A Study on the Development of Testing Models and Its Design System for the Comprehensive Performance Test of the Substation Automation System (변전자동화 종합 성능시험을 위한 시험모델 및 설계시스템 개발에 관한 연구)

  • Lee, Nam-Ho;Jang, Byung-Tae
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.25 no.7
    • /
    • pp.63-71
    • /
    • 2011
  • Due to the rapid development of digital technnology and informantion communication, in the IEC 61850 based substation automation system, the innovative paradigm shift is expected and also required in many substation-related jobs, especially in the device function test area Accordingly a common testing model which can simplify the complex contents of the SAS performance test performed by test engineers has been identified, that can overcome limitations of engineers' own testing knowledge and experience. Testing models and its design system for the comprehensive performance test of the Substation Automation System is developed and the result of the study is reported in this paper.

Proposed Performance Criteria and Evaluation Procedures for Transmission System Planning in Korea

  • Kook, Kyung-Soo;Kim, Taihyun;Oh, Tae-Kyoo;Bang, Min-Jae
    • KIEE International Transactions on Power Engineering
    • /
    • v.2A no.4
    • /
    • pp.160-165
    • /
    • 2002
  • This paper describes a proposed performance criteria and evaluation procedures for transmission system planning in Korea. Performance criteria of the transmission system are expected to be used as a guideline for investment into a transmission network. Moreover, performance evaluation procedures, which are based on current practices and widely accepted theories, are suggested to achieve fair and acceptable results.

Performance Testing of Composite Web-Service with Aspect-Based WS-BPEL Extension

  • Kim, Jong-Phil;Sung, Dong-Hyuk;Hong, Jang-Eui
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.5 no.10
    • /
    • pp.1841-1861
    • /
    • 2011
  • The advance in Service-Oriented Architecture (SOA) and web services has led to the development of new types of a system in which heterogeneous service components can connect and compose to solve a complex business problem. In the SOA, even though these service components are valid in their functionality, there is a need to test their behaviors when those services are composited. In recent years, WS-BPEL has received a wide acceptance as a means of integrating distributed service components. To test the composite service, the existing testing techniques have been focused on the functional features based on the WS-BPEL process. However as SOA approach is applying to real-time software development, the performance of composite service becomes one of important issues. This paper proposes a technique to the performance testing of a composite service with WS-BPEL extension which combined with the concept of aspect. Our WS-BPEL extension has been made towards annotating aspect component which is measuring the response time of the composite service. This paper also explains the procedure of performance testing with on-line transaction system. Our technique can apply to choose an adequate component in service composition with considering the performance among several candidate web service components.

A Study on the Curving Performance of a Scaled Bogie on a Scaled Curve Track (축소 곡선 트랙상에서의 축소 대차 곡선주행특성 연구)

  • Hur, Hyun-Moo;Park, Joon-Hyuk;You, Won-Hee;Park, Tae-Won
    • Journal of the Korean Society for Railway
    • /
    • v.10 no.5
    • /
    • pp.613-618
    • /
    • 2007
  • The performance of the railway bogie is classified into the stability and the steering performance. Testing for the bogie stability is conducted on the roller rig, but testing for the bogie steering performance on test facility is very difficult, so the testing for the vehicle curving performance is conducted on the real curve track. Testing the railway bogie on the full scale test rig is desirable, but it caused many problems relating to test costs and test time. As a possible alternative to overcome these problems, a small scaled test rig is actively used in the field of bogie stability. Thus, in this paper, we have studied a scaled track to test the bogie steering performance. For this purpose, we designed the 1/5 scaled test track equivalent to radius 200 curve and confirmed the validity of the testing for the bogie steering performance on the sealed curve track through the testing using 1/5 scaled bogie.

Durability and Performance Requirements in Canadian Cement and Concrete Standards (캐나다 시멘트 및 콘크리트의 내구성 및 제성능에 대한 규준)

  • Hooton, R.D.
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2006.05a
    • /
    • pp.5-21
    • /
    • 2006
  • Traditional standards and specifications for concrete have largely been prescriptive, (or prescription-based), and can sometimes hinder innovation and in particular the use of more environmentally friendly concretes by requiring minimum cement contents and SCM replacement levels. In December 2004, the Canadian CSA A23.1-04 standard was issued which made provisions (a) for high-volume SCM concretes, (b) added new performance requirements for concrete, and (c) clearly outlined the requirements and responsibilities for use in performance-based concrete specifications. Also, in December 2003, the CSA A3000 Hydraulic Cement standard was revised. It (a) reclassified the types of cements based on performance requirements, with both Portland and blended cements meeting the same physical requirements, (b) allows the use of performance testing for assessing sulphate resistance of cementitious materials combinations, (c) includes an Annex D, which allows performance testing of new or non-traditional supplementary cementing materials. From a review of international concrete standards, it was found that one of the main concerns with performance specifications has been the lack of tests, or lack of confidence in existing tests, for judging all relevant performance concerns. Of currently used or available test methods for both fresh, hardened physical, and durability properties, it was found that although there may be no ideal testing solutions, there are a number of practical and useful tests available. Some of these were adopted in CSA A23.1-04, and it is likely that new performance tests will be added in future revisions. Other concerns with performance standards are the different perspectives on the point of testing for performance. Some concrete suppliers may prefer processes for both pre-qualifying the plant, and specific mixtures, followed only with testing only 'end-of-chute' fresh properties on-site. However, owners want to know the in-place performance of the concrete, especially with high-volume SCM concretes where placing and curing are important. Also, the contractor must be aware of, and share the responsibility for handling, constructability, curing, and scheduling issues that influence the in-place concrete properties.

