• 제목/요약/키워드: Performance of fuel cell

검색결과 1,395건 처리시간 0.028초

유한요소법을 이용한 고분자전해질연료전지 기체확산층의 응력분포 연구 (The Stress Distribution Analysis of PEMFC GDL using FEM)

  • 김철현;손영준;박구곤;김민진;이종욱;김창수;최유송;조성백
    • 한국수소및신에너지학회논문집
    • /
    • 제23권5호
    • /
    • pp.468-475
    • /
    • 2012
  • A proper stacking force and assembly are important to the performance of fuel cell. Improper assembly pressure may lead to leakage of fuels and high interfacial contact resistance, excessive assembly pressure may result in damage to the gas diffusion layer and other components. The pressure distribution of gas diffusion layer is important to make interfacial contact resistance less for stack performance. To analyze the influence of design parameter factors for pressure distribution, and to optimize stack design, DOE (Design of Experiment) was used for polymer electrolyte membrane fuel cell stack pressure test. As commonly known, the higher clamping force improves the fuel cell stack performance. However, non-uniformity of stress distribution is also increased. It shows that optimization between clamping force and stress distribution is needed for well designed structure of fuel cell stack. In this study, stack design optimization method is suggested by using FEM (Finite Element Methode) and DOE for light-weighted fuel cell stack.

직접 메탄올 연료전지의 이층막 전극 개발 (Development of Two-layer Electrode for Direct Methanol Fuel Cell)

  • 정두환;홍성화;백동현;송락현;신동열;김혁년
    • 전기화학회지
    • /
    • 제6권1호
    • /
    • pp.68-71
    • /
    • 2003
  • 전지 성능을 저하시키지 않고 연료극 및 공기극의 귀금속 촉매량을 줄이기 위하여 다층막 전극을 이용한 직접메탄을 연료전지의 성능특성을 조사하였다. 다층막 전극 즉, 연료극과 공기극에 사용된 촉매사용량과 나피온 막의 종류를 변화시키며 최종성능을 측정하였다 본 실험에서 사용된 촉매량은 연료극이 $3-4mg/cm^2$ 공기극이 $1-2mg/cm^2$이다. 본 실험에서는 나피온 115를 사용한 MEA3의 $90^{\circ}C$, 2기압에서 측정 결과 최대 전력밀도인 $230mW/cm^2$를 나타내었다. 이 결과는 현재 시판되고 있는 상용전극과 거의 같은 수준의 성능을 보여주고 있는 반면, 금속 촉매의 양은 기존의 상용전극과 비교하여 약 $50\%$ 정도 감소된 것이다.

직접 수소화붕소나트륨/과산화수소 연료전지를 위한 니켈 기반 촉매 (Nickel-Based Catalysts for Direct Borohydride/Hydrogen Peroxide Fuel Cell)

  • 오택현
    • 한국수소및신에너지학회논문집
    • /
    • 제31권6호
    • /
    • pp.587-595
    • /
    • 2020
  • Nickel-based bimetallic catalysts were investigated for use in direct borohydride/hydrogen peroxide fuel cells. For anode and cathode, PdNi and AuNi catalysts were used, respectively. Nickel-based bimetallic catalysts have been investigated through various methods, such as inductively coupled plasma optical emission spectroscopy, transmission electron microscopy, scanning electron microscopy, and energy dispersive spectroscopy. The performance of the catalysts was evaluated through fuel cell tests. The maximum power density of the fuel cell with nickel-based bimetallic catalysts was found to be higher than that of the fuel cell with the monometallic catalysts. The nickel-based bimetallic catalysts also exhibited a stable performance up to 60 minutes.

대형 Community 건물의 연료전지 구동 복합열원 하이브리드 히트펌프 냉.난방 시스템 성능 해석 (The Study on the Performance of the Fuel Cell Driven Compound Source Hybrid Heat Pump Heating and Cooling System to Large Community Building)

  • 변재기;정동화;최영돈
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2007년도 동계학술발표대회 논문집
    • /
    • pp.82-87
    • /
    • 2007
  • In the present study, the simulation on the annual performance evaluation of a renewable energy systems with fuel cell driven compound source hybrid heat pump systems is applied to the heating and cooling of large community building. The large community building has the economical advantage to apply heat pump cooling and heating systems the long period operation. If air and ground source hybrid heat pump systems are combined, COP of the system can be increased largely. Fuel cell driven compound source hybrid heat pump system can reduced the fuel cost as well as thermal storage tank sharply.

