• Title/Summary/Keyword: Performance isolation

Search Result 1,070, Processing Time 0.027 seconds

Development of a battery management system(BMS) simulator for electric vehicle(EV) cars (EV용 배터리 관리시스템(BMS) 시뮬레이터 개발)

  • Park, Chan-Hee;Kim, Sang-Jung;Hwang, Ho-Suk;Lee, Hee-Gwan
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.13 no.6
    • /
    • pp.2484-2490
    • /
    • 2012
  • This study reports on the development and performance verification of cell simulation boards of simulator and the embedded program for board control of the battery management system (BMS) of electric vehicle (EV) cars, which manages the next-generation automotive lithium-ion battery pack. Here, we have improved the speed of the simulator by using operational (OP) amplifier and transistors that were connected in series. In addition, using a digital analog converter (DAC) in each channel, we have improved the performance by channel-to-channel isolation (isolation) as compared to the traditional methods. Furthermore, by constructing a current-limiting protection circuit, one can be protected from disturbance and, by utilizing a precision shunt resistor for the current sensor, we have increased the precision of the current control. In order to verify the performance of the developed simulator, we have performed the experiment 10 times, with values ranging from 0.5 V to 5 V, and a voltage drop step of 0.5 V. Significance analysis of experimental data, and repeatability tests were performed, showing an average standard deviation of 0.001~0.004 V, indicating high repeatability and high statistical significance of the current method and system.

An Experimental Study on the Capability of Arresting the Spread of a Fire of Fireproof Fabric Equipped over Ceiling Board of Wooden Cultural Properties (목조문화재 개판 상부에 설치하는 방염천의 화재전파 차단기능에 대한 실험연구)

  • Kim, Hyunju;Roh, Sam-Kew;Kim, Dong Cheol;Ham, Eun-Gu
    • Journal of the Society of Disaster Information
    • /
    • v.8 no.3
    • /
    • pp.297-303
    • /
    • 2012
  • This study examines the isolation-heat performance of fire proof fabric that is equipped over ceiling board in order to secure the capability of arresting the spread of a fire at roof 'Jucsim' structure of Wooden Cultural Properties. For this examination, I conduct experiments with the model and compare two construction methods of fire proof fabric, or flat-type, folding-type. The experiments show the following results. In case of installing the fire proof fabric in flat-type, when the temperature under the ceiling board is $750^{\circ}C$, the temperatures over the ceiling board is $50^{\circ}C$; the difference is $700^{\circ}C$. Compared with the case of removing fire proof fabric, the temperature over the ceiling board is lower by approximately $580^{\circ}C{\sim}600^{\circ}C$. Therefore it can be said that the construction of fire proof fabric enhances the isolation-heat performance. In case of installing the fire proof fabric in folding-type, when the temperature under the ceiling board is $600^{\circ}C$, the temperatures over the ceiling board is $65^{\circ}C$; the difference is approximately $530^{\circ}C$. Thus its isolation-heat performance is a little inferior to the flat-type equipment.

A Analytical Study on Seismic Performance of Stainless Water Tank using Lead Rubber Bearing (납고무받침을 이용한 스테인리스 물탱크 내진성능에 관한 해석적 연구)

  • Kim, Hu-Seung;Oh, Ju;Jung, Hie-Young
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.11
    • /
    • pp.230-236
    • /
    • 2018
  • Earthquakes over 5.0 on the Richter scale have recently occurred in Korea, which has led to interest in the seismic safety of structures. If a water storage facility is damaged by an earthquake, the water could leak, and the insufficient water would make fire suppression difficult. Therefore, a water storage facility should satisfy safety requirements for earthquakes. In this study, the seismic performance of a water tank was improved by installing a lead rubber bearing between the foundation and the tank. It designed the lead rubber bearing available to the existed concrete foundation. ANSYS was used for modeling to consider the interaction between the fluid and structure of the tank and the hydrostatic and hydrodynamic pressure using four seismic waves. In the case of hydrostatic pressure at 2.5 water level, full level, the same stress appeared irrespective of whether the seismic isolation was installed. When hydrostatic pressure and hydrodynamic pressures are applied at the same time, the seismic-isolated water tank showed less seismic force, and the damping ratio was lower than that of general seismic isolation. This occurred because the weight of the water tank is much smaller than the stiffness of the seismic isolation. The result is expected to be used for further research on seismic capacity evaluation for water tanks.

