• Title/Summary/Keyword: Percent contrast

Search Result 128, Processing Time 0.025 seconds

The Evaluation of Image Correction Methods for SPECT/CT in Various Radioisotopes with Different Energy Levels (SPECT/CT에서 서로 다른 에너지의 방사성동위원소 사용시 영상보정기법의 유용성 평가)

  • Shin, Byung Ho;Kim, Seung Jeong;Yun, Seok Hwan;Kim, Tae Yeop;Lim, Jung Jin;Woo, Jae Ryong;Oh, So Won;Kim, Yu Kyeong
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.17 no.2
    • /
    • pp.53-58
    • /
    • 2013
  • Purpose: To optimize correction method for SPECT/CT, image quality consisting of resolution and contrast was evaluated using three radioisotopes ($^{99m}Tc$, $^{201}Tl$ and $^{131}I$) and three different correction methods; attenuation correction (AC), scatter correction (SC) and both attenuation and scatter correction (ACSC). Materials and Methods: Images were acquired with a SPECT/CT scanner and a conventional CT protocol with an OESM reconstruction algorithm (2 iterations and 10 subsets). For resolution measurement, fixed radioactivity (2.22 kBq) was infused into a spatial resolution phantom and full width at half maximum (FWHM) was measured using a vendor-provided software. For contrast evaluation, radioactive source with a ratio of 1:8 to background was filled in a Flanged Jaszczak phantom and percent contrast (%) were calculated. All the parameters for image quality were compared with non-correction (NC) method. Results: As compared with NC, image resolution of all three isotopes were significantly improved by AC and ACSC, not by SC. In particular, ACSC showed better resolution than AC alone for $^{99m}Tc$ and $^{201}Tl$. Image contrast of all three radioisotopes in a sphere with the largest diameter were enhanced by all correction methods. ACSC showed the highest contrast in all three radioisotopes, which was the most accurate in $^{99m}Tc$ (85.9%). Conclusion: Image quality of SPECT/CT was improved in all the radioisotopes by CT-based attenuation correction methods, except SC alone. SC failed to improve resolution in any radioisotopes, but it was effective in contrast enhancement. ACSC would be the best correction method as it improved resolution in radioisotopes with low energy levels and contrast in radioisotope with low energy levels. However, in radioisotope with high energy level, AC would be better than ACSC for resolution improvement.

  • PDF

조영제 사용 전${\cdot}$후 불균질 조직 보정 알고리즘에 따른 선량변화에 대한 연구

  • Kim, Ju-Ho;Jo, Jeong-Hui;Lee, Seok;Jeon, Byeong-Cheol;Park, Jae-Il
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.13 no.1
    • /
    • pp.38-46
    • /
    • 2001
  • Purpose : The aim of this study is to investigate the effect of tissue inhomogeneities when appling to contrast medium among Homogeneous, Batho and ETAR dose calculation method in RTP system. Method and Material : We made customized heterogeneous phantom it filled with water or contrast medium slab. Phantom scan data have taken PQ 5000 (CT scanner, Marconi, USA) and then dose was calculated in 3D RTP (AcQ-Plan, Marconi, USA) depends on dose calculation algorithm (Homogeneous, Batho, ETAR). The dose comparisons were described in terms of 2D isodose distribution, percent depth dose data, effective path length and monitor unit. Also dose distributions were calculated with homogeneous and inhomogeneous correction algorithm, Batho and ETAR, in each patients with different clinical sites. Results : Result indicated that Batho and ETAR method gave rise to percent depth dose deviation $1.5{\sim}2.7\%,\;2.3{\sim}3.5\%$ (6MV, field size $10{\times}10cm^2$) in each status with and without contrast medium. Also show that effective path lengths were more increase in contrast status (23.14 cm) than Non-contrast (22.07 cm) about $4.9\%$ or 10.7 mm (In case Hounsfield Unit 270) and these results were similary showned in each patient with different clinical site that was lung. prostate, liver and brain region. Concliusion : In conclusion we shown that the use of inhomogeneity correction algorithm for dose calculation in status of injected contrast medium can not represent exact dose at GTV region. These results mean that patients will be more irradiated photon beam during radiation therapy.

  • PDF

Studies on the Germination Promotion of the Zoysia japonica seeds. (한국잔디(Zoysia japonica Steud.) 종자의 발아촉진에 관한 연구)

  • 전우방
    • Asian Journal of Turfgrass Science
    • /
    • v.1 no.1
    • /
    • pp.30-36
    • /
    • 1987
  • In order to promote the germination of Korean lawn grass(Zoysia japonica Steud.) seeds a gravimetric seed selection with a mixed chemical solution and the germination promotion with KOH treatment were studied and following results were obtained. 1. When immersed into methanol(S.G., 0.7) 14 percent of immature seeds were precipitated. 2. With water (S.G., 1.0) 36.5 percent of mature seeds were submerged. 3. On a mixture of carbon tetrachloride (S.G., 1.6) and ethylether (S.G., 0.7) in a ratio of 4:6 the seed selection was most effective. 4. When treated with KOH solution the germination rate was 71.01 percent in contrast to 6.0 percent of germination without the treatment. 5. As for concentration of KQH solution, 15 percent depressed the germination (46.7 %) whereas above 20 % the germination rate was gradually increased (79.32 %) up to 40 percent of concentration where the concentration started to depress germination ratio (77.32 %). 6. Finally, in connection with the duration of KOH treatment, a time lapse of up to 20 minutes depressed the germinating ratio(70.02 %) and 30 minutes to 45 minutes increased this ratio to 94.52 percent. 60 minutes of treatment depressed the germination to 75.62 percent.

