• 제목/요약/키워드: Perfect Switch

검색결과 15건 처리시간 0.029초

Bayes Estimators for Reliablity of a k-Unit Standby System with Perfect Switch

  • Lee, Changsoo;Kim, Keehwan;Park, Youngmi
    • Communications for Statistical Applications and Methods
    • /
    • 제8권2호
    • /
    • pp.435-442
    • /
    • 2001
  • Bayes estimators and generalized ML estimators for reliability of a k-unit hot standby system with the perfect switch based upon a complete sample of failure times observed from an exponential distribution using noninformative, generalized uniform, and gamma priors for the failure rate are proposed, and MSE's of proposed several estimators for the standby system reliability are compared numerically each other through the Monte Carlo simulation.

  • PDF

크로바 스위치를 적용한 10/350 임펄스 회로에서 인덕턴스에 따른 wave tail 특성 (Characteristic of Wave Tail According to Inductance values in 10/350 Impulse Circuit with Crowbar Switch)

  • 조성철;이태형;김기복;엄주홍
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2009년도 제40회 하계학술대회
    • /
    • pp.1416_1417
    • /
    • 2009
  • This paper shows the characteristic of wave tail according to inductance values in 10/$350{\mu}s$ impulse circuit with crowbar switch. The PSpice was used to simulate the 10/$350{\mu}s$ current waveform and lightning current impulse generator was used to generate real current waveform. As a capacitor of condenser bank increases, a virtual front time increases and a time to half-value decreases. To get a perfect 10/$350{\mu}s$ current waveform, we should consider the combination of circuit values of the inductance, capacitance, time difference between trigger pulses and charged voltage of capacitor bank.

  • PDF

전력용 반도체 소자를 적용한 하이브리드 초전도 한류기 동작 신뢰도 향상 (Reliability Enhancement of Hybrid Superconducting Fault Current Limiter adopting Power Electric Device)

  • 심정욱;박권배;임성우;김혜림;이방욱;오일성;현옥배
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제9권3호
    • /
    • pp.57-61
    • /
    • 2007
  • The current limiting characteristics of hybrid SFCL with additional power electronic devices was investigated in order to improve operation reliabilities. The hybrid SFCL developed consists of a superconducting trigger (S/T) part, a fast switch (F/S) module and a current limiting (C/L) part. Although hybrid SFCL had shown a excellent current limiting characteristics, this device was rather vulnerable to the residual arc currents which could exist during fast switch operation. This undesirable arc should be extinguished as quickly as possible in order to implement perfect fault current commutation. So, in order to eliminate the residual arcs between fast switch contacts, the power electronic devices (IGBT or GTO) were connected in series between the S/T part and the interrupter of the F/S module. According to the fault tests conducting with an input voltage of $270\;V_{rms}$ and a fault current of $5\;kA_{rms}$, The power electronic devices could perfectly remove the arc generated between the contacts of the interrupter within 4 ms after the fault occurred. From the test analysis, it was confirmed that the hybrid SFCL could enhance the operation reliability by adopting additional power electronic devices.

Notes on the Comparative Study of the Reliability Estimation for Standby System with Exponential Lifetime Distribution

  • Kim, Hee-Jae
    • Journal of the Korean Data and Information Science Society
    • /
    • 제14권4호
    • /
    • pp.1055-1065
    • /
    • 2003
  • We shall propose maximum likelihood, Bayesian and generalized maximum likelihood estimation for the reliability of the two-unit hot standby system with exponential lifetime distribution that switch is perfect. Each estimation will be compared numerically in terms of various mission times, parameter values and asymptotic relative efficiency through Monte Carlo simulation.

  • PDF

Bayesian Reliability Estimation for a Two-unit Hot Standby System

  • Kim, Hee-Jae;Moon, Young-Gil;Lee, Chang-Soo
    • Journal of the Korean Data and Information Science Society
    • /
    • 제8권1호
    • /
    • pp.31-39
    • /
    • 1997
  • we shall propose some Bayes estimators and some generalized maximum likelihood estimators for reliability of a two-unit hot standby system with perfect switch based upon a complete sample of failure times observed from the exponential model and compare the peformances of the proposed estimators in terms of mean squared error.

  • PDF

Notes on the Comparative Study of the Reliability Estimation for Standby System with Rayleigh Lifetime Distribution

  • Kim, Hee-Jae
    • Journal of the Korean Data and Information Science Society
    • /
    • 제15권1호
    • /
    • pp.239-250
    • /
    • 2004
  • We shall propose maximum likelihood, Bayesian and generalized maximum likelihood estimation for the reliability of the two-unit hot standby system with Rayleigh lifetime distribution that switch is perfect. Each estimation will be compared numerically in terms of various mission times, parameter values and asymptotic relative efficiency through Monte Carlo simulation.

