• Title/Summary/Keyword: Performance Recovery

Search Result 2,193, Processing Time 0.029 seconds

A Study on Thermal Performance of the Heat Recovery Ventilator used Window (창호적용 배열회수 환기유닛의 열성능평가 연구)

  • Jang, Cheol-Yong;Cho, Soo;Sung, Uk-Joo;Lee, Jin-Sung
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2008.04a
    • /
    • pp.129-134
    • /
    • 2008
  • Generally the window of the building is an objective of mining and having a distant view and also for a circulation it will can open and shut because becomes the structure insulation, the meat detailed drawing it does a very difficult portion, it is. And, recently the use of heat recovery ventilator has increased rapidly for improvement of air Quality and energy saving in building. But, the high efficient heat exchange will be more increasable than water vapors which were only occurred residential active. Purpose of this study is measurement of thermal performance about heat-recovery system integrated window. The result of the window thermal resistance is 1.80 $W/m^2K$ by KS F 2278. Air tightness is 5.96 m3/m2h at 4 Pa by KS F 2292.

  • PDF

Analysis on the Performance Test Results of Heat Pump for the Closed Cooling Water Heat Recovery on Combined Thermal Power Plant (복합화력발전소의 냉각수 배열회수를 위한 히트펌프의 성능평가)

  • Lee, Sung-Ho
    • The KSFM Journal of Fluid Machinery
    • /
    • v.19 no.2
    • /
    • pp.43-48
    • /
    • 2016
  • This study proves successes of Energy Service Company (ESCO) business by heat pump performance test. The purpose of ESCO business is recover investment costs through saving energy from installation of energy reduction facility. The most important technology assessment items are heat recovery and generator output. Experimental result shows that increase quality of heat recovery (11.52Gcal/h), while decrease generator output (0.234kw). In its final analysis, the ESCO business is successful according to our data.

A Study on the Performance of Paper Heat Exchanger for Exhaust Heat Recovery (배기열 회수용 종이 열교환기의 성능에 관한 연구)

  • Yoo, Seong-Yeon;Chung, Min-Ho;Choi, Jae-Ho;Kwon, Hwa-Kil;Lee, Chun-Woo;Lee, Ki-Seong
    • 유체기계공업학회:학술대회논문집
    • /
    • 2003.12a
    • /
    • pp.245-250
    • /
    • 2003
  • In order to control indoor air quality and save energy, it is needed to install a suitable ventilation system equipped with heat exchanger for heat recovery. The purpose of this research is to find the performance of paper heat exchanger for exhaust heat recovery, which exchanges latent heat as well as sensible heat. Experimental apparatus comprises heat exchanger model, constant temperature and humidity chamber, fan and measurement systems for temperature, pressure and flow rate. Thermal performance and pressure loss of the paper heat exchanger are measured and compared at various air velocities and outdoor conditions. Experimental results show that paper heat exchanger can recover $50{\sim}70%$ of the enthalpy difference between supply and exhaust air.

  • PDF

High Performance and Low Cost Single Switch Current-fed Energy Recovery Circuits for AC Plasma Display Panels

  • Han Sang-Kyoo;Youn Myung-Joong
    • Journal of Power Electronics
    • /
    • v.6 no.3
    • /
    • pp.253-263
    • /
    • 2006
  • A high performance and low cost single switch current fed energy recovery circuit (ERC) for an alternating current (AC) plasma display panel (PDP) is proposed. Since it is composed of only one power switch compared with the conventional circuit consisting of four power switches and two large energy recovery capacitors, the ERC features a simpler structure and lower cost. Furthermore, since all power switches can be switched under soft switching operating conditions, the proposed circuit has desirable merits such as increased reliability and low switching loss. Specifically, there are no serious voltage notches across the PDP with the aid of gas discharge current compensation, which can greatly reduce the current stress of all inverter switches, and provide those switches with the turn on timing margin. To confirm the validity of proposed circuit, its operation and performance were verified on a prototype for 7-inch test PDP.

A Study on the Performance of Heat Recovery Ventilators for Apartment Houses (공동주택용 폐열회수형 환기장치의 성능에 관한 측정 연구)

  • Chang, Hyun-Jae;Hong, Seok-Jin
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.20 no.1
    • /
    • pp.26-34
    • /
    • 2008
  • Heat recovery ventilator(HRV) is recommended to improve indoor air quarlity (IAQ) and energy conservation in apartment houses. Recently, in Korea, HRV is produced from many manufacturers. However, there have been not so many experiences to apply HRV in apartment houses and verification on the performance such as heat exchange efficiency, carry-over rate, internal leakage, etc. have not been carried out sufficiently. So in this study, fan performance, heat exchange efficiency, air leakage, internal exhaust leakage, external leakage and sound level of HRV were examined for selected HRV models under domestic and international standard. Results of performance test, there were need to improve latent heat exchange efficiency and sound level of HRV.

