• 제목/요약/키워드: Performance Diagnostic Program

검색결과 61건 처리시간 0.021초

Evaluation of Rapid Diagnostics for Plasmodium falciparum and P. vivax in Mae Sot Malaria Endemic Area, Thailand

  • Chaijaroenkul, Wanna;Wongchai, Thanee;Ruangweerayut, Ronnatrai;Na-Bangchang, Kesara
    • Parasites, Hosts and Diseases
    • /
    • 제49권1호
    • /
    • pp.33-38
    • /
    • 2011
  • Prompt and accurate diagnosis of malaria is the key to prevent disease morbidity and mortality. This study was carried out to evaluate diagnostic performance of 3 commercial rapid detection tests (RDTs), i.e., Malaria Antigen Pf/Pan$^{TM}$, Malaria Ag-Pf$^{TM}$, and Malaria Ag-Pv$^{TM}$ tests, in comparison with the microscopic and PCR methods. A total of 460 blood samples microscopically positive for Plasmodium falciparum (211 samples), P. vivax (218), mixed with P. falciparum and P. vivax (30), or P. ovale (1), and 124 samples of healthy subjects or patients with other fever-related infections, were collected. The sensitivities of Malaria Ag-Pf$^{TM}$ and Malaria Antigen Pf/Pan$^{TM}$ compared with the microscopic method for P. falciparum or P. vivax detection were 97.6% and 99.0%, or 98.6% and 99.0%, respectively. The specificities of Malaria Ag-Pf$^{TM}$, Malaria Ag-Pv$^{TM}$, and Malaria Antigen Pf/Pan$^{TM}$ were 93.3%,98.8%, and 94.4%, respectively. The sensitivities of Malaria Ag-Pf$^{TM}$, Malaria Antigen Pf/Pan$^{TM}$, and microscopic method, when PCR was used as a reference method for P. falciparum or P. vivax detection were 91.8%, 100%, and 96.7%, or 91.9%,92.6%, and 97.3%, respectively. The specificities of Malaria Ag-Pf$^{TM}$, Malaria Ag-Pv$^{TM}$, Malaria Antigen Pf/Pan$^{TM}$, and microscopic method were 66.2%, 92.7%, 73.9%, and 78.2%, respectively. Results indicated that the diagnostic performances of all the commercial RDTs are satisfactory for application to malaria diagnosis.

Radiation attenuation and elemental composition of locally available ceramic tiles as potential radiation shielding materials for diagnostic X-ray rooms

  • Mohd Aizuddin Zakaria;Mohammad Khairul Azhar Abdul Razab;Mohd Zulfadli Adenan;Muhammad Zabidi Ahmad;Suffian Mohamad Tajudin;Damilola Oluwafemi Samson;Mohd Zahri Abdul Aziz
    • Nuclear Engineering and Technology
    • /
    • 제56권1호
    • /
    • pp.301-308
    • /
    • 2024
  • Ceramic materials are being explored as alternatives to toxic lead sheets for radiation shielding due to their favorable properties like durability, thermal stability, and aesthetic appeal. However, crafting effective ceramics for radiation shielding entails complex processes, raising production costs. To investigate local viability, this study evaluated Malaysian ceramic tiles for shielding in diagnostic X-ray rooms. Different ceramics in terms of density and thickness were selected from local manufacturers. Energy Dispersive X-ray Fluorescence (EDXRF) and X-ray Fluorescence (XRF) characterized ceramic compositions, while Monte Carlo Particle and Heavy Ion Transport code System (MC PHITS) simulations determined Linear Attenuation Coefficient (LAC), Half-value Layer (HVL), Mass Attenuation Coefficient (MAC), and Mean Free Path (MFP) within the 40-150 kV energy range. Comparative analysis between MC PHITS simulations and real setups was conducted. The C3-S9 ceramic sample, known for homogeneous full-color structure, showcased superior shielding attributes, attributed to its high density and iron content. Notably, energy levels considerably impacted radiation penetration. Overall, C3-S9 demonstrated strong shielding performance, underlining Malaysia's potential ceramic tile resources for X-ray room radiation shielding.

