• 제목/요약/키워드: Penumbra

검색결과 126건 처리시간 0.027초

허혈경계부의 감소를 보인 뇌졸중 환자에 대한 증례보고 (Study on the Ischemic penumbra concept in stroke patient by case study)

  • 고성규
    • 대한한방내과학회지
    • /
    • 제21권2호
    • /
    • pp.341-348
    • /
    • 2000
  • I have treated one ischemic stroke patient in acute stage with Seonghyangjeonggi-san, and observed remarkable reduction of the size ischemic portion in brain CT, notable improved motor power of patient. So I report this case of stroke patint. The ischemic penumbra, simply stated, is the part of the brain that is sandwiched brain regions committed to die and those that receive enough blood to communicate. Therefore, it is ischemic brain tissue that has just enough to communicte and function. The life expectancy of the penumbrais short. Although the penumbra is an elegant concept, in practice, it has been a difficult one to exploit. Up to now, a lot of research worker have tried to develop the method to make a accurate diagnosis. and then we know that PET and Xenon CT is available for the diagnosis for the ischemic penumbra. But those are not perfect to diagnose of penumbra. The case in my case report was confirmed as ischemic penumbra with CT. I know that CT is not prefect to diagnose penumbra, but I just want to raise the interest in penumbra of oriental medicine researcher and my report will be benificial to the penumbra researcher.

  • PDF

방사선치료시 물리학적 반음영의 검토 (Study on Physical Penumbra of Radiation Therapy)

  • 김영범;황웅구;김유현
    • 대한방사선치료학회지
    • /
    • 제6권1호
    • /
    • pp.84-88
    • /
    • 1994
  • Proper evaluation about the penumbra is very important to improve the efficacy of radiation theraphy. There are two kinds of physical penumbra, geometric penumbra and transmission penumbra. In this study, we evaluated the variation of physical penumbra according to the varing enery level, changing the field size and depth. Physical penumbra width was decreased as the source size decreased, and as the SDD increased, but the consideration about the scatter radiation and mechanical stability is an important factor. For the two adjacent beams, upper collimator should be used and especially for Co-60 unit, it is efficient to use the extended collimator.

  • PDF

방사선치료시 물리학적 반음영의 검토 (Study on Physical Penumbra of Radiation Therapy)

  • 김영범;황웅구;김유현
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제16권2호
    • /
    • pp.81-86
    • /
    • 1993
  • Proper evaluation about the penumbra is very important to improve the efficacy of radiation theraphy. There are two kinds of physical penumbra, geometric penumbra and transmission penumbra. In this study, we evaluated the variation of physical penumbra according to the varing energy level, changing the field size and depth. Physical penumbra width was decreased as the source size decreased, and as the SDD increased, but the consideration about the scatter radiation and mechanical stability is an important factor. For the two adjacent beams, upper collimator should be used and especially for Co-60 unit, it is efficient to use the extended collimator.

  • PDF

Penumbra Effect on Integral Absorbed Dose in Co-60 Teletherapy

  • Moon, Philip S.
    • Nuclear Engineering and Technology
    • /
    • 제5권2호
    • /
    • pp.87-93
    • /
    • 1973
  • Co-60원격치료장치에 장진된 Co-60 선원의 크기 때문에 Co-60원격치료시 치료부위에 반영부분이 생기게 되어 불필요한 방사선조사를 받게된다. 반영부분에서의 흡수적 산선량을 계산할 수 있는 식을 실험적으로 유도하였고, 실재로 Co-60원격치료에서 사용되는 조건을 실험식에 대입하여 반영의 크기가 흡수적산선랑에 미치는 영향을 연구해 보았다. 선원과 표피간의 거리가 크면 클수록 반영부분의 흡수적산선량은 커지고, 선원의 직경이 크면 클수록 반영부분의 흡수적산선량이 커진다. 선원과 피부간의 거리가 커지는데 따라, 어떤 경우에는 반영부분의 흡수적산선량이 치료부분의 흡수적산선량의 수배가 될 때도 있음을 알았다. 따라서 Co-60원격치료시에는 반영효과를 고려에 넣어 불필요한 방사선조사를 피하도록 하여야 하겠다.

