• Title/Summary/Keyword: Performance Recovery

Search Result 2,206, Processing Time 0.031 seconds

A Study on The Performance of Ventilation and Maintaining Thermal Environment for a Combined Type Diffuser (급·배기 일체형 디퓨저의 환기 및 온열환경 유지성능에 대한 연구)

  • Lim, Seok-Young;Chang, Hyun-Jae
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.28 no.6
    • /
    • pp.232-241
    • /
    • 2016
  • Installing a ventilator for an apartment house composed of over 100 dwelling units was mandated in 2006 to improve indoor air quality. In the case of mechanical ventilators, the air change rate is kept stable, however 68% of dwellers do not operate their ventilator because of an increased electrical bill and noise. In the case of natural ventilators, the former problems are settled, but there are concerns about cold draught and an increase of heating/cooling cost. Authors are developing a heat recovery type natural ventilator which is a natural ventilator equipped with total heat recovery element, and it is expected that those problems of mechanical ventilator and natural ventilator are resolved by this. The combined type diffuser of this study is an under developed fit to the heat recovery type natural ventilator above. There are no standards to evaluate the performance for this type of diffuser. Due to this issue this study investigated the performance of the ventilation and maintained a thermal environment for the combined type diffuser by comparing it with existing diffusers. The results revealed that the performances of the combined type of diffusers showed different features from the existing ones, and was estimated to be high enough in the performances above.

A Recovery Scheme of SSD-based Databases using Snapshot Log (스냅샷 로그를 사용한 SSD 기반 데이터베이스 복구 기법)

  • Lim, Seong-Chae
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.19 no.4
    • /
    • pp.85-91
    • /
    • 2019
  • In this paper, we propose a new logging and recovery scheme that is suited for the high-performance transaction processing system base on flash memory storage. The proposed scheme is designed by considering flash's I/O characteristic of asymmetric costs between page update/read operations. That is, we substitute the costly update operation with writing and real-time usage of snapshot log, which is for the page-level physical redo. From this, we can avoid costly rewriting of a dirty page when it is evicted form a buffering pool. while supporting efficient revery procedure. The proposed scheme would be not lucrative in the case of HDD-based system. However, the proposed scheme offers the performance advance sush as a reduced number of updates and the fast system recovery time, in the case of flash storage such as SSD (solid state drive). Because the proposed scheme can easily be applied to existing systems by saving our snapshot records and ordinary log records together, our scheme can be used for improving the performance of upcoming SSD-based database systems through a tiny modification to existing REDO algorithms.

Performance Test for High Efficient Heat Pump System using Seawater Heat Source and Exhaust Energy (해수열원 및 폐열이용 고성능 열펌프 시스템 성능실험)

  • 최광일;오종택;오후규
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.15 no.12
    • /
    • pp.979-986
    • /
    • 2003
  • The performance characteristics of heating and cooling operation for a heat pump system using seawater heat source and exhaust energy are presented. The heat pump system is made of a waste heat recovery system and a vapor compression refrigeration system. The working fluid is R-22. The heat pump system COPs are measured during heating and cooling operation modes, and the resultant COPs were 9.7 and 7.9, respectively, which are three times higher than those of the heat pump itself. Therefore, the performance of the heat pump system using exhaust energy is excellent compared to that of a general heat pump. The experimental data can be effectively used for the design of the high efficient heat pump using a seawater heat source.

Parametric Study of Subscale Ejector for Pressure Recovery of Chemical Lasers (화학레이저 압력회복을 위한 축소형 이젝터의 성능변수)

  • Kim Sehoon;Kim Hyungjun;Kwon Sejin
    • Proceedings of the KSME Conference
    • /
    • 2002.08a
    • /
    • pp.135-138
    • /
    • 2002
  • High-speed ejection of burnt gases from the resonator cavity is essential for performance optimization of the chemical laser system. Additionally, to maintain the population of lasing species at a level for maximum optical power, the pressure within the cavity must be of order of 10 torr. In the present study, a small-scale ejector was designed and built for parametric study of its performance. High-pressure air was used as a motive gas. Measurements include schlieren visualization and pressure distribution trace near the ejector nozzle and along the diffuser downstream of the ejector. preliminary tests showed performance of the ejector is a function of parameters including mass flow rate and stagnation pressure of the motive gas, ejector nozzle area ratio, throat area of the diffuser downstream of the ejector.

