• Title/Summary/Keyword: Performance Certification

Search Result 608, Processing Time 0.034 seconds

Performance analysis of tunnel scanning system based on Japanese performance evaluation system (일본 성능평가 제도기반 터널 스캐닝 시스템 성능 분석)

  • Chulhee Lee;Jaemo Kang;Donggyou Kim
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.25 no.4
    • /
    • pp.331-344
    • /
    • 2023
  • The performance of the existing tunnel scanning system was analyzed through the post-evaluation of NETIS (New Technology Information System) and Inspection Support Technology Performance Catalog. Suggestions for improvement and development direction of the tunnel scanning system were deduced. As new technology of Japan gave priority to providing user-centered information, it was possible to objectively compare and analyze the characteristics of various tunnel scan systems through post-evaluation of NETIS and standard test methods in the Inspection Support Technology Performance Catalog. Construction New Technology of Korea was centered on suppliers of technology certification, making it impossible to objectively compare the performance of tunnel scanning systems. The performance was compared and evaluated indirectly by comparing the specifications of the camera, which is a core device of Japan's tunnel scanning system. For the future development of tunnel scanning systems, high-resolution and fast exposure performance of cameras and corresponding high-intensity lighting devices are required. For this purpose, it is necessary to make an experimental environment in which the performance of the camera and lighting can be analyzed indoors.

The developing direction of korean gas pressure welding machine (철근 가스압접공법 활성화를 위한 한국형 철근자동가스압접기 기술개발방향)

  • Seo, Deok-Seok;Song, Ki-Jun;Hwang, Kee-Tae;You, Beong-Taek
    • Journal of the Korea Institute of Building Construction
    • /
    • v.5 no.3 s.17
    • /
    • pp.131-138
    • /
    • 2005
  • The study is focused on the settling the developing direction of korean gas pressure welding machine which can be applied in korean construction sites with moderate and high performance. Gas pressure welding is more economical and has good performances than other steel bar jointing methods, as arc welding and mechanical joint etc. Therefore in Japan, the gas pressure welding, which has less loss of steel bars and low performance of joints, when connecting the D29 and thicker steel bars, Is one of the typical connection of steel reinforcement. But in Korea, the gas pressure welding method is not widely used caused by the shortage of skilled workers, and this situation in Korea can not be solved in short period. The training of the skilled workers takes long period(around $6\~10$ years), and there is no certification system for gas pressure welding. So to activate the gas pressure welding in Korea, the development of the automatic gas pressure welding machine is necessary, which gives regular performance of the steel bar joints and can be operated by not sufficient skilled workers. The automatic gas pressure welding machine was developed in Japan, but this machine has many problems when applied in korean construction sites. Therefore, it is necessary to develop a korean automatic gas pressure welding machine to overcome this problems. To develop korean automatic gas pressure welding machine, the problems, which shows when applied in korean construction sites, need to be investigated. According to the investigation, counterproposals are presented for the pragmatical development of the korean automatic gas pressure welding machine.

A Study on the Factors which Influenced the Performance of Urban Family Planning Health Personnels' Function - Around the FP health personnels in the Seoul metropolitan city- (도시 가족계획요원의 직무수행에 영향을 미치는 요인에 관한 연구 -서울특별시 동단위 가족계획카드관리요원을 중심으로-)

  • Lee, Myoung-Sook;Moon, Hyung-Wha
    • Journal of Korean Public Health Nursing
    • /
    • v.3 no.2
    • /
    • pp.143-156
    • /
    • 1989
  • This study was done in order to analyze the factors which influenced the performance level of urban family planning health personnels' task. Interview survey was done during the period May, 1989. Interviewee were 130 family planning health personnels among total of 140 family planning health personnels in Seoul metropolitan city area. The internal consistency reliability was tested by Cronbach’s Alpha and the construct validity of the survey tool was tested by Factor analysis. Multiple stepwise regression analysis was used to identify major factors influenced to perform family planning health personnels' task. The results of this study were summarized as follows: 1. The internal consistency reliability was high and very significant (Cronbach's Alphs=0.8445, p<0.0000). 2. The construct validity was high and very significant. This analysis was contained 5 factors; registering and keeping of eligible woman records, health educating for FP & MCH, referral for vasectomy and tubal ligation and loop, supplying contraceptive appliances, sending moved-out eligible woman records. 3. Among a total of 15 contents of their functions recording of daily report and monthly report (76.2%), classifying and keeping of records(66.2%), registering of eligible woman records(60.85ti), distribution of leaflets and pamplets(54.6%), counselling & supervision about family planning(53.8%) were actively performed. Sending moved-out eligible woman records(60.8%), health education for community people(49.2%), referring contraceptors' side-effects were poorly performed. 4. The factors which influenced the performance level of urban family planning health personnels' function were age, marital status, educational level, certification, number of residents, number of eligible women, job car-eer, work responsibility, job satisfaction knowledge, position, cooperation of community people, cooperation of Dong Office, cooperation of Health Center. These 14 variables were able to explain job function from 21.4% of follow-up care of contraceptor to 9.1% of classifying & keeping of eligible woman records.

