• Title/Summary/Keyword: Performance-index

Search Result 4,768, Processing Time 0.029 seconds

Relationships of Plasma Insulin-like Growth Factor (IGF)-I and IGF-II Concentrations to Litter Size (Landrace와 Yorkshire 돼지에서 혈장의 Insulin-like Growth Factor (IGF)-I과 IGF-II 농도와 산자수 및 비유성적과의 관계)

  • Lee, C. Y.;Baik, K. H.;Lee, D. H.;Park, H. C.
    • Journal of Animal Science and Technology
    • /
    • v.45 no.1
    • /
    • pp.33-40
    • /
    • 2003
  • The present study was undertaken to find relationships of plasma insulin-like growth factor (IGF)-I and IGF-II concentrations to litter size and lactation performance. Sixty pure-bred Landrace and Yorkshire pigs having similar farrowing weeks which had been selected from a large number of pregnant gilts and sows were divided into low- (<${\mu}$-0.5SD) and high-litter size (>${\mu}$+0.5 SD) lines under a 2 (breed)${\times}$2 (line) factorial arrange of treatments. After adjusting the litter size to nine piglets per sow at farrowing, total litter weight was measured at three weeks postpartum at weaning as an index of milk yield. Blood samples were obtained from the jugular vein at day (d)-90 pregnancy (Px) and at d-15 postpartum. The litter size or the number of piglets born during the present experiment and the average litter size during the entire parities up to the present one were greater in the high-line than in the low-line by 3.7 and 2.4 piglets, respectively (P<0.01); effect of the breed on litter size was not significant. Plasma IGF-II concentration at d-90 Px was greater in the high-line than in the low-line. Litter size and d-90 Px IGF-I concentration were negatively correlated in Landrace (r=-0.46; P<0.05) and tended to be negatively correlated in Yorkshire (r=-0.31; P=0.09), which resulted in a significant negative correlation between these two variables in total animals (r=-0.35; P<0.01). Litter weight at weaning was not different between the two breeds or lines. Relationships between the litter weight and IGF concentration were not consistent across the breed ${\times}$ physiological stage combinations. Results suggest that d-90 Px IGF concentrations may be indicative of the litter size at impending farrowing.

A Case of Childhood Obstructive Sleep Apnea Syndrome with Co-morbid Attention Deficit Hyperactivity Disorder Treated with Continuous Positive Airway Pressure Treatment (지속적(持續的) 상기도(上氣道) 양압술(陽壓術)을 시행(施行)하여 치료효과(治療效果)를 본 주의력(注意力) 결핍(缺乏).과잉(過剩) 운동장애(運動障碍)를 동반(同伴)한 소아기(小兒基) 폐쇄성(閉鎖性) 수면무호흡증(睡眠無呼吸症) 1례(例))

  • Sohn, Chang-Ho;Shin, Min-Sup;Hong, Kang-E;Jeong, Do-Un
    • Sleep Medicine and Psychophysiology
    • /
    • v.3 no.1
    • /
    • pp.85-95
    • /
    • 1996
  • Obstructive sleep apnea syndrome(OSAS) in childhood is unique and different n-om that in adulthood in several aspects, including pathophysiology, clinical features, diagnostic criteria, complications, management, and prognosis. Characteristic features of childhood OSAS in comparison with the adult form are the variety of severe complications such as developmental delay, more prominent behavioral and cognitive impairments, vivid cardiovascular symptoms, and increased death risk, warranting a special attention to the possible diagnosis of OSAS in children who snore. However, the childhood OSAS is often neglected and unrecognized. We, therefore, report a case of very severe OSAS in a 5-year-old boy who was sucessfully treated with continuous positive airway pressure(CPAP) treatment. Interestingly, the patient was comor-bid with the attention deficit hyperactivity disorder. Prior to the initial visit to us, adenotonsillectomy had been done at the age of 4 with no significant improvement of apneic symptoms and heavy snoring. On the initial diagnostic procedures, marked degree of snoring was audible even in the daytime wake state and the patient was observed to be very hyperactive. Increased pulmonary vascularity with borderline cardiomegaly was noted on chest X-ray. The baseline polysomnography revealed that the patient was very sleep-apneic and snored very heavily, with the respiratory disturbance index(RDI) of 46.9 per hour of sleep, the mean SaO2 of 78.8%, and the lowest SaO2 of 40.0%(the lowest detectable oxygen level by the applied oxymeter). The second night polysomnography was done for CPAP titration and the optimal pressure turned out to be $8.0\;cmH_2O$. The applied CPAP treatment was well tolerated by the patient and was found to be very effective in alleviating heavy snoring and severe repetitive sleep apneas. After 18 months of the CPAP treatment, the patient was followed up with nocturnal polysomnography(baseline and CPAP nights) and clinical examination. Sleep apneas were still present without CPAP on the baseline night. However, the severity of OSAS was significantly decreased(RDI of 15.7, mean SaO2 of 96.2%, and the lowest SaO2 of 83.0%), compared to the initial polysomnographic findings before initiation of long-term CPAP treatment. Wechsler intelligence tests done before and after the CPAP treatment were compared with each other and surprising improvement of intelligence(total 9 points, performance 16 points) was noted. Clinically he was found to be markedly improved in his attention deficit hyperactive behavior after CPAP treatment, but with minimal change of TOVA(test of variables of attention) scores except conversion of reaction time score into normal range. On the chest X-ray taken after 18 months of CPAP application, the initial cardiopulmonary abnormalities were not found at all. We found that the CPAP treatment in a young child is very effective, safe, and well-tolerated and also improves the co-morbid attention deficit hyperactive symptoms. Overall, the growth and development of the child has been facilitated with the long-term use of CPAP. Cardiovascular complications induced by OSAS have been also normalized with CPAP treatment. We suggest that early diagnosis and active treatment intervention of OSAS in children are crucial in preventing and ameliorating possible serious complications caused by repetitive sleep apneas and consequent hypoxic damage during sleep.

