• Title/Summary/Keyword: Peel-test

Search Result 236, Processing Time 0.027 seconds

A Study on Carbon Fiber Sheet Rehabilitation of High Strength Reinforced Concrete Beