• Title/Summary/Keyword: Performance isolation

Search Result 1,070, Processing Time 0.032 seconds

Modular Photovoltaic PCS with High-frequency Isolation (고주파 절연 모듈형 Photovoltaic PCS)

  • Kwon, Jung-Min;Kwon, Bong-Hwan
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2005.06a
    • /
    • pp.132-135
    • /
    • 2005
  • A modular photovoltaic PCS with high-frequency isolation is proposed. The proposed system consists of a SEPIC converter and a full-bridge inverter. Using the power slope versus voltage of the PV array, the MPPT controller is proposed that produces a smooth transition to the maximum power point. The disturbance of the line voltage is detected using a fast sensing technique. Experimental results obtained on a 500W prototype show high performance such as almost unity power factor, $90\%$ power efficiency, $3.6\%$ THD.

  • PDF

Theoretical Overview of Membrane Transport (막물질 이동의 이론적 고찰)

  • Park, Young
    • Membrane Journal
    • /
    • v.3 no.3
    • /
    • pp.94-107
    • /
    • 1993
  • Many researchers have discussed how membrane performance can be enhanced through an understanding of polymer science and engineering. The understandings of transport in porous membrane are used to achieve the isolation of certain components from mixtures. Particular emphasis is placed on the applicability of membrane separations for the isolation of macromolecules[1]. An awareness of membrane structure characteristics is required for the rational design of membranes for specific and/or new applications. This understanding rests on the knowledge of fields such as polymer thermodynamics[2], polymer adsorption [3, 4], diffusion in polymers[5, 6], reaction mechanism[7], and the dynamic behavior[8, 9] of polymer in porous membrane.

  • PDF

Field-Dependent Characteristics of ER Shock Damper (ER 유체를 이용한 충격절연 댐퍼의 특성 연구)

  • 송현정;최승복;김재환;김경수
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2001.05a
    • /
    • pp.109-114
    • /
    • 2001
  • This paper presents field-dependent dynamic characteristics of a shock damper featuring an electro-rheological(ER) damper. A cylindrical type of the shock damper is designed and manufactured on the basis of the field-dependent Bingham model. The damping force is then measured with respect to the piston velocity at various electric fields. The measured damping force is incorporated with the 1DOF shock system to analyze the shock isolation performance.

  • PDF

Experimental Evaluation of Seismic Performance for Seismic Isolation Bearings (지진격리장치의 내진성능에 관한 실험적 평가)

  • Oh, Ju;Lee, Jae-Uk;Lim, Hyung-Ju;Kim, Hyung-Oh
    • Proceedings of the KSR Conference
    • /
    • 2010.06a
    • /
    • pp.1126-1131
    • /
    • 2010
  • Experimental studies for the high damping rubber bearing, lead rubber bearing and natural rubber bearing, those are often used to improve the seismic capacity if the structure recently, are conducted to evaluate the seismic capacity of the seismic isolation bearings. The shear stiffness of the bearings decrease and the shear strain amplitude or the constant axial load level increase, but not sensitive to the strain rate effect. Bearings are strong for the axial compression but weak for the axial tension.

  • PDF

Aseismic Effectiveness of LR type Base Isolated System (LR형 지반분리계의 내진효과)

  • 정연경;예광일;김재웅
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 1997.10a
    • /
    • pp.231-238
    • /
    • 1997
  • Many methods have been proposed for achieving optimum performance of structures subjected to earthquake excitation. The conventional approach requires that structures passively resist earthquakes through a combination of strength, deformability, and energy absorption. Base isolation is a technique for mitigating the effects of earthquakes on structures through the introduction of flexibility and energy absorption capability. In this paper, a parametric study of effectiveness of isolation systems with various main structures' properties is carried out through the response spectrum analysis. It is shown that, most base isolators with its longer period and higher damping can significantly reduce the base shear force transmitted to the structures.

  • PDF

Thermal Design of Cryogenic Compressor with Strategies for Keeping Performance of Micro-vibration Isolation System (미소진동저감용 진동절연기의 성능유지를 위한 극저온 냉각용 압축기 조립체 열제어 설계)

  • Oh, Hyun-Ung;Lee, Kyung-Joo;Jeong, Suk-Yong;Shin, So-Min
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.40 no.3
    • /
    • pp.237-242
    • /
    • 2012
  • Spaceborne pulse tube-type cryogenic compressors are widely used for space applications. To guarantee cooling performance of the compressor, mission life time and micor-vibration stability, suitable thermal control of compressor is required. Micro-vibration of the compressor is the one of the sources to degrade the pointing performance of observation satellite. In the present work, on-orbit thermal design of compressor in order not to degrade the performance of micro-vibration isolation system keeping the thermal control performance has been proposed and investigated through thermo-mechanical analysis.