  • PDF

Antioxidants in Serum and Induced Sputum of COPD Patients (만성폐쇄성폐질환 환자의 혈청 및 유도객담에서의 항산화제)

  • Park, Hyeon-Kwan;Yu, Young-Kwon;Kim, Kyu-Sik;Lim, Sung-Chul;Kim, Young-Chul;Park, Kyung-Ok
    • Tuberculosis and Respiratory Diseases
    • /
    • v.50 no.2
    • /
    • pp.158-170
    • /
    • 2001
  • Background : Although an oxidants and antioxidants imbalance has been considered in the pathogenesis of chronic obstructive pulmonary disease (COPD), there is a paucity of reports focussing on the smoking-induced changes of oxidants and antioxidants in COPD. Method : The concentration of antioxidants (ascorbic acid, uric acid, retinol, and $\alpha$- & $\gamma$-tocopherol) was measured in the serum and induced sputum of 30 healthy controls and 34 stable COPD patients using high performance liquid chromatography (HPLC). The inhibition of lipid peroxidation as an index of antioxidant capacity was measured in the serum by a TBA assay. Results : The serum concentration of ascorbic acid, $\alpha$-tocopherol, and retinol were significantly lower in the patients with COPD than in healthy controls ($484.8{\pm}473.3$ vs $1497.8{\pm}819.2\;pmol/L$, $48.38{\pm}17.34$ vs $73.96{\pm}26.29\;pmol/L$, p<0.001, and $9.51{\pm}8.33$ vs $15.01{\pm}5.88\;pmol/L$, p<0.05, respectively, mean$\pm$SD). However, there were little differences in the ascorbic acid and uric acid concentrations in the induced sputum between the COPD patients and the controls. The induced sputum to serum ratio of ascorbic acid was significantly higher in COPD patients compared with healthy control (0.375 vs 0.085, p<0.05). In the normal controls, the serum ascorbic acid concentration was lower in smokers than in nonsmokers ($1073{\pm}536$ vs $1757{\pm}845\;pmol/L$, p<0.05), but the level was still higher than that of the COPD patients (p<0.05). The serum retinol levels were correlated with $FEV_1$ in COPD patients (r=0.58, p<0.05). The products of lipid peroxidation were increased in normal smokers and COPD compared with norma1 nonsmokers ($115.56{\pm}19.93$ vs $120.02{\pm}24.56$ vs $91.87{\pm}20.71\;{\mu}mol/{\mu}mol$ Pi of liposome, p<0.05). Conclusion : Cigarette smoking may induce the dep1etion of serum antioxidants and this depletion of antioxidants is suggested to play a role in the pathogenesis of COPD.

