• Title/Summary/Keyword: Performance Testing System

Search Result 1,319, Processing Time 0.034 seconds

DEVELOPMENT OF A CRYOGENIC TESTING SYSTEM FOR MID-INFRARED DETECTORS ON SPICA

  • Nishiyama, Miho;Kaneda, Hidehiro;Ishihara, Daisuke;Oseki, Shinji;Takeuchi, Nami;Nagayama, Takahiro;Wada, Takehiko
    • Publications of The Korean Astronomical Society
    • /
    • v.32 no.1
    • /
    • pp.355-357
    • /
    • 2017
  • For future space IR missions, such as SPICA, it is crucial to establish an experimental method for evaluating the performance of mid-IR detectors. In particular, the wavelength dependence of the sensitivity is important but difficult to be measured properly. We are now preparing a testing system for mid-IR Si:As/Si:Sb detectors on SPICA. We have designed a cryogenic optical system in which IR signal light from a pinhole is collimated, passed through an optical filter, and focused onto a detector. With this system, we can measure the photoresponse of the detector for various IR light using optical filters with different wavelength properties. We have fabricated aluminum mirrors which are adopted to minimize thermal distortion effects and evaluated the surface figure errors. The total wavefront error of the optical system is $1.3{\mu}m$ RMS, which is small enough for the target wavelengths ($20-37{\mu}m$) of SPICA. The point spread function measured at a room temperature is consistent with that predicted by the simulation. We report the optical performance of the system at cryogenic temperatures.

A Study on the Low Cost Testing System Development of the Low Speed and High Torque Harsh Reducer (저속 고토크 가혹감속기의 저비용 테스트 시스템 개발에 관한 연구)

  • Park, Taehyun
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.25 no.3
    • /
    • pp.379-386
    • /
    • 2022
  • The goal of this research is to verify a performance test system for a low speed, high torque, and harsh reducer at low cost. The reducer rotates a cooling fan with a diameter of 10 meters, in a high temperature (50℃) cooling tower in a geothermal power plant. It requires about 500 kgf·m torque and 47.75 kW power to rotate the fan at a maximum power condition. An expensive dynamometer is commonly used for performance test of a motor or a reducer. In this paper, a low cost system is developed using a hydraulic pump as a load unit to generate torque instead of a dynamometer. We accurately calculated the required power, the flow meter, and the pressure of the pump, and selected to design and optimize the system at minimal cost. The system also applied another reverse reducer and a gearbox to increase the rotational speed and to reduce the torque from the low speed and high torque target reducer. This allows low-cost systems to be built using inexpensive components. The developed system was able to successfully measure the high torque and the low rotational speed of the target reducer at high temperature.

A Study on On-site Discharge Testing for Carbon Dioxide Fire Extinguishing Systems (이산화탄소 소화설비 현장 방출시험 방법론에 관한 고찰)

  • Park, Jun-Hyun;Kang, Tae-Seok;Kim, Jae-Hwan;Kim, Wee-Kyong
    • Fire Science and Engineering
    • /
    • v.29 no.4
    • /
    • pp.26-32
    • /
    • 2015
  • Carbon dioxide principally extinguishes fires by smothering, but an acceptable amount of extinguishing agent is needed. To assure the performance of carbon dioxide systems in Korea, computer programs certified by NEMA are being applied in system design. But the design errors can occur because the geometry of a model test facility is not the same as that of the actual fire area. Since the discharge rate tends to vary considerably with the flow pattern in a pipe, an on-site discharge test is necessary to ensure the performance of the system, especially with low pressure carbon dioxide. Technical standards for carbon dioxide systems do not give detailed guidelines for discharge tests at present. Based on comparative analysis of standards and practical tests, this paper suggests a methodology for on-site discharge tests.

Research about the Effect that Taekwondo Shoes have on the Performance and Friction during the Turing and Turning Back Kick (태권도 돌려차기와 몸돌려 후려차기시 태권도화 착용에 따른 기계적 마찰력과 태권도 수행력 연구)

  • Park, Seung-Bum;Lee, Jung-Ho
    • Korean Journal of Applied Biomechanics
    • /
    • v.18 no.1
    • /
    • pp.117-127
    • /
    • 2008
  • The purpose of this study was to investigate the relationship between research of mechanical friction and Taekwondo kick performance. For this a Taekwondo kick performance test, A.F.T.S.(Automated Footwear Testing System) and survey about fitting was used. There was a statistically significant difference between all the Taekwondo shoe types. While performing the roundhouse kick there were statistically significant differences in the peak free moment(p=.01) and peak plantar pressure between type A and B. Comfort testing revealed that there were statistically significant difference between type A and B in the five comfort variables tested but not between type B and Type C. There was statistically significant differences between each of the Taekwondo shoes but there was no relationship between the performance and the results of the survey.

Wind Analysis and Site Assessment for Test Site of 3MW Wind Power System (3MW 풍력발전시스템 개발품의 육상풍력실증단지 조성 타당성 평가를 위한 풍황 및 지형평가 연구)

  • Woo, Sangwoo;Lee, Ki-Hak;Lee, Sang-Il;Park, Jong-Po
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2011.11a
    • /
    • pp.35.2-35.2
    • /
    • 2011
  • A wind turbine power performance test is very important to wind turbine manufacturers because a wind farm developer or planner must want to define power performance characteristics and reliability of new wind turbines. Based on the IEC 61400-12-1, A wind turbine test site has to be nicely installed at flat terrain for testing. We are developing the wind power system which is IEC wind class IIa model with rated power of 3MW. KEPCO's Gochang power testing center was considered as candidates to build the test site without site calibration. This paper aims to verify the validity of the test site by using implement site assessment result that was based on IEC 61400-12-1.

