• Title/Summary/Keyword: Period Detection

Search Result 1,156, Processing Time 0.027 seconds

A Study on Performance Enhancement of Period Detection in Pulse Wave (맥파의 주기 검출 성능 개선에 관한 연구)

  • Lee, Hyun-Min;Kim, Dong-Jun
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.6
    • /
    • pp.1194-1199
    • /
    • 2009
  • Heart rate may be a very important parameter in human health. To extract heart rate, the electrocardiogram(ECG) is commonly used. But the ECG acquisition procedure is very complex. On the other hand, the acquisition of pulse wave or photoplethysmogram(PPG) is very easy. However, the peak of PPG is not so sharp as ECG. This study tries to enhance the performance of peak detection in PPG signal. The method uses the average slopes around the main peak. The crossing point of the increasing and the decreasing slopes is selected as the peak point of heart rate period. The proposed method showed smoothed heart rate graph and reduced irregularity in heart rate values.

A Study on Speech Period and Pitch Detection for Continuous Speech Recognition (연속음성인식을 위한 음성구간과 피치검출에 관한 연구)

  • Kim Tai Suk;Chang jong chil
    • Journal of Korea Multimedia Society
    • /
    • v.8 no.1
    • /
    • pp.56-61
    • /
    • 2005
  • In this thesis, propose speech period and pitch detection for continuous speech recognition. This mathod is distinguishes between vowel and consonant to frame unit in continuous speech, for distinguishable voice. Powerful extraction of speech period could threshold energy make use of input signal to real noise environment. Also algorithm of this method distinguish between vowel and consonant at the same time in voice make use of zero crossing rate and short time energy to extractible speech period.

  • PDF

Optimal sensing period in cooperative relay cognitive radio networks

  • Zhang, Shibing;Guo, Xin;Zhang, Xiaoge;Qiu, Gongan
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.10 no.12
    • /
    • pp.5249-5267
    • /
    • 2016
  • Cognitive radio is an efficient technique to improve spectrum efficiency and relieve the pressure of spectrum resources. In this paper, we investigate the spectrum sensing period in cooperative relay cognitive radio networks; analyze the relationship between the available capacity and the signal-to-noise ratio of the received signal of second users, the target probability of detection and the active probability of primary users. Finally, we derive the closed form expression of the optimal spectrum sensing period in terms of maximum throughput. We simulate the probability of false alarm and available capacity of cognitive radio networks and compare optimal spectrum sensing period scheme with fixed sensing period one in these performance. Simulation results show that the optimal sensing period makes the cognitive networks achieve the higher throughput and better spectrum sensing performance than the fixed sensing period does. Cooperative relay cognitive radio networks with optimal spectrum sensing period can achieve the high capacity and steady probability of false alarm in different target probability of detection. It provides a valuable reference for choosing the optimal spectrum sensing period in cooperative relay cognitive radio networks.

Autonomic Period Determination for Variable Rate Limiter of Virus Throttling (바이러스 감속기의 가변 비율 제한기를 위한 자율적 주기 결정)

  • Shim, Jae-Hong;Sohn, Jang-Wan
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.32 no.1C
    • /
    • pp.67-77
    • /
    • 2007
  • Virus throttling technique, one of many early worm detection techniques, detects Internet worm propagation by limiting connect requests within a certain ratio. The typical virus throttling controls the period of rate limiter autonomically by utilizing weighted average delay queue length to reduce connection delay time without hanving a large effect on worm detection time. In the existing virus throttling research, a minimum period of variable rate limiter is fired and a turning point which is a point that the period of rate limiter has been being decreased and starts to be increased is also fixed. However, these two performance factors have different effects on worm detection time and connection delay. In this paper, we analyze the effect of minimum period and turning point of variable rate limiter, and then propose an algorithm which determines values of performance factors by referencing current traffic pattern. Through deep experiments, it is verified that the proposed technique is more efficient in respect of reducing worm detection time and connection delay than the existing virus throttling which fixed the performance factors.

Quantifiable and feasible estrus detection using the ultrasonic sensor array and digital infrared thermography

  • Lee, Ji Hwan;Lee, Dong Hoon;Yun, Won;Oh, Han Jin;An, Ji Seon;Kim, Young Gwang;Kim, Gok Mi;Cho, Jin Ho
    • Journal of Animal Science and Technology
    • /
    • v.61 no.3
    • /
    • pp.163-169
    • /
    • 2019
  • Detection of estrus is an essential factor as a method of successful breeding in the sow. As increasing the adaption of the information and communication technology (ICT) into swine industry, this study focuses on a possibility and quantification of standing time, vulva and body temperature as methods of estrus detection, comparing each time and temperature in estrus and non-estrus period, and analyzing each success rate of new and existing methods. Ultrasonic sensor array and digital infrared thermography were used to evaluate whether new methods such as standing time and number, and vulva and skin temperature can be replaced, or these methods can be quantifiable in estrus period. Ultrasonic sensor array was installed beside the stall and digital infrared thermography was placed in the rear of sow to collect the dates of sow in estrus and non-estrus period. This study showed total standing time, number and number over 10 minutes, and vulva temperature of the sow in estrus period were increased (p < 0.05) compared with those of sow in non-estrus period, respectively. Detection of estrus using standing time and vulva temperature tended (p = 0.06) to increase the success rate when artificial insemination (AI) was performed. In conclusion, standing time and vulva temperature increased when estrus happened. Success rate of AI of sow using these methods showed an increasing trend. Therefore, existing method using the naked eye can be replaced to new method such as vulvar temperature and standing time when detecting the estrus.

