• Title/Summary/Keyword: Performance Tests

Search Result 6,786, Processing Time 0.034 seconds

The Performance Analysis to Identify the Reuse and Assembly Impact of Temporary Equipment

  • Bae, Sung-Jae;Park, Jun-Beom;Kim, Jung-Yeol;Kim, Young-Suk;Kim, Jun-Sang;Jo, Jae-Hun
    • International conference on construction engineering and project management
    • /
    • 2022.06a
    • /
    • pp.1252-1252
    • /
    • 2022
  • Temporary work that utilizes temporary equipment (e.g., system scaffold and system pipe support) in construction work is one of the most vulnerable work from a safety perspective in South Korea. Typically, temporary equipment is reused at construction sites. The Korea Occupational Safety and Health Agency announced guidelines regarding the performance standards for reusable temporary equipment to prevent the accidental collapse of temporary facilities. Nevertheless, temporary facilities' collapse still occurs, which could be attributed to a degradation in the performance due to the reuse of temporary equipment. Therefore, this study investigated the performance of simple temporary structures assembled with new and reused equipment. To this end, an experimental module was designed based on previous research cases, and two experimental models were constructed, in which one was assembled using new equipment (Model A), and the other was built using reused equipment (Model B). To determine the performance of each model, a load test was conducted to measure the maximum load that each model could withstand. The experimental results revealed that the maximum load of Model B was 15% lower than that of Model A. This indicates that there is a meaningful performance difference between those two models. Based on this result, the authors decided to perform additional tests with more realistic models than previous ones. The new experimental module was designed to ensure compliance with the Korean design guidelines. In this presentation, the authors show details of the first tests and their results and plan for the additional test.

  • PDF

A study about an old age car performance characteristic (노후차량 성능 특성에 관한 연구)

  • Hong Yong-Ki;Kwon Sung-Tae
    • Proceedings of the KSR Conference
    • /
    • 2005.11a
    • /
    • pp.332-337
    • /
    • 2005
  • In order to investigate performance changes, the acceleration, vibration, and braking performance tests were carried out on the electric multiple units (EMUs) with over 20 years operation. According to the testing results, in vibration and braking performance, the similar performance results were obtained as compared with newly manufactured EMUs. However, in terms of acceleration performance, below reference value (3.0 km/h/s) has been obtained. This is mainly due to performance deterioration including traction motor. The precision diagnosis evaluation of deteriorated EMUs will be provided through the overall evaluation of corrosion testing and structural performance of car body.

  • PDF

The Evaluation of Fire-Resistant Performance of the Non-bearing Steel Wall Using Fire Resistant Glass (내화유리를 적용한 강재 유리벽의 내화성능 평가)

  • Lee, Jae-Sung;Yim, Hyun-Chang;Yang, Seung-Cho
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.22 no.5
    • /
    • pp.72-81
    • /
    • 2018
  • Fireproof structures using concrete, built-up panels and dry walls are usually used in walls inside fire compartments. However, demand for glass walls is emerging due to increase in interest in visibility and external appearance. In this study on steel fire resistance walls using insulation glass, fire resistance tests and performance evaluations were conducted on 60 minute fire resistance walls and exterior walls which could be applied to interior fire compartments and 90 minute fire resistance walls which could be applied to curtain walls. According to the tests, the specimens satisfied the required fire resistance performance. The finite element analysis was conducted after the tests to evaluate the fire resistance performance of the glass walls. The analysis results showed that the preliminary evaluation of fire resistance performance would be feasible.

A Study to Evaluate Performance of Poly-Urethane Polymer Concrete for Long-Span Orthotropic Steel Bridge (장경간 강바닥판 케이블교량에 적용하기 위한 폴리우레탄 폴리머콘크리트의 공용특성 연구)