  • PDF

An Estimation of Performance Test and Uncertainty of Measurement for a Large Axial-flow Fan Based on ANSI/AMCA 210 Standard (ANSI/AMCA 210 기준에 의한 대형 축류 송풍기의 성능시험 및 측정 불확도 평가)

  • Ko, Hee-Hwan;Chung, Cheol-Young;Kim, Kyung-Yup
    • The KSFM Journal of Fluid Machinery
    • /
    • v.17 no.2
    • /
    • pp.24-29
    • /
    • 2014
  • In general, a large-capacity axial flow fan is used for industrial processes or ventilation in a social overhead capital infrastructure. The main characteristics of the large axial-flow fan need a lot of electrical power consumption and operate 24 hours a day, 365 days a year. Since the large axial flow fan consumes several hundreds to thousands kW per hour, both manufacturer and consumer are struggling to select high efficiency products for saving energy and reducing operation cost. Therefore, the performance testing should be accurately conducted in experimental equipments. The performance estimation and uncertainty of measurement of the axial-flow fan gathered from the result from nozzle shaped testing equipments certified with ANSI/AMCA standard and duct shaped testing equipment under the same experimental condition. The experimental results from both facilities have maximum 17% differences in performance evaluation and uncertainty of measurement. As considering that the differences, it is doubt about the reliability of testing result. The test was repeated with the specific term during 12 months because it is important to fully reflect the real conditions and to decide the repeatability of data. The evaluation of duct type testing facilities was failed to get an uncertainty measure. Testing results were previously published. As a series of previous paper, axial fan (∅1690 mm) and duct type testing facilities were fabricated. The purpose of fabricating testing equipment was testing an uncertainty measurement under the controlled environments.

Analysis of Spin Valve Tunneling Magnetoresistance Sensor for Eddy Current Nondestructive Testing

  • Kim, Dong-Young;Yoon, Seok-Soo;Lee, Sang-Hun
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.28 no.6
    • /
    • pp.524-530
    • /
    • 2008
  • The spin valve tunneling magnetoresistance (SV-TMR) sensor performance is analyzed using Stoner-Wohlfarth model for the detection of eddy current signals in nondestructive testing applications. The SV-TMR response in terms of the applied AC magnetic field dominantly generates the second harmonic amplitude in hard axis direction. The second harmonic eddy current signal detection using SV-TMR sensor shows higher performance than that of the coil sensor at lower frequencies. The SV-TMR sensor with high sensitivity gives a good solution to improve the low frequency performance in comparison with the inductive coil sensors. Therefore, the low frequency eddy current techniques based on SV-TMR sensors are specially useful in the detection of hidden defects, and it can be applied to detect the deeply embedded flaws or discontinuities in the conductive materials.

A Methodology for Performance Testing of Ethernet Switch (Layer 3 이더넷 스위치 성능 시험 방법론 연구)

  • 김용선
    • Proceedings of the IEEK Conference
    • /
    • 2000.11a
    • /
    • pp.441-444
    • /
    • 2000
  • This paper covers the performance testing for layer 3 Ethernet switch based on various methodologies by which we can measure essential metrics such as throughput, latency, frame loss rate, and back to back frames. In the first place, layer 2 and layer 3 switch evolution is introduced followed by description of IP packet switching in layer 3 switch. And then, the above test metrics and test methodologies are illustrated as well. At last, we conduct the performance testing for layer 3 switch in case of transmitting packets of 64, 128, 256, 512, 1024, 1280, and 1518 byte size and analyze then results.

  • PDF

Durability Performance Evaluation of an Aluminum Knuckle using Virtual Testing Method (가상시험법을 이용한 알루미늄 너클의 내구수명 평가)

  • Ko, Han-Young;Choi, Gyoo-Jae
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.18 no.1
    • /
    • pp.44-50
    • /
    • 2010
  • Durability performance evaluation technology using Virtual Testing Method is a new concept of a vehicle design, which can reduce the automotive components design period and cost. In this paper, the fatigue life of an aluminum knuckle of a passenger car is evaluated using virtual testing method. The flexible multibody dynamic model of a front half car module is generated and solved with service loads which are measured from Belgian roads. Using a multibody dynamic analysis software, the flexible multibody dynamic simulation of a half car model is carried out and the dynamic stress profile of an aluminum knuckle is acquired. The stress profile is exported to a fatigue analysis software and durability performance of an aluminum knuckle is evaluated.

An Experimental Study on the Performance Testing of Parallel Expansion Refrigeration System (병렬팽창 냉동시스템의 성능실험에 관한 실험적 연구)

  • Koo, Chang-Dae
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.14 no.2
    • /
    • pp.79-85
    • /
    • 2011
  • This study has been experimented about refrigeration capacity difference. It has been used 3 method, Manual expansion valve, thermostatic expansion valve and capillary expansion valve, and tested under the same condition by using the performance testing of parallel expansion. In temperature change of the temperature room, thermostatic expansion valve method displayed the most lower temperature, $-18^{\circ}C$. In addition, the temperature, just before the expansion, also displayed the best result which was $4^{\circ}C$ lower than other expansion valve. In these results, it can be used for performance testing of parallel expansion refrigeration system.