Accurate Camera Self-Calibration based on Image Quality Assessment

  • Fayyaz, Rabia;Rhee, Eun Joo
    • Journal of Information Technology Applications and Management
    • /
    • v.25 no.2
    • /
    • pp.41-52
    • /
    • 2018
  • This paper presents a method for accurate camera self-calibration based on SIFT Feature Detection and image quality assessment. We performed image quality assessment to select high quality images for the camera self-calibration process. We defined high quality images as those that contain little or no blur, and have maximum contrast among images captured within a short period. The image quality assessment includes blur detection and contrast assessment. Blur detection is based on the statistical analysis of energy and standard deviation of high frequency components of the images using Discrete Cosine Transform. Contrast assessment is based on contrast measurement and selection of the high contrast images among some images captured in a short period. Experimental results show little or no distortion in the perspective view of the images. Thus, the suggested method achieves camera self-calibration accuracy of approximately 93%.

A Method of Failure Detection Rate Calculation for Setting up of Guided Missile Periodic Test and Application Case (유도탄 점검주기 설정을 위한 고장 탐지율 산출 방안 및 적용 사례)

  • Choi, In-Duck
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.42 no.2
    • /
    • pp.28-35
    • /
    • 2019
  • Since guided missiles with the characteristics of the one-shot system remain stored throughout their entire life cycle, it is important to maintain their storage reliability until the launch. As part of maintaining storage reliability, period of preventive test is set up to perform preventive periodic test, in this case failure detection rate has a great effect on setting up period of preventive test to maintain storage reliability. The proposed method utilizes failure rate predicted by the software on the basis of MIL-HDBK-217F and failure mode analyzed through FMEA (Failure Mode and Effect Analysis) using data generated from the actual field. The failure detection rate of using the proposed method is applied to set periodic test of the actual guided missile. The proposed method in this paper has advantages in accuracy and objectivity because it utilizes a large amount of data generated in the actual field.

R-wave Detection Algorithm in ECG Signal Using Adaptive Refractory Period (ECG 신호에서 적응적 불응기를 이용한 R-wave 검출 알고리즘)

  • Kim, Jung-Joon;Kim, Jin-Sub;Park, Kil-Houm
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.50 no.5
    • /
    • pp.242-250
    • /
    • 2013
  • In this paper, R-wave detection algorithm using refractory period to reflect the depolarization and repolarization of the myocardial cells of the heart is proposed. The proposed algorithm detects R-peaks using the features of R-wave and variable refractory period. First, the proposed algorithm extracts candidate R-peaks that have a relatively high potential and calculates the refractory period based on the kurtosis and potential for candidate R-peaks. Next, R-peak is determined by morphological features of the R-wave within the refractory period. In addition, due to less computation in the proposed algorithm, real-time processing is possible. The algorithm is applied to all records of the MIT-BIH arrhythmia database and the obtained results show a competitive detection rate of over 99.7%.

Fluctuations in the Exhaust System -Single Cylinder Misfire- (배기계 압력 변동을 이용한 가솔린 기관의 실화 검출 -단수 실린더 실화-)

  • Sim, K.S.;Bok, J.H.;Kim, S.W.
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.6 no.6
    • /
    • pp.210-217
    • /
    • 1998
  • This paper describes the method for detection of the misfired cylinder using the pressure fluctuations occurred in the exhaust system on an MPI gasoline engine. If misfire is occurred in the cylinder of the gasoline engine, the power of engine gets lost, the fuel consumption and the exhaust emission are increased and the vibration is caused by unsteady torque. Therefore early detection and correction of misfire play a very important role in the proper performance and the exhaust emission. This paper suggests method of misfire detection which affect engine performance. The method is a comparison of average pressure index during the displacement period. Experimental results showed that the method using the pressure fluctuations in the exhaust system is proven to be effective in the detection of misfire on gasoline engine regardless loads and revolutions of the engine. In addition, this method, using the pressure fluctuations in exhaust system is easier than other methods and is not a need of additional reconstruction of engine.

  • PDF

Design of Gate Driver Chip for Ionizer Modules with Fault Detection Function (Fault Detection 기능을 갖는 이오나이저 모듈용 게이트 구동 칩 설계)

  • Jin, Hongzhou;Ha, PanBong;Kim, YoungHee
    • Journal of IKEEE
    • /
    • v.24 no.1
    • /
    • pp.132-139
    • /
    • 2020
  • The ionizer module used in this air cleaner supplies high voltages of 3.5KV / -4KV to the discharge electrode HV+ / HV- using a winding transformer to generate positive and negative ions by electric field radiation of carbon fiber brush. The ionizer module circuit using the existing MCU has the disadvantage of large PCB size and expensive price, and the gate driver chip using the existing ring oscillator has oscillation period sensitive to PVT (Process-Voltage-Temperature) fluctuation and there is risk of fire or electric shock because there is no fault detection function by short circuit of HV+ and GND as well as HV- and GND. Therefore, in this paper, even though PVT fluctuates, by using 7-bit binary up counter, HV+ voltage reaches the target voltage by adjusting oscillation period. And an HV+ short fault detection circuit for detecting a short circuit between HV+ and GND, an HV- short fault detection circuit for detecting a short circuit between HV- and GND, and an OVP (Over-Voltage Protection) for detecting that HV+ rises above an overvoltage are newly proposed.