• Title/Summary/Keyword: Performance Test Equipment

Search Result 998, Processing Time 0.025 seconds

Reliability Evaluation Technique for Electrical Distribution Networks Considering Planned Outages

  • Hu, Bo;He, Xiao-Hui;Cao, Kan
    • Journal of Electrical Engineering and Technology
    • /
    • v.9 no.5
    • /
    • pp.1482-1488
    • /
    • 2014
  • The reliability evaluation of the electrical distribution networks (EDN) requires sufficient consideration of the effects of planned outages. The planned outages of the EDN can be divided, by outage models and their effects on the reliability into two major categories: by equipment and by feeder. After studying the characteristics of different categories of planned outages, this paper expands the classification of load points by outage time from 4 types to 7 types and defines corresponding reliability parameters for the different types. By using the section algorithm, this paper proposes a reliability evaluation technique of EDN considering equipment random failures and two categories of planned outages. The proposed technique has been applied to the RBTS-BUS6 test system and some practical EDNs in China. The study results demonstrate that the proposed technique is of higher practical value and can be used for evaluating the reliability performance of EDN more efficiently considering the planned outages.

Damage Detection and Damage Quantification of Temporary works Equipment based on Explainable Artificial Intelligence (XAI)

  • Cheolhee Lee;Taehoe Koo;Namwook Park;Nakhoon Lim
    • Journal of Internet Computing and Services
    • /
    • v.25 no.2
    • /
    • pp.11-19
    • /
    • 2024
  • This paper was studied abouta technology for detecting damage to temporary works equipment used in construction sites with explainable artificial intelligence (XAI). Temporary works equipment is mostly composed of steel or aluminum, and it is reused several times due to the characters of the materials in temporary works equipment. However, it sometimes causes accidents at construction sites by using low or decreased quality of temporary works equipment because the regulation and restriction of reuse in them is not strict. Currently, safety rules such as related government laws, standards, and regulations for quality control of temporary works equipment have not been established. Additionally, the inspection results were often different according to the inspector's level of training. To overcome these limitations, a method based with AI and image processing technology was developed. In addition, it was devised by applying explainableartificial intelligence (XAI) technology so that the inspector makes more exact decision with resultsin damage detect with image analysis by the XAI which is a developed AI model for analysis of temporary works equipment. In the experiments, temporary works equipment was photographed with a 4k-quality camera, and the learned artificial intelligence model was trained with 610 labelingdata, and the accuracy was tested by analyzing the image recording data of temporary works equipment. As a result, the accuracy of damage detect by the XAI was 95.0% for the training dataset, 92.0% for the validation dataset, and 90.0% for the test dataset. This was shown aboutthe reliability of the performance of the developed artificial intelligence. It was verified for usability of explainable artificial intelligence to detect damage in temporary works equipment by the experiments. However, to improve the level of commercial software, the XAI need to be trained more by real data set and the ability to detect damage has to be kept or increased when the real data set is applied.

A Study on the Trim and Resistance of Small Catamaran Using Numerical Analysis and a Model Test (수치해석 및 시험을 통한 소형 쌍동선의 종경사 및 저항 연구)

  • Kim, Jung-eun;Oh, Woo-jun;Hong, Chun-beom;Kim, Do-jung
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.24 no.5
    • /
    • pp.591-596
    • /
    • 2018
  • In Designing a Small Ship, the Design of the Trim for Sailing has a great influence on the Stability of the Ship as well as Resistance. The Center of Gravity of a Ship is mostly determined during Initial Design. This Study confirms the Effect of Trim on changes in Vertical Center of Gravity by Numerical Analysis for a Small Catamaran. The Results were examined in a Model test. However, No Model tests were conducted while varying the changes in Vertical Center of Gravity. Nonetheless, Investigation was completed for the Purpose of presenting Vertical Center of Gravity results according to plans for the Trim during Initial Design of a Small Ship. In order to verify the Results of Numerical Analysis, a Comparison with Experimental results was carried out. Alternation of Trim angle and Resistance performance according to changes in the Center of Gravity were studied.