  • Park, Heeyoung;Lee, Junghun;Kwak, Byeongseok;Choi, Iehyun;Kim, Taewoo
    • International Journal of Highway Engineering
    • /
    • v.15 no.1
    • /
    • pp.1-9
    • /
    • 2013
  • PURPOSES: The purpose of this study is to evaluate physical properties, durability, fatigue resistance, and long-term performance of poly-urethane concrete (PU) which can be possible application of thin layer on long-span orthotropic steel bridge and to check structural stability of bridge structure. METHODS : Various tests of physical properties, such as flexural strength, tensile strength, bond strength and coefficient of thermal expansion tests were conducted for physical property evaluation using two types of poly urethane concrete which have different curing time. Freezing and thawing test, accelerated weathering test and chloride ion penetration test were performed to evaluate the effect of exposed to marine environment. Beam fatigue test and small scale accelerated pavement test were performed to assess the resistance of PU against fatigue damage and long-term performance. Structural analysis were conducted to figure out structural stability of bridge structure and thin bridge deck pavement system. RESULTS: The property tests results showed that similar results were observed overall however the flexural strength of PUa was higher than those of PUb. It was also found that PU materials showed durability at marine environment. Beam fatigue test results showed that the resistances of the PUa against fatigue damage were two times higher than those of the PUb. It was found form small scale accelerated pavement test to evaluate long-term performance that there is no distress observed after 800,000 load applications. Structural analysis to figure out structural stability of bridge structure and thin bridge deck pavement system indicated that bridge structures were needed to increase thickness of steel deck plate or to improve longitudinal rib shape. CONCLUSIONS: It has been known that the use of PU can be positively considered to thin layer on long-span orthotropic steel bridge in terms of properties considered marine environment, resistance of fatigue damage and long-term performance.

Identification of Age Threshold for Driving Performance (운전능력에 연관된 인적특성의 연령 임계점 연구)

  • Kim, Tae-Ho;Ko, Joon-Ho;Won, Jai-Mu;Hu, Ec
    • Journal of the Korean Society of Safety
    • /
    • v.23 no.3
    • /
    • pp.71-78
    • /
    • 2008
  • This study aims to identity the age group where driving performance significantly decreases based on the data collected from the Korea Transportation Safety Authority's driver aptitude tests in 2006. The test includes following six driving simulator-based tests: estimation of moving objects' speed, estimation of stopping distance, three tests for drivers' multi-task ability, and kinetic depth perception. These six test results were utilized for the identification of the age threshold applying the CART technique, suggesting driving ability significantly be decreased over 50s. This finding was confirmed by two analyses using the accident history data containing the information of accident and non-accident drivers and the degree of accident severity. The results of this study imply that accident prevention efforts should be enhanced over a wider range of age group than the current practice where the age of 65 is generally applied for the threshold dividing senior and non-senior driver groups.

A Study on the Shear Fatigue Performance of Elastomeric Bearings of a Doublefold Elastomeric Layer (고무의 겹침제작 여부에 따른 탄성받침의 전단피로특성 연구)

  • Yoon, Hye-Jin;Kwahk, Im-Jong;Kim, Young-Jin
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.11a
    • /
    • pp.69-72
    • /
    • 2008
  • Bridge bearings are devices absorbing the displacements of the superstructure. Elastomeric bearings used generally as bridge bearings absorb the displacements of the superstructure using their rubber characteristics. Elastomeric bearings should make sure their shear fatigue performance not to impede the durability of bridge system. In this paper shear fatigue tests were performed and stiffness were measured through the shear fatigue tests. Tests results show the measured stiffness of elastomeric bearings have no specific tendency. This paper found that elastomeric bearings show bad shear performance or fail early if elastomeric bearings are manufactured with a doublefold elastomeric layer.

  • PDF

Performance Evaluations of Mock-up Tests for ALC Panel Curtain Wall in Building Exterior (ALC 패널을 활용한 건축물 외장 커튼월에 대한 Mock-up Test 성능 평가 연구)

  • Kim, Young-Ho;Lee, Yong-Soo
    • Journal of The Korean Digital Architecture Interior Association
    • /
    • v.13 no.4
    • /
    • pp.25-32
    • /
    • 2013
  • The green building is one of biggest factors to go the goal of energy saving and environmental conservation, reduction of energy consumption, friendly energy technology, recycling of resource, and environmental pollution reduction technology. The purpose of these green buildings realized by the energy-saving technology such as the exterior materials or curtain wall system. The curtain wall system is a element that come to insulated portions of building envelope that results in heat loss. The purpose of this paper is to carried out mock-up tests for exterior wall used in autoclaved lightweight concrete panels in green building practices. Mock-up test execute a mixed process between standard test procedure and complex test procedure based on AAMA 501(American Society for Testing and Materials) and ASTM 283, ASTM 330(American Society for Testing and Materials). In results, tests meet the requirements that grant values in steps of procedures provided on ASTM and AAMA. ALC panel is suitable for a exterior wall product to be gratified thermal cycling performance and structural capacity, deflection(H/200) and lateral displacement(H/50), for curtain walls.