  • PDF

임피던스법을 적용한 연료전지 성능규명 (Fuel Cell Performance by the Impedance Method)

  • 김귀열;서장수;박용필;이준응
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2001년도 추계학술대회 논문집
    • /
    • pp.157-159
    • /
    • 2001
  • The molten carbonate fuel cell has conspicuous feature and high potential in being used as an energy converter of various fuel to electricity and heat. However, the MCFC which use strongly corrosive molten carbonate at 650$^{\circ}C$ have many problem. Systematic investigation on corrosion behavior of Fe/20Cr/Ti alloys has been done in (62+38)mol% (Li+K)CO$_3$ melt at 923K by using steady state polarization and electrochemical impedance spectroscopy method. And, The research and development for the solid oxide fuel cell have been promoted rapidly and extensively in recent years, because of their high efficiency and future potential. Therefore this paper describes the manufacturing method and characteristics of anode electrode for SOFC, by the way, Ni-YSZ materials are used as anode of SOFC widely. So in this experiments, we investigated the optimum content of Ni, by the impedance characteristics, overvoltage. As a result, the performance of Ni-YSZ anode(47vo1%) was bettor excellent than the others.

  • PDF

연료중의 이산화탄소 불순물에 의한 연료전지 성능변화 연구 (Effect of Carbon dioxide in Fuel on the Performance of PEM Fuel Cell)

  • 서중근;권준택;김준범
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2007년도 추계학술대회 논문집
    • /
    • pp.184-187
    • /
    • 2007
  • Hydrogen could be produced from any substance containing hydrogen atoms, such as water, hydrocarbon (HC) fuels, acids or bases. Hydrocarbon fuels couold be converted to hydrogen-rich gas through reforming process for hydrogen production. Even though fuel cell have high efficiency with pure hydrogen from gas tank, it is more beneficial to generate hydrogen from city gas (mainly methane) in residential application such as domestic or office environments. Thus hydrogen is generated by reforming process using hydrocarbon. Unfortunately, the reforming process for hydrogen production is accompanied with unavoidable impurities. Impurities such as CO, $CO_2$, $H_2S$, $NH_3$, and $CH_4$ in hydrogen could cause negative effects on fuel cell performance. Those effects are kinetic losses due to poisoning of electrode catalysts, ohmic losses due to proton conductivity reduction including membrane and catalyst ionomer layers, and mass transport losses due to degrading catalyst layer structure and hydrophobic property. Hydrogen produced from reformer eventually contains around 73% of $H_2$, 20% or less of $CO_2$, 5.8% of less of $N_2$, or 2% less of $CH_4$, and 10ppm or less of CO. Most impurities are removed using pressure swing adsorption (PSA) process to get high purity hydrogen. However, high purity hydrogen production requires high operation cost of reforming process. The effect of carbon dioxide on fuel cell performance was investigated in this experiment. The performance of PEM fuel cell was investigated using current vs. potential experiment, long run (10 hr) test, and electrochemical impedance measurement when the concentrations of carbon dioxide were 10%, 20% and 30%. Also, the concentration of impurity supplied to the fuel cell was verified by gas chromatography (GC).

  • PDF

건물용 고분자 전해질 연료전지 금속분리판 유동장 형상 변화에 따른 산소 확산 특성에 대한 연구 (A Study on Oxygen Diffusion Characteristics According to Changes in Flow Field Shape of Polymer Electrolyte Membrane Fuel Cell Metallic Bipolar Plate for Building)

