• Title/Summary/Keyword: Performance Tester

Search Result 300, Processing Time 0.028 seconds

Design of the Linear Propulsion System of a High-Speed Dynamic Tester for Catenary-Current Collection (전차선로-집전계 주행시험기용 리니어 추진시스템 설계)

  • Kwon, Sam-Young;Lee, Ju
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.20 no.8
    • /
    • pp.63-70
    • /
    • 2006
  • This paper presents design of the linear propulsion system of a high-speed (200km/h) dynamic tester for catenary-current collection. Among various propulsion systems, a permanent magnet linear synchronous motor is chosen for need of high acceleration force. The design is performed by the equivalent magnetic circuit method and verified by the finite element method. In addition, analysis of the main effects of various design variables for performance of the propulsion system has been done by using simulation-based DOE method.

Experimental Research for Air-borne Noise Reduction of a Multi-layered Insulation (다층 인슐레이션의 차음성능에 대한 실험적 연구)

  • 고강호;김영호;국형석
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2001.05a
    • /
    • pp.1185-1191
    • /
    • 2001
  • This paper discusses an experimental method for measuring the insertion loss (IL) performance of multi-layered insulations that are used in vehicles. Instead of two adjacent reverberation chambers which are generally used to measure the transmission loss (TL) of the large sound isolation materials, air-borne sound insulation tester was utilized to determine the IL and articulation index (AI) of standardized insulation materials. In comparison to reverberation chamber method, air-borne sound insulation tester method is more space-saving, more time-saving and more simple to the automotive acoustics. From the empirical results, it is found that the performances of insulation materials are closely connected with density of polyurethane foam, thickness of heavy layer, thickness of polyurethane foam, and application ratio to panel area.

  • PDF

Measurement of Two Dimensional Magnetic Properties of Electrical Steel Sheets under Rotating Magnetic Fields (전기강판의 회전자계 하에서의 2차원 자계특성 측정)

  • Eum, Young-Hwan;Hong, Sun-Ki;Shin, Pan-Seok;Koh, Chang-Seop
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.55 no.12
    • /
    • pp.617-622
    • /
    • 2006
  • It is necessary to measure precisely the magnetic characteristics of electrical steel sheets under rotating magnetic fields, to obtain an accurate numerical performance analysis of electric machines made of electrical steel sheets. In this paper, the two dimensional magnetic characteristics of an electrical steel sheet are measured and explained under rotating magnetic fields using a two-axes-excitation type single sheet tester (SST). Through experiments, the magnetic properties, under rotating magnetic fields, of a non-oriented and grain oriented electrical steel sheet were measured respectively. In addition, the iron losses due to not only the alternating magnetic fields, but also rotating magnetic fields were measured. These experimentally measured results can evidently be applied to the analysis of iron losses in electrical machines.

A PC based, Low Cost, Tester for Digital Protective Relay (PC 인터페이스에 의한 디지털 보호 계전기의 성능 시험기)

  • Park, Chul-Won;Seo, Jong-Wan;Jung, Ho-Sung;Shin, Myong-Chul;Lee, Bock-Ku
    • Proceedings of the KIEE Conference
    • /
    • 1999.11b
    • /
    • pp.306-308
    • /
    • 1999
  • Recently, several developments of real-time simulators have been reported. But they are very high cost. And then they are difficult to apply for relay testing in small business. This paper presents the structure and performance of a new pc based, low cost, tester to digital protection relays. Fault transients are generated either by simulating signals using EMTP or by recorded fault signals.

  • PDF

A Study on Safety Evaluation of Wheel Using Roller Rig Tester (주행시험기를 이용한 차륜의 안전성 평가에 관한 연구)

  • Ham, Young Sam
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.32 no.7
    • /
    • pp.591-595
    • /
    • 2015
  • The roller rig tester for safety performance evaluation of wheel derailment is a test facility which can give the test load condition to the test wheel, similar to the actual dynamic condition in actual running condition. This study describes the evaluation result on the durability of the resilient wheel equipped with the ring damper and the damping material, and installed in the half part of a full scaled bogie in combination with the primary spring when it rotates under the dynamic condition. The evaluation result on durability of resilient wheel after load test of 2 million cycles shows that the safety of wheel is not affected by the applied load in visual inspection and nondestructive test, however, in the bolt used for fastening the ring damper to the wheel the loosening was found. Accordingly the use of self-locking nut and washer is recommended.

A study on the comparison in different loading methods for pin-on-disk wear test system (마멸시험기의 하중부과 방법에 대한 비교 연구)

  • 서만식;구영필;조용주
    • Proceedings of the Korean Society of Tribologists and Lubrication Engineers Conference
    • /
    • 1998.04a
    • /
    • pp.335-341
    • /
    • 1998
  • In this study, the dynamic characteritics in various loading methods for wear tester were investigated experimentally. As for the dead-weight, the pneumatic, and the hydraulic method, the load control performance against external disturbances was estimated under the several loading conditions like the different sliding speed, the varied normal load, and the misaligument. The hydraulic loading method showed the most stable loading performance of all the loading methods in the experiment.