Vibration isolation with smart fluid dampers: a benchmarking study

  • Batterbee, D.C.;Sims, N.D.
    • Smart Structures and Systems
    • /
    • v.1 no.3
    • /
    • pp.235-256
    • /
    • 2005
  • The non-linear behaviour of electrorheological (ER) and magnetorheological (MR) dampers makes it difficult to design effective control strategies, and as a consequence a wide range of control systems have been proposed in the literature. These previous studies have not always compared the performance to equivalent passive systems, alternative control designs, or idealised active systems. As a result it is often impossible to compare the performance of different smart damper control strategies. This article provides some insight into the relative performance of two MR damper control strategies: on/off control and feedback linearisation. The performance of both strategies is benchmarked against ideal passive, semi-active and fully active damping. The study relies upon a previously developed model of an MR damper, which in this work is validated experimentally under closed-loop conditions with a broadband mechanical excitation. Two vibration isolation case studies are investigated: a single-degree-of-freedom mass-isolator, and a two-degree-of-freedom system that represents a vehicle suspension system. In both cases, a variety of broadband mechanical excitations are used and the results analysed in the frequency domain. It is shown that although on/off control is more straightforward to implement, its performance is worse than the feedback linearisation strategy, and can be extremely sensitive to the excitation conditions.

EXPERIMENTS ON THE PERFORMANCE SENSITIVITY OF THE PASSIVE RESIDUAL HEAT REMOVAL SYSTEM OF AN ADVANCED INTEGRAL TYPE REACTOR

  • Park, Hyun-Sik;Choi, Ki-Yong;Choi, Seok;Yi, Sung-Jae;Park, Choon-Kyung;Chung, Moon-Ki
    • Nuclear Engineering and Technology
    • /
    • v.41 no.1
    • /
    • pp.53-62
    • /
    • 2009
  • A set of experiments has been conducted on the performance sensitivity of the passive residual heat removal system (PRHRS) for an advanced integral type reactor, SMART, by using a high temperature and high pressure thermal-hydraulic test facility, the VISTA facility. In this paper the effects of the opening delay of the PRHRS bypass valves and the closing delay of the secondary system isolation valves, and the initial water level and the initial pressure of the compensating tank (CT) are investigated. During the reference test a stable flow occurs in a natural circulation loop that is composed of a steam generator secondary side, a secondary system, and a PRHRS; this is ascertained by a repetition test. When the PRHRS bypass valves are operated 10 seconds later than the secondary system isolation valves, the primary system is not properly cooled. When the secondary system isolation valves are operated 10 or 30 seconds later than the PRHRS bypass valves, the primary system is effectively cooled but the inventory of the PRHRS CT is drained earlier. As the initial water level of the CT is lowered to 16% of the full water level, the water is quickly drained and then nitrogen gas is introduced into the PRHRS, resulting in the deterioration of the PRHRS performance. When the initial pressure of the PRHRS is at 0.1MPa, the natural circulation is not performed properly. When the initial pressures of the PRHRS are 2.5 or 3.5 MPa, they show better performance than did the reference test.

Performance Analysis On Antenna's On Antenna's Isolation for LEO Satellite Communication Service (저궤도위성통신시스템의 안테나 isolation에 따른 성능분석)

  • Kim Jong-Jin;Won Yoo-Hun
    • Proceedings of the Korean Information Science Society Conference
    • /
    • 2006.06d
    • /
    • pp.292-294
    • /
    • 2006
  • 본 논문은 저궤도 위성통신시스템의 이전까지 연구에 없었던 사용자 밀집도를 고려한 셀 내 단말기 분포에 따른 간섭의 변화를 살펴보고, 단말기 분포 평균 거리에 따른 최대 사용자 수를 살펴 보았다. 또한 저궤도 이동 통신시스템에 사용하는 안테나 종류(tapered-apertured antenna, gaussian antenna)의 스풋 빔 isolation값에 따른 간섭을 살펴보았다. 이러한 간섭을 저궤도 위성 통신 시스템의 채널용량에 대입하여, 중요한 파라미터(대역폭)를 가지고 성능분석을 하였다.

  • PDF

Optimal residual generation using parity space approach for a position servo system (패리티 공간기법을 이용한 위치 서보계의 최적 잔차 발생)

  • 최경영;박태건;이기상
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1997.10a
    • /
    • pp.1440-1443
    • /
    • 1997
  • The optimal residual generator based on parity relation approach for the fault detection and isolation of a arge diesel engine actuator position servo system is presented. The closed-loop residual generator is designed to have robustness against modeling errors and noise. Main purpose of the fault detection and isolation system in the process is to detect and isolate two important faults, i.e., actuatro fault and fault of speed sensor, that, if not detected and compensated, degrade the overall control system performance. Simulation results are give to show the practical applicability of the fault detecrtion and isloation scherme.

  • PDF