  • 박동환;손영준;최윤영;김민진;홍종섭
    • 한국수소및신에너지학회논문집
    • /
    • 제32권4호
    • /
    • pp.245-255
    • /
    • 2021
  • Various studies about metallic bipolar plates have been conducted to improve fuel cell performance through flow field design optimization. These research works have been mainly focused on fuel cells for vehicle, but not fuel cells for building. In order to reduce the price and volume of fuel cell stacks for building, it is necessary to apply a metallic flow field, In this study, for a metallic flow field applied to a fuel cell for building, the effect of a change in the flow field shape on the performance of a polymer electrolyte membrane fuel cell was confirmed using a model and experiments with a down-sizing single cell. As a result, the flow field using a metal foam outperforms the channel type flow field because it has higher internal differential pressure and higher reactants velocity in gas diffusion layer, resulting in higher water removal and higher oxygen concentration in the catalyst layer than the channel type flow field. This study is expected to contribute to providing basic data for selecting the optimal flow field for the full stack of polymer electrolyte membrane fuel cells for buildings.

연료전지 자동차 열방출 시스템의 설계 (Design of a Heat Release System for Fuel Cell Vehicles)

  • 김성철;박민수;정승훈;윤석호;김민수
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2005년도 제17회 워크샵 및 추계학술대회
    • /
    • pp.545-548
    • /
    • 2005
  • There is a close relation between the heat generation in the fuel cell stack and the fuel cell performance. In PEM fuel Gell vehicles, the stack coolant temperature is about $65^{\circ}C$, which is far lower than that for general automobile engine. Therefore, it is hard to release heat generated in the stack by using a radiator of limited size because of the reduced temperature difference between the coolant and the ambient air. In this study, indirect stack cooling system using $CO_2$ heat pump was designed and its stack cooling performance in releasing heat to the ambient was investigated. This work focuses on a series of processes that grasp the relation among the fuel cell power, the radiator capacity and the stack temperature. The purpose of this work is to find out a way to properly release sufficient amount of heat through the finite sized radiator, so that the stack power general ion can not be deteriorated due to the stack temperature increase. The optimization between the compressor power consumption and the fuel cel1 output power can be carried out to maximize the performance of fuel cell system.

  • PDF

고온 고분자전해질 연료전지 박판형 분리판의 유로 설계 및 스택 성능 평가 (Flow Field Design and Stack Performance Evaluation of the Thin Plate Separator for High Temperature Polymer Electrolyte Membrane Fuel Cell)

  • 김지홍;김민진;김진수
    • 한국수소및신에너지학회논문집
    • /
    • 제29권5호
    • /
    • pp.442-449
    • /
    • 2018
  • Research on High temperature polymer electrolyte fuel cell (HT-PEMFC) has actively been conducted all over the world. Since the HT-PEMFC can be operated at a high temperature of $120-180^{\circ}C$ using phosphoric acid-doped polybenzimidazole (PBI) electrolyte membrane, it has considerable advantages over conventional PEMFC in terms of operating conditions and system efficiency. However, If the thermal distribution is not uniform in the stack unit, degradation due to local reaction and deterioration of lifetime are difficult to prevent. The thin plate separator reduces the volume of the fuel cell stack and improves heat transfer, consequently, enhancing the cooling effect. In this paper, a large area flow field of thin plate separator for HT-PEMFC is designed and sub-stack is fabricated. We have studied stack performance evaluation under various operating conditions and it has been verified that the proposed design can achieve acceptable stack performance at a wide operating range.

상대습도 변화에 따른 PEM Fuel Cell 내에서의 플러딩에 관한 실험적 연구 (Experimental studies on Flooding in the PEM Fuel Cell at various RH)

  • 김경록;한성호;안득균;최영돈
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2008년도 추계학술대회B
    • /
    • pp.2385-2389
    • /
    • 2008
  • This is the experimental research that tries to explain a variety of RH is how to affect the cell performance and the flooding phenomenon of proton exchange membrane fuel cell (PEMFC). A value of PH changes to 0%, 50% and 90% as its variation, either stoichiometric flow rate changes to 1.5, 2 and 4. Into the comparison between theoretical and experimental value, this study analyzes that a variety of PH is how 10 affect flooding in the cathode of the proton exchange membrane fuel cell. The effect of air stoichiometry, air humidity and different flow fields are also discussed in this paper This study has accomplished the measurement of performance as the variety of RH in the cathode of proton exchange membrane fuel cell, moreover it has recorded the visualization of flooding in the cathode with a high-speed micro camera.

  • PDF