Prediction of Performance in heat regenerator with spheres (구형축열체를 이용한 축열기의 성능예측)

  • 조한창;조길원;이용국
    • Proceedings of the Korea Society for Energy Engineering kosee Conference
    • /
    • 2003.11a
    • /
    • pp.299-304
    • /
    • 2003
  • Heat regenerator occupied by regenerative materials improves thermal efficiency of regenerative combustion system through the recovery of sensible heat of exhaust gases. By using one-dimensional two-phase fluid dynamics model, the unsteady thermal flow of regenerators with spherical particles were numerically analyzed to evaluate performance of ratio of waste heat recovery and temperature efficiency and to suggest optimized conditions of heat regenerator. It is predicted that exhaust gases temperature at regenerator outlet of 3.5$\times$10$^{6}$ kcal/hr heat regenerator is even lower than design condition and ratio of waste heat recovery is 75.8%.

  • PDF

Comparative Study on a Single Energy Recovery Circuits for Plasma Display Panels (PDPs)

  • Yi, Kang-Hyun;Choi, Seong-Wook;Moon, Gun-Woo
    • Proceedings of the KIPE Conference
    • /
    • 2007.07a
    • /
    • pp.159-162
    • /
    • 2007
  • Comparative study on a low cost sustaining driver with single and dual path energy recovery circuits for plasma display panels (PDPs) is shown in this paper. The cost of PDPs has been still high and about half of the cost has been occupied by driving circuit. A simple sustaining driver is proposed to reduce the cost and size of driving circuit. The proposed driver has small number of devices and reactive components and there are two methods for charging and discharging PDPs such as single and dual path energy recovery circuits. A comparative research on two-types of energy recovery path is practiced to evaluate performance. As a result, the dual energy recovery path circuit has low power consumption, low surge current and high performance. To verify those results, experiment will be shown with 42-inch HD panel.

  • PDF

Recovery over Time of Production Performance and Biological Functions of Laying Hens after Withdrawal Toxic Levels of Dietary Roxarsone

  • Wu, Chean-Ping;Tsay, Shiow-Min;Chiou, Peter Wen-Shyg;Chen, Kuo-Lung
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.19 no.1
    • /
    • pp.48-54
    • /
    • 2006
  • Roxarsone (3-nitro-4-hydroxyphenylarsonic acid) has been used as feed additives in poultry industries to improve production and control coccidiosis. The effect of high dietary levels of Roxarsone (ROX) on the performance and function of internal organs and the kinetics of recovery as well as its after-effects were examined in laying hens. The inclusion rates of ROX were 0, 100, 200, 300, and 400 mg per kg feed. Inclusion up to 200 mg did not show any adverse effects (p>0.05), whereas in the 300 and 400 mg groups, significant effects, particularly in the latter, were observed for three weeks after ROX addition (p<0.05). Recovery of the physical appearance occurred soon after ROX addition was withdrawn. Recovery of performance and internal organs, however, appeared to be dependent on the amount of residual ROX in the body; as the amount of ROX decreased, the toxic effect of ROX also decreased. In the third week after the withdrawal of ROX, complete recovery was observed in the lower dosage groups (100 or 200 mg groups) (p>0.05), whereas in the higher dosage groups (300 or 400 mg groups), recovery took at least five weeks; when complete recovery was observed in egg production and in liver weight (p>0.05). On the other hand, ROX might have damaged the liver and other tissues. The recovery of liver weight was probably due to accumulation of fatty particles rather than repair. It appeared, therefore, there were little after-effects of ROX on the hen's physical appearance, but some internal organs were probably damaged.

Development of a Set of Data for Verifying Partition Recovery Tool and Evaluation of Recovery Tool (파티션 복구 도구 검증용 데이터 세트 개발 및 도구 평가)

  • Park, Songyee;Hur, Gimin;Lee, Sang-jin
    • Journal of the Korea Institute of Information Security & Cryptology
    • /
    • v.27 no.6
    • /
    • pp.1397-1404
    • /
    • 2017
  • When a digital forensic investigation is conducted on a damaged storage medium, recovery is performed using a recovery tool. But the result of each recovery tool is different depending on the tools. Therefore, it is necessary to identify and use the performance and limitations of the tool for accurate investigation. In this paper, we propose a scenario considering the disk recognition type such as MBR, GPT and the structural characteristics of FAT32 and NTFS filesystem to verify the performance of the partition recovery tool. And then We validate the existing tools with the data set built on the scenarios.

Implementation of Blind Source Recovery Using the Gini Coefficient (Gini 계수를 이용한 Blind Source Recovery 방법의 구현)

  • Jeong, Jae-Woong;Song, Eun-Jung;Park, Young-Cheol;Youn, Dae-Hee
    • The Journal of the Acoustical Society of Korea
    • /
    • v.27 no.1
    • /
    • pp.26-32
    • /
    • 2008
  • UBSS (unde-determined blind source separation) is composed of the stages of BMMR (blind mixing matrix recovery) and BSR (blind source recovery). Generally, these two stages are executed using the sparseness of the observed data, and their performance is influenced by the accuracy of the measure of the sparseness. In this paper, as introducing the measure of the sparseness using the Gini coefficient to BSR stage, we obtained more accurate measure of the sparseness and better performance of BSR than methods using the $l_1$-norm, $l_q$-norm, and hyperbolic tangent, which was confirmed via computer simulations.