  • PDF

A Comparative Study on Thermal and Belt Press Dewatering for Waterworks Sludge Rduction (열 탈수와 벨트프레스 탈수장치의 현장적용에 따른 탈수성 비교연구)

  • Lee, Jung-Eun
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.28 no.10
    • /
    • pp.1016-1023
    • /
    • 2006
  • The water content of dewatered cake produced from belt press dewatering equipment was about 75 wt% which was some high to handle it, so the equipment contained a limit at the economical and environmental aspect. The thermal dewatering equipment built as an alternative to overcome several problems was set up at the sludge treatment field and estimated some feasibility as comparison with the dewatering performance of belt press. First, dewatering properties of waterworks sludge was analyzed by monthly. The sludge of a water shortage season contained a high organic content which led to be difficult to dewater the cake, the other side the sludge of rainwater season was ease to dewater because of low organic content. According to the results to analysis the water content of dewatered cake produced from two equipments on the base of the seasonal dewatering properties, the water content of dewatered cake produced from thermal dewatering for sludge of water shortage season was $41.6{\sim}48.3$ wt% and $71{\sim}84$ wt% from belt press. In the case of rainwater season, the water content of dewatered cake produced from thermal dewatering was $34{\sim}37.7$ wt% and $57{\sim}70$ wt% from belt press. It was understood that thereduction of water content of cake by thermal dewatering was larger than belt press. The economical aspect for two equipments was evaluated on considering the reduction of cake treatment amount as the decrease of water content of cake. When putting the cost index of thermal dewatering into 100, belt press was 121. This meant that thermal dewater was more economical than belt press by about 20% in the side of construction and operation. In conclusion, thermal dewatering equipment was estimated by producing the low water content dewatered cake as well as being operated with low coat.

Sugar Contents Analysis of Retort Foods (레토르트식품에 함유되어 있는 당 함량 분석)

  • Jeong, Da-Un;Im, Jun;Kim, Cheon-Hoe;Kim, Young-Kyoung;Park, Yoon-Jin;Jeong, Yoon-Hwa;Om, Ae-Son
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.44 no.11
    • /
    • pp.1666-1671
    • /
    • 2015
  • The purpose of this study was to provide trustworthy nutritional information by analyzing sugar contents of commercial retort foods. A total of 70 retort food samples were collected, which included curry (n=21), blackbean- sauce (n=16), sauce (n=17), and meat (n=16) from markets in Seoul and Gyeonggi-do. Contents of sugars such as glucose, fructose, sucrose, maltose, and lactose were analyzed in retort foods by using a high performance liquid chromatography-refractive index detector and compared to their assigned values on nutritional information labels. Analyzed sugar contents of curries, black-bean-sauces, sauces, and meats ranged from 1.05~4.63 g/100 g, 1.76~5.16 g/100 g, 0.35~25.44 g/100 g, and 1.98~11.07 g/100 g, respectively. Sauces were found to contain the highest amounts of total sugar. These analysis values were equivalent to the reference values indicated on nutrition labels, which were 40~119.5% for curries, 29~118% for black-bean-sauces, 18~118% for sauces, and 70~119.8% for meats. Therefore, this study provides reliable analytical values for sugar contents in retort foods.

Analysis on the Dosimetric Characteristics of Tangential Breast Intensity Modulated Radiotherapy (유방암의 접선 세기조절 방사선치료 선량 특성 분석)

  • Yoon, Mee Sun;Kim, Yong-Hyeob;Jeong, Jae-Uk;Nam, Taek-Keun;Ahn, Sung-Ja;Chung, Wong-Ki;Song, Ju-Young
    • Progress in Medical Physics
    • /
    • v.23 no.4
    • /
    • pp.219-228
    • /
    • 2012
  • The tangential breast intensity modulated radiotherapy (T-B IMRT) technique, which uses the same tangential fields as conventional 3-dimensional conformal radiotherapy (3D-CRT) plans with physical wedges, was analyzed in terms of the calculated dose distribution feature and dosimetric accuracy of beam delivery during treatment. T-B IMRT plans were prepared for 15 patients with breast cancer who were already treated with conventional 3D-CRT. The homogeneity of the dose distribution to the target volume was improved, and the dose delivered to the normal tissues and critical organs was reduced compared with that in 3D-CRT plans. Quality assurance (QA) plans with the appropriate phantoms were used to analyze the dosimetric accuracy of T-B IMRT. An ionization chamber placed at the hole of an acrylic cylindrical phantom was used for the point dose measurement, and the mean error from the calculated dose was $0.7{\pm}1.4%$. The accuracy of the dose distribution was verified with a 2D diode detector array, and the mean pass rate calculated from the gamma evaluation was $97.3{\pm}2.9%$. We confirmed the advantages of a T-B IMRT in the dose distribution and verified the dosimetric accuracy from the QA performance which should still be regarded as an important process even in the simple technique as T-B IMRT in order to maintain a good quality.

