• Title/Summary/Keyword: Performance degradation

Search Result 3,425, Processing Time 0.038 seconds

Analysis of Correlation Between Silicon Solar Cell Fabrication Steps and Possible Degradation (실리콘 태양전지 제조공정과 열화의 상관관계 분석)

  • Yewon Cha;Suresh Kumar Dhungel;Junsin Yi
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.36 no.1
    • /
    • pp.16-22
    • /
    • 2023
  • In a solar cell, degradation refers to the decrease in performance parameters caused by defects originated due to various causes. During the fabrication process of solar cells, degradation is generally related to the processes such as passivation or firing. There exist sources of many types of degradation; however, the exact cause of Light and elevated Temperature Induced Degradation (LeTID) is yet to be determined. It is reported that the degradation and the regeneration occur due to the recombination of hydrogen and an arbitrary substance. In this paper, we report the deposition of Al2O3 and SiNX on silicon wafers used in the Passivated Emitter and Rear Contact (PERC) solar structure and its degradation pattern. A higher degradation rate was observed in the sample with single layer of Al2O3 only, which indicates that the degradation is affected by the presence or the absence of a passivation thin film. In order to alleviate the degradation, optimization of different steps should be carried out in consideration of degradation in the solar cell fabrication process.

A Study on the Performance Change of Insulation Sheath Due to Accelerated Degradation of IV and HIV Insulated Wire (IV 및 HIV 절연전선의 가속열화에 따른 절연피복의 성능변화에 관한 연구)

  • Choi, Su-Gil;Kim, Si-Kuk
    • Fire Science and Engineering
    • /
    • v.33 no.2
    • /
    • pp.114-123
    • /
    • 2019
  • The paper relates to a study on the changes in performance of insulation sheath resulting from accelerated degradation of IV and HIV insulated wire. To assume insulation degradation of IV and HIV insulated wire, accelerated life tests using Arrhenius equation were conducted among accelerated life test models, and experimental samples of 0 year, 10 years, 20 years, 30 years, and 40 years in equivalent life were produced. Whereas the maximum tensile load were increased as accelerated degradation of IV and HIV insulated wire progressed, elongation percentage, rupture time, and flexibility of insulated wires were found to be gradually reduced. According to the additional surface analysis results for the insulated wires per equivalent life using a scanning electron microscope, mechanical properties of the insulator were observed to be reduced as insulation degradation resulting from aging progressed since phenomena such as formation of crystalline structures and perforation, etc. occurred on the sample surface with progression of accelerated degradation. Consequently, institutional replacement of insulated wires and preparation of repair times considering performance degradation of the insulator installed inside buildings are considered necessary in order to prevent in advance the risks of electrical fire resulting from degradation in insulation performance.

Structural Vibration Control with $H_{\infty}$ Control Algorithm ($H_{\infty}$제어알고리즘을 이용한 구조물의 진동제어)

  • 고현무
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 1998.10a
    • /
    • pp.93-99
    • /
    • 1998
  • Mathematical model can be obtained by physical law or engineering theory. However it is always incomplete expression of the real system. In active controls to suppress vibration due to earthquake or wind load, modeling errors can often cause the problems of instability and performance degradation. In this paper, robust optimal controller design method using H$\infty$ control theory is developed for the systems which have uncertain natural frequency and design constraints. Numerical results show that the proposed H$\infty$ controller can avoid the performance degradation due to several errors and has better performance than conventional LQR method.

  • PDF

Degradation and Neutralization of Total Residual Oxidant (TRO) in the Treated Ballast Water by Ozonation

  • Park, Sung-Jin;Bin, Jung-In;Lee, Eon-Sung;Kim, In-Soo
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.34 no.3
    • /
    • pp.399-406
    • /
    • 2010
  • The aims of this study are to provide data on the ozone dosage control system and TRO sensor performance, to assess the performance of the degradation of total residual oxidant (TRO) neutralizer and to provide data on degradation rates of TRO in the ballast tanks, following treatment by the Ozone BWTS. This study includes the results of an evaluation of the TRO neutralizer, which was tested on the test barge. Accordingly, it has undertaken the evaluation of TRO degradation rates following treatment by the Ozone BWTS.

Performance degradation due to compressor fouling of an industrial gas turbine operating at design point condition (막오염에 의한 압축기 성능 저하가 발전용 가스터빈 설계점 성능에 미치는 영향에 관한 연구)

  • Seo, J.S.;Sohn, J.L.;Kim, J.H.;Kim, T.S.;Ro, S.T.
    • The KSFM Journal of Fluid Machinery
    • /
    • v.6 no.3 s.20
    • /
    • pp.36-43
    • /
    • 2003
  • Operating performance of industrial gas turbines in combined cycle power plants depends upon atmospheric conditions. Compressor fouling caused by airborne particles in the atmosphere and their adhesions on compressor blades is one of critical phenomena related to the performance degradation of industrial gas turbines. Compressor fouling provokes increase of pressure loss in inlet duct, decrease of mass flow rate of intake air and decrease of compressor stage efficiency. In this study, impacts of compressor fouling on the performance of an industrial gas turbine operating at design point condition are investigated analytically. As results, it is found that the reduction of produced power with decreased mass flow rate of intake air caused by narrowed flow area by the adhesion of airborne particles on compressor blades is the most dominant impact on the gas turbine performance by the compressor fouling phenomena.