Guideline on Acceptance Test and Commissioning of High-Precision External Radiation Therapy Equipment

  • Kim, Juhye;Shin, Dong Oh;Choi, Sang Hyoun;Min, Soonki;Kwon, Nahye;Jung, Unjung;Kim, Dong Wook
    • Progress in Medical Physics
    • /
    • v.29 no.4
    • /
    • pp.123-136
    • /
    • 2018
  • The complex dose distribution and dose transfer characteristics of intensity-modulated radiotherapy increase the importance of precise beam data measurement and review in the acceptance inspection and preparation stages. In this study, we propose a process map for the introduction and installation of high-precision radiotherapy devices and present items and guidelines for risk management at the acceptance test procedure (ATP) and commissioning stages. Based on the ATP of the Varian and Elekta linear accelerators, the ATP items were checked step by step and compared with the quality assurance (QA) test items of the AAPM TG-142 described for the medical accelerator QA. Based on the commissioning procedure, dose quality control protocol, and mechanical quality control protocol presented at international conferences, step-by-step check items and commissioning guidelines were derived. The risk management items at each stage were (1) 21 ionization chamber performance test items and 9 electrometer, cable, and connector inspection items related to the dosimetry system; (2) 34 mechanical and dose-checking items during ATP, 22 multileaf collimator (MLC) items, and 36 imaging system items; and (3) 28 items in the measurement preparation stage and 32 items in the measurement stage after commissioning. Because the items presented in these guidelines are limited in terms of special treatment, items and practitioners can be modified to reflect the clinical needs of the institution. During the system installation, it is recommended that at least two clinically qualified medical physicists (CQMP) perform a double check in compliance with the two-person rule. We expect that this result will be useful as a radiation safety management tool that can prevent radiation accidents at each stage during the introduction of radiotherapy and the system installation process.

Localization Development of Axial Fan for KM-SAM Multi-function radar (KM-SAM 다기능레이더용 축류형 송풍기 국산화 개발)

  • Lee, Gyeong-Chan;Choi, Young-Ho;Lee, Kowan-Woo;Seo, Dae-Sue
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.2
    • /
    • pp.117-124
    • /
    • 2018
  • This paper describes the localization development of an axial fan for KM-SAM multi-function radar. The multi-function radar, which is constantly affected by the external environment, is a key instrument for detecting and tracking low and medium altitude threat targets. Operating this equipment smoothly requires a fan for controlling the internal temperature and humidity. Presently, all such fans are imported. To solve these problems, localization development research was proposed. The development of localization includes analysis of requirements through review of related technical reports such as original equipment and system equipment specification, prototype design, and verification of design requirement through performance test and environmental test. The study results are described. The blower consisted of an axial fan with guide vanes and the motor was designed to generate a maximum airflow of 970 CFM and a wind pressure of 4.8 IWG. Six prototypes were manufactured for performance evaluation. In addition, for reliable data acquisition, AC power supply, fan performance tester and data acquisition equipment were designed and tested. All prototypes were verified as having design requirements equal to or better than those of imports.

Robust fuzzy self-organizing control system of temperature environmental test equipment (온도환경 시험장비의 강인한 퍼지 자기조성 제어 시스템)

  • 김인식;윤일선;남세규
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1993.10a
    • /
    • pp.1086-1088
    • /
    • 1993
  • A robust fuzzy self-organizing controller(SOC) is proposed for an environmental temperature chamber. Although fuzzy SOC can improve the performance of nonlinear system, the controller is ineffective to solve the performance degradation owing to the time varying factors. In this paper, we construct the fuzzy SOC with a predictive scheme based on the 386PC. The usefulness of the proposed scheme is shown through the comparison of the PI controller and the fuzzy controller.

  • PDF

The Performance Test of Anti-scattering X-ray Grid with Inclined Shielding Material by MCNP Code Simulation

  • Bae, Jun Woo;Kim, Hee Reyoung
    • Journal of Radiation Protection and Research
    • /
    • v.41 no.2
    • /
    • pp.111-115
    • /
    • 2016
  • Background: The scattered photons cause reduction of the contrast of radiographic image and it results in the degradation of the quality of the image. In order to acquire better quality image, an anti-scattering x-ray gird should be equipped in radiography system. Materials and Methods: The X-ray anti-scattering grid of the inclined type based on the hybrid concept for that of parallel and focused type was tested by MCNP code. The MCNPX 2.7.0 was used for the simulation based test. The geometry for the test was based on the IEC 60627 which was an international standard for diagnostic X-ray imaging equipment-Characteristics of general purpose and mammographic anti-scatter grids. Results and Discussion: The performance of grids with four inclined shielding material types was compared with that of the parallel type. The grid with completely tapered type the best performance where there were little performance difference according to the degree of inclination. Conclusion: It was shown that the grid of inclined type had better performance than that of parallel one.