  • PDF

자동물꼬의 개발 (Development of the Automatic Inlet)

  • 정하우;이남호;김성준;최진용;한형근;김대식
    • 한국농공학회지
    • /
    • 제37권1호
    • /
    • pp.49-54
    • /
    • 1995
  • Three types of floating-type automatic inlet were developed for the purpose of reduc- ing farmer's working hours required for water management and saving irrigation water. The point of automation is to use a float within the inlet which is floated and sinked by the ponding depth of paddy field, Thus opens and closes the control gate of irrigation. Suitability of each inlet may depend on production cost, applicability to paddy field condi- tions, and feasibility to farmers, etc. The first model was composed of three parts : chamber for irrigation control gate, chamber for float controlled by ponding depth, and connection bar between the two parts. It was designed to open and close the control gate gradually as the ponding depth drops and rises to a certain level. The second model was designed to improve the weak point of the first model which is the imperfect-closing of gate when it approaches to the end of ir- rigation. A switch-spring was equipped above the connection bar for perfect opening and closing of gate when the ponding depth reaches to a certain level. The third model was designed by combining the two chambers, that is, cut in halves the inlet volume of the above two models. Magnets were equipped above the float for perfect opening and closing gate. The functional experiment for three developed inlets was successfully carried out and the rating curves were derived.

  • PDF

동적 부하 기술을 이용한 1-Tesla 자기공명 영상 시스템용 마이크로 스트립 quadrature coupler 및 고출력 송수신 스위치의 설계 및 제작 (Design and Implementation of Microstrip Quadrature Coupler and High Power Transmitting/Receiving Switch Using Dynamic Loading Technique for 1-Tesal MRI System)

  • 류웅환;이미영;이흥규;이황수;김정호
    • 전자공학회논문지D
    • /
    • 제36D권3호
    • /
    • pp.1-11
    • /
    • 1999
  • 자기공명영상 시스템의 신호 대 잡음 비(SNR, Signal-to-Noise Ratio)를 향상시키기 위해서 quadrature RF 코일을 사용하는 것은 최근의 일반적인 방법이다. 그렇지만 이 때 SNR의 향상을 가져오기 위해서는 완벽한 3dB 커플링과 90°위상차를 가지는 잘 설계된 quadrature coupler가 필수적이다. 또한 RF 여기 주기와 검파 주기 동안 각 포트의 임피던스 정합 조건이 잘 만족되어야 한다. 본 논문에서는 분석과 시뮬레이션 및 제작을 통해 임피던스 부정합 조건(특히,환자)의 영향을 살펴보았고 이의 영향을 최소화하고 시스템의 신뢰성을 향상시키기 위한 회로 기술로 동적 로딩(dynamic loading)을 처음으로 quadrature coupler 와 송수신 스위치 모듈에 적용하는 것을 제안했다. 또한 quadrature coupler와 송수신 스위치 모듈을 마이크로 스트립을 이용해 설계하고 제작 하였다. 결과적으로 자기공명영상 시스템의 SNR은 수신 동적 부하가 없고 불연속 소자로 된 종전 모듈을 사용했을 때보다 시스템의 SNR이 3dB 높아졌다. 또한 이 모듈은 자기공명영상 시스템이의 최대 5kw의 고출력 RF 신호의 처리가 가능하다. 전력 손실과 크기를 고려할 때, 고유전율을 가진 R/Tduroid 6010 기판을 사용하였으며, 시뮬레이션은 Compact Software을 사용 했다.

  • PDF

전자식 모터제어 시스템 개발 (A Development of Electronic Motor Control Systems)

  • 이성환;이석주
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 추계학술대회 논문집 학회본부 A
    • /
    • pp.76-78
    • /
    • 2000
  • The previous MCC's have the demerits of high cost and much manhour for rework because they are impossible for the standardization of products and have many manual connections. The customers require the products which can operate in connection with SCADA system by digitalizing the functions of the current MCC's and are systematized with capability of remote control. To solve these disadvantages and requirements, we developed the Electronic Motor Control System according to starting type for applying to fields based on this. This system has the various functions such as protection, measurement, and communication. Using these functions, it can monitor motor status through communication with the upper system and define the circuit for lower connection cost according to starting type and shorter manufacture period by program. The development of this product results in establishment of competitive structure with domestic competition and perfect automatic monitoring through linkage with SCADA system. In addition, it provides the comparable dominancy of receiving on orders in switch gear and adaptability to change of MCC market in Japan and Europe.

  • PDF

살아있는 집-주거환경 컨트롤 시스템의 스윗치 제안- (A study on the electric switch of Living Space)

  • 인석일
    • 디자인학연구
    • /
    • 제21권
    • /
    • pp.41-52
    • /
    • 1997
  • 건축기술의 발전을 통해 인간이 주거환경을 완벽하게 컨트롤하게 되리라는 꿈이 20세기 이후 전기공학의 발전으로 그 현실화가 가능하게 된다. 1세기동안 시스템의 발전 속에서 디자인은 이제 주변환경과 주거공간, 그리고 시스템과 인간의 관계를 새로이 정립할 개념을 찾고 있다. 현재 시스템의 기술적 한계를 토대로 하여 어떠한 새로운 개념이 가능한지 살펴보고 한 세대 앞선 제품을 제안해본다.

  • PDF