• Title/Summary/Keyword: Performance Tests

Search Result 6,830, Processing Time 0.046 seconds

Treatment of Artificial Sewage Using a Zeolite Column (제올라이트 칼럼에 의한 인공생활하수처리)

  • Seo, Jeoung-Yoon
    • Korean Journal of Environmental Agriculture
    • /
    • v.21 no.3
    • /
    • pp.178-188
    • /
    • 2002
  • Constructed wetlands typically cost less to build and operate, and require less energy than standard mechanical treatment technology but they have similar performance to centralized wastewater treatment plants. Therefore, they were constructed especially many in rural areas, where are small villages but not industries. Plantless column tests were performed to investigate the possibility on using zeolite as a filter medium of constructed wetland for the wastewater treatment. Removal efficiency was $COD_{Cr}$ 94.63% T-P 41.41% and $NH_4^+-N$ 99.75% at hydraulic load 314 $L/m^2{\cdot}d$ and filtering height 100 cm filled with a zeolite mixture. This zeolite mixture consisted of 1 : 1 by volume of zeolites in the diameter range of 0.5 to 1 mm and 1 to 3 mm. Accordingly, hydraulic load 314 $L/m^2{\cdot}d$ was considered as optimal. Three zeolite mixtures were used to determine the optimal mixing ratio by volume of a zeolite (A) in the diameter range of 0.5 to 1 mm to a zeolite (B) in the diameter range of 1 to 3 mm 1 : 3, 1 : 1 and only B in A to B by volume were tested at hydraulic load 314 $L/m^2{\cdot}d$ and filtering height 100 cm $COD_{Cr}$ removal efficiency was more than 89% at mixing ratios of 1 : 3 and 1 : 1 in A to B. That of T-P ranged 56.42 to 58.72% and, that of T-N and $NH_4^+-N$ was 87% and 99% regardless of mixing ratios of two zeolites. Removal efficiency was lower at the column filled with only B. Removal efficiency was better at Inter medium filled with mixing ratio 1 : 1 in A to B than with the other mixing ratios. Thus, it was found that the mixture of mixing ratio 1 : 1 in A to B was appropriate far Inter medium of constructed wetland Removal efficiency was higher in down-flow than in up-flow, and all contaminants were removed most in 20 cm filter height near feeding area.

The Usefulness of LEUR Collimator for 1-Day Basal/Acetazolamide Brain Perfusion SPECT (1-Day Protocol을 사용하는 Brain Perfusion SPECT에서 LEUR 콜리메이터의 유용성)

  • Choi, Jin-Wook;Kim, Soo-Mee;Lee, Hyung-Jin;Kim, Jin-Eui;Kim, Hyun-Joo;Lee, Jae-Sung;Lee, Dong-Soo
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.15 no.1
    • /
    • pp.94-100
    • /
    • 2011
  • Purpose: Basal/Acetazolamide-challenged brain perfusion SPECT is very useful to assess cerebral perfusion and vascular reserve. However, as there is a trade off between sensitivity and spatial resolution in the selection of collimator, the selection of optimal collimator is crucial. In this study, we examined three collimators to select optimal one for 1-day brain perfusion SPECT. Materials and Methods: Three collimators, low energy high resolution-parallel beam (LEHR-par), ultra resolution-fan beam (LEUR-fan) and super fine-fan beam (LESFR-fan), were tested for 1-day imaging using Triad XLT 9 (TRIONIX). The SPECT images of Hoffman 3D brain phantom filled with 99mTc of 170 MBq and a normal volunteer were acquired with a protocol of 50 kcts/frame and detector rotation of 3 degree. Filterd backprojection (FBP) reconstruction with Butterworth filter (cut off frequencies, 0.3 to 0.5) was performed. The quantitative and qualitative assessments for three collimators were performed. Results: The blind tests showed that LESFR-fan provided the best image quality for Hoffman brain phantom and the volunteer. However, images for all the collimator were evaluated as 'acceptable'. On the other hand, in order to meet the equivalent signal-to-noise ratio (SNR), total acquisition time or radioactivity dose for LESFR-fan must have been increased up to almost twice of that for LEUR-fan and LEHR-par. The volunteer test indicated that total acquisition time could be reduced approximately by 10 to 14 min in clinical practice using LEUR-fan and LEHR-par without significant loss on image quality, in comparison with LESFR-fan. Conclusion: Although LESFR-fan provides the best image quality, it requires significantly more acquisition time than LEUR-fan and LEHR-par to provide reasonable SNR. Since there is no significant clinical difference between three collimators, LEUR-fan and LEHR-par can be recommended as optimal collimators for 1-day brain perfusion imaging with respect to image quality and SNR.