  • PDF

Fouling Reduction Characteristics of a Fluidized Bed Heat Exchanger for Flue Gas Heat Recovery (연도가스 열회수용 순환유동층 열교환기의 오염저감특성)

  • 이금배;전용두
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.16 no.8
    • /
    • pp.770-777
    • /
    • 2004
  • Fouling and cleaning tests are performed for a uniquely designed 7,000 ㎉/hr fluidized bed heat exchanger for exhaust gas heat recovery. Fuel rich condition is maintained in the combustor for a limited time period to generate soot that is to be deposited on the heat transfer surfaces (fouling) and 600 Um glass beads are circulated inside the heat exchanger system for cleaning and enhancing the heat transfer performance. According to the present experimental study, performance degradation mode could be monitored and the effect of particle circulation on the heat transfer improvement could be identified. Through the present study, it is demonstrated that circulating particles contribute not only to the fouling reduction in gas side, but also to the heat transfer enhancement of the unit, while other possible aging factors including water side corrosion seemed to contribute to the accumulated performance deterioration.

Error Recovery Technique for Improving Reliability of Embedded Systems

  • Son, Sunghoon
    • Journal of the Korea Society of Computer and Information
    • /
    • v.22 no.6
    • /
    • pp.1-8
    • /
    • 2017
  • In this paper, we propose a fault tolerance technique which enables embedded systems to run without interruption while its operating system and tasks fail. In order to improve reliability, the proposed scheme makes an embedded system run as a virtual machine on virtual machine monitor. It also prepares a contingency virtual machine at which periodical backups of the embedded system are saved. When an error occurs in the main virtual machine, the corresponding standby virtual machine takes a role of the main virtual machine and continues its operation. Especially such backups and switches of virtual machines are performed with minor performance degradation by manipulating page table entries in virtual machine monitor. By conducting performance evaluation studies, we show that the proposed scheme makes embedded system robust against errors while it does not degrade the performance of the system significantly.

Flash Memory Shadow Paging Scheme Using Deferred Cleaning List for Portable Databases (휴대용 데이터베이스를 위한 지연된 소거 리스트를 이용하는 플래시 메모리 쉐도우 페이징 기법)

  • Byun Si-Woo
    • Journal of Information Technology Applications and Management
    • /
    • v.13 no.2
    • /
    • pp.115-126
    • /
    • 2006
  • Recently, flash memories are one of best media to support portable computer's storages in mobile computing environment. We propose a new transaction recovery scheme for a flash memory database environment which is based on a flash media file system. We improved traditional shadow paging schemes by reusing old data pages which are supposed to be invalidated in the course of writing a new data page in the flash file system environment. In order to reuse these data pages, we exploit deferred cleaning list structure in our flash memory shadow paging (FMSP) scheme. FMSP scheme removes the additional storage overhead for keeping shadow pages and minimizes the I/O performance degradation caused by data page distribution phenomena of traditional shadow paging schemes. We also propose a simulation model to show the performance of FMSP. Based on the results of the performance evaluation, we conclude that FMSP outperforms the traditional scheme.

  • PDF

Effect of CO in Anode Fuel on the Performance of Polymer Electrolyte Membrane Fuel Cell (수소연료 중 일산화탄소의 고분자전해질 연료전지에 대한 영향)

  • Kwon, Jun-Taek;Kim, Jun-Bum
    • Journal of Hydrogen and New Energy
    • /
    • v.19 no.4
    • /
    • pp.291-298
    • /
    • 2008
  • Carbon monoxide(CO) is one of the contamination source in reformed hydrogen fuel with an influence on performance of polymer electrolyte membrane fuel cell(PEMFC). The studies of CO injection presented here give information about poisoning and recovery processes. The aim of this research is to investigate cell performance decline due to carbon monoxide impurity in hydrogen. Performance of PEM fuel cell was investigated using current vs. potential experiment, long time(10 hours) test, cyclic feeding test and electrochemical impedance spectra. The concentrations of carbon monoxide were changed up to 10 ppm. Performance degradation due to carbon monoxide contamination in anode fuel was observed at high concentration of carbon monoxide. The CO gas showed influence on the charge transfer reaction. The performance recovery was confirmed in long time test when pure hydrogen was provided for 1 hour after carbon monoxide had been supplied. The result of this study could be used as a basis of various reformation process design and fuel quality determination.

Adjusting the Retry Limit for Congestion Control in an Overlapping Private BSS Environment

  • Park, Chang Yun
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.8 no.6
    • /
    • pp.1881-1900
    • /
    • 2014
  • Since 802.11 wireless LANs are so widely used, it has become common for numerous access points (APs) to overlap in a region, where most of those APs are managed individually without any coordinated control. This pattern of wireless LAN usage is called the private OBSS (Overlapping Basic Service Set) environment in this paper. Due to frame collisions across BSSs, each BSS in the private OBSS environment suffers severe performance degradation. This study approaches the problem from the perspective of congestion control rather than noise or collision resolution. The retry limit, one of the 802.11 attributes, could be used for traffic control in conjunction with TCP. Reducing the retry limit causes early discard of a frame, and it has a similar effect of random early drops at a router, well known in the research area of congestion control. It makes the shared link less crowded with frames, and then the benefit of fewer collisions surpasses the penalty of less strict error recovery. As a result, the network-wide performance improves and so does the performance of each BSS eventually. Reducing the retry limit also has positive effects of merging TCP ACKs and reducing HOL-like blocking time at the AP. Extensive experiments have validated the idea that in the OBSS environment, reducing the retry limit provides better performance, which is contrary to the common wisdom. Since our strategy is basically to sacrifice error recovery for congestion control, it could yield side-effects in an environment where the cost of error recovery is high. Therefore, to be useful in general network and traffic environments, adaptability is required. To prove the feasibility of the adaptive scheme, a simple method to dynamically adjust the value of the retry limit has been proposed. Experiments have shown that this approach could provide comparable performance in unfriendly environments.

The performance of a heat pump with 3-piping system at various charging conditions (3관식 시스템 히트펌프의 충전량 변화에 따른 성능 특성에 관한 연구)

  • Song, In-Sik;Choi, Jong-Min;Joo, Young-Ju;Chung, Hyun-Joon;Kang, Hoon;Kim, Yong-Chan
    • Proceedings of the SAREK Conference
    • /
    • 2008.06a
    • /
    • pp.288-293
    • /
    • 2008
  • The cooling load in winter is significant in many commercial buildings and hotels because of the usage of office equipments and the high efficiency of wall insulation. The development of a multi-heat pump that can cover heating and cooling simultaneously for each indoor unit is required. In this study, the performance of a multi-heat pump with 3-piping system was investigated as a function of refrigerant charge and its performance was analyzed in cooling mode, heating mode, and heat recovery mode. COP in the heating or cooling mode showed little dependence on refrigerant charge at overcharge conditions, while those were strongly dependent on refrigerant charge at undercharge conditions and outdoor inlet temperature. In the heat recovery mode, the performance of the system was very sensitive to charge amount at all conditions. Optimum charge amount in the heat recovery mode was 14% lower than that in the cooling mode at the standard condition because the refrigerant only passed the indoor units. It is required to store the excessive refrigerant charge in a storage tank to optimize the system performance at operating modes.

  • PDF