  • PDF

Change in Chemical Compositions of Leachate and Medium Density Fiberboard from a Laboratory-scale Simulated Landfill

  • Lee, Min;Prewitt, Lynn;Mun, Sung Phil
    • Journal of the Korean Wood Science and Technology
    • /
    • v.44 no.2
    • /
    • pp.231-240
    • /
    • 2016
  • The change in chemical compositions of leachate and medium density fiberboard (MDF) from a laboratory-scale simulated landfill which constructed in a plastic container containing alternating layers of soil and MDF was investigated to evaluate decomposing of MDF in soil. Four treatments were conducted: 1) MDF in soil, 2) MDF only, 3) cured UF resin in soil, and 4) soil only. Molecular weight (MW) distribution of compounds in leachate from soil only treatment did not change over time. In UF resin in soil treatment, the MW distribution shifted to a lower MW distribution over time, while the peak shifted to the left indicated changing to higher MW distribution in leachate from treatment 1 and 2 contained MDF. Higher percent nitrogen in leachate was observed in MDF containing treatments due to the UF resin in the MDF. The percent carbon slightly increased in MDF only while that greatly decreased in MDF in soil treatment maybe due to bacterial activity. The percent of extractable materials from the MDF decreased greatly on day 35 compare to day 0, and subsequently did not change much on day 77. In contrast, percent holocellulose and lignin did not change much over time. No structural change of the wood fiber in MDF occurs during the study. Water-soluble materials from MDF in soil contributed the change in chemical composition of leachate.

Comparison of PET/MR image quality with and without point spread function algorithm according to reconstruction type (재구성 방법(점 확산함수 적용 유무)에 따른 PET/MR 영상 평가)

  • Park, Chan Rok;Moon, Il Sang;Noh, Gyeong Woon
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.22 no.1
    • /
    • pp.43-45
    • /
    • 2018
  • Purpose In this study, we evaluated image by applying with and without point spread function algorithm(PSF) according to reconstruction type. Materials and Methods Biograph mMR (Siemens, Germany) was used as PET/MR scanner. For phantom study, we used NEMA IEC Body phantom maintaining radioactivity ratio (hotsphere:background = 8:1). To evaluate phantom image quality, percent contrast recovery and signal to noise ratio (SNR) were used by drawing ROI to 4 spheres. In clinical study, the 20 patients who underwent simultaneous PET/MR was selected and set the ROI at liver. we evaluated images as SNR. Results In the phantom results, The percent contrast recovery applying PSF algoritm was high 5 % compared to without PSF algoritm and SNR was also high 11 %. In the clinical study result, we confirmed that The SNR applying PSF algoritm was high 5 % compared to without PSF algoritm. Conclusion We need to simulate a lot of phantom study and clinical analysis to improve image quality for PET/MRI.

Effect of Planting Dates and Nitrogen Fertilization Rates on the Forage Yield and Feeding Value of Introduced Triticale (파종기 및 질소 시비량이 도입 트리티케일의 수량 및 사료가치에 미치는 영향)

  • Yun, Seung-Gil;Kazuo Ataku
    • Journal of The Korean Society of Grassland and Forage Science
    • /
    • v.18 no.2
    • /
    • pp.113-122
    • /
    • 1998
  • This experiment was conducted to establish the cultural method of triticale(Triticum Secalotriticum Saratoviense Meister) as a whole crop silage by evaluating the effect of seeding date and nitrogen fertilization rate on forage yields and feeding value. Heading date, flowering date, and the dough stage of development came significantly earlier as triticale was seeded earlier. Soilage, dry matter yields and percent dry matter significantly varied with seeding dates and crude ash, NFE and TDN. However, TDN yield was significantly reduced by delayed seeding. Macromineral contents were not affected by seeding date. Soilage, dry matter yield, and percent dry matter significantly increased as nitrogen fertilization rate increased. The contents of crude protein, crude fat, crude ash, NFE, TDN and TDN yield also significantly increased. In contrast, crude fiber content of triticale decreased with increasing N fertilization rate.