  • PDF

Comparison Study on Efficacies of Disinfectants and Sanitizers Among Methods for Quantitative Surface Test (살균소독제의 정량적 표면시험방법별 유효성 비교)

  • Kim, Ae-Young;Kim, Yong-Su;Ha, Sang-Do
    • Journal of Food Hygiene and Safety
    • /
    • v.25 no.3
    • /
    • pp.238-244
    • /
    • 2010
  • Currently, in vitro suspension tests using tubes are used as a authorized test method for sanitizers and disinfectants. However, the methods could not accurately assess the efficacy of sanitizers and disinfectant on the food-contacted surfaces in the field. This study evaluated the effectiveness of 5 kinds of representative sanitizers and disinfectants against E. coli and S. aureus to compare three quantitative surface testing methods that have been internationally standardized. As a result, the ASTM E2111-05 (ASTM(1)) test method obtained 5.18 $\pm$ 0.03 and 5.27 $\pm$ 0.04 log cfu/carrier reduction in dealing with E. coli and S. aureus, respectively, the ASTM E2197-02 (ASTM(2)) test method obtained 4.63 $\pm$ 0.04 and 3.97 $\pm$ 0.03 log cfu/carrier reduction and the CEN EN 13697 test method should 6.14 $\pm$ 0.05 and 5.31 $\pm$ 0.10 log cfu/carrier reduction in clean condition (CEN(1)) but 4.37 $\pm$ 0.02 and 4.06 $\pm$ 0.01 log cfu/carrier reduction in dirty condition (CEN(2)). Among them, CEN(1) showed the highest bactericidal effects, whereas ASTM(2) and CEN(2) revealed low performance (p < 0.05). In conclusion, the bactericidal effects of the ASTM(2) method and the CEN EN 13697 method adopting stainless steel were lower than the ASTM(1) method, which uses glass. The effectiveness assessment results among nationally accredited test methods were different each other. This implies that they could not fit for in the accurate evaluation of sanitization and disinfection on food-contact surfaces in practical food-processing fields. These results could be used as a basic data for establishment of an official surface test methods applicable in the field.

Electrochemical Decontamination of Metallic Wastes Contaminated with Uranium Compounds (우라늄화합물로 오염된 금속폐기물의 전해제염)

  • 양영미;최왕규;오원진;유승곤
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.1 no.1
    • /
    • pp.11-23
    • /
    • 2003
  • A study on the electrolytic dissolution of SUS-304 and Inconel-600 specimen was carried out in neutral salt electrolyte to evaluate the applicability of electrochemical decontamination process for recycle or self disposal with authorization of large amount of metallic wastes contaminated with uranium compounds generated by dismantling a retired uranium conversion plant in Korea. Although the best electrolytic dissolution performance for the specimens was observed in a Na2s04 electrolyte, a NaNO$_3$ neutral salt electrolyte, in which about 30% for SUS-304 and the same for Inconel-600 in the weight loss was shown in comparison with that in a Na$_2$SO$_4$ solution, was selected as an electrolyte for the electrochemical decontamination of metallic wastes with the consideration on the surface of system components contacted with nitric acid and the compatibility with lagoon wastes generated during the facility operation. The effects of current density, electrolytic dissolution time, and concentration of NaNO$_3$ on the electrolytic dissolution of the specimens were investigated. On the basis of the results obtained through the basic inactive experiments, electrochemical decontamination tests using the specimens contaminated with uranium compounds such as UO$_2$, AUC (ammonium uranyl carbonate) and ADU (ammonium diuranate) taken from an uranium conversion facility were performed in 1M NaNO$_3$ solution with the current density or In mA/$\textrm{cm}^2$. it was verified that the electrochemical decontamination of the metallic wastes contaminated uranium compounds was quite successful in a NaNO$_3$ neutral salt electrolyte by reducing $\alpha$ and $\beta$ radioactivities below the level of self disposal within 10 minutes regardless of the type of contaminants and the degree of contamination.