  • PDF

The Effects of IT Service Management upon IT Service Management Performance: An Empirical Approach (IT 서비스 관리가 IT 서비스 관리 성과에 미치는 영향에 관한 실증 연구)

  • Kim, Min-Sun;Kim, Seung-Yoon;Lee, Seung-Joon;Lee, Jae-Beom
    • The Journal of Information Systems
    • /
    • v.18 no.1
    • /
    • pp.1-24
    • /
    • 2009
  • Recently many companies have increased their investment in IT because they are increasingly interested in taking advantage of IT and they recognized that it was a very important strategic resource that any organization should manage. That means that the members of a company or an organization realized the importance of IT specialists' coordinating and working in partnership with the business employees to ascertain the high quality and productivity through IT services. While the company looks at IT cost reduction, there is a pressure from users for more support and service from IT departments. That means IT service providers have to offer improved service quality at reasonable cost. To solve the contradictory problem, this paper proposes the application of IT service management. If the IT service management is implemented properly, an organization can attain the tangible and intangible results which are profitable and effective. In Korea, studies on IT service management have focused only on getting a certification and development issues, and there are few papers which accomplished empirical studies. From the viewpoint of Resource-based theory, this study reviews the definition of IT service management and its elements. It has demonstrated empirically how IT service management can have an impact on IT service management performance. As a result, IT service management plays a role in adding and improving the practical use and efficiency of IT service management. In conclusion, this study contributes to support and show the critical point of the previous literatures about IT service management and offers the new practical implications for business sectors.

Development and Simulation Verification of Operation System for Mobile ESS Test Equipment (ESS 이동형 시험장비용 운영시스템의 개발과 모의검증)

  • Shin, Je-Seok;Han, Hyun-Gyu;Kim, Jin-Tae;Lee, Seung-Min;Park, Chan-Wook;Lim, Geon-Pyo
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.67 no.3
    • /
    • pp.168-174
    • /
    • 2018
  • The performance test for 376MW ESS for frequency regulation currently operating in 13 substations is conducted based on the test procedure in the first and second steps. In the first step, components of ESS is moved to the certification authority where the test equipment is located in order to be proceeded with the test. In the second step, the performance test is conducted manually for the ESS equipments installed on site using the movable measurement equipment, and thus it can only be performed on some limited test items and requires a lot of time and manpower. Therefore, mobile test equipment for ESS(MOTES) is being developed that can perform automatically more test items for ESS in the field using the MOTES, and reduce manpower and time. To do this, an algorithm and a prototype of the operating system(MOS) are also being developed that can control MOTES automatically. In this paper, a development of the MOS prototype is introduced and then a simulation is performed to verify the prototype and its algorithm before the field demonstration.

Development of Communication Module for a Mobile Integrated SNS Gateway (모바일 통합 SNS 게이트웨이 통신 모듈 개발)

  • Lee, Shinho;Kwon, Dongwoo;Kim, Hyeonwoo;Ju, Hongtaek
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.39B no.2
    • /
    • pp.75-85
    • /
    • 2014
  • Recently, mobile SNS traffic has increased tremendously due to the deployment of smart devices such as smart phones and smart tablets. In this paper, mobile integrated SNS gateway is proposed to cope with massive SNS traffic. Most of mobile SNS applications update the information with individual connection to the corresponding servers. The proposed gateway integrates these applications. It is for reducing SNS traffic caused by continuous data request and improving the mobile communication performance. The key elements of the mobile integrated SNS gateway are the synchronization, cache and integrated certification. The proposed protocol and gateway system have implemented on the testbed which deployed on the real network to evaluate the performance of the proposed gateway. Finally, we present the caching performance of gateway system implementation.

Case Study : Application of Specific Evaluation Criteria For Safety Circuit Design of EN ISO 13849-1 (사례 연구 : EN ISO 13849-1의 안전회로 설계를 위한 구체적 평가 기준의 적용)