  • PDF

Performance of R1234yf and R1234yf/R134a Mixture under Mobile Air-conditioner Operating Conditions (R1234yf와 R1234yf/R134a의 자동차 에어컨 작동 조건에서의 성능 평가)

  • Park, Ki-Jung;Lee, Yo-Han;Choe, Dae-Seong;Jung, Dong-Soo
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.22 no.12
    • /
    • pp.837-844
    • /
    • 2010
  • In this study, performance of R1234yf and R1234yf/R134a mixture is measured on a heat pump bench tester in an attempt to substitute R134a used widely in mobile air conditioners (MACs). The bench tester is equipped with a open type compressor providing a nominal capacity of 3.5 kW. All tests are conducted under the summer cooling and winter heating conditions of 7/4 $5^{\circ}C$ and $-7/41^{\circ}C$ in the evaporator and condenser, respectively. For R1234yf/R134a mixture, measurements are made at 5%, 10%, and 15% of R134a by mass. Test results show that the coefficient of performance (COP) and capacity of R1234yf are up to 2.7% and 4.0% lower than those of R134a, respectively. For R1234yf/R134a mixture, the COP and capacity are up to 3.9% lower and 3.6% higher than those of R134a. For R1234yf and R1234yf/R134a mixture, the compressor discharge temperature is $4.1{\sim}6.7^{\circ}C$ lower than that of R134a while the amount of charge is reduced up to 11% as compared to R134a. 90%R1234yf/10%R134a is a better refrigerant than pure R1234yf in that it is less flammable and more compatible with existing R134a system. Based upon the results, it is concluded that R1234yf and R1234yf/R134a mixture are long term environmentally friendly solutions to mobile air-conditioners due to their excellent environmental properties with acceptable performance.

A Study on the Problem of Tester for the Field Inspection of the Photoelectric Smoke Detector (광전식연기감지기 현장점검기기의 문제점에 관한 연구)

  • Kim, Shi-Kuk;Yuk, Hyun-Dai;Yang, Seung-Hyun;Jee, Seung-Wook;Lee, Chun-Ha
    • Fire Science and Engineering
    • /
    • v.23 no.4
    • /
    • pp.137-144
    • /
    • 2009
  • This paper was studied on the problem of field inspection tester of the photoelectric type smoke detector. The experiment objects were chosen 3 type's testers such as A type (incense), B type (dimethylpolysiloxane), C type (mixtures of hydrocarbon) which were used for performance checking of the photoelectric type smoke detector for the fire protection. The experimental methods were used reliability verification experiment, performance verification experiment and performance change of fire detector by smoke component. It was confirmed through the experiment that the testers had problems of smoke concentration condition and wind velocity condition and smoke component. Consequently, this paper verified that the field inspection testers of the photoelectric type smoke detector had problems in the inspection of fire protection.

An Evaluation of Creeping habit in Various Progenies of Red Fescue (Festuca rubra L.) -III. Top-Cross Progeny Performance (잔디용 김의털의 후대검정(後代檢定)에 의한 포복습성(匍匐習性)에 관(關)한 연구(硏究) -제(第)III보(報). Top교잡(交雜)에 의한 후대검정(後代檢定))

  • Kim, Dal Uog;Kim, In Seob
    • Current Research on Agriculture and Life Sciences
    • /
    • v.5
    • /
    • pp.12-18
    • /
    • 1987
  • This study was performed to investigate the creeping habit in top-cross progeny, and to determine the relationship among the major agronomic characters in the top-cross progeny testing based on the The The conclusions of simple correlation coefficients. the study were summarized as follows ; The creeping type crossed with the non-creeping tester was the greatest in width and seed yield. For all three characters, the creeping type crossed with the non-creeping tester and the non-creeping type crossed with the creeping tester were greater than any other combination. The top-cross method was desirable for the study of general and specific combining ability. The sensitivity of the tester to differentiate the creeping and non-creeping types was better when a non-creeping tester was used.

  • PDF

Performance of Heat Pumps Charged with R170/R290 Mixture (R170/R290 혼합냉매 적용 히트펌프 성능 평가)

  • Park, Ki-Jung;Lee, Cheol-Hee;Jung, Dong-Soo
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.20 no.9
    • /
    • pp.590-598
    • /
    • 2008
  • In this study, performance of R170/R290 mixtures is measured on a heat pump bench tester in an attempt to substitute R22. The bench tester is equipped with a commercial hermetic rotary compressor providing a nominal capacity of 3.5kW. All tests are conducted under the summer cooling and winter heating conditions of $7/45^{\circ}C$ and $-7/41^{\circ}C$ in the evaporator and condenser respectively. During the tests, the composition of R170 is varied from 0 to 10% with an interval of 2%. Test results show that the coefficient of performance (COP) and capacity of R290 are up to 15.4% higher and 7.5% lower than those of R22 for both conditions respectively. For R170/R290 mixture, the COP decreases and the capacity increases with an increase in the amount of R170. The mixture of 4%R170/96%R290 shows the similar capacity and COP as those of R22. For the mixture, the compressor discharge temperature is $16{\sim}30^{\circ}C$ lower than that of R22. There is no problem with mineral oil since the mixture is mainly composed of hydrocarbons. The amount of charge is reduced up to 58% as compared to R22. Overall, R170/R290 mixture is a good long term 'drop-in' candidate to replace R22 in residential air-conditioners and heat pumps.