  • PDF

한국인 좌심실 비대증 환자들에서 파브리병 선별검사의 의의

  • Park, Hyeong-Du;Jo, Seong-Yun;Lee, Su-Yeon;Jeon, Eun-Seok;Park, Seung-U;Lee, Sang-Hun;Lee, Sang-Cheol;Choe, Jin-O;Park, Seong-Ji;Jang, Seong-A;Kim, Hyeong-Gwan;Gi, Chang-Seok;Kim, Jong-Won;Jin, Dong-Gyu
    • Journal of The Korean Society of Inherited Metabolic disease
    • /
    • v.14 no.2
    • /
    • pp.135-141
    • /
    • 2014
  • Objectives: Fabry disease (FD) is a lysosomal storage disease caused by the inappropriate accumulation of globotriaosylceramide (Gb3) in tissues due to a deficiency in the enzyme ${\alpha}$-galactosidase A. Hypertrophic cardiomyopathy is one of the chronic complications of FD. We tried to evaluate the prevalence of Fabry disease in the Korean patients with left ventricular hypertrophy (LVH). Methods: A total of 257 patients with LVH were recruited and they were 172 males (mean 56 years, range 30-81 years) and 84 females (mean 66 years, range 45-85 years). Urinary Gb3 was used to screen FD by high performance liquid chromatography-tandem mass spectrometry. Confirmatory tests were done by alpha-galactosidaseA activity using fluorometric assay and by GLA mutation analysis using sequencing. Results: Four patients were screening positive by urinary Gb3 analysis (cutoff, 25 ug/mmol creatinine). But, one female patient was diagnosed with FD confirmed by enzyme analysis in leukocytes as well as by genetic analysis (1/257 patients, 0.4%). She showed 54.3 ug/mmoL creatinine of Gb3 and 15.5 nmole/hr/mg protein (reference range, $55.2{\pm}12.7nmole/hr/mg$ protein) of alphagalactosidase A activity. And she had a heterozygous GLA mutation of c.796G>A (p.D266N). Her daughter was found to be a carrier for FD confirmed by GLA mutation analysis. Asymptomatic carrier showed 25.5ug/mmol creatinine of Gb3 and 42.5 nmole/hr/mg protein (reference range, $55.2{\pm}12.7nmole/hr/mg$ protein) of alpha-galactosidase A activity. Conclusions: The prevalence of FD in Koran patients with LVH was detected as 0.4%. Although the prevalence seems to be low, screening studies are of great importance for detecting hidden cases as well as for identifying other effected family members.

Development of Dust Recycling System and Dust Cleaner in Pipe during Vitrification of Simulated Non-Radioactive Waste (모의 비방사성폐기물의 유리화시 발생 분진의 재순환처리장치 및 배관 내 침적분진에 의한 막힘 방지용 제진장치의 개발)

