• Title/Summary/Keyword: Penetration Resistance

Search Result 763, Processing Time 0.029 seconds

Prediction of Compaction, Strength Characteristics for Reservoir Soil Using Portable Static Cone Penetration Test (휴대용 정적 콘 관입시험을 통한 저수지 제방 토양의 다짐, 강도 특성 및 사면 안정성 예측)

  • Jeon, Jihun;Son, Younghwan;Kim, Taejin;Jo, Sangbeom;Jung, Seungjoo;Heo, Jun;Bong, Taeho;Kim, Donggeun
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.65 no.5
    • /
    • pp.1-11
    • /
    • 2023
  • Due to climate change and aging of reservoirs, damage to embankment slopes is increasing. However, the safety diagnosis of the reservoir slope is mainly conducted by visual observation, and the time and economic cost are formidable to apply soil mechanical tests and slope stability analysis. Accordingly, this study presented a predicting method for the compaction and strength characteristics of the reservoir embankment soil using a portable static cone penetration test. The predicted items consisted of dry density, cohesion, and internal friction angle, which are the main factors of slope stability analysis. Portable static cone penetration tests were performed at 19 reservoir sites, and prediction equations were constructed from the correlation between penetration resistance data and test results of soil samples. The predicted dry density and strength parameters showed a correlation with test results between R2 0.40 and 0.93, and it was found to replace the test results well when used as input data for slope stability analysis (R2 0.8134 or more, RMSE 0.0320 or less). In addition, the prediction equations for the minimum safety factor of the slope were presented using the penetration resistance and gradient. As a result of comparing the predicted safety factor with the analysis results, R2 0.5125, RMSE 0.0382 in coarse-grained soil, R2 0.4182 and RMSE 0.0628 in fine-grained soil. The results of this study can be used as a way to improve the existing slope safety diagnosis method, and are expected to be used to predict the characteristics of various soils and inspect slopes.

The Evaluation of Resistance of Multi-degregation on Concrete Coated High Performance Penetration Agency (고성능 표면침투제가 도포된 콘크리트의 복합열화저항성 평가)

  • Yoo, Sung-Won;Suh, Jeong-In;Ha, Hyun-Jae;Lee, Sang-Min;Park, Sang-Sun
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2004.11a
    • /
    • pp.241-244
    • /
    • 2004
  • The evaluation of Single or multi-degregation of concrete coated by high performance surface penetration agency was examined through various tests, i.e., carbonation, absorption, carbonation + chloride ion and carbonation + chemical solution according to various high performance surface penetration agencies and various compressive strengths of base concrete. The 2 types of high performance surface penetration agencies were used i.e., inorganic and alcohol soluble. And 2 types of compressive strength of base concrete were used such as 21 30. MPa. The characteristics of concrete coated high performance surface penetration agency was more improved than that of non-coated concrete, and especially, water soluble inorganic agency was most effective. And if compressive strength of base concrete was low, the improved effects would be larger.

  • PDF

Improvement of the Exisiting Nuclear Concrete Structures Durability Using Surface Penetration Sealer (표면침투제를 이용한 원전구조물의 내구성 향상)

  • Lho, Byeong-Cheol;Choi, Kyu-Hyung;Lee, Sang-Min
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2004.11a
    • /
    • pp.257-260
    • /
    • 2004
  • The durability and water - resisting capability of nuclear concrete structures can be greatly improved as the density of concrete surface increases. Applying the surface penetration sealer to the concrete surface can increase the surface density. Therefore, the objective of this study is to identify the most suitable surface penetration sealer based on lab test. The considered parameters rate and water resistance and absorbance rate of the concrete specimen after the penetration sealer are applied. The experimental study resulted in the identification of the two most suitable surface penetration sealer based on their performance.