신경회로망을 적용한 가스터빈 엔진의 성능진단 연구 (A Study on Performance Diagnostics of a Gas Turbine Engine Using Neural Network)

  • 공창덕;고성희;기자영;강명철
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2003년도 제21회 추계학술대회 논문집
    • /
    • pp.267-270
    • /
    • 2003
  • 본 연구에서는 신경회로망을 이용한 가스터빈 엔진의 지능형 성능 진단 컴퓨터 프로그램을 개발하였다. 최근에는 엔진 손상을 분석하는데 있어서 주요 구성품의 가스 경로를 실시간 모니터링(monitoring)하는 가스경로해석(GPA, Gas Path Analysis)방법이 사용되고 있다. 그러나 엔진손상의 형태나 정도가 다양하고 복잡하기 때문에 가스경로해석 접근법만 가지고서는 엔진의 손상상태를 모두 모니터링하기란 쉽지 않다. 따라서 이 문제를 해결하기 위해 학습과 진단을 할 수 있는 신경회로망을 적용하였다. 본 연구에서는 PT6A-62 터보프롭 엔진의 진단에 1개의 은닉층을 갖는 역전파 신경회로망(BPN, Back Propagation Neural Network)이 제안되었다.

  • PDF

마이크로파 레플렉토메터리를 이용한 KSIAR 플라즈마 밀도분포 재구성에 관한 연구 (Study on the Reconstruction of KSTAR Plasma Density Profiles Using Microwave Reflectometry)

  • 노영수
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제54권8호
    • /
    • pp.365-370
    • /
    • 2005
  • Microwave diagnostics have been widely utilized to measure the important parameters of high temperature and high density plasmas. Reflectometry is known as a promising microwave diagnostic which has a number of merits to measure electron density profiles. In the KSTAR device, X-mode FM reflectometry is planned to measure the plasma density profiles. FM reflectometry is required to extract phase information on raw mixer IF signals, thereby obtaining time-of-flight of reflectometry signals. It is known that the data analysis method is crucial to determine the performance of FM reflectometry In fact, there are several analysis programs which have been utilized in various FM systems. Since each program was developed for a specific device, however, it is difficult to directly apply it to a different reactor like the KSTAR device. It is necessary, therefore, to develop a data analysis program for the KSTAR FM reflectometry. In this paper, complex digital demodulation (CDM) and wavelet transformation are examined in terms of the performance of density profile reconstruction. For the comparison of both methods, FM reflectometry signals are generated on the basis of assumed profiles and the interaction of the X-mode wave and the plasma. In order to see how well both methods work under various conditions, three types of profiles are assumed and noise effects are included. As a result, both methods work well under the condition of gentle density gradient and small noise level. As density gradient becomes steeper and noise level gets higher. the reconstruction performance of wavelet is better than that of CDM.

거리 기반 유사도 측정을 통한 유방 초음파 영상의 내용 기반 검색 컴퓨터 보조 진단 시스템에 관한 연구 (A Study of CBIR(Content-based Image Retrieval) Computer-aided Diagnosis System of Breast Ultrasound Images using Similarity Measures of Distance)

  • 김민정;조현종
    • 전기학회논문지
    • /
    • 제66권8호
    • /
    • pp.1272-1277
    • /
    • 2017
  • To assist radiologists for the characterization of breast masses, Computer-aided Diagnosis(CADx) system has been studied. The CADx system can improve the diagnostic accuracy of radiologists by providing objective information about breast masses. Morphological and texture features were extracted from the breast ultrasound images. Based on extracted features, the CADx system retrieves masses that are similar to a query mass from a reference library using a k-nearest neighbor (k-NN) approach. Eight similarity measures of distance, Euclidean, Chebyshev(Minkowski family), Canberra, Lorentzian($F_2$ family), Wave Hedges, Motyka(Intersection family), and Cosine, Dice(Inner Product family) are evaluated by ROC(Receiver Operating Characteristic) analysis. The Inner Product family measure used with the k-NN classifier provided slightly higher performance for classification of malignant and benign masses than those with the Minkowski, $F_2$, and Intersection family measures.

Pattern Matching을 이용한 유방영상의 미세 석회화 검출 (Detection of Mammographic Microcalcifications by Pattern Matching)

  • 양윤석;김은경;김덕원
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1997년도 춘계학술대회
    • /
    • pp.68-71
    • /
    • 1997
  • The early detection of brest cancer is clearly a key ingredient for any strategy designed to reduce breast cancer mortality. Microcalcification(MCC) is one of the primary signatures to discriminate between normal and cancerous tissue. The detection and locating procedures can be automated by digital image processing, however, MCCs have various sizes, shapes, and intensity levels in film images, so it is difficult to find accurate locations and sizes. Firstly, we made quantitative analysis for many characteristic features of mammograms that can be used to segment MCCs from normal tissues. Secondly, we developed algorithms proper to segmentation like pattern matching. The performance was evaluated with TP and FP rates.