  • PDF

Influence of Fruit Set Internode on Seed Germination and Seedling Vigor in Watermelon (수박의 착과절위가 종자 발아 및 유묘활력에 미치는 영향)

  • Park, Eun-Ji;Lee, Gyu-Bin;Park, Young-Gil;Suh, Jeong-Min;Kang, Jum-Soon
    • Journal of Environmental Science International
    • /
    • v.24 no.12
    • /
    • pp.1673-1679
    • /
    • 2015
  • This study was conducted to investigate the effects of fruit set internode on the germination of watermelon seeds. Generally fruits setted in higher than 20 internode were high percent of germination, fruit setted in low internode(5-10) is low. The higher fruit-set internode, fruit weight was significantly increased, but 1,000 seed weight was decreased the more fruit set internode. However number of seed was about 300 seeds irrespective of fruit-set internode. Investigating viability of seed by BP test, general percent germination was recorded highest at 5 flower cluster above 20 internode of fruit-set internode. In contrast, condition of fruit setted on 3, 4, 6 flower cluster were high percent of germination, regarded as unnormal germination not to be as normal seedling by 2~3%. Seed harvested at 5 flower-cluster had high viability on hypocotyl height and diameter of seedling through early growth test, but were not significant. Therefore 5 flower-cluster was optimum fruit-set internode to obtain high-quality seed.

Dietary Characteristics of the Elderly Living Alone from Low Income Status in Bucheon City

  • Park, Jin-Kyung;Son, Sook-Mee
    • Journal of Community Nutrition
    • /
    • v.5 no.3
    • /
    • pp.160-172
    • /
    • 2003
  • This study was performed to investigate the dietary characteristics and related factors of the elderly female living alone. The subjects were 70 single living elderly female residing in Bucheon city and receiving benefits from the government based social welfare programs. Seventy nine percent of the subjects had self reported monthly income less than 200,000 (won) and forty one percent of the subjects were paying more than 100,000 (won) for food expense. The number of side dishes for a meal was two or three (35.71 %) or one or two (31.40%); fifty seven percent of the subjects ate reheated left-over for lunch and 70.0% for dinner. The proportion of the single living elderly at high nutrition risk ($\geq$ 6 as evaluated with Nutrition Risk Index Score) was 77.1 %. Cereals and their products contributed most to the macronutrients like energy, protein and carbohydrates and vitamin B. In contrast vegetables and their products contributed most to the fiber, minerals (Ca and Fe) and vitamins (vitamin A, vitamin B and vitamin C). The mean total score of depression was 8.59${\pm}$2.69 (full score: 12) meaning that the extent of depression was serious.

Feasibility of utilizing oven-drying test to estimate the durability performance of concrete

  • Chen, How-Ji;Tang, Chao-Wei;Peng, Hsien-Sheng
    • Computers and Concrete
    • /
    • v.8 no.4
    • /
    • pp.389-399
    • /
    • 2011
  • The increasing concern for reinforced concrete structure durability has been justifying in many ways in the last few decades. However, there is no perfect durability test method till now. In this research an alternative method, which is based on the cumulative moisture loss percent of the concrete specimens after oven-drying, was proposed to estimate the durability performance of the concrete. Two temperatures were considered for the oven-drying tests: $100^{\circ}C$ and $200^{\circ}C$. Test results showed that oven-drying at $200^{\circ}C$ was obviously an unsuitable procedure to preserve the fragile microstructure of cement-based materials. By contrast, experimental results through oven-drying at $100^{\circ}C$ allowed estimating the moisture loss percent of cement-based materials in a more rational manner. Moreover, the magnitudes of the cumulative moisture loss percent obtained from oven-drying tests at $100^{\circ}C$ for 48 hours have good correlations with the data of other well-known methods, namely, electrical resistance test, water permeability test, and mercury intrusion porosimetry test. This investigation established that regarding the oven-drying test as one of the tests for evaluating the potential durability of concrete is considerably practicable.

Comparison of PET image quality using simultaneous PET/MR by attenuation correction with various MR pulse sequences

  • Park, Chan Rok;Lee, Youngjin
    • Nuclear Engineering and Technology
    • /
    • v.51 no.6
    • /
    • pp.1610-1615
    • /
    • 2019
  • Positron emission tomography (PET)/magnetic resonance (MR) scanning has the advantage of less additional exposure to radiation than does PET/computed tomography (CT). In particular, MR based attenuation correction (MR AC) can greatly affect the image quality of PET and is frequently obtained using various MR sequences. Thus, the purpose of the current study was to quantitatively compare the image quality between MR non-AC (MR NAC) and MR AC in PET images with three MR sequences. Percent image uniformity (PIU), percent contrast recovery (PCR), and percent background variability (PBV) were estimated to evaluate the quality of PET images with MR AC. Based on the results of PIU, 15.2% increase in the average quality was observed for PET images with MR AC than for PET images with MR NAC. In addition, 28.6% and 71.1% improvement in the average results of PCR and PBV respectively, was observed for PET images with MR AC compared with that with MR NAC. Moreover, no significant difference was observed among the average values using three MR sequences. In conclusion, the current study demonstrated that PET with MR AC improved the image quality and can be help diagnosis in all MR sequence cases.