• 제목/요약/키워드: Peltier

검색결과 128건 처리시간 0.03초

$(Bi, Sb)_2 (Te, Se)_3$ 열전박막소자의 작동특성 (Performance of $(Bi, Sb)_2 (Te, Se)_3$ Thin Film Thermoelectric Modules)

  • 김일호;이동의
    • 한국진공학회지
    • /
    • 제3권3호
    • /
    • pp.309-315
    • /
    • 1994
  • 순간증착법으로 p형(Bi0.5Sb1.5Te3)과 n형(Bi2Te24Se0.6)열전박막을 제조하여 상온에서 Seebeck 계 수, 전기전도도 및 열전성능지수를 측정하였다. 또한 금속재 mask를 이용하여 다중접점 박막형 열전소 자를 제작하고 그 작동특성을 조사하였다. 이때 소자의 고온부와 저온부의 온도를 직접측정하기 위하여 copper/constantan 박막을 접점부에 증착하여 열전쌍이 되게 하였다. p/n 접점이 5쌍이 소자의 경우 Peltier 효과에 의해 생성된 최대온도차는 22K이었다.

  • PDF

발바닥 부위 쿨링이 심부 체온에 미치는 효과 (The Effect of Foot Cooling on Body Temperature)

  • 박유진;김정훈;박지은;김지인;이종민
    • 대한의용생체공학회:의공학회지
    • /
    • 제38권5호
    • /
    • pp.232-236
    • /
    • 2017
  • In this study, We investigated the effect of foot cooling on the reduction of body temperature after hard exercise at the high temperature of $40^{\circ}C$. We performed a total of 30 subjects, and the subjects performed treadmill exercise for 30 minutes. We produced the cooling device to cool the foot using Peltier module. After the end of the exercise, We performed normal recovery method and cooling recovery method(one foot, both feet) for 1 hour on the same indoor environmental conditions and confirmed the change of body temperature of subjects. The results of deep body temperature measurement showed average $38.78{\pm}0.22^{\circ}C$ to $38.54{\pm}0.15^{\circ}C$ when the normal recovery method was performed. Cooling recovery method on one foot showed average $38.69{\pm}0.14^{\circ}C$ to average $38.06{\pm}0.17^{\circ}C$ and Cooling recovery method on both feet showed average $38.69{\pm}0.15^{\circ}C$ to average $37.84{\pm}0.21^{\circ}C$. There was a significant difference between the normal recovery method and the one foot cooling recovery method(p < .05), there was a significant difference between the normal recovery method and the both feet cooling recovery method(p < .05) and there was a significant difference between the one foot cooling recovery method and the both feet cooling recovery method(p < .05). Body temperature showed the lowest decrease rate when the normal recovery method was performed, and body temperature showed the highest decrease rate when the both feet cooling recovery method was performed. Therefore, recovery of cooling on the foot after hard exercise have decreased body temperature, delay fatigue in the body, and will be contributed to improvement of athlete performance.

강제대류에서 펠티에 소자를 이용한 내부터널 구조를 가지는 히트싱크에 관한 연구 (A Study on the Heat Sink with internal structure using Peltier Module in the Forced Convection)

  • 이민;김태완
    • 한국산학기술학회논문지
    • /
    • 제15권6호
    • /
    • pp.3410-3415
    • /
    • 2014
  • 전자 장비에서 발생하는 열은 장비의 성능을 저하시킨다. 이러한 장비의 열을 외부로 방출하기 위한 방법으로 히트싱크가 사용된다. 본 연구에서는 내부터널의 형상을 가지는 히트싱크에 대한 냉각 및 히팅성능을 강제대류 상태에서 열전달 특성에 대하여 고찰하였다. 또한, 시간에 따른 히트싱크의 열전달 특성 및 온도분포의 변화에 따른 실험을 수행하였다. 냉각실험에서 전압이 10V일 때, A형상이 B형상 보다 온도가 낮게 나타났고, 가장 좋은 냉각효과를 나타내었다. 히팅실험에서 전압이 13V일 때, 온도가 A형상이 B형상 보다 높게 나타났고, A형상이 효율이 더 좋은 것으로 판단된다.

헤드각이 변화하는 Electrosurgical Knee Wand에 적용된 형상기억합금 스프링의 전기적 피로특성 (Electro-fatigue Characteristic of Shape Memory Alloy Applied to the Electrosurgical Knee Wand of Variation of Wand Head Angle in Electrosurgical Knee Surgeries)

  • 안재욱;김철웅;이호상;왕준호;오동준
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2008년도 추계학술대회A
    • /
    • pp.1547-1552
    • /
    • 2008
  • The tip of these catheter with straight needles is not able to reach in the vicinity of the disc bulging, which are the cause of the low back pain and because the far indirect radio-frequency treatment results in the decompression, the nucleoplasty has the limit. Many incurable diseases has not been solved due to the unexistence of the advanced technique for the MIS human body catheter device. To increase the possibility of nucleoplasty, the needle tip should be located at the closest area of the lesion. For this reason, the best way to increase the success rate of the operation is that the needle tip should access 3-dimensionally to the operating field as soon as possible. To achieve this aim, our studies are restricted as follows: 1) the SMA catheter design to control the 3-dimensional direction, 2) the security of the immediate response by the positive control of the SMA element thermal distribution using Peltier thermoelectric elements, 3) the aquisition of the control data by monitoring the relationship between the temperature of SMA element and the displacement, and 4) the design of the controller to guarantee the accurate location.