  • PDF

The virtual penetration laboratory: new developments for projectile penetration in concrete

  • Adley, Mark D.;Frank, Andreas O.;Danielson, Kent T.;Akers, Stephen A.;O'Daniel, James L.
    • Computers and Concrete
    • /
    • v.7 no.2
    • /
    • pp.87-102
    • /
    • 2010
  • This paper discusses new capabilities developed for the Virtual Penetration Laboratory (VPL) software package to address the challenges of determining Penetration Resistance (PR) equations for concrete materials. Specifically, the paper introduces a three-invariant concrete constitutive model recently developed by the authors. The Advanced Fundamental Concrete (AFC) model was developed to provide a fast-running predictive model to simulate the behavior of concrete and other high-strength geologic materials. The Continuous Evolutionary Algorithms (CEA) automatic fitting algorithms used to fit the new model are discussed, and then examples are presented to demonstrate the effectiveness of the new AFC model. Finally, the AFC model in conjunction with the VPL software package is used to develop a PR equation for a concrete material.

Normalization of Cone Resistance in Granular Soil (모래지반에서 콘 저항값의 정규화에 관한 연구)

  • Na Yung-Mook
    • Journal of the Korean Geotechnical Society
    • /
    • v.20 no.9
    • /
    • pp.33-45
    • /
    • 2004
  • Sandfill at reclaimed sites is usually formed by more than one placement method. Reclaimed sandfill often shows highly variable profiles and the cone penetration test is most commonly used for site characterization. Correlations between cone resistance and geotechnical parameters for sand are influenced by in-situ stress level and it is important to incorporate stress level effect. In this study, cone penetration tests were performed at several elevations from the top of a 10m high surcharge, which was later removed step by step. In order to establish more reliable correlations between cone resistance and geotechnical parameters for sand, different ways of normalizing cone resistance by the corresponding in-situ vertical stress were investigated.

A Study on the Resistance to Seawater Attack of Mortars and Concretes Incorporating Limestone Powder (석회석미분말을 혼입한 모르타르 및 콘크리트의 내해수성 연구)

  • Lee, Seung Tae;Jung, Ho Seop
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.15 no.1
    • /
    • pp.129-137
    • /
    • 2011
  • This study aims to evaluate the resistance to seawater attack of mortars and concretes incorporating limestone powder (0, 10, 20 and 30% of cement by mass). In order to achieve this goal, both chemical resistance by seawater and chloride ions penetration resistance of mortars or concretes were regularly monitored. From the test results, it was observed that the durability of cement matrix was greatly dependent on the replacement ratios of limestone powder. In other words, performance of cement matrix with 10% limestone powder was similar to that of OPC matrix. However, it was found that a high replacement ratio of limestone powder was ineffective to resist seawater attack.

Field Investigation of Chloride Penetration and Evaluation of Corrosion Characteristics for Deicer (염화물 침투 현장조사 및 제설제에 따른 부식특성)

  • Yang, Eun-Ik;Kim, Myung-Yu;Park, Hae-Geun
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.8 no.6
    • /
    • pp.47-52
    • /
    • 2008
  • Deicer has been generally used for prevention of a road freezing in winter, and the usage amount is increasing every year. However, deicer may induce the decrease of bond strength, surface scaling, and environmental pollution. In this study, the field test was performed to investigate the deterioration of concrete road structures used for 17 years. And, the corrosion resistance characteristics were compared for the existing deicer and eco-friendly deicer. According to the field test results, the penetration depth of limit chloride amount was about 40mm, and the average concentration of chloride was $3.45kg/m^3$ at the surface of structures. On the contrary, the carbonation depth was slight. The penetration depth of eco-friendly deicer was less than the existing deicer, and the corrosion resistance of eco-friendly deicer was higher.

A Study on the Engineering Properties of Alluvial clay in the Daebul Reclaimed Tideland (대불간척지 충적점토의 공학적 특성에 관한 연구)