Stabilization of Meles Delta soils using cement and lime mixtures

  • Onal, Okan;Sariavci, Cagrihan
    • Geomechanics and Engineering
    • /
    • v.19 no.6
    • /
    • pp.543-554
    • /
    • 2019
  • İzmir Bay reserves high amount of residual alluvial deposits generated by Meles River at its stream mouth. These carried sediments with high water content and low bearing capacity are unsuitable in terms of engineering purposes. In-situ soil stabilization with deep soil mixing method is considered to improve properties of soil in this location. This method is widely used especially over Scandinavia, Japan and North America. Basically, the method covers mixing appropriate binder into the soil to improve soil profile according to the engineering needs. For this purpose, soil samples were initially provided from the site, classification tests were performed and optimum ratios of lime and cement binders were determined. Following, specimens representing the in-situ soil conditions were prepared and cured to be able to determine their engineering properties. Unconfined compression tests and vane shear tests were applied to evaluate the stabilization performance of binders on samples with different curing periods. Scanning electron microscope was used to observe time-dependent bonding progress of binders in order to validate the results. Utilization of 4% lime and 4% cement mixture for the long-term performance and 8% lime and 8% cement mixture for short term performance were suggested for the stabilization of Meles Delta soils. Development of CSH and CAH in a gel form as well as CSH crystals were clearly observed on SEM images of treated specimens.

Diabetics' Preference in the Design Factors and Performance Requirements of Diabetic Socks (당뇨환자의 당뇨양말 디자인요소 선호도와 요구성능)

  • Lee, Ji-Eun;Kwon, Young-Ah
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.35 no.5
    • /
    • pp.527-536
    • /
    • 2011
  • Diabetics often suffer from the complications of foot disease. Foot discomfort results from poor blood circulation. Thus, diabetics should wear socks that do not constrict the blood flow in the feet and legs. This study examines the design factors and performance requirements of socks for diabetics. We apply the results to the development of socks for diabetic. The participants in this study were 112 diabetic patients who had visited a hospital in Busan. We conducted statistical tests that included t-tests and chi-squared tests. The results depended on age and gender. Male and female patients did not differ from each other in the most favorite style; however, their second favorite style was different. The second most preferred style for male patients was calf-length socks, while the second most preferred style for female patients were ankle-length socks. Male patients preferred black or gray socks, while female patients preferred white socks. Socks for diabetics should be machine washable, easy to remove, non-slip, lightweight, comfortable, deodorized, and antibacterial.

Linear Motor Damper for Vibration Control of Flexible Structure (유연 구조물의 진동제어를 위한 선형모터댐퍼)

  • Sim Sangdeok;Kang Hoshik;Song Ohseop;Kim Youngchan;Kim Doohoon
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.15 no.4 s.97
    • /
    • pp.492-498
    • /
    • 2005
  • A linear motor damper based on the linear motor principle is developed to suppress structural vibration. This paper deals with the design, analysis, and manufacture of the linear motor damper. It is designed to be able to move the auxiliary mass of 1500kg, up to $\pm250mm$ stroke. The control algorithm was designed based on LQG control logic with acceleration feedback. Through performance tests, it was confirmed that the developed hybrid mass damper has reliable feasibility as a control device for structural control. In addition, the linear motor damper is more economical than both hydraulic and electric motor driving mass damper with respect to simple structure and low maintenance cost. A series of performance tests of the linear motor damper system were carried out on the full-scale steel frame structure in UNISON Corporation. Through the performance tests, it was confirmed that acceleration levels are reduced down 10dB for first mode of structure