Unequal Power Divider based on Adjustment Electrical Length of Uniform Transmission Line (단일 전송선로의 전기적 길이 조정을 이용한 비대칭 분배기)

  • Kwon, Sang-Keun;Kim, Young
    • Journal of Advanced Navigation Technology
    • /
    • v.22 no.6
    • /
    • pp.642-647
    • /
    • 2018
  • In this paper, an unequal power divider based on adjusting electrical length of uniform transmission line is presented. This divider consists of three uniform transmission lines and one isolation resistor and have the different port impedances of input and output. The feature of proposed divider can changed the power dividing ratio to adjust only electrical length of uniform transmission lines. To verify the feasibility of proposed power divider, two divider circuits are designed, one is 1:2 power dividing ratio divider with $60{\Omega}$ uniform transmission line and $40{\Omega}$ input port impedances and $45{\Omega}$ output port impedances, the performance data were measured the insertion losses of 1.7 dB/ 5.0 dB, return losses of more than -30 dB and isolation of more than -35 dB. The other is 1:4 power dividing ratio divider with $40{\Omega}$ uniform transmission line and $50{\Omega}$ input port impedances and $75{\Omega}$ output port impedances, the performance data were measured the insertion losses of 1.3 dB/ 6.8 dB, return losses of more than -12 dB and isolation of more than -19 dB. The measured performance data agreed well with the simulated results.

Emergency Nurses' Perception and Performance of Tuberculosis Infection Control Measures (응급실 간호사의 결핵감염관리에 대한 인식과 수행)

  • Kim, Soo-Jung;Kang, Ji-Yeon
    • Journal of Korean Academy of Fundamentals of Nursing
    • /
    • v.17 no.3
    • /
    • pp.351-361
    • /
    • 2010
  • Purpose: The purpose of this study was to investigate the perception and performance of tuberculosis infection control measures among emergency department nurses. Methods: A structured questionnaire was administered to a convenience sample of 227 emergency department nurses from 20 hospitals in B City. Results: The mean perception score was 4.52 out of a possible 5, and the mean performance score was 3.31 out of a possible 5. There were big differences between the perception and performance score on the items regarding wearing a gown or mask, while there were small differences on the items regarding dealing with patients' articles or medication. Conclusion: Emergency nurses showed high perception and low performance score on the items related to facilities and regulation such as visitation restriction or patient isolation. There was a positive correlation between perception and performance score. Conclusion: For emergency nurses, perception is higher than performance of tuberculosis infection control measures. The findings indicate the importance of providing continuing education for emergency nurse professionals seeking to update and increase their knowledge and to develop evidence-based nursing protocols on tuberculosis infection control in emergency department.

A Performance Consideration on Conversion Loss in the Integrated Single Balanced Diode Mixer

  • Han, Sok-Kyun;Kim, Kab-Ki
    • Journal of information and communication convergence engineering
    • /
    • v.1 no.3
    • /
    • pp.139-142
    • /
    • 2003
  • In this paper, we consider the factors that affect a conversion loss performance in designing a single balanced diode mixer integrated with IRF(Image Reject Filter), based on the embedded electrical wavelength placed between the IRF and mixer, diode matching and LO drive amplifier. To evaluate the conversion loss performance, we suggest two types of a single balanced mixer using 90 degree branch line coupler, microstrip line and schottky diode. One is only mixer and the other is integrated with IRF and LO drive amplifier. The measured results of a single balance diode mixer integrated IRF show the conversion loss of 8.5 dB and the flatness of 1 dB p-p from 21.2 GHz to 22.6 GHz with 10 dBm LO. The measured input PI dB and IIP3 are 7 dBm and 15 dBm respectively under the nominal LO power level of 10dBm. The LO/RF and LO/IF isolation are 22 dB and 50 dB, respectively.

