• Title/Summary/Keyword: Performace Analysis

Search Result 42, Processing Time 0.022 seconds

CFD Application for Design and Development of Centrifugal Compressors (원심압축기의 설계 개발을 위한 CFD의 응용과 전망)

  • Kang Shin-Hyoung
    • 한국전산유체공학회:학술대회논문집
    • /
    • 1995.10a
    • /
    • pp.12-28
    • /
    • 1995
  • CFD techniques are widely used for the design and development of turbomachinery. The design and performance prediction, evaluation of performace and analysis are all important for the successful development of the machinery. The characteristics of the sturcture and performace of the centrifugal compressor are reviewed for the effective application of CFD techniques. The examples of flow calculations through an impeller and a channel diffuser are presented and phenomenological aspects are discussed. The future research topics of CFD area are also suggested.

  • PDF

Adjustable-Performace, Single-Ended Input Double-Balanced Mixer

  • Choi, Jin-Yong;Lee, Kyung-Ho;Lee, Sang-Gug
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.1 no.4
    • /
    • pp.248-252
    • /
    • 2001
  • A noble single-ended input, double-balanced mixer topology is proposed. The mixer incorporates the common-source amplifier input stage with inductive degeneration for impedance matching. The analysis based on simulations shows that the overall performance of the mixer is excellent and is adjustable by varying the input transistor size to give best characteristics for the given linearity specifications.

  • PDF

Performace Improvement of Self-Validating Sensors Using Fuzzy Logic (퍼지 논리를 사용한 Self-Validating 센서의 성능 개선)

  • 나승유;배희종
    • Proceedings of the Korean Institute of Intelligent Systems Conference
    • /
    • 2000.11a
    • /
    • pp.349-352
    • /
    • 2000
  • In case of sensor faults, they can be detected by examining the sensor output values and the typical values of the system. And then the types of the faults are recognized by the analysis of symptoms of faults. If necessary self-validating sensor values are synthesized according to the types of faults, and then they are used for the controller instead of the raw data. In this paper, fuzzy logic is introduced in SEVA sensors to improve the system performance. And then the method is applied to the control of a flexible link system with the sensor fault problems for exact positioning to show the applicability.

  • PDF

The Development of Transient Analysis Model and Performace Analysis of 345[kV] 100[MVA] STATCOM (345[kV] 100[MVA] STATCOM 과도해석 모델 개발 및 동특성 분석)

  • Yoon, Jong-Su
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.25 no.6
    • /
    • pp.28-34
    • /
    • 2011
  • This paper describes the development of the transient analysis model of 345[kV] 100[MVA] STATCOM and the result of the performance analysis. The Korea power utility company, KEPCO began a commercial operation of a 100[MVA] STATCOM(Static synchronous COMpensator) at 345[kV] Migeum substation in Seoul. In order to operate a new control device like STATCOM to the power system, suitable transient model is needed. Therfore, Korea Electric Power Coporation(KEPCO) developed a transient analysis models using EMTDC/PSCAD. The development of this transient analysis model is based on the actual STATCOM S/W algorithm and H/W specification that was provided by its manufacture. Through this model, the transient/dynamic performance of STATCOM at Migeum substation can be analyzed.

Sensitivity Analysis of Shape Design Parameters of a Toque Converter Using Potential Flow (포텐셜 유동 해석을 이용한 토크 컨버터의 형상설계 파라미터들의 민감도 해석)

  • 김준양;이장무;박찬일;임원식
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1994.10a
    • /
    • pp.924-929
    • /
    • 1994
  • In using a performance model of a torque converter determined by its gemetric condition, it is possible that the analysis of two arbitrary converters produces the the same results because of the same value of equivalent parameters despite their different shapes. Therefore, it is necessary to understand the effect of shape factor on dynamic perfomance, and equivalent parameters reoresenting a performace model of a converter should into its defined by the behavior of flow field. In this study, torus flow of a torque converter is changed into its equivalent system defined by the behavior of flow, and govering equations for the system are presented and used for analysis. Equivalent parameters are obtained from the results of flow analysis and are compared with parameters of one dimensional performance model. The influence that shape change of a converter has on the behavior of flow and the equivalent parameters is studied qualitatively.

  • PDF

Performance analysis of a 3 bladed & 5 bladed savonius rotor for wave energy conversion by CFD

  • Zullah, Mohammed Aisd;Prasad, Deepak;Choi, Young-Do;Lee, Young-Ho
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2009.06a
    • /
    • pp.628-629
    • /
    • 2009
  • A variety of technologies have already been developed to capture energy from the ocean waves, this one is simple to construct. Rather then looking at the surface waves, the technique used lets the waters current beneath the waves directly drive the rotors. The novel ocean wave energy convertor consists of savonius rotor which is mounted in the ocillating water column (OWC) chamber. This study investigates the performance of a 3 blade and 5 bladed savonius rotor under same wave condition using commercial CFD code. Initially the performance analysis of savonius type turbine have been carried out with conventional three bladed curved rotors. From the experieneces of the simulations, 5 bladed savonius rotor have been developed and studied. Performace caracteristics of the 5 bladed savonius rotor has been evaluated and the results obgtained are comopared with the conventional three bladed curved rotors.

  • PDF

Kinematic Optimal Design of Excavator with Performance Analysis (굴삭기의 기구학적 최적설계와 성능해석)

  • 한동영;김희국;이병주
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1994.10a
    • /
    • pp.617-622
    • /
    • 1994
  • In this paper, we perform a two-stage, kinematic optimal design for 3 degree-of-freedom excavator system which consists of boom, arm, and bucket. The objective of the first stage is to find the optimal joint parameters which maximize the force-torque transmission ratio between the hydraulic actuator and the rotating joint. The objective of the first stage is to find the optimal link parameters which maximize the isotropic characteristic throughout the workspace. It is illustrated that performances of the optimized excavator are improved compared to those of HE280 excavator, with respect to the described performace index and maximum load handling capacity.

  • PDF

The Elastic-Plastic Contact Analysis of 3D Rough Surface of Nongaussian Height Distribution (비정규 높이분포를 가진 3차원 거친 표면의 탄.소성접촉해석)

  • 김태완;구영필;조용주
    • Proceedings of the Korean Society of Tribologists and Lubrication Engineers Conference
    • /
    • 2001.06a
    • /
    • pp.374-381
    • /
    • 2001
  • Surface roughness plays a significant role in friction, wear, and lubrication in machine components. Most engineering surfaces have tile nogaussian height distrubution. So, in this study, elastic-plastic contact simulations are conducted for not only gaussian surfaces but also nongaussian surfaces. Nongaussian rough surface considering the kurtosis is generated numerically. The contact simulation model takes into account the plastic deformation behaviors of asperities by setting a celing on their contact pressure at material hardness value. It will be shown that the performace variables such as real contact area fraction, plastic area fraction and average gap are sensitive to the characteristics of surface geometry according to kurtosis.

  • PDF