  • PDF

Development of a truncation artifact reduction method in stationary inverse-geometry X-ray laminography for non-destructive testing

  • Kim, Burnyoung;Yim, Dobin;Lee, Seungwan
    • Nuclear Engineering and Technology
    • /
    • v.53 no.5
    • /
    • pp.1626-1633
    • /
    • 2021
  • In an industrial field, non-destructive testing (NDT) is commonly used to inspect industrial products. Among NDT methods using radiation sources, X-ray laminography has several advantages, such as high depth resolution and low computational costs. Moreover, an X-ray laminography system with stationary source array and compact detector is able to reduce mechanical motion artifacts and improve inspection efficiency. However, this system, called stationary inverse-geometry X-ray laminography (s-IGXL), causes truncation artifacts in reconstructed images due to limited fields-of-view (FOVs). In this study, we proposed a projection data correction (PDC) method to reduce the truncation artifacts arisen in s-IGXL images, and the performance of the proposed method was evaluated with the different number of focal spots in terms of quantitative accuracy. Comparing with conventional techniques, the PDC method showed superior performance in reducing truncation artifacts and improved the quantitative accuracy of s-IGXL images for all the number of focal spots. In conclusion, the PDC method can improve the accuracy of s-IGXL images and allow precise NDT measurements.

Performance Evaluation of Snort System

  • Kim, Wan-Kyung;Soh, Woo-Young
    • Journal of the Speleological Society of Korea
    • /
    • no.80
    • /
    • pp.11-19
    • /
    • 2007
  • Most studies in the past in testing and benchmarking on Intrusion Detection System (IDS) were conducted as comparisons, rather than evaluation, on different IDSs. This paper presents the evaluation of the performance of one of the open source IDS, snort, in an inexpensive high availability system configuration. Redundancy and fault tolerance technology are used in deploying such IDS, because of the possible attacks that can make snort exhaust resources, degrade in performance and even crash. Several test data are used in such environment and yielded different results. CPU speed, Disk usage, memory utilization and other resources of the IDS host are also monitored. Test results with the proposed system configuration environment shows much better system availability and reliability, especially on security systems.

The Effect of ISO 9001 : 2000 Quality Management System's Requirement on Business Performance (ISO 9001 : 2000 품질경영시스템의 요구사항이 경영성과에 미치는 영향)

  • Goh, Hyun-Woo;Chung, Young-Bae
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.30 no.3
    • /
    • pp.135-149
    • /
    • 2007
  • This paper investigates the relative effect of each ISO 9001 : 2000 quality management system's requirement and business performance. The empirical tests are conducted in ISO 9001 certification companies. As a result, the $1^{st}$, it shows the requirements positively affect performance of financial. The $2^{nd}$, also it shows the requirements positively affect non-financial performance. The $3^{rd}$ also it show the non-financial performance positively effect performance of financial performance.

A Study on the Evaluation of Dynamic Characteristics of the Pantograph for the Korean High-Speed Train through 350km/h Trial Running Test (350km/h 본선 주행시험을 통한 한국형 고속열차 판토그라프의 접촉력 특성 평가 연구)

  • Lee Hi-Sung;Mok Jin-Yong
    • Journal of the Korean Society for Railway
    • /
    • v.8 no.4
    • /
    • pp.342-347
    • /
    • 2005
  • The Korean High-Speed Train(HSR 350x) had been developed by through 'G7-R&D project' in 1996-2002, and has been testing and evaluating it's reliability on the high-speed line until now. A number of core equipments designed and developed by using domestic technologies were boarded on the HSR 350x. In order to verify the performance of HSR 350x and core equipments such as traction system, brake system and pantograph, sophisticated testing and evaluating procedures should be considered and applied. In this paper, the tested and analysed results about the dynamic characteristics of HSR 350x pantograph are introduced in a view point of the mean contact force and it's variation trend, criterion of current collection, and up-lifting of contact wire when the MSR 350x running up to 350 km/h. Through the test and evaluation, we verified that HSR 350x pantograph had an excellent current collection performance and good dynamic characteristics as it had been designed.

Development of Performance Analysis S/W for Wind Turbine Generator System (풍력발전시스템 성능 해석 S/W 개발에 관한 연구)

  • Mun, Jung-Heu;No, Tae-Soo;Kim, Ji-Yon;Kim, Sung-Ju
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.36 no.2
    • /
    • pp.202-209
    • /
    • 2008
  • Application of wind turbine generator system (WTGS) needs researches for performance prediction, pitch control, and optimal operation method. Recently a new type WTGS is developed and under testing. The notable feature of this WTGS is that it consists of two rotor systems positioned horizontally at upwind and downwind locations, and a generator installed vertically inside the tower. In this paper, a nonlinear simulation software developed for the performance prediction of the Dual Rotor WTGS and testing of various control algorithm is introduced. This software is hybrid in the sense that FORTRAN is extensively used for the purpose of computation and Matlab/Simulink provides a user friendly GUI-like environment.