  • PDF

휴대용 인큐베이터의 개발에 관한 연구 (Study on Development of Portable Incubator)

  • 에이자드 아믈;파락 자흐라;함자 알람;하산 따히르;아프라시압 칸 반가시;류성기
    • 한국기계가공학회지
    • /
    • 제18권9호
    • /
    • pp.1-6
    • /
    • 2019
  • Preterm children require a controlled environment that is as close as possible to that inside the womb. Incubators are well equipped to fulfill this requirement; however, they are cumbersome and expensive, thereby restricting their portability and availability in less developed and rural areas. This research comprises the development and system validation of a portable incubator. The system consists of a collapsible baby enclosure that can be stowed inside the system base when not in use. The enclosure is made from acrylic such that it is easy to clean and allows unhindered visual observation of the occupant while being robust enough to withstand transit conditions. The system can be powered either by a mains supply or a 12-VDC automobile power supply. Additionally, it has an onboard battery to ensure a continuous supply during transit. A Peltier plate controlled using a microcontroller ensures the desired enclosure temperature irrespective of the ambient temperature. Built-in sensor probes can measure the skin temperature, pulse rate, blood oxygenation level, and ECG of the infant and display them on the system screen. The system function is validated by testing its peak power consumption and the heating and cooling performances of the environment control system.

3D프린터를 이용한 겨울철 대류난방기구의 온도 성층화 해결을 위한 무동력 서큘레이터 디자인에 관한 연구 (The A Study on the Non-powered Circulator to Solve the Temperature Stratification of a Convection Heating Device during Winter Using 3D Printer)

  • 강희라
    • 디지털융복합연구
    • /
    • 제19권6호
    • /
    • pp.285-292
    • /
    • 2021
  • 최근 코로나19 사태로 캠핑 문화가 급속하게 많은 사람들에게 관심을 받고 있다. 많은 캠퍼들이 겨울철 사용하는 대류난방기구는 온도 성층화 문제를 가지고 있다. 이를 해결하기 위해 다양한 동력 서큘레이터가 활용되고 있다. 몇 가지 무동력 서큘레이터도 판매가 되고 있으나, 서큘레이터의 방향이 대류난방기구와 직각으로 디자인되어 있어 실제 공기 순환의 역할을 제대로 하지 못하고 있다. 이러한 문제점을 해결하고자 3D 프린터를 이용하여 대류난방기구의 방향과 같은 무동력 서큘레이터를 디자인하였다. 펠티어소자와, 세라믹페이퍼 등을 이용하여 무동력으로 전기를 만들어 냈으며, HTPLA-CF 필라멘트를 이용하여 열에 강하게 제작하였다. 3D 프린터를 이용하여 원가를 절감할 수 있었으며, 다양한 대류난방기구의 크기에 맞게 제작 할 수 있는 장점이 있다. 본 연구는 효율적인 대류순환을 통해 온도 성층화 문제를 해결할 수 있는 하나의 방법을 제시한다. 또한 3D 프린터를 이용하여 보다 저렴하게 제품을 제작하는 것이 본 연구의 목적이다.

광분광기의 노이즈 감소를 위한 암전류에 대한 실험적 고찰 (Experimental Study on Dark Current Noise to Reduce Background Voltage Level of Optical Emission Spectroscopy)

  • 육영준;이건우;최은종;김효영;김기현
    • 반도체디스플레이기술학회지
    • /
    • 제22권4호
    • /
    • pp.93-98
    • /
    • 2023
  • As semiconductor devices become highly integrated and process difficulty increases, the need for highly sensitive sensors that can detect micro leaks is increasing. However, the noise contained in the CCD sensor itself acts as an obstacle to detecting fine leaks. In this study, integration time was changed for each condition, the sensor was cooled to 0℃, and the dark voltage level was measured to confirm through experiment the characteristics of the temporal noise included in the CCD sensor, a component of OES (Optical Emission Spectroscopy). When integration time was reduced from 30msec to 10msec, the dark voltage level decreased by about 20.5 % from an average of 151.5mV to 120.5mV. In the case of cooling device, Peltier elements were selected because of their simple structure and small size. During temperature cooling, the target temperature was controlled to within ±0.5℃ through PID control. When cooled from 20℃ to 0℃ using this cooling device, it was confirmed that the dark voltage level decreased by about 7% from an average of 147.0mV to 137.0mV.

  • PDF

High-power Femtosecond Ti:sapphire Laser at 1 KHz with a Long-cavity Femtosecond Oscillator

  • Sung, Jae-Hee;Hong, Kyung-Han;Nam, Chang-Hee
    • Journal of the Optical Society of Korea
    • /
    • 제7권3호
    • /
    • pp.135-138
    • /
    • 2003
  • A chirped-pulse amplification femtosecond Ti:sapphire laser operating at 1 KHz has been developed. The laser system consisted of a long-cavity femtosecond oscillator, a four-pass grating pulse stretcher, two multi-pass amplifiers and a double-pass grating pulse compressor. Thermal lensing at the amplifiers was reduced by cooling Ti:sapphire crystals using Peltier coolers. Gain narrowing and residual phase errors were compensated for by the use of an acousto-optic pulse shaper. The final laser output had an energy per pulse of 2.0 mJ and a pulse duration of 19.5 fs, reaching 0.1 TW at 1 KHz.

열전소자를 이용한 히트펌푸에 관한 연구 (A study of thermoelectric Heat Pump device)

  • 박창엽
    • 대한전자공학회논문지
    • /
    • 제5권1호
    • /
    • pp.6-12
    • /
    • 1968
  • 이 연구는 열전장치에서 펠티어 효과를 이용한 전기저항 , , 열주전력 , , 열전달도 , 인 BiTe의 n형소자 및 P형소자로 구성된 열전장치를 만들어 열전냉각 및 열전가열시험을 하였다. 진공속에서 고온부에 대한 저온부의 온도를 측정한 결과 42 degree C의 차가 되었다.

  • PDF