Recent Progress in Air Conditioning and Refrigeration Research : A Review of Papers Published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 2007 (설비공학 분야의 최근 연구 동향 : 2007년 학회지 논문에 대한 종합적 고찰)

  • Han, Hwa-Taik;Shin, Dong-Sin;Choi, Chang-Ho;Lee, Dae-Young;Kim, Seo-Young;Kwon, Yong-Il
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.20 no.12
    • /
    • pp.844-861
    • /
    • 2008
  • The papers published in the Korean Journal of Air-Conditioning and Refrigeration Engineering during the year of 2007 have been reviewed. Focus has been put on current status of research in the aspect of heating, cooling, ventilation, sanitation and building environments. The conclusions are as follows. (1) The research trends of fluid engineering have been surveyed as groups of general fluid flow, fluid machinery and piping, etc. New research topics include micro nano fluid, micropump and fuel cell. Traditional CFD was still popular and widely used in research and development. Studies about fans and pumps were performed in the field of fluid machinery. Characteristics of flow and fin shape optimization are studied in the field of piping system. (2) The research works on heat transfer have been reviewed in the field of heat transfer characteristics, heat exchangers, and desiccant cooling systems. The research on heat transfer characteristics includes thermal transport in pulse tubes, high temperature superconductors, ground heat exchangers, fuel cell stacks and ice slurry systems. For the heat 'exchangers, the research on pin-tube heat exchanger, plate heat exchanger, condensers and gas coolers has been cordially implemented. The research works on heat transfer augmenting tubes have been also reported. For the desiccant cooling systems, the studies on the design and operating conditions for desiccant rotors as well as performance index are noticeable. (3) In the field of refrigeration, many papers were presented on the air conditioning system using CO2 as a refrigerant. The issues on the two-stage compression, the oil selection, and the appropriate oil charge were treated. The subjects of alternative refrigerants were also studied steadily. Hydrocarbons, DME and their mixtures were considered and various heat transfer correlations were proposed. (4) Research papers have been reviewed in the field of building facilities by grouping into the researches on heat and cold sources, air conditioning and air cleaning, ventilation and fire research including tunnel ventilation, flow control of piping system, and sound research with drain system. Main focuses have been addressed to the promotion of efficient or effective use of energy, which helps to save energy and results in reduced environmental pollution and operating cost. (5) Studies were mostly focused on analyzing the indoor environment in various spaces like cars, old tombs, machine rooms, and etc. in an architectural environmental field. Moreover, subjects of various fields such as the evaluation of noise, thermal environment, indoor air quality and development of energy analysis program were researched by various methods of survey, simulation, and field experiment.

The NCAM Land-Atmosphere Modeling Package (LAMP) Version 1: Implementation and Evaluation (국가농림기상센터 지면대기모델링패키지(NCAM-LAMP) 버전 1: 구축 및 평가)

  • Lee, Seung-Jae;Song, Jiae;Kim, Yu-Jung
    • Korean Journal of Agricultural and Forest Meteorology
    • /
    • v.18 no.4
    • /
    • pp.307-319
    • /
    • 2016
  • A Land-Atmosphere Modeling Package (LAMP) for supporting agricultural and forest management was developed at the National Center for AgroMeteorology (NCAM). The package is comprised of two components; one is the Weather Research and Forecasting modeling system (WRF) coupled with Noah-Multiparameterization options (Noah-MP) Land Surface Model (LSM) and the other is an offline one-dimensional LSM. The objective of this paper is to briefly describe the two components of the NCAM-LAMP and to evaluate their initial performance. The coupled WRF/Noah-MP system is configured with a parent domain over East Asia and three nested domains with a finest horizontal grid size of 810 m. The innermost domain covers two Gwangneung deciduous and coniferous KoFlux sites (GDK and GCK). The model is integrated for about 8 days with the initial and boundary conditions taken from the National Centers for Environmental Prediction (NCEP) Final Analysis (FNL) data. The verification variables are 2-m air temperature, 10-m wind, 2-m humidity, and surface precipitation for the WRF/Noah-MP coupled system. Skill scores are calculated for each domain and two dynamic vegetation options using the difference between the observed data from the Korea Meteorological Administration (KMA) and the simulated data from the WRF/Noah-MP coupled system. The accuracy of precipitation simulation is examined using a contingency table that is made up of the Probability of Detection (POD) and the Equitable Threat Score (ETS). The standalone LSM simulation is conducted for one year with the original settings and is compared with the KoFlux site observation for net radiation, sensible heat flux, latent heat flux, and soil moisture variables. According to results, the innermost domain (810 m resolution) among all domains showed the minimum root mean square error for 2-m air temperature, 10-m wind, and 2-m humidity. Turning on the dynamic vegetation had a tendency of reducing 10-m wind simulation errors in all domains. The first nested domain (7,290 m resolution) showed the highest precipitation score, but showed little advantage compared with using the dynamic vegetation. On the other hand, the offline one-dimensional Noah-MP LSM simulation captured the site observed pattern and magnitude of radiative fluxes and soil moisture, and it left room for further improvement through supplementing the model input of leaf area index and finding a proper combination of model physics.