  • PDF

CT Assessment of Myocardial Perfusion and Fractional Flow Reserve in Coronary Artery Disease: A Review of Current Clinical Evidence and Recent Developments

  • Chun-Ho Yun;Chung-Lieh Hung;Ming-Shien Wen;Yung-Liang Wan;Aaron So
    • Korean Journal of Radiology
    • /
    • 제22권11호
    • /
    • pp.1749-1763
    • /
    • 2021
  • Coronary computed tomography angiography (CCTA) is routinely used for anatomical assessment of coronary artery disease (CAD). However, invasive measurement of fractional flow reserve (FFR) is the current gold standard for the diagnosis of hemodynamically significant CAD. CT-derived FFRCT and CT perfusion are two emerging techniques that can provide a functional assessment of CAD for risk stratification and clinical decision making. Several clinical studies have shown that the diagnostic performance of concomitant CCTA and functional CT assessment for detecting hemodynamically significant CAD is at least non-inferior to that of other routinely used imaging modalities. This article aims to review the current clinical evidence and recent developments in functional CT techniques.

방사선방어용앞치마(Apron)의 차폐율과 균일성 측정을 통한 성능평가 연구 (A study on performance evaluation of Apron by shielding rate and uniformity)

  • 유세종;임창선;심규란
    • 대한안전경영과학회지
    • /
    • 제17권1호
    • /
    • pp.103-109
    • /
    • 2015
  • In this study, we quantitatively analyzed the data by measuring the radiation shielding rate and uniformity in order to evaluate the performance of an Apron. In addition, storage conditions were also evaluated. The uniformity measurement was performed by evaluating the Apron DICOM images using a PACS program. The experiment was intended for 51 Aprons being used in three hospitals in the Daejeon area. The radiation shielding rate and uniformity were measured per lead equivalent for 0.25 mmPb, 0.35 mmPb, and 0.5 mmPb. As a result, the higher lead equivalents were, the greater differences in the non-uniformity between the top part and the bottom part became (p=0.020). In all hospitals, regarding the non-uniformity of four places in Aprons, all showed statistically significant differences (p<0.01). The average value of the transmitted radiation dose showed less difference (p=0.005) in the bottom right than in the upper right but was statistically significant. There have been no marks of manufacturing date or the date of purchase in the Apron.

The method of in-situ ASTR method diagnosing wall U-value in existing deteriorated houses - Analysis of influence of internal surface total heat transfer rate -

  • Kim, Seo-Hoon;Kim, Jong-Hun;Jeong, Hakgeun;Song, Kyoo-dong
    • KIEAE Journal
    • /
    • 제17권4호
    • /
    • pp.41-48
    • /
    • 2017
  • Purpose : Currently, 25% of the domestic energy consumption structure is used as building energy, and more than 18% of this energy is consumed in the residential. Accordingly, various efforts and policies that can save energy of the building is being performed. The various researchers are conducting research to diagnose the thermal performance of existing buildings. This study is to apply in the field of precision thermal insulation performance diagnostic method for thermal performance analysis of existing detached house in Seoul, Gangreung, Gyeongju, Pohang. And this paper is analyzed quantitatively measure the existing detached house energy performance. Method: Research methodology analyzed the thermal performance over the Heat Flow Meter method by applying the measurement process and method by applying the criteria of ISO 9869-1 & ASTR method. In this study, the surface heat transfer coefficient was calibrated by applying indoor surface heat transfer resistance with reference to ISO 6946 standard. The measurement error rate between the HFM diagnosis method and the ASTR diagnosis method was reduced and the measurement reliability was obtained through measurement method error verification. Result : As a result of the study, the thermal performance vulnerable parts of the building were quantitatively analyzed, and presented for methods which can be improved capable of efficient energy use buildings.

AAPM CT 성능 평가용 팬텀을 이용한 전산화단층촬영의 영상 평가를 위한 정도관리 사례 연구 (Case Study of Quality Assurance for MDCT Image Quality Evaluation Using AAPM CT Performance Phantom)

  • 장근조;권대철
    • 한국콘텐츠학회논문지
    • /
    • 제7권7호
    • /
    • pp.114-123
    • /
    • 2007
  • 전산화단층촬영(CT)은 영상의학에서 매우 유용한 검사의 진단법으로 적절한 정도관리에 의한 영상의 평가가 필요하다. CT의 정도관리 항목에서 영상의 질을 결정하는 중요한 요소를 위해 AAPM CT 팬텀으로 영상검사를 수행하였다. 정도관리 평가항목은 "특수의료장비의 설치 및 운영에 관한 규칙"에서 정한 기준으로 물의 CT 감약계수, 노이즈, 균일도, 공간분해능, 대조도 분해능, 절편 두께, 인공물 존재 유무를 평가하였다. 획득한 영상은 규칙의 합격기준에 충족하였다. CT 영상의 질을 최적으로 유지하기 위해서는 지속적으로 팬텀 및 임상검사를 통해 영상의 질을 평가하기 위해 정도관리를 시행하여야 한다.