• Title/Summary/Keyword: Performed position

Search Result 3,297, Processing Time 0.032 seconds

MEDIAN CLEFT OF THE LOWER LIP AND MANDIBLE;A CASE REPORT (하순 및 하악골 정중열의 치험례)

  • Cha, Doo-Won;Kim, Hyun-Soo;Baek, Sang-Heum;Kim, Chin-Soo;Byeon, Ki-Jeong
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.23 no.3
    • /
    • pp.263-269
    • /
    • 2001
  • Median cleft of the lower lip and/or mandible is a rare congenital anomaly, first mentioned by Couronne in 1819. Monroe(1966), Fujino(1970), Ranta(1984) and Oostrom(1996) conducted comprehensive reviews and list cases in literature. Median cleft varies greatly, from a simple vermilion notch to a complete cleft of the lip involving the tongue, the chin, the mandible, the supporting structures of the median of the neck, and the manubrium sterni. The associated anomalies include ankyloglossia, cleft tongue, neck contraction, heart lesion, absence of hyoid bone, and so on. The etiology of median cleft is unknown. Various possibilities, such as failure of mesodermal penetration into the midline, failure of fusion of mandibular processes, external factors apart from the embryogenic pattern such as pressure, position in utero, circulatory failure caused placental adhesion, diseases in pregnancy, and so on, have been discussed. A 8-year-old girl was referred to the Dept. of Oral & Maxillofacial Surgery, Kyungpook National University Hospital and had been aware of the fact that at birth "she had something wrong with her mouth." Shortly after birth she had been examined by a plastic surgeon and at that time surgical procedure had been performed to release the tongue from the lower jaw and lip at local hospital. On admission, she had a slight notching of lower lip and two fibrous frenum ran from the lip along the ventral surface of the tongue, diastema between her mandibular central incisors, and slightly constricted bifid mandible associated independent movement of the two halves of mandible. The patient had autogenous iliac bone graft to reconstruct the mandibular midline defect. The postoperative result was uneventful. In future, the correction of the soft tissue deformities such as notching of the lower lip and partial ankyloglossia will be required for the esthetic and functional improvement.

  • PDF

The Influence of gender or culture on determining esthetic facial profile (심미적 측모 판단에 미치는 성별과 문화의 영향력)

  • Ko, Su-Jin;Kim, Hyun-Soon;Kim, Young-Jin
    • The korean journal of orthodontics
    • /
    • v.31 no.3 s.86
    • /
    • pp.301-309
    • /
    • 2001
  • Because many of patients seeking orthodontic treatment worry about the facial appearance and their chief motivation for orthodontic treatment is facial esthetics, it is critical to understand the influence of gender or culture on the evaluation of profile esthetics. The purpose of this study was to find out any influence of gender or culture on judging good facial profile. 4 different groups were asked to evaluate 133 facial profiles to test the influence of gender or culture on judging good facial profiles. Those 4 groups consisted of 10 Korean males, 10 Korean females, 10 Korean American males, and 10 Korean American females. 2 evaluation systems were introduced, absolute and relative. Soft tissues of selected good profile group were analyzed and statistic analysis was performed. Conclusions were as follows 1. Inter-evaluator difference for judging good facial profile was statistically significant, even if there was general agreement for the best profile among 40 raters. 2. Gender difference under the same cultural environment was not significant statistically. 3. The same ethnic groups with different cultural background showed statistically different preference on judging good Profile. 4. Good facial profile group had their own characteristics compared to remaining group in several soft tissue measurements which were vertical facial ratio, soft tissue facial convexity, and antero-posterior relative lip position.

  • PDF

Case Studies on Distributed Temperature and Strain Sensing(DTSS) by using an Optical fiber (광섬유 센서를 이용한 온도 및 변형 모니터링에 대한 현장응용 사례)

