Environmental Performance Evaluation(EPE) is a key process of Corporate Environmental Management. This paper presents the results of an empirical survey on the status of current practices in EPE of Korean firms. Based on a corporate environmental management(CEM) model, which is initially developed by Hibbitt and Kamp-Roelands(2001) and modified in terms of EPE, the survey is peformed on the population of Korean firms, which are composed of firms certified as "environmentally friendly" by Korean government and/or certified under Is014001, and compares its results with those of Europe's. Although the relatively low response rate and some methodological limitations makes us be cautious about the interpretation, the results shows many interesting aspects of the current states of Korean firms' EPE practices. That is, the levels of EPE implementation in the environmentally-leading companies of Korea are almost the same as that of European companies, I. e., in the-final-part-of-developing-stage (3rd stage) level of the CEM model. It is also shown that as In Europe's case, Korean firms are also moving slower in external relationships than in internal control and management, are more developed in the parameters like environmental policy, Internal control, Information system, which are requirements of certification under Is014001, than in parameters like life cycle analysis and full cost accounting, which requires more research efforts, etc.orts, etc.
In order to improve national competitiveness through technological research and development, the government puts in R&D budget every year and manages to improve the R&D results. Accordingly, various R&D project management methods have applied for successful advancement of technology and product. TRL is a measurement system developed by NASA to assess the maturity of technology since the 1970s. To apply medical device, the characteristics such as regulation, clinical trials are considered as a significant influence. In this study, we would like to derive PMI(performance measures index) for medical device R&D projects by using TRL and stage-gate model. As a result of this study, it is possible to use the PMI for decision making and evaluation in the R&D projects and believed that the objectivity can be ensured by the approval or certification of regulatory authority.
As the exterior of building has been considered one of th important parts, the use of glass that is suitable to express various appearances gets raised. However, windows have 6~7times lower insulating performance than insulated walls. Lately, highly efficient windows are required as the needs for reduction of energy consumption come to the force. Therefore, Nowadays more people use cooling systems in summer, more the use of Low-E glazing is increasing. Because it is good to block Solar Radiant Energy which can cause much of heat loss while cooling system is working. This study measures U-value of the double Low-E glazing window and commonly used single Low-E glazing window. And then the effect of each window on the efficiency rating has been analyzed applying to the certification system of the building energy efficiency rating which has implemented.
Korea Government have carried out various policies to reduce the energy consumption that cause the global warming and environmental pollution. Energy consumption of buildings in Korea has reached 24% of total energy quantities and energy consumption of apartment has been continuously increasing. It has executed the building energy efficiency rating system and energy performance assessments and certification systems have been in force to save energy consumption of buildings. Therefore, this study tried to asset the energy performance of apartment according to the shapes of unit plan, and then to evaluate the energy performance of apartment according to altering balcony area into living area in the unit plan of apartment and thus, to present the effective unit plan to reduce the energy consumption. According to the results, in case of standard unit plan, the 3Bay and 4Bay unit plans showed more effective energy consumption than the 2Bay unit plan, respectively, 5%, 6%, and in case of extended unit plan, respectively, 2%, 5%. Compared the energy efficiencies of the standard unit plan to the extended unit plan, the standard one showed more effective energy consumption than the extended one, respectively, 2% in case of the 2Bay and 4Bay unit, 5% of the 3Bay unit.
Existing BIM(Building Information Modeling) based energy evaluation tools cannot be utilized enough for the potential performance of BIM because most of them have not provided the integrated model for energy evaluation, assessment of the material, cost of the construction, and so on. This research aims to propose and develop a new application, EcoBIM, to support an integrated evaluation of the energy and cost efficiencies of the design alternatives within the design process. The proposed application functions as a BIM-based evaluation system that calculates energy-savings performance as well as the construction cost of the alternatives at the design stage. This study mainly focuses on the possibilities of developing the proposed technology. We also suggest an advanced design process using the proposed system, corresponding to changes of national regulations in Korea. This study deduce that EcoBIM can allow architects to make suitable decisions regarding energy- and cost-efficient designs. The proposed design process will allow architects not only to check the eco-friendly performance of design alternatives but also predict the operation cost in a certain period in the future. EcoBIM can prevent large-scale design changes required to obtain environmental certification and enable the owner to make an informed decision about the initial investment of construction according to the result of the analysis of the energy requirement at the design stage.