Seismic Response Amplification Factors of Nuclear Power Plants for Seismic Performance Evaluation of Structures and Equipment due to High-frequency Earthquakes (구조물 및 기기의 내진성능 평가를 위한 고주파수 지진에 의한 원자력발전소의 지진응답 증폭계수)

  • Eem, Seung-Hyun;Choi, In-Kil;Jeon, Bub-Gyu;Kwag, Shinyoung
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.24 no.3
    • /
    • pp.123-128
    • /
    • 2020
  • Analysis of the 2016 Gyeongju earthquake and the 2017 Pohang earthquake showed the characteristics of a typical high-frequency earthquake with many high-frequency components, short time strong motion duration, and large peak ground acceleration relative to the magnitude of the earthquake. Domestic nuclear power plants were designed and evaluated based on NRC's Regulatory Guide 1.60 design response spectrum, which had a great deal of energy in the low-frequency range. Therefore, nuclear power plants should carry out seismic verification and seismic performance evaluation of systems, structures, and components by reflecting the domestic characteristics of earthquakes. In this study, high-frequency amplification factors that can be used for seismic verification and seismic performance evaluation of nuclear power plant systems, structures, and equipment were analyzed. In order to analyze the high-frequency amplification factor, five sets of seismic time history were generated, which were matched with the uniform hazard response spectrum to reflect the characteristics of domestic earthquake motion. The nuclear power plant was subjected to seismic analysis for the construction of the Korean standard nuclear power plant, OPR1000, which is a reactor building, an auxiliary building assembly, a component cooling water heat exchanger building, and an essential service water building. Based on the results of the seismic analysis, a high-frequency amplification factor was derived upon the calculation of the floor response spectrum of the important locations of nuclear power plants. The high-frequency amplification factor can be effectively used for the seismic verification and seismic performance evaluation of electric equipment which are sensitive to high-frequency earthquakes.

Performance Test for the Manganese Nodule Crushing Equipment of the Deep Seabed Mining Robot 'MineRo' (심해저 채광로봇 'MineRo' 망간단괴 파쇄 성능시험)

  • Sung, Ki-Young;Min, Cheon-Hong;Kim, Hyung-Woo;Lee, Chang-Ho;Oh, Jae-Won;Hong, Sup
    • Ocean and Polar Research
    • /
    • v.36 no.4
    • /
    • pp.455-463
    • /
    • 2014
  • This paper presents data from performance tests carried out to assess a manganese nodule crusher. Manganese nodules should be crushed into smaller pieces in order to assure the slurry flow of the lifting system. Both artificial nodules and real manganese nodules are used to evaluate nodule breaking ability of the crusher. The crushing performance of the crusher depends on the flow rate and pressure of the power transmission device. The size of the crushed manganese nodules also depends on the shape of the crushing drum. In this paper, several comparative tests are carried out to evaluate and improve the crushing performance and find the optimal design point of the crusher.

A Study on Track Drive Unit Test and Evaluation for Mini Excavators (소형 굴삭기의 주행구동유니트 시험평가에 관한 연구)

  • Lee, Gi-Chun;Lee, Young-Bum;Choi, Byung Oh
    • Journal of Applied Reliability
    • /
    • v.15 no.3
    • /
    • pp.139-144
    • /
    • 2015
  • Track drive unit adopted in the small sized excavator generally have been used in the construction equipment under the 10 tons as the driving device with forwarding and reversing of excavator. It is required to study the accelerated life test applied by over torque and speed to test the durability life test reflected the many driving modes of small sized excavator and also need to equip the comprehensive performance and life test equipments to do the various performance tests. This study had analyzed the failure modes of the components, and calculated the equivalent loads investigated the used loads in the real field conditions and elicits the acceleration factor adopted in the inverse power model. Also, this study have considered the changes of the acceleration factor and the durability test time in the case of the rotary group and the bearing through analyzing the main failure modes. It was calculated the no failure test time about 2 samples and confidence level 90% and elicited the accelerated life time 720 hours.