  • PDF

6MV 방사선의 물리학적 Penumbra (The Physical Penumbra of the 6MV X-ray)

  • 조문준;강위생
    • Radiation Oncology Journal
    • /
    • 제9권2호
    • /
    • pp.333-336
    • /
    • 1991
  • 충남대학교병원 치료방사선과내 설치되어 있는 6MV선형가속기를 이용하여 음영을 측정하여 다음과 같은 결과를 얻었다. 1) 조사면 크기가 커질수록 음영폭은 중가하였으며 10x10 Cm 이상의 조사면에서는 계산한 음영폭보다 측정치가 대개 크게 나타났다. 조사면이 커질수록 이 차이는 더욱 증가하였다. 2) 깊이가 증가하면 음영폭도 증가하였다. 3) $90\%\~20\%$의 음영폭이 $80\%\~20\%$의 음영폭보다 컸으며 조사면이 커지고, 깊이가 증가할 수록 이 차이는 더 커졌다.

  • PDF

Chromospheric Canopy Fields over a Flux Emergence Region as a Key Condition for Formation of the Sunspot Penumbra

  • 임은경;;;조경석
    • 천문학회보
    • /
    • 제38권1호
    • /
    • pp.65.2-65.2
    • /
    • 2013
  • A presence of a penumbra is one of the main properties of a mature sunspot, and its formation mechanism has been elusive due to a lack of observations that fully cover the formation process. Utilizing the New Solar Telescope at the Big Bear Solar Observatory, we observed the formation of a partial penumbra for about 7 hours simultaneously at the photospheric (TiO; $7057{\AA}$) and the chromospheric ($H{\alpha}$, $-1{\AA}$) spectral lines with high spatial and temporal resolution. From this uninterrupted, long observational sequence, we found that flux emergence under the stable chromospheric canopy fields resulted in penumbra formation, while emerging flux under the expanding chromospheric fields appeared as transient elongated granules. Based on these findings, we suggest a possible scenario for penumbra formation in which a penumbra forms when the emerging flux is constrained from continuing to emerge, but rather is trapped at the photospheric level by the overlying chromospheric canopy fields.

  • PDF

다엽콜리매이터(Multileaf Collimator) 조사야의 반음영 및 선량분포 개선에 대한 연구 (A Study on the Improvement of Penumbra and Dose Distribution in the Multileaf Collimator Field Edge)

  • 김창욱;김회남;임충근;나수경;박병섭
    • 대한방사선치료학회지
    • /
    • 제10권1호
    • /
    • pp.88-93
    • /
    • 1998
  • Multileaf collimator is essential equipment in conformal radiation therapy, however the use is limitted by increase of penumbra width and undulating dose distribution at the field edge. The purpose of this study is to improve the penumbra and dose distribution in the multileaf collimator field edge. Measurement were performed with X-omat V film in solid water phantom using 6MV photon beam from Siemens linear accelerator. All the measurement were made along the central axis of $5{\times}5cm,\;10{\times}10cm$ circular field for constant SSD of 100 cm. To improve the penumbra and dose distribution collimator was rotated by 15 degrees from 0 to 90 degrees (collimator rotation method) and center was shifted to the longitudinal direction by fourth of lead width (center shift method). We compare the penumbra and dose distribution at the field edge to alloy block. Dose distribution and penumbra width at the feild edge of MLC showed undulated dose pattern and increased penumbra compared with alloy block. However, in the collimator rotation method and center shift method we abtained simular results with alloy block. Through the study we expected that clinical use of MLC will be increase.

  • PDF

광자선 치료시 Setup 오차에 따르는 Multi-leaf Collimator의 Scallop Penumbra 변화 효과 (The Dosimetric Effects on Scallop Penumbra from Multi-leaf Collimator by Daily Patient Setup Error in Radiation Therapy with Photon)

  • 이병용;조영갑;장혜숙
    • Radiation Oncology Journal
    • /
    • 제14권4호
    • /
    • pp.333-338
    • /
    • 1996
  • 목적 : 반복되는 환자 치료에서 환자의 Setup 오차가 Multi-leaf Collimator의 scallop penumbra에 미치는 효과와 이의 임상적 의미를 살펴보고자 하였다. 대상 및 방법 : MLC의 leaf 방향에 대해 $0^{circ},{\;}15^{circ},{\;}30^{circ},{\;}45^{circ},{\;}60^{circ},{\;}75^{circ}$ block 모양을 MLC와 통상적인 block으로 만들었다. 팬톰내에서 필름 측정법으로 통상적인 블록과 MLC가 만든 치료면의 penumbra 차이를 비교하였다. 방사선 치료는 30회 반복할 때의 setup 오차가 고려된 선량분포를 중첩방식으로 구하였다. 위치 변화값은 연구보고 수치를 근거하여 구하였다. 결과 : 평균 4mm setup error를 갖는 모델에서 1cm 폭분해능을 갖는 MLC가 만든 penumbra은 기존 차폐 블록에서 생긴 penumbra 보다 차폐 모양에 따라 $0\~3mm$ 증가하는 효과를 볼 수 있었다. 결론 : 치료 조사면을 결정할 때 MLC를 사용하더라도 ICRU 50에 따라 환자의 움직임을 고려하여 치료조사면을 결정하였다면, 기존의 방식과 동일하게 치료면을 정할 수 있으며, 필요에 따라 3mm의 여유를 두면 MLC 치료 조사면 내에 치료 부위가 충분히 포함된다.

