation on the Korean Control Interval on the basis of the result.

  • PDF

암반공학적 측면에서본 신생대 암반비탈면의 공학적 문제 및 대책

  • Shin, Hee-Soon
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2005.10a
    • /
    • pp.285-289
    • /
    • 2005
  • The Cenozoic Era consists of two period , the Tertiary and the Quaternary Period. Weak rock types may include areas containing: 1) poorly cemented or uncemented sediments, 2) highly weathered rock, or 3) fault lines. Especially this paper deal with poorly cemented or uncemented sedimentary rocks in slope. Mechanical weathering is caused by physical processes such as absorption and release of water, and changes in temperature and stress at or near the exposed rock surface. It results in the opening of discontinuities, the formation of new discontinuities by rock fracture, the opening of grain boundaries, and the fracture or cleavage of individual mineral grains. Decomposition causes some silicate minerals such as feldspars to change to clay minerals. There was a strong negative correlation between water absorption and important engineering properties such as strength and durability.

  • PDF

Study on the correlation between long-term exposure tests and accelerated corrosion tests by the combined damage of salts (염해 및 복합열화에 의한 부식촉진시험과 장기폭로 시험의 상관성에 관한 연구)

  • Park, Sang Soon;Lee, Min Woo
    • Corrosion Science and Technology
    • /
    • v.13 no.6
    • /
    • pp.214-223
    • /
    • 2014
  • Interest in the durability assessment and structural performance has increased according to an increase of concrete structures in salt damage environment recent years. Reliable way ensuring the most accelerated corrosion test is a method of performing the rebar corrosion monitoring as exposed directly to the marine test site exposure. However, long-term exposure test has a disadvantage because of a long period of time. Therefore, many studies on reinforced concrete in salt damage environments have been developed as alternatives to replace this. However, accelerated corrosion test is appropriate to evaluate the critical chlorine concentration in the short term, but only accelerated test method, is not easy to get correct answer. Accuracy of correlation acceleration test depends on the period of the degree of exposure environments. Therefore, in this study, depending on the concrete mix material, by the test was performed on the basis of the composite degradation of the salt damage, and investigate the difference of corrosion initiation time of the rebar, and indoor corrosion time of the structure, of the marine environment of the actual environments were inuestigated. The correlation coefficient was derived in the experiment. Long-term exposure test was actually conducted in consideration of the exposure conditions submerged zone, splash zone and tidal zone. The accelerated corrosion tests were carried out by immersion conditions, and by the combined deterioration due to the carbonation and accelerated corrosion due to wet and dry condition.

Durability of the Low Profile Ionescu-Shiley Valve in the Mitral Position (이오네스큐 단고형 승모판의 내구성)

  • 김종환
    • Journal of Chest Surgery
    • /
    • v.25 no.8
    • /
    • pp.863-870
    • /
    • 1992
  • The low profile Ionescu-Shiley pericardial xenograft valve had been initially introduced to have improved hemodynamic performance and expected superior durability, However, subsequent clinical reports and laboratory studies have repeatedly indicated early failure of the valve from mechanical reasons in valve design, A total and consecutive 169 patients underwent isolated MVR with the low profile Ionescu-Shiley valve at Seoul National University Hospital from November 1984 to October 1989 [Group ISLM]. Five patients [3.0%] died within 30 days of surgery, and early survivors were followed up for 734.9 patient-years [Mean$\pm$SD, 4.9$\pm$2.0 years], Late mortality rate was 0.136% /patient-year [pt-yr], Linearized incidences of major complications were: 0.953% embolism /pt-yr; 0.680% bleeding /pt-yr; 0.272% endocarditis /pt-yr; and 0, 408% primary tissue failure [PTF] /pt-yr, The actuarial survival was 99.4$\pm$0.6%, and probabilities of from thromboembolism and from PTF were 90.7$\pm$4.6% and 95.9$\pm$2.6% at 8 years, respectively These results were compared with the clinical data from the 291 patients of isolated MVR with the standard Ionescu-Shiley valve at the same hospital during the period between October 1978 and June 1983 [Group ISUM], Group ISUM included 11% of patients younger than 15 years of age, whereas Group ISLM did no patient of this age. The mean age at the time of surgery was significantly younger in Group ISUM than one in Group ISLM [P<0.001]. Differences were not statistically significant in operative mortality, mean follow-up period and linearized incidences of thromboembolism, bleeding and endocarditis, between two groups, However, the linearized rate of PTF was lower [P<0.001] and probabilities of freedom fro PTF higher [P<0.001] in Group ISLM at least up to postoperative 8 years. While the features of PTF of the standard valve was predominantly degeneration with calcification and stenosis, the ones of the low profile valve was cusp tear and incompetence. It remains, however, to be seen whether the low profile valve fails mostly from mechanical reason, and further follow-up will still be necessary to determine the differences in mode of PTF of two valves.