Usefulness of Serum Thymidine Kinase 1 as a Biomarker for Aggressive Clinical Behavior in B-cell Lymphoma (B세포림프종의 임상적 악성도 표지자로서 혈청 Thymidine Kinase 1의 유용성)

  • Kim, Heyjin;Kang, Hye Jin;Lee, Jin Kyung;Hong, Young Jun;Hong, Seok-Il;Chang, Yoon Hwan
    • Laboratory Medicine Online
    • /
    • v.6 no.1
    • /
    • pp.25-30
    • /
    • 2016
  • Background: The cell cycle-dependent enzyme thymidine kinase 1 (TK1) is known to increase during cancer cell proliferation and has been reported as a prognostic marker for various hematologic malignancies and solid tumors. This study aimed to determine the reference interval in Korean healthy controls and to evaluate the usefulness of TK1 as a biomarker for aggressive clinical behavior in B-cell lymphoma patients. Methods: We enrolled 72 previously untreated patients with B-cell lymphoma and 143 healthy controls. Serum TK1 levels were measured by chemiluminescence immunoassay ($Liaison^{(R)}$, DiaSorin, USA). We established the reference intervals in healthy controls. The diagnostic performance of serum TK1 was studied using receiver operating characteristic (ROC) analysis, and the correlation between the cutoff level for serum TK1 and clinical characteristics of B-cell lymphoma was evaluated. Results: The reference range (95th percentile) of serum TK1 in healthy controls was 5.4-21.8 U/L. There was a clear difference in TK1 levels between patients with B-cell lymphoma and healthy controls ($40.6{\pm}68.5$ vs. $11.8{\pm}4.4U/L$, P <0.001). The area under the curve of serum TK1 for the diagnosis of B-cell lymphoma was 0.73 (cutoff, 15.2 U/L; sensitivity, 59.7%; specificity, 83.2%). An increased TK1 level (${\geq}15.2U/L$) correlated with the advanced clinical stage (P <0.001), bone marrow involvement (P =0.013), international prognostic index score (P =0.001), lactate dehydrogenase level (P =0.001), low Hb level (<12 g/dL) (P =0.028), and lymphocyte count (P =0.023). Conclusions: The serum TK1 level could serve as a useful biomarker for aggressive clinical behavior in B-cell lymphoma patients.

A New Malting Barley Variety, "Daho" with High Yielding and BaYMV Resistance (맥주보리 호위축병저항성 및 다수성 "다호")

  • Hyun, Jong-Nae;Kim, Mi-Jung;Kim, Yang-Kil;Lee, Mi-Ja;Choi, Jae-Sung;Kim, Hyun-Tae;Han, Sang-Ik;Ko, Jong-Min;Lim, Sea-Gyu;Park, Jong-Chul;Kim, Jung-Gon;Suh, Sae-Jung;Kim, Dae-Ho;Kang, Sung-Ju;Kim, Sung-Taeg
    • Korean Journal of Breeding Science
    • /
    • v.41 no.3
    • /
    • pp.333-337
    • /
    • 2009
  • A new malting barley variety, "Daho", was developed from the cross between "Milyang85 and Suwon335" at the Department of Rice and Winter Cereal Crop (DRWCC) NICS, in 2007. An elite line, YMB2064-B-8-2-4-1-1, was selected in 2004 and designated as "Milyang134". It showed good agronomic performance in the regional adaptation yield trials (RYT) from 2005 to 2007 and was released with the name of "Daho", having high yielding and BaYMV resistance. The average heading and maturing dates of "Daho" were April 19 and May 27, which were 2 days later and 1 day earlier than those of "Jinyang", leading variety, at the regional adaptation yield trials (RYT), respectively. "Daho" had longer culm length (84 cm), more spikes per $m^2$ (915) and higher 1,000 grain weight (39.2 g) than those of "Jinyang" in paddy field condition. "Daho" was showed resistance to BaYMV at the regions of Naju, Jinju, and Milyang but moderately resistance at Iksan. However, the response of "Daho" to other environmental stresses was similar to "Jinyang". The yields of "Daho" at upland and paddy fields were about 5.20 MT/ha, 4.81 MT/ha, respectively, which is about 38%, 25% higher than those of "Jinyang" in the regional adaptation yield trials (RYT), respectively. It has higher grain assortment, germination capacity, water sensitivity and Kolback index but lower malt extract, diastatic power and filtration speed than those of "Jinyang".