  • Kim, Jung-Yul;Kim, Yoo-Sung;Lee, Sung-Uk;Min, Kyoung-Ju;Park, Dong-Su;Pang, Gi-Sung;Kim, Kang-Sik
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2006.03a
    • /
    • pp.86-95
    • /
    • 2006
  • Brillouin backscatter is a type of reflection that occurs when light is shone into an optical fibre. Brillouin reflections are very sensitive to changes in the fibre arising from external effects, such as temperature, strain and pressure. We report here several case studies on the measurement of strain using Brillouin reflections. A mechanical bending test of an I beam, deployed with both fiber optic sensors and conventional strain gauge rosettes, was performed with the aim of evaluating: (1) the capability and technical limit of the DTSS technology for strain profile sensing; (2) the reliability of strain measurement using fiber optic sensor. The average values of strains obtained from both DTSS and strain gauges (corresponding to the deflection of I beam) showed a linear relationship and an excellent one-to-one match. A practical application of DTSS technology as an early warning system for land sliding or subsidence was examined through a field test at a hillside. Extremely strong, lightweight, rugged, survivable tight-buffered cables, designed for optimal strain transfer to the fibre, were used and clamped on the subsurface at a depth of about 50cm. It was proved that DTSS measurements could detect the exact position and the progress of strain changes induced by land sliding and subsidence. We also carried out the first ever distributed dynamic strain measurement (10Hz) on the Korean Train eXpress(KTX) railway track in Daejeon, Korea. The aim was to analyse the integrity of a section of track that had recently been repaired. The Sensornet DTSS was used to monitor this 85m section of track while a KTX train passed over. In the repaired section the strain increases to levels of 90 microstrain, whereas in the section of regular track the strain is in the region of 30-50 microstrain. The results were excellent since they demonstrate that the DTSS is able to measure small, dynamic changes in strain in rails during normal operating conditions. The current 10km range of the DTSS creates a potential to monitor the integrity of large lengths of track, and especially higher risk sections such as bridges, repaired track and areas at risk of subsidence.

  • PDF

The Effect of Diluent Gases on the Growth Behavior of CVD SiC (희석기체가 화학증착 탄화규소의 성장거동에 미치는 영향)

  • 최두진;김한수
    • Journal of the Korean Ceramic Society
    • /
    • v.34 no.2
    • /
    • pp.131-138
    • /
    • 1997
  • Silicon carbide films were chemically vapor deposited onto graphite substrates using MTS(Ch3SiCl3) as a source and Ar or H2 as a diluent gas. The experiments were performed at a fixed condition such as a de-position temperature of 130$0^{\circ}C$, a total pressure of 10 torr, and a flow rate of 100 sccm for each MTS and carrier gas. The purpose of this study is to consider the variation of the growth behavior with the addition of each diluent gas. It is shown that the deposition rate leads to maximum value at 200 sccm addition ir-respective of diluent gases and the deposition rate of Ar addition is faster than that of H2 one. It seems that these characteristics of deposition rate are due to varying interrelationship between boundary layer thick-ness and the concentration of a source with each diluent gas addition, when overall deposition rate is con-trolled by mass transport kinetics. The preferred orientation of (220) plane was maintained for the whole range of Ar addition. However, above 200 sccm addition, especially that of (111) plane was more increased in proportion to H2 addition. Surface morphologies of SiC films were the facet structures under Ar addition, but those were gradually changed from facet to smooth structures with H2 addition. Surface roughness be-came higher in Ar, but it became lower in H2 with increasing the amount of diluent gas.

  • PDF

A Study on the Micro-defects Characteristics and Latch-up Immune Structure by RTA in 1MeV P Ion Implantation (1MeV 인 이온 주입시 RTA에 의한 미세결함 특성과 latch-up 면역에 관한 구조 연구)

  • Roh, Byeong-Gyu;Yoon, Seok-Beom
    • Journal of IKEEE
    • /
    • v.2 no.1 s.2
    • /
    • pp.101-107
    • /
    • 1998
  • This paper is studied micro-defect characteristics by phosphorus 1MeV ion implantation and Rs, SRP, SIMS, XTEM for the RTA process was measured and simulated. As the dose is higher, the Rs is lower. When the dose are $1{\times}10^{13}/cm^2,\;5{\times}10^{13}/cm^2,\;1{\times}10^{14}/cm^2$, the Rp are $1.15{\mu}m,\;1.15{\mu},\;1.10{\mu}m$ respectively. As the RTA time is longer, the maximum concentration position is deeper from the surface and the concentration is lower. Before the RTA was done, we didn't observe any defect. But after the RTA process was done, we could observe the RTA process changed the micro-defects into the secondary defects. The simulation using the buried layer and connecting layer structure was performed. As results, the connecting layer had more effect than the buried layer to latch-up immune. Trigger current was more $0.6mA/{\mu}m$ and trigger voltage was 6V at dose $1{\times}10^{14}/cm^2$ and the energy 500KeV of connecting layer Lower connecting layer dose, latch-up immune characteristics was better.