Incorporating Performance Degradation in Fault Tolerant Control System Design with Multiple Actuator Failures

  • Zhang, Youmin;Jiang, Jin;Theilliol, Didier
    • International Journal of Control, Automation, and Systems
    • /
    • v.6 no.3
    • /
    • pp.327-338
    • /
    • 2008
  • A fault tolerant control system design technique has been proposed and analyzed for managing performance degradation in the presence of multiple faults in actuators. The method is based on a control structure with a model reference reconfigurable control design in an inner loop and command input adjustment in an outer loop. The reduced dynamic performance requirements in the presence of different actuator faults are accounted for through different performance reduced (degraded) reference models. The degraded steady-state performances are governed by the reduced levels of command input. The reconfigurable controller is designed on-line automatically in an explicit model reference control framework so that the dynamics of the closed-loop system follow that of the performance reduced reference model under each fault condition. The reduced command input level is determined to prevent potential actuator saturation. The proposed method has been evaluated and analyzed using an aircraft example against actuator faults subject to constraints on the magnitude and slew-rate of actuators.

Performance degradation of SOFC caused by increase of polarization resistance for the cathode during long-term test (공기극 분극 저항 증가에 따른 SOFC 단전지 성능 감소에 관한 연구)

  • Park, Kwang-Jin;Bae, Joong-Myeon
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2009.06a
    • /
    • pp.349-352
    • /
    • 2009
  • In this study, the relation between the performance degradation of SOFC single cell and the increase of polarization resistance for the cathode is investigated. $Pr_{0.3}Sr_{0.7}Co_{0.3}Fe_{0.7}O_3$(PSCF3737, $19.4{\times}10^{-6}K^{-1}$) and $Gd_{0.1}Ce_{0.9}O_2$ (CGO91, $12{\times}10^{-6}K^{-1}$) are used as a cathode and an electrolyte, respectively. The polarization resistance of cathode is increased due to the delamination caused by thermal expansion coefficient difference. The voltage drop with 10%/1000h decline rate occurs during long-term, when the interface between the cathode and the electrolyte is delaminated due to TEC difference.

  • PDF

Photocatalytic Degradation of Algae and its By-product using Rotating Photocatalytic Oxidation Disk Reactor

  • Son, Hee-Jong;Jung, Chul-Woo;Bae, Sang-Dae
    • Environmental Engineering Research
    • /
    • v.14 no.3
    • /
    • pp.170-173
    • /
    • 2009
  • This study examined the special technique of photocatalytic degradation (RPODisk) for removal of taste and odor causing materials, algae, and algal toxin. The RPODisk was effective for removal of these troublesome contaminants. It outperformed the fixed media and the UV irradiation for geosmin removal. The RPODisk performance was comparable to the combination of the UV irradiation with TiO2. The RPODisk performance was affected by the rotating speed. The faster the speed was, the better the performance. The RPODisk was also effective for removal of algae and algal toxin. The algal activity reduced by 80% after 30 mins of the treatment. More toxic microcystin (MC)-LR was more difficult to remove than MC-RR. The times for 50% removal were 23.7 mins for MC-LR and 14.1 mins for MC-RR. Almost 100 mins of the contact time was required to completely remove MC-LR at the rotating speed of 260 rpm.

The performance degradation of a folded-cascode CMOS op-amp due to hot-carrier effects (Hot-Carrier 현상에 의한 Folded-Cascode CMOS OP-Amp의 성능 저하)

  • 김현중;유종근;정운달;박종태
    • Journal of the Korean Institute of Telematics and Electronics D
    • /
    • v.34D no.12
    • /
    • pp.39-45
    • /
    • 1997
  • This study presents the first experimental data for the impact of hot-carrier degradtion on the performance of CMOS folded-cascode op-amps. A folded-cascode op-amp which has an NMOS input pair has been designed and fabricated using a 0.8.mu.m single-poly, double-metal CMOS process. After high voltage stress, the degradtion of perfomrance parameters such as open-metal CMOS process. After high voltage stress, the degradation of performance parameters such as open-loop voltage gain, unity-gain frequency and phase margin has been analized and physically explaniend in terms of hot carrier degradation.

  • PDF

BER DEGRADATION DUE TO THE PHASE NOISE SPECTRAL SHAPE IN LMDS SYSTEMS

  • Kim, Youngsun;Song, Jong-In;Kim, Kiseon
    • Proceedings of the IEEK Conference
    • /
    • 2000.07a
    • /
    • pp.113-116
    • /
    • 2000
  • Phase noise of oscillator gives the performance degradation significantly when a high carrier frequency and low transmission rate are used. The BER(Bit Error Rates) degradation of QPSK(Quadrature Phase Shift Keying) transmission is analyzed with the oscillator phase noise level specified in downstream physical interface of LMDS(Local Multipoint Distribution Services) which is described in DAVIC(Digital Audio Visual Council). The model used for the phase noise is a power-law model. We also investigated the effects of the various transmission rates on system performance. For the transmission rate below 0.5 Mbps, the BER performance is severely degraded and we verified that the transmission rate, 20 Mbps, is adequate for the downstream of LMDS systems.

  • PDF