  • Jung, Hwansuk;Lee, Dongju
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.41 no.1
    • /
    • pp.94-101
    • /
    • 2018
  • With the development of industrial technology and science, production and manufacturing facilities have been enhanced and improved, and the importance of the safety of workers has also been regulated and limited by various safety management methods. As a way to secure the safety of the workers from the production facility, the fail-safe and fool-proof methods are now being applied. Any possible insecure behavior and unsafe conditions can be removed by adopting the standards and specifications that are now secure the safety of workers and equipment. This research analyzes EN ISO 13849-1 international and European standards during CE certification. In order to secure acceptable reduced risks, the risk assessment process of ISO 12100 and the processes for reducing its risk are applied. In the current ISO 13849-1 standard, the criteria for the required performance level PLr (Required Performance Level) for the applicable risk and safety functions through the risk assessment are subjective and not subdivided. Therefore, the evaluation criteria are likely to cause judge's judgement error due to qualitative judgement. This research focuses on evaluation and acceptable performance level setting for the safety circuit of the equipment. We propose an objective and specific evaluation criteria to secure safety, and the proposed evaluation criteria are applied to the case study of the safety circuit for the equipment. In order to secure the safety of the entire safety circuit, the improvement of the MTTFd and DC level related to the SRP/CS (Safety-Related Parts of Control Systems)' lifetime is required for the future research.

A Study for Performance Estimation Standard and Standardization of u-IT Convergence Equipment (u-IT Convergence 기기의 성능평가기준과 표준화 연구)

  • Chun, Woo-Sung;Park, Dea-Woo;Lee, Sang-Ick;Kim, Eung-Sik;Kim, Hong
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2009.10a
    • /
    • pp.457-460
    • /
    • 2009
  • u-IT Convergence appliances study and are developed in communication by development of u-IT technology, broadcasting, portal, contents, equipment and all fields of business such as solution. This treatise presents valuation basis of, economic performance, administration sex etc. by temperature, pressure, own, storehouse, gas, justice for humidity sensors and valuation basis that define u-IT Convergence, and sense information u-IT Convergence devices and terminal. Also, studied standardization standard of u-IT Convergence network appliance that follow in valuation basis for u-IT Convergence devices. Is going to contribute establish value as estimation product that equip stability and authoritativeness through correct certification assessment for technological development and appliances on Ubiquitous information-oriented society through this research and accomplish standardization.

  • PDF

Integrated Navigation Filter Design for Trains Considering the Mounting Misalignment Error of the IMU

  • Chae, Myeong Seok;Cho, Seong Yun;Shin, Kyung Ho
    • Journal of Positioning, Navigation, and Timing
    • /
    • v.10 no.3
    • /
    • pp.179-187
    • /
    • 2021
  • To estimate the location of the train, we consider an integrated navigation system that combines Inertial Navigation System (INS) and Global Navigation Satellite System (GNSS). This system provides accurate navigation results in open sky by combining only the advantages of both systems. However, since measurement update cannot be performed in GNSS signal blocked areas such as tunnels, mountain, and urban areas, pure INS is used. The error of navigation information increases in this area. In order to reduce this problem, the train's Non-Holonomic Constraints (NHC) information can be used. Therefore, we deal with the INS/GNSS/NHC integrated navigation system in this paper. However, in the process of installing the navigation system on the train, a Mounting Misalignment Error of the IMU (MMEI) inevitably occurs. In this case, if the NHC is used without correcting the error, the navigation error becomes even larger. To solve this problem, a method of easily estimating the MMEI without an external device is introduced. The navigation filter is designed using the Extended Kalman Filter (EKF) by considering the MMEI. It is assumed that there is no vertical misalignment error, so only the horizontal misalignment error is considered. The performance of the integrated navigation system according to the presence or absence of the MMEI and the estimation performance of the MMEI according to the method of using NHC information are analyzed based on simulation. As a result, it is confirmed that the MMEI is accurately estimated by using the NHC information together with the GNSS information, and the performance and reliability of the integrated navigation system are improved.

A Comparison of Performance Evaluations of Reusable Masks (다회용 마스크 유형에 따른 성능 비교연구)

  • Ryu, Hoe-Jin;Park, Won-Hee;Lee, Chun-Yeong;Jeong, Seon-Ok;Choi, Hee-Jin;Lee, Jeong-Mi;Hwang, In-Sook;Shin, Yong-Seung
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.32 no.1
    • /
    • pp.53-63
    • /
    • 2022
  • Objectives: This study was designed to evaluate the filtration efficiency, inhalation resistance, and liquid resistance of commercial reusable masks in comparison to the performance of KF-AD masks (reference masks). Methods: Thirty-six masks were purchased from an online market. Filtration efficiency and inhalation resistance were determined in the same manner as in MFDS certification testing, respectively using TIL/IL & Filter Test 1300S (SFP Services, UK) and Breathing Resistance Analyzer DA2001 (Lambda Ray, South Korea). Results: Most of the filtration efficiencies found for the 19 masks were far lower than the test standard for KF-certified masks. Four masks met KF94 and three masks even met KF80. Most inhalation resistances were also much lower than the standard, with many almost one-half of the standard. In addition, all the masks except KF-AD masks did not pass the liquid resistance test. Conclusions: Although most of the filtration efficiency performance results found in this study for the reusable masks, which emerged as an alternative, were lower than the standard for health masks, multi-use masks can be used with a replacement filter inserted.