  • PDF

The Development and Application of the New Model of Moon Phases (새로운 달 위상 모형의 개발과 그 적용)

  • Chae, Dong-Hyun
    • Journal of Korean Elementary Science Education
    • /
    • v.27 no.4
    • /
    • pp.385-398
    • /
    • 2008
  • The purpose of this study is to understand the effect of The Model of Phases of the Moon on conception changes for preservice teachers. The researcher interviewed two preservice teachers under the agreement with them on their participation in the research just before he performed a class using The New Model of Phases of the Moon. The post-interview with the same content as the pre-interview was preformed one month later. The main content of the interview is as follows; 'Explain the shape of the Moon by drawing it.', 'Explain the relative different position among the Sun, Earth, and Moon depending on phases of the Moon by drawing them.', 'What do you think of the cause of phases of the Moon?', 'Draw a picture to explain why we always see only one side of the moon.' The results of the research are as follows. First, the class with New Model of Phases of the Moon was able to perceive the relationship of Sun, Earth, and Moon in three-dimensions rather than in two-dimensions and it helped to change their misconception that the Moon's shadow causes the Moon's shape. Secondly, the class with New Model of Phases of the Moon helped preservice teachers understand better the different positional relationships among the Sun, Earth, and Moon depending on the Moon shapes. Third, the class adopting the New Model of Phases of the Moon help preservice teachers form scientific conceptions on the causes of phase change of the Moon. Fourth, the class with the New Model of Phases of the Moon is not appropriate for explaining the reason why only one face of the Moon is seen. Based upon the results above, the researcher realized the limitation of this model and suggested that this model would help learners understand phase change of the Moon and increase space perception ability.

  • PDF

Measurement of soft tissue thickness on posterior palatal area by using computerized tomography in Korean population (전산화단층촬영법을 통한 한국인의 구개 저작 점막 두께에 대한 연구)

  • Song, Ji-Eun;Chae, Gyung-Joon;Jung, Ui-Won;Kim, Chang-Sung;Choi, Seong-Ho;Cho, Kyoo-Sung;Kim, Chong-Kwan;Chai, Jung-Kiu
    • Journal of Periodontal and Implant Science
    • /
    • v.37 no.1
    • /
    • pp.103-113
    • /
    • 2007
  • The purpose of this study was to measure the thickness of masticatory mucosa in the hard palate as a donor site for mucogingival surgery by using computerized tomography(CT), Thickness measurements were performed in 84 adult patients who took CT on maxilla for implant surgery and 24 standard measurement points were defined in the hard palate according to the gingival margin and mid palatal suture. Radiographic measurements were utilized after calibration for standardization. Data were analyzed to determine the differences in mucosal thickness by gender, age, tooth positions and depth of palatal vault. The results of this study were as follows: 1. Mean thickness of palatal masticatory mucosa was $3.93{\pm}0.6mm$ and females had significantly thinner mean masticatory mucosa($3.76{\pm}0.56mm$) than males($4.04{\pm}0.6mm$)(p<0.05). 2. The thickness of palatal masticatory mucosa increased by aging. 3. Depending on position, masticatory mucosa thickness increased from canine to premeolar, but decreased at the first molar, and increased again in the second molar region(p<0.0001). 4. No significant difference in mean thickness of palatal masticatory mucosa were indentified between low palatal vault group and high palatal vault group(p>0.05). The results suggest that canine and premolar area appears to be the most appropriate donor site for soft tissue grafting procedure. The measurement of the thickness of palatal masticatory mucosa by using computerized tomography can offer useful information clinically but further studies in as-sessing the validity and reliability of the method using computerized tomography is needed.

Ex Vivo ${1}^H$ MR Spectroscopy: Normal gastric and cancer tissue (정상 위 조직과 위암 조직의 시험관 내 수소자기공명분광)

  • Cho Ji Youn;Shin Oon Jae;Choi Ki Seung;Kim Su Hyun;Eun Choong Ki;Yang Young Il;Lee Jung Hee;Mun Chi Woong
    • Journal of Gastric Cancer
    • /
    • v.3 no.3
    • /
    • pp.151-157
    • /
    • 2003
  • Purpose: In this study, we attempted to ascertain the proton magnetic resonance spectroscopy (${1}^H$ MRS) peak characteristics of human gastric tissue layers and finally to use the metabolic peaks of MRS to distinguish between normal and abnormal gastric specimens. Materials and Methods: Ex-vivo ${1}^H$ MRS examinations of thirty-five gastric specimens were performed to distinguish abnormal gastric tissues invaded by carcinoma cells from normal stomach-wall tissues. High-resolution 400-MHz (9.4-T) ${1}^H$ nuclear magnetic resonance (NMR) spectra of two gastric layers, a proper muscle layer, and a composite mucosasubmucosa layer were compared with those of clinical 64- MHz (1.5-T) MR spectra. Three-dimensional spoiled gradient recalled (SPGR) images were used to determine the size and the position of a voxel for MRS data collection. Results: For normal gastric tissue layers, the metabolite peaks of 400-MHz ${1}^H$ MRS were primarily found to be as follows: lipids at 0.9 ppm and 1.3 ppm; alanine at 1.58 ppm; N-acetyl neuraminic acid (sialic acid) at 2.03 ppm; and glutathione at 2.25 ppm in common. The broad and featureless featureless spectral peaks of the 64-MHz MRS were bunched near 0.9, 1.3, and 2.0, and 2.2 ppm in human specimens without respect to layers. In a specimen (Borrmmann type III) with a tubular adenocarcinoma, the resonance peaks were measured at 1.26, 1.36 and 3.22 ppm. All the peak intensities of the spectrum of the normal gastric tissue were reduced, but for gastric tumor tissue layers, the lactate peak split into 1.26 and 1.39 ppm, and the peak intensity of choline at 3.21 ppm was increased. Conclusion: We found that decreasing lipids, an increasing lactate peak that split into two peaks, 1.26 ppm and 1.36 ppm, and an increasing choline peak at 3.22 ppm were markers of tumor invasion into the gastric tissue layers. This study implies that MR spectroscopy can be a useful diagnostic tool for gastric cancer.