  • PDF

p53 Protein Expression Area as a Molecular Penumbra of Focal Cerebral Infarction in Rats

  • Hong, Hyun-Jong;Park, Seung-Won;Kim, Young-Baeg;Min, Byung-Kook;Hwang, Sung-Nam;Suk, Jong-Sik
    • Journal of Korean Neurosurgical Society
    • /
    • 제38권4호
    • /
    • pp.293-298
    • /
    • 2005
  • Objective : The authors investigate the spatial characteristics of apoptotic genes expressed around the focal cerebral infarction, and attempted to explain the penumbra with them. Methods : A delayed focal cerebral infarction was created in twelve adult Sprague-Dawley rats. We performed the immunohistochemical staining for the apoptosis, bcl-2 and p53 proteins and measured the local cerebral blood flow [CBF] at the infarction core area and peri-infarct area pre- and intra-operatively. The peri-infarct area was divided into six sectors by distance from the infarction border. Results : The size [$mm^2$] of apoptosis, bcl-2, and p53 areas were $3.1{\pm}1.2$, $4.7{\pm}2.1$, and $6.8{\pm}2.4$, respectively. Apoptosis, bcl-2 or p53 positive cells were concentrated at the peri-infarct area adjacent to the infarction core. Their numbers reduced peripherally, which was inversely proportional to the local CBF. The p53 area seems to overlap with and larger than the ischemic penumbra. Conclusion : The p53 positive area provides a substitutive method defining the penumbra under the molecular base of knowledge.

다엽 콜리메이터(Multileaf Collimator)와 합금납 차폐물(Lead Alloy Block)의 반 그림자영역의 선량 분포상의 특성 비교 (Dosimetric Characteristics on Penumbra Regions of the Multileaf Collimator as Compared with the Lead Alloy Block)

  • 이상욱;오영택;김우철;금기창;윤성익;김현수;박원;추성실;김귀언
    • Radiation Oncology Journal
    • /
    • 제13권4호
    • /
    • pp.391-396
    • /
    • 1995
  • 목적 : 컴퓨터의 발달에 힘입어 3-D Conformal Radiotherapy(3-D CRT)가 가능하게 되었고 3-D CRT를 위해서는 다엽콜리메이터(MLC)가 필수적인 장치이다. 이에 본 저자들은 MLC 사용시 반그림자(Penumbra)의 크기와 그 특성을 알아보고 기존의 합금납(lead alloy block)을 사용할 때의 반그림자와 차이를 비교 분석하여 임상에서 다엽콜리메이터(MLC)의 이용에 도움이 되고자 본 연구를 계획하였다. 방법 : MLC와 합금납의 반그림자를 측정하기 위해 6MV 와 10MV 에너지의 방사선을 이용하여 필름선량분석을 시행하였다. 필름에 각에너지의 dmax와 10cm 두께의 폴리스탈린 판톰을 올려 놓고 측정하였고, MLC의 종단면과 조사면의 y축과 이루는 각도를 변화시키면서 Effective penumbra($20{\%}-80{\%}$)와 $10{\%}-90{\%}$ 반그림자를 측정하였다. 결과 : MLC의 각도가 0o에서 75o로 증가함에 따라 반그림자의 크기가 증가 하였고, 반그림자 영역에서 등선량곡선의 부채살모양이 심화 되었다. dmax에서 보다 10cm 깊이에서 반그림자의 크기가 약간 증가하였고, 에너지가 증가 하면서 약간 반그림자가 커지는 경향성만 보였다. 합금납을 사용할 경우의 반그림자보다 MLC를 사용할경우 최대 4.8mm가 더 크게 측정되었다. 결론 : 3-D CRT를 시행함에 있어서 반그림자 영역에서는 기존의 합금납 차폐물을 대신하여 MLC를 사용하여도 무방하리라는 결론을 얻을 수 있었다.

  • PDF