  • 김홍일;진병익;유기송
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.26 no.1
    • /
    • pp.29-37
    • /
    • 1984
  • This study was made to find several significant relations among various physical and mechanical properties including cone penetration resistance. The alluvial clay samples were taken at the Daebul Reclaimed Tideland in Samhomyeon, Yeongamgun, Jeonranamdo. The results of the study are summarized as follows; 1.Most samples belong to medium or high plastic, inorganic, silty clay(clay contents;32-64%, silt contents; 36-68%, sand contents; 0-3%). The specific gravities range from 2.70 to 2.73, the unit weights from 1.45 to 1. 75g/cm$^3$, the natural moisture contents from 45 to 77%, the liquid limits from 32 to 56%. It is certain that the foundation is weak because the natural moisture contents are much higher than the liquid limits. 2.It is known from the shear tests that the unconfined compression strenghs vary from 0.09 to 0. 38kg/cm2, the cohesions from 0.05 to 0. 21kg/cm2, the internal friction angles from 0 to 3˚. 3.The consolidation tests show that the initial void ratios range from 1.25 to 2.28, the compression indeices from 0.43 to 0.84, the preconsolidation loads from 0.21 to 0.74kg/cm$^2$. 4.Cone penetration resistances are usually less than 5kg/cm$^2$ from ground surface to the depth of about 8m, and from S to l0kg/cm$^2$ in the layer below about 8m to hard layer. 5.The cohesion and cone penetration resistance are in proportion to the depth of soil layer. 6.The correlations between various physical and mechanical properties including cone penetration resistance for the alluvial clay samples are as follows; a) Wn=0.944C+ l2.733 (r=0.829) b) LL=0. 728Cy+6. 991 (r=0. 873) c) PI=0.659Cy-8.168 (r=0.860) d) rt=0. 0077(272-Wn) =2.092-0. 0077Wn (r=0. 859) e) 60=0. 035wn-0 447 (r=0. 893) f) C=0.380qw+0.031 (r=0.816) g) qu=0.0707qc+0.029 (r=0.810) h) C=0.018Z+0.055 (r=O.802) I) qc=0. 415Z+1, 438 (r=0. 943)

  • PDF

Estimation of Setting Time of Concrete Using Rubber Hardness Meter (고무경도계를 이용한 콘크리트의 응결시간 추정 가능성 분석)

  • Han, Min-Cheol;Han, In-Deok;Shin, Yong-Sub
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.7 no.4
    • /
    • pp.358-366
    • /
    • 2019
  • The purpose of this study is to explore the possibility of estimating optimum surface finishing work time of the fresh concrete placed at the job site by applying a surface hardness test meter(Durometer). Tests are carried out by measuring and comparing the Proctor penetration resistance test and hardness test by Durometer. Correlations between Procter penetration test and hardness test by Durometer were obtained. Two different types Durometer were applied to estimate setting time. Test results indicate that the measurement of the Durometer and the test of the Proctor penetration resistance are highly correlated. When measuring the initial setting time with Durometer, initial setting time is reached when the hardness value by the type C Durometer is reached around 42HD, and when final setting is measured with the type D Durometer, the surface finishing work time limit and curing time can be estimated with 10HD of Durometer.

Design for Installation of Suction Piles in Sand Deposits for Mooring of Floating Offshore Structures (부유식 해상구조물의 계류를 위한 사질토 지반의 석션파일 설계)

  • Park, Chul-Soo;Lee, Ju-Hyung;Baek, Du-Hyun;Do, Jin-Ung
    • Journal of the Korean Geotechnical Society
    • /
    • v.30 no.10
    • /
    • pp.33-44
    • /
    • 2014
  • The preliminary design of suction pile as the supporting system for concrete floating structures was performed for the pilot project of the southwest coast area in Korea. Prior to starting design work, site conditions of the area including ground and hydraulic conditions, and a 100-year return period external force were throughly evaluated. The suction pile for mooring of the offshore floating structures has to satisfy the lateral resistance against external force as well as the penetration ability according to the soil conditions such as soil types, shear strengths, effective stresses, and seepage forces. In the design, the required penetration depths, which were stable for lateral resistance, were evaluated with the diameters of cylindrical suction pile as the final installing ones. And the design suction pressures at each penetrating depths, at which sand boiling did not occur, were assessed through the comparison of penetration and penetrationresistance forces. As a result, it was impossible for suction piles with the diameter range of 3.0~5.0 m to penetrate into required penetration depths. On the other hand, suction piles with the diameter range of 6.0 m and 7.0 m satisfied both the horizontal stability and the penetration ability by design suction pressures at the required penetration depths of 8.5 m and 8.0 m, respectively.