  • Choi Jong-Seo;You Young-Hwan;Park Seung-Chul;Choi Seok-Mo;Hwang Tae-Won;Shin Sang-Woon
    • Proceedings of the Korean Radioactive Waste Society Conference
    • /
    • 2005.06a
    • /
    • pp.110-120
    • /
    • 2005
  • For utilizing vitrification to treat low and intermediate level waste, industrial pilot plant was designed and constructed in October 1999 at Daejon, Korea through the joint research program among NETEC, MOBIS and SGN. More than 70 tests were performed on simulated IER, DAW etc. including key nuclide surrogate(Cs, Co); this plant has been shown to vitrify the target waste effectively and safely, however, some dust are generated from the HTF(High Temperature Filter) as a secondary waste. In case of long term operation, it is also concerned that pipe plugging can be occurred due to deposited dust in cooling pipe namely, connecting pipe between CCM(Cold Crucible Melter) and HTF. In this regard, we have developed the special complementary system of the off-gas treatment system to recycle the dust from HTF to CCM and to remove the interior dust of cooling pipe. Main concept of the dust recycling is to feed the dust to the CCM as a slurry state; this system is regarded as of an important position in the viewpoint of volume reduction, waste disposal cost and glass melt control in CCM. The role of DRS(Dust Recycling System) is to recycle the major glass components and key nuclides; this system is served to lower glass viscosity and increase waste solubility by recycling B, Na, Li components into glass melt and also to re-entrain and incorporate into glass melt like Cs, Co. Therefore dust recycling is helpful to control the molten glass; it is unnecessary to consider a separate dust treatment system like a cementation equipment. The effects of Dust Cleaner are to prevent the pipe plugging due to dust and to treat the deposited dust by raking the dust into CCM. During the pilot vitrification test, overall performance assessment was successfully performed; DRS and Dust Cleaner are found to be useful and effective for recycling the dust from HTF and also removing the dust in cooling pipe. The obtained operational data and operational experiences will be used as a basis of the commercial facility.

  • PDF

The Analysis and Migration of Bisphenol A Related Compounds from Metal Food Cans (식품용 금속 캔으로부터 비스페놀 A 관련 물질들의 분석 및 이행 연구)

  • Park, Se-Jong;Park, So-Ra;Choi, Jae Chun;Kim, MeeKyung
    • Journal of Food Hygiene and Safety
    • /
    • v.32 no.4
    • /
    • pp.329-335
    • /
    • 2017
  • Analysis method was presented for the simultaneous determination of nine bisphenol A related compounds such as bisphenol A (BPA), phenol, p-tert-butylphenol, bisphenol A diglycidyl ether (BADGE), $BADGE{\cdot}2H_2O$, $BADGE{\cdot}2HCl$, bisphenol F diglycidyl ether (BFDGE), $BFDGE{\cdot}2H_2O$ and $BFDGE{\cdot}2HCl$ migrated from inner coatings of metal food cans by high performance liquid chromatography (HPLC) with fluorescence detection. The method was validated by examining the linearity of calibration curve, the limit of detection (LOD), the limit of quantification (LOQ), recovery and uncertainty. The migration tests of nine BPA related compounds were carried out with four food simulants; deionized water (DW), 4% acetic acid, 50% ethanol and n-heptane. There was not any compound detected in DW, 4% acetic acid and 50% ethanol at $60^{\circ}C$ for 30 min and n-heptane at $25^{\circ}C$ for 60 min. BPA and phenol were migrated into 4% acetic acid and 50% ethanol at $95^{\circ}C$ for 30 min. The concentrations were ranged from 0 to $10.77{\mu}g/L$ of BPA and from 0 to $2.35{\mu}g/L$ of phenol. Canned foodstuffs mostly have long-term shelf life. We investigated migration of nine BPA related compounds according to the variation in storage periods (0~90 days) and temperatures (4, 25 and $60^{\circ}C$). All compounds were not founded during 90 days at $4^{\circ}C$ and $25^{\circ}C$, respectively. However BPA and $BADGE{\cdot}2H_2O$ were founded in DW and 4% acetic acid at $60^{\circ}C$. The migration levels of BPA and $BADGE{\cdot}2H_2O$ were close to the value of LOQ, respectively and did not change significantly as storage period. It was founded from results that the migration of BPA related compounds from metal food cans was controlled to a safe level.