  • PDF

In Silico Molecular Docking Comparison of Tubocurarine and the Active Ingredients of Cimicifugae rhizoma on Acetylcholine Binding Proteins (In Silico 분자결합 분석방법을 활용한 tubocurarine과 승마 추출성분 actein의 아세틸콜린 결합 단백질 활성 부위에 대한 결합 친화도 비교 분석)

  • Kim, Dong-Chan
    • Journal of Life Science
    • /
    • v.28 no.4
    • /
    • pp.408-414
    • /
    • 2018
  • Actein is the well-known active ingredient of Cimicifugae rhizoma (Black cohosh). In this study, we investigated and compared the binding affinity of tubocurarine, actein, and actein derivatives on the B&C domain of the acetylcholine binding protein through in silico computational docking studies. The three-dimensional crystallographic structure of the acetylcholine binding protein B&C domain was obtained from the PDB database (PDB ID: 2XYT). An in silico computational autodocking analysis was performed using PyRx, Autodock Vina, Discovery Studio Version 4.5, and NX-QuickPharm based on scoring functions. The actein showed an optimum binding affinity (docking energy), with the acetylcholine binding protein at -10.50 kcal/mol as compared to the tubocurarine (-9.80 kcal/mol). The interacting amino acids tryptophan 84 and tryptophan 147, in the B domain of the acetylcholine binding protein active site, significantly interacted with the actein and 27-deoxyactein, and (26R)-actein. The centroid XYZ grid position of the tubocurarine was X=38.300689, Y=112.053467, and Z=51.991022, but the actein and its derivatives showed values around X=26.4, Y=127.3, Z=43.7. These results clearly indicated that actein and its derivatives could be a more potent antagonist to the acetylcholine binding protein than tubocurarine. Therefore, the extract of Cimicifugae rhizoma or actein containing biomaterials can substitute for the botulinum toxin-mediated acetylcholine receptor regulation, and be applied to the anti-wrinkle cosmetics industry.

Examination of Forced Convection Heat Transfer Performance of a Twist-Vane Spacer Grid for a Dual-Cooled Annular Fuel Assembly (이중냉각 환형핵연료 집합체를 위한 비틀림 혼합날개 지지격자의 강제대류열전달 성능 검토)

  • Lee, Chi Young
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.41 no.1
    • /
    • pp.53-62
    • /
    • 2017
  • The forced convection heat transfer performance of a twist-vane spacer grid for a dual-cooled annular fuel assembly was examined experimentally. The twist-vane spacer grid was uniquely designed to enhance mixing inside subchannels and mixing between adjacent subchannels. For testing, a $4{\times}4$ square-arrayed rod bundle with narrow gaps between rods was prepared as the dual-cooled annular fuel assembly to be simulated. The pitch-to-rod diameter ratio of simulated dual-cooled annular fuel assembly was 1.08. The experiments were performed under the following conditions: axial bulk velocity, 1.5 m/s and heat flux, $26kW/m^2$. With regard to the circumferential temperature distribution, the lowest rod-wall temperatures upstream and downstream were measured at the subchannel center and the position toward the tip of twist-vane, respectively. With regard to the axial temperature distribution, behind the twist-vane spacer grid, the rod-wall temperature decreased drastically, and the Nusselt number was enhanced by up to 56 %. The present measured data indicate that the twist-vane spacer grid can effectively improve the forced convection heat transfer in the dual-cooled annular fuel assembly with narrow gaps.