An Empirical Survey on the Current Practices of Environmental Performance Evaluation in Korean Firms (우리 나라 기업의 환경성과평가 실태 연구)

  • 성백서
    • Journal of Korean Society for Quality Management
    • /
    • v.30 no.3
    • /
    • pp.203-236
    • /
    • 2002
  • Environmental Performance Evaluation(EPE) is a key process of Corporate Environmental Management. This paper presents the results of an empirical survey on the status of current practices in EPE of Korean firms. Based on a corporate environmental management(CEM) model, which is initially developed by Hibbitt and Kamp-Roelands(2001) and modified in terms of EPE, the survey is peformed on the population of Korean firms, which are composed of firms certified as "environmentally friendly" by Korean government and/or certified under Is014001, and compares its results with those of Europe's. Although the relatively low response rate and some methodological limitations makes us be cautious about the interpretation, the results shows many interesting aspects of the current states of Korean firms' EPE practices. That is, the levels of EPE implementation in the environmentally-leading companies of Korea are almost the same as that of European companies, I. e., in the-final-part-of-developing-stage (3rd stage) level of the CEM model. It is also shown that as In Europe's case, Korean firms are also moving slower in external relationships than in internal control and management, are more developed in the parameters like environmental policy, Internal control, Information system, which are requirements of certification under Is014001, than in parameters like life cycle analysis and full cost accounting, which requires more research efforts, etc.orts, etc.

Development of Performance Measure Indices using TRL: Focused on the National Medical Device R&D Projects (TRL을 이용한 R&D 프로젝트 성과 평가지표 개발: 의료기기 사업을 중심으로)

  • Lee, Man-Pyo;Jung, Mi-Jin;Choi, Gyung-Hyun
    • Journal of Biomedical Engineering Research
    • /
    • v.38 no.3
    • /
    • pp.89-94
    • /
    • 2017
  • In order to improve national competitiveness through technological research and development, the government puts in R&D budget every year and manages to improve the R&D results. Accordingly, various R&D project management methods have applied for successful advancement of technology and product. TRL is a measurement system developed by NASA to assess the maturity of technology since the 1970s. To apply medical device, the characteristics such as regulation, clinical trials are considered as a significant influence. In this study, we would like to derive PMI(performance measures index) for medical device R&D projects by using TRL and stage-gate model. As a result of this study, it is possible to use the PMI for decision making and evaluation in the R&D projects and believed that the objectivity can be ensured by the approval or certification of regulatory authority.

A Study on Evaluation of the Building Energy Rating depending on the Thermal Performance of Balcony Window with Low-E glazing (로이유리 발코니 창호의 단열성능에 따른 공동주택 건축물 에너지효율등급 평가 연구)

  • Lee, Na-Eun;Ahn, Byung-Lip;Jang, Cheol-Yong;Leigh, Seung-Bok
    • Journal of the Korean Solar Energy Society
    • /
    • v.32 no.2
    • /
    • pp.58-63
    • /
    • 2012
  • As the exterior of building has been considered one of th important parts, the use of glass that is suitable to express various appearances gets raised. However, windows have 6~7times lower insulating performance than insulated walls. Lately, highly efficient windows are required as the needs for reduction of energy consumption come to the force. Therefore, Nowadays more people use cooling systems in summer, more the use of Low-E glazing is increasing. Because it is good to block Solar Radiant Energy which can cause much of heat loss while cooling system is working. This study measures U-value of the double Low-E glazing window and commonly used single Low-E glazing window. And then the effect of each window on the efficiency rating has been analyzed applying to the certification system of the building energy efficiency rating which has implemented.

A Study on the Evaluation of the Building Energy Efficiency in Accordance with the Shapes of the Apartment Unit Plans (아파트 단위세대 평면 형태에 따른 건물에너지효율 평가)

  • Kim, Chang Sung;Seo, Kyung Wook
    • KIEAE Journal
    • /
    • v.13 no.4
    • /
    • pp.55-62
    • /
    • 2013
  • Korea Government have carried out various policies to reduce the energy consumption that cause the global warming and environmental pollution. Energy consumption of buildings in Korea has reached 24% of total energy quantities and energy consumption of apartment has been continuously increasing. It has executed the building energy efficiency rating system and energy performance assessments and certification systems have been in force to save energy consumption of buildings. Therefore, this study tried to asset the energy performance of apartment according to the shapes of unit plan, and then to evaluate the energy performance of apartment according to altering balcony area into living area in the unit plan of apartment and thus, to present the effective unit plan to reduce the energy consumption. According to the results, in case of standard unit plan, the 3Bay and 4Bay unit plans showed more effective energy consumption than the 2Bay unit plan, respectively, 5%, 6%, and in case of extended unit plan, respectively, 2%, 5%. Compared the energy efficiencies of the standard unit plan to the extended unit plan, the standard one showed more effective energy consumption than the extended one, respectively, 2% in case of the 2Bay and 4Bay unit, 5% of the 3Bay unit.

Developing an Integrated Evaluation Technology for Energy- and Cost-Efficient Building Design Based on BIM in the Real-time Manner

  • Park, Jae Wan;Lee, Yun Gil
    • Architectural research
    • /
    • v.16 no.3
    • /
    • pp.93-100
    • /
    • 2014
  • Existing BIM(Building Information Modeling) based energy evaluation tools cannot be utilized enough for the potential performance of BIM because most of them have not provided the integrated model for energy evaluation, assessment of the material, cost of the construction, and so on. This research aims to propose and develop a new application, EcoBIM, to support an integrated evaluation of the energy and cost efficiencies of the design alternatives within the design process. The proposed application functions as a BIM-based evaluation system that calculates energy-savings performance as well as the construction cost of the alternatives at the design stage. This study mainly focuses on the possibilities of developing the proposed technology. We also suggest an advanced design process using the proposed system, corresponding to changes of national regulations in Korea. This study deduce that EcoBIM can allow architects to make suitable decisions regarding energy- and cost-efficient designs. The proposed design process will allow architects not only to check the eco-friendly performance of design alternatives but also predict the operation cost in a certain period in the future. EcoBIM can prevent large-scale design changes required to obtain environmental certification and enable the owner to make an informed decision about the initial investment of construction according to the result of the analysis of the energy requirement at the design stage.

Continuity of BLS Training Effects in Nursing Students (간호대학생의 기본심폐소생술에 대한 교육효과의 지속성)

  • Kim, Hye-Sook;Choi, Eun-Young
    • The Journal of Korean Academic Society of Nursing Education
    • /
    • v.18 no.1
    • /
    • pp.102-110
    • /
    • 2012
  • Purpose: The purpose of this study was to evaluate the effects of BLS training in nursing students and their retention period. Methods: The participants were 48 nursing students enrolled in M University in Mokpo. Data were collected from September, 2009 through September 2010. Nursing students were tested for their knowledge, attitude, confidence before, immediately after, 4 weeks after, 8 weeks after, 6 months after, and 1 year after BLS training. In addition, their knowledge and skill of cardiopulmonary resuscitation were tested 5 times. Data were analyzed using the SPSS/PC 12.0 statistical program Results: Knowledge, attitude and confidence were significantly increased immediately after compared to before BLS training. Knowledge and confidence 6 months after, and attitude, performance ability and technical precision for ventilation and compression 4 weeks after BLS training were significantly decreased compared to immediately after. Conclusion: Overall retention of BLS training effects among nursing students, without reinforcement, decreases significantly after six months following initial training. BLS training in nursing students should be repeated every six months, especially performance training of BLS should be repeated every 4 weeks. In addition, to maintain the knowledge and skills of BLS, appropriate renewal time of certification and improvement of training programs are necessary.

Legal Aspects for Quality Evaluation Standard of Plant Variety and Seed (식물 품종 및 종자의 품질평가 기준에 대한 규정현황)

  • 최근진
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.47
    • /
    • pp.200-215
    • /
    • 2002
  • There are some international standards and organization controling the quality characteristics of varieties and seeds such as UPOV, OECD, ISTA, AOSA. The National List system to check variety performance such as quality characteristics of plant varieties and seeds was established by each countries. The UPOV (International Union for the Protection of New varieties of Plant) regulates the requirement of plant variety protection that is distinctness (D), uniformity (U), stability (S) (here in after called DUS), Novelty and Denomination, and some quality characteristics are used to examine the requirement of plant variety protection by each crops. OECD (Organization for Economic Cooperation Development) seed scheme regulates the seed certification for seed trade between countries. ISTA (International Seed Testing Association) and AOSA(Association for Official Seed Analyst) regulates the seed analysis standard and methods. Most of the countries in Europe has the National List system, which check the value for cultivation and use(VCU), that is to say, variety performance such as yield, quality and stress to environment. All the seeds should be enlisted in the National List before sell the seed in their country. All the quality characteristics checked variety performance are for instance, amylose and amylopectin content in rice, molting quality, $\beta$-glucan, protein in barley, protein and sugar content in soybean, sugar and amylopectin content in corn etc. Conditions for the protection of new variety of plant are DUS. Quality characteristics may be the important characteristics and used to check DUS in crop by crop. It is very important to develop a new characteristics and establish standard method fur examine the VCU and DUS test for each crop.

Comparative analysis of Korean and foreign energy performance assessment methods for residential buildings (국내외 주거용 건물의 에너지성능 평가방법 비교분석)

  • Song, Seung-Yeoung;Koo, Bo-Kyoung;Lee, Beung-In;Song, Jin-Hee;Kim, Yeon-Hee
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2009.11a
    • /
    • pp.191-198
    • /
    • 2009
  • Many Countries are making nationwide efforts to reduce the energy consumption which causes greenhouse gas emissions and global warming problems. Energy performance assessments and certification systems have been in force to save energy consumption of residential buildings, and are anticipated to have strong effects through the systems. Korean Building Energy Efficiency Rating System is in its early stages and is considered that the additional upgrade is needed for the accurate assessment. Thus, in this study, the assessment methods of the Building Energy Efficiency Rating System of Korea and the SAP2005 of UK were compared and energy requirements of an actual residential building were calculated with two assessment methods, respectively. The strengths and shortcomings of two systems were analyzed and a way of improving Korean system was suggested.

  • PDF

Evaluating on the Environmental performance of Incheon Free Economic Zone constructions (인천경제자유구역 건축물의 친환경성 평가에 관한 연구)

  • Park, Tae Bum;Kim, Yong-Shik
    • KIEAE Journal
    • /
    • v.10 no.1
    • /
    • pp.91-96
    • /
    • 2010
  • Incheon Free Economic Zone's Songdo Area is a newly constructed city built on land reclaimed from the seaside and the surrounding area. Yeongjong Area is made after Land reclamation between Yeongjong Island and Yongyou Island began in November 1992. The first phase linking these islands to create the Incheon International Airport (phase 1) and the Airport Town Square community was finished in March 2001. However, if we take a look at the overall status of the project as it is carried on at present, it is hard to deny that the project is trapped inside the same legal restrictions as are all other existing cities, which permits Songdo Area and Yeongjong Area to meet only very minimum standards. This study intends to analyze and assess the Incheon Free Economic Zone's Songdo Area and Yeongjong Area of environmentally friendly construction and to rate its current development status, exposing any problems and offering alternative solutions. In this paper, the current state of constructions in Songdo Area and Yeongjong Area were reviewed. Then a quantitative analysis and assessment for the Songdo Area and Yeongjong Area constructions of apartments, complex buildings, office buildings, school facilities, store and hotel facilities were conducted by using green building certification criteria. Finally the synthetic results of environmental performance evaluation for Incheon Free Economic Zone's Songdo Area and Yeongjong Area constructions and follow-up suggestions were described.

The Study to Improve the Insulation Standards for Mechanical Pipes based on Energy Performance (에너지 성능 기반의 기계설비배관 단열기준 개선을 위한 연구)

  • Yun, Hiwon;Ryu, Hyung Kyou
    • Journal of the Korean Society for Geothermal and Hydrothermal Energy
    • /
    • v.17 no.4
    • /
    • pp.28-35
    • /
    • 2021
  • The need for zero-energy building is increasing as a means of actively responding to climate change. Since pipe insulation is a factor that minimizes heat loss of cooling and heating facilities, it is necessary to check pipe insulation standards and prepare improvement plans of preparation for certification of zero energy buildings. In this study, domestic pipe insulation standards were checked to prepare new insulation standards based on energy performance. Through the development of a pipe insulation calculation program, the heat loss according to the insulation thickness of the piping for mechanical facilities was compared and reviewed. As a result, applying the insulation thickness of the KCS standard for the same conditions increased the heat loss by an average of 10% compared to the ASHRAE standard. For this reason, it is necessary to revise the pipe insulation thickness standard in consideration of heat loss due to thermal conductivity and pipe insulation thickness. Using the program in this paper, it is possible to design pipe insulation based on energy performance and help to determine the standard for pipe insulation thickness.