Study on Reesterification of Rice Bran Oil Containing High Free Fatty Acids and Glycerol (유리지방산을 많이 함유한 미강유와 글리세린의 에스테르화 반응에 관한 연구)

  • Moon, Sung-Hoon;Rhee, Joon-Shick
    • Korean Journal of Food Science and Technology
    • /
    • v.12 no.3
    • /
    • pp.193-199
    • /
    • 1980
  • A series of tests were conducted on the reesterification of rice bran oil containing high free fatty acids (acid value=119.7) with theoretical equivalent of glycerol. Test results showed that reaction rate (in terms of decrease in acid value) was increased as the reaction temperature was increased regardless of the presence of the catalyst and reaction time (42.7, 21.5 and 10.0 at $170^{\circ}C,\;210^{\circ}C\;and\;250^{\circ}C$, respectively) and as the reaction time was increased regardless of the temperature and the presence of the catalyst (31.1 vs 18.3 for 3 hrs vs 6 hrs). The presence of the catalyst (0.2% tin chloride) also accelerated the rate regardless of the reaction temperature and time (36.9 vs 12.5). Analysis by column chromatography showed that content of triglyceride in the oil was increased to 72.9% and 61.1% from 10.4% and content of free fatty acids in the oil was decreased to 1.4% and 6.1% from 60.2%, when the degummed oil was esterified at $250^{\circ}C$ for 6 hrs in the presence of and in the absence of the catalyst, respectively. The results estimated from the iodine values indicate that polymer formation was not significant, when the oil was esterified for 6 hrs at temperatures up to $210^{\circ}C$. However, it was somewhat significant for the oil esterified at $250^{\circ}C$ for 6 hrs. The catalyst did not affect the polymer formation. Analysis by high performance liquid chromatography showed that oleic acid (42.5%), linoleic acid (29.0%) and palmitic acid (20.3%) were the major fatty acid components of the rice bran oil.

  • PDF

Current Wheat Quality Criteria and Inspection Systems of Major Wheat Producing Countries (밀 품질평가 현황과 검사제도)

  • 이춘기;남중현;강문석;구본철;김재철;박광근;박문웅;김용호
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.47
    • /
    • pp.63-94
    • /
    • 2002
  • On the purpose to suggest an advanced scheme in assessing the domestic wheat quality, this paper reviewed the inspection systems of wheat in major wheat producing countries as well as the quality criteria which are being used in wheat grading and classification. Most wheat producing countries are adopting both classifications of class and grade to provide an objective evaluation and an official certification to their wheat. There are two main purposes in the wheat classification. The first objectives of classification is to match the wheat with market requirements to maximize market opportunities and returns to growers. The second is to ensure that payments to glowers aye made on the basis of the quality and condition of the grain delivered. Wheat classes has been assigned based on the combination of cultivation area, seed-coat color, kernel and varietal characteristics that are distinctive. Most reputable wheat marketers also employ a similar approach, whereby varieties of a particular type are grouped together, designed by seed coat colour, grain hardness, physical dough properties, and sometimes more precise specification such as starch quality, all of which are genetically inherited characteristics. This classification in simplistic terms is the categorization of a wheat variety into a commercial type or style of wheat that is recognizable for its end use capabilities. All varieties registered in a class are required to have a similar end-use performance that the shipment be consistent in processing quality, cargo to cargo and year to year, Grain inspectors have historically determined wheat classes according to visual kernel characteristics associated with traditional wheat varieties. As well, any new wheat variety must not conflict with the visual distinguishability rule that is used to separate wheats of different classes. Some varieties may possess characteristics of two or more classes. Therefore, knowledge of distinct varietal characteristics is necessary in making class determinations. The grading system sets maximum tolerance levels for a range of characteristics that ensure functionality and freedom from deleterious factors. Tests for the grading of wheat include such factors as plumpness, soundness, cleanliness, purity of type and general condition. Plumpness is measured by test weight. Soundness is indicated by the absence or presence of musty, sour or commercially objectionable foreign odors and by the percentage of damaged kernels that ave present in the wheat. Cleanliness is measured by determining the presence of foreign material after dockage has been removed. Purity of class is measured by classification of wheats in the test sample and by limitation for admixtures of different classes of wheat. Moisture does not influence the numerical grade. However, it is determined on all shipments and reported on the official certificate. U.S. wheat is divided into eight classes based on color, kernel Hardness and varietal characteristics. The classes are Durum, Hard Red Spring, Hard Red Winter, Soft Red Winter, Hard White, soft White, Unclassed and Mixed. Among them, Hard Red Spring wheat, Durum wheat, and Soft White wheat are further divided into three subclasses, respectively. Each class or subclass is divided into five U.S. numerical grades and U.S. Sample grade. Special grades are provided to emphasize special qualities or conditions affecting the value of wheat and are added to and made a part of the grade designation. Canadian wheat is also divided into fourteen classes based on cultivation area, color, kernel hardness and varietal characteristics. The classes have 2-5 numerical grades, a feed grade and sample grades depending on class and grading tolerance. The Canadian grading system is based mainly on visual evaluation, and it works based on the kernel visual distinguishability concept. The Australian wheat is classified based on geographical and quality differentiation. The wheat grown in Australia is predominantly white grained. There are commonly up to 20 different segregations of wheat in a given season. Each variety grown is assigned a category and a growing areas. The state governments in Australia, in cooperation with the Australian Wheat Board(AWB), issue receival standards and dockage schedules annually that list grade specifications and tolerances for Australian wheat. AWB is managing "Golden Rewards" which is designed to provide pricing accuracy and market signals for Australia's grain growers. Continuous payment scales for protein content from 6 to 16% and screenings levels from 0 to 10% based on varietal classification are presented by the Golden Rewards, and the active payment scales and prices can change with market movements.movements.