The Study on Improvement of Acoustic Performance for Automobile Sound-absorbing Materials Using Hollow Fiber (중공 섬유를 이용한 자동차 흡음재 성능 향상 연구)

  • Lee, Jung-Wook;Lee, Su-Nam;Shim, Jae-Hyun;Jung, Pan-Ki;Lee, Won-Ku;Bang, Byoung-Joo
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.21 no.9
    • /
    • pp.850-857
    • /
    • 2011
  • Generally, sound-absorbing materials in vehicles are used for giving the comfort to passengers by reducing noise while driving. Materials of which targets are light weight, high performance, eco friendliness and recycling have been developed recently. In this study, sound-absorbing materials using PET(polyethylene terephthalate) hollow fibers to achieve the light weight and the high sound absorption performance are developed, and then evaluated to meet a requirement for the automotive components. The test results show that the acoustic performances of developed products having new fiber structure are better than those of the conventional product.

Seismic retrofitting of a tower with shear wall in UHPC based dune sand

  • Trabelsi, Abderraouf;Kammoun, Zied;Beddey, Aouicha
    • Earthquakes and Structures
    • /
    • v.12 no.6
    • /
    • pp.591-601
    • /
    • 2017
  • To prevent or limit the damage caused by earthquakes on existing buildings, several retrofitting techniques are possible. In this work, an ultra high performance concrete based on sand dune has been formulated for use in the reinforcement of a multifunctional tower in the city of Skikda in Algeria. Tests on the formulated ultra high performance concrete are performed to determine its characteristics. A nonlinear dynamic analysis, based on the "Pushover" method was conducted. The analysis allowed an optimization of the width of reinforced concrete walls used in seismic strengthening. Two types of concrete are studied, the ordinary concrete and the ultra high performance concrete. Both alternatives are compared with the reinforcement with carbon fibers and by base isolation retrofit design.

Characteristics of Lateral Structure Transistor (횡방향 구조 트랜지스터의 특성)

  • 이정환;서희돈
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.13 no.12
    • /
    • pp.977-982
    • /
    • 2000
  • Conventional transistors which have vertical structure show increased parasitic capacitance characteristics in accordance with the increase of non-active base area and collector area. These consequently have disadvantage for high speed switching performance. In this paper, a lateral structure transistor which has minimized parasitic capacitance by using SDB(Silicon Direct Bonding) wafer and oxide sidewall isolation utilizing silicon trench technology is presented. Its structural characteristics are designed by ATHENA(SUPREM4), the process simulator from SILVACO International, and its performance is proven by ATLAS, the device simulator from SILVACO International. The performance of the proposed lateral structure transistor is certified through the V$\_$CE/-I$\_$C/ characteristics curve, h$\_$FE/-I$\_$C/ characteristics, and GP-plot. Cutoff Frequency is 13.7㎓.

  • PDF

Analysis of IEC 61727 Photovoltaic (PV) systems Characteristics of the utility interface

  • Lee, Jeong Hyeon;Yoon, Yong Ho;Kim, Jae Moon
    • International Journal of Internet, Broadcasting and Communication
    • /
    • v.7 no.2
    • /
    • pp.90-95
    • /
    • 2015
  • This paper describes IEC 61727 standard of Photovoltaic (PV) systems -Characteristics of the utility interface. IEC 61727 standard tests include utility compatibility and personnel safety and equipment protection of PV inverter performance functions. Especially utility compatibility part includes test items of 1) voltage, current and frequency, 2) normal voltage operating range, 3) flicker, 4) DC injection, 5) normal frequency operating range, 6) harmonics and 7) waveform distortion, 8) power factor of PV inverter. Also personnel safety and equipment protection part includes test items 1)loss of utility voltage, 2)over/under voltage and frequency, 3)Islanding protection, 4)response to utility recovery, 5)earthing, 6)short circuit protection, 7)Isolation and switching of PV inverter. In this paper, each item of IEC 61727 standard test is studied and analyzed and finally full tested by PV inverter performance function.