  • PDF

A Study on Strength and Durability of Vibrated and Rolled Method Mortar Mixed with Desulfurized Gypsum and Ferronickel Slag Fine Powder (탈황석고와 페로니켈슬래그 미분말을 혼합한 진동전압방식 모르타르의 강도 및 내구성에 관한 연구)

  • Yoo, Jeong-Hwan;Park, Sang-Soon
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.9 no.4
    • /
    • pp.545-552
    • /
    • 2021
  • In this study, strength and durability evaluations are performed on vibrated-rolled method mortar mixtures containing desulfurized gypsum and ferronickel slag powder. Desulfurized gypsum and ferronickel slag fine powders were substituted for 25% limestone fine powders u sed in the manu factu re of VR tu bes, and mortar specimens were prepared u sing vibrated-rolled method. Accordingly, flexural and compressive strengths were performed to evaluate the strength, and chlorine ion penetration resistance and sulfuric acid resistance tests were performed to evaluate durability. Flexural and compressive strength were improved in the range 20 to 60% of desu lfu rized gypsu m among admixtu res, and the amou nt of passing charge decreased in the choride ion penetration resistance test in the range of 20 to 80% of desulfurized gypsum. As for the resistance to su lfu ric acid, when the proportion of desu lfu rized in the admixtu re was 40%, the strength and weight change rate according to the immersion period was reduced. Appropriate use of desulfurized gypsum and ferronickel slag powder is expected to improve performance in terms of strength and durability.

A Empirical Study on Durability and Waterproofing Characteristic of Space Multi-Injection Grouting Method (S.M.I 공법의 내구성 및 차수특성에 관한 실험적 연구)

  • Shin, Hyohee;Park, Minchul;Park, Kyeonghan;Suh, Jeeweon;Lee, Song
    • Journal of the Korean GEO-environmental Society
    • /
    • v.14 no.1
    • /
    • pp.53-60
    • /
    • 2013
  • On this study, engineering properties of SGR method and SMI method, which are typical sodium silicate methods, were compared through the laboratory test and durability, strength, waterproof characteristic and environmental effects were compared and analyzed with period and condition of curing on each case. As a result of durability test, volume change of SGR is approximately 23-times greater than SMI and the effects on environment are appeared safe on all method. In case of waterproof characteristic test, permeability coefficient is decreased about 24% on SMI, whereas on SGR permeability coefficient is showed to increase because rapid volume change make wider void. Strength characteristics of SMI are appeared higher about 11-times in case of homogel and 3.9-times in case of sandgel than SGR. Which is because volume change of SMI, caused by leaching, is smaller than SGR.

A Study on Repair Method of Concrete Structures using the Solution of Removing Chloride (염분제거용 약액을 이용한 콘크리트 구조물의 보수공법에 관한 연구)

  • Kim, Woonhak;Hwang, Sungwoon;Kang, Seokwon
    • Journal of the Society of Disaster Information
    • /
    • v.13 no.4
    • /
    • pp.562-569
    • /
    • 2017
  • Reinforced concrete is used for bridges and large structures that are constructed with social overhead capital because they are economically and semi-permanently integrated with reinforcing bar and concrete. However, when the chloride ion in the concrete destroys the passive film of the reinforcing bar by the marine exposure environment and the snow remover used in the winter season, and the reinforcing bar is corroded by various chemical and physical actions, the durability is deteriorated in a short period, and the life span is shortened. In this study, a repair method to recover the durability of the initial structure by effectively removing chloride ion from the damage caused by salting of the above mentioned reinforced concrete was conducted.