Investigation of Microbial Contamination Levels of Leafy Greens and Its Distributing Conditions at Different Time - Focused on Perilla leaf and Lettuce - (시기별 엽채류의 미생물 오염도와 유통 조건 조사 - 들깻잎과 상추를 중심으로 -)

  • Kim, Won-Il;Jung, Hyang-Mi;Kim, Se-Ri;Park, Kyeong-Hun;Kim, Byung-Seok;Yun, Jong-Chul;Ryu, Kyoung-Yul
    • Journal of Food Hygiene and Safety
    • /
    • v.27 no.3
    • /
    • pp.277-284
    • /
    • 2012
  • The objective of this study was to investigate and evaluate microbial contamination levels of leafy greens (perilla leaf and lettuce) and its distributing conditions at different seasons (Feb, May, Aug, and Nov of the year 2011) in order to provide insight into any potential health hazards associated with consumption of these commodities. Leafy greens were collected from a farm located in Geumsan, Chungnam and wholesale markets (WM) and traditional markets (TM) located in Suwon. At the same time, temperature and relative humidity fluctuations experienced by the leafy greens during distribution from the farm to the distribution center were measured by a data logger. The contamination levels of perilla leaf and lettuce were determined by analyzing total plate count. Coliform groups, Bacillus cereus, Escherichia coli, Escherichia coli O157:H7, Salmonella spp., Listeria monocytogenes and Staphylococcus aureus were determined. The contamination levels of total aerobic bacteria, coliform groups and B. cereus in both vegetables sampled during May and August found to be higher than those sampled during February and November. E. coli O157:H7, Salmonella spp., L. monocytogenes were not detected in the vegetables analyzed in this study. There were no significant trends between samples at WM and TM in the contamination levels. Relative humidity of vegetables distributed from the farm to the distribution center showed over 90% during distribution regardless of measured seasons. In the case of background microflora on leafy greens, the density was significantly increased at 20, 30 and $37^{\circ}C$ during storage of 24h. E. coli O157:H7 and B. cereus inoculated on the leaves also showed similar increases in the storage tests. The microbial contamination levels determined in this study may be used as the fundamental data for microbial risk assessment.