The Journal of Korean Academic Society of Nursing Education
/
v.18
no.1
/
pp.102-110
/
2012
Purpose: The purpose of this study was to evaluate the effects of BLS training in nursing students and their retention period. Methods: The participants were 48 nursing students enrolled in M University in Mokpo. Data were collected from September, 2009 through September 2010. Nursing students were tested for their knowledge, attitude, confidence before, immediately after, 4 weeks after, 8 weeks after, 6 months after, and 1 year after BLS training. In addition, their knowledge and skill of cardiopulmonary resuscitation were tested 5 times. Data were analyzed using the SPSS/PC 12.0 statistical program Results: Knowledge, attitude and confidence were significantly increased immediately after compared to before BLS training. Knowledge and confidence 6 months after, and attitude, performance ability and technical precision for ventilation and compression 4 weeks after BLS training were significantly decreased compared to immediately after. Conclusion: Overall retention of BLS training effects among nursing students, without reinforcement, decreases significantly after six months following initial training. BLS training in nursing students should be repeated every six months, especially performance training of BLS should be repeated every 4 weeks. In addition, to maintain the knowledge and skills of BLS, appropriate renewal time of certification and improvement of training programs are necessary.
There are some international standards and organization controling the quality characteristics of varieties and seeds such as UPOV, OECD, ISTA, AOSA. The National List system to check variety performance such as quality characteristics of plant varieties and seeds was established by each countries. The UPOV (International Union for the Protection of New varieties of Plant) regulates the requirement of plant variety protection that is distinctness (D), uniformity (U), stability (S) (here in after called DUS), Novelty and Denomination, and some quality characteristics are used to examine the requirement of plant variety protection by each crops. OECD (Organization for Economic Cooperation Development) seed scheme regulates the seed certification for seed trade between countries. ISTA (International Seed Testing Association) and AOSA(Association for Official Seed Analyst) regulates the seed analysis standard and methods. Most of the countries in Europe has the National List system, which check the value for cultivation and use(VCU), that is to say, variety performance such as yield, quality and stress to environment. All the seeds should be enlisted in the National List before sell the seed in their country. All the quality characteristics checked variety performance are for instance, amylose and amylopectin content in rice, molting quality, $\beta$-glucan, protein in barley, protein and sugar content in soybean, sugar and amylopectin content in corn etc. Conditions for the protection of new variety of plant are DUS. Quality characteristics may be the important characteristics and used to check DUS in crop by crop. It is very important to develop a new characteristics and establish standard method fur examine the VCU and DUS test for each crop.
Many Countries are making nationwide efforts to reduce the energy consumption which causes greenhouse gas emissions and global warming problems. Energy performance assessments and certification systems have been in force to save energy consumption of residential buildings, and are anticipated to have strong effects through the systems. Korean Building Energy Efficiency Rating System is in its early stages and is considered that the additional upgrade is needed for the accurate assessment. Thus, in this study, the assessment methods of the Building Energy Efficiency Rating System of Korea and the SAP2005 of UK were compared and energy requirements of an actual residential building were calculated with two assessment methods, respectively. The strengths and shortcomings of two systems were analyzed and a way of improving Korean system was suggested.
Incheon Free Economic Zone's Songdo Area is a newly constructed city built on land reclaimed from the seaside and the surrounding area. Yeongjong Area is made after Land reclamation between Yeongjong Island and Yongyou Island began in November 1992. The first phase linking these islands to create the Incheon International Airport (phase 1) and the Airport Town Square community was finished in March 2001. However, if we take a look at the overall status of the project as it is carried on at present, it is hard to deny that the project is trapped inside the same legal restrictions as are all other existing cities, which permits Songdo Area and Yeongjong Area to meet only very minimum standards. This study intends to analyze and assess the Incheon Free Economic Zone's Songdo Area and Yeongjong Area of environmentally friendly construction and to rate its current development status, exposing any problems and offering alternative solutions. In this paper, the current state of constructions in Songdo Area and Yeongjong Area were reviewed. Then a quantitative analysis and assessment for the Songdo Area and Yeongjong Area constructions of apartments, complex buildings, office buildings, school facilities, store and hotel facilities were conducted by using green building certification criteria. Finally the synthetic results of environmental performance evaluation for Incheon Free Economic Zone's Songdo Area and Yeongjong Area constructions and follow-up suggestions were described.
Journal of the Korean Society for Geothermal and Hydrothermal Energy
/
v.17
no.4
/
pp.28-35
/
2021
The need for zero-energy building is increasing as a means of actively responding to climate change. Since pipe insulation is a factor that minimizes heat loss of cooling and heating facilities, it is necessary to check pipe insulation standards and prepare improvement plans of preparation for certification of zero energy buildings. In this study, domestic pipe insulation standards were checked to prepare new insulation standards based on energy performance. Through the development of a pipe insulation calculation program, the heat loss according to the insulation thickness of the piping for mechanical facilities was compared and reviewed. As a result, applying the insulation thickness of the KCS standard for the same conditions increased the heat loss by an average of 10% compared to the ASHRAE standard. For this reason, it is necessary to revise the pipe insulation thickness standard in consideration of heat loss due to thermal conductivity and pipe insulation thickness. Using the program in this paper, it is possible to design pipe insulation based on energy performance and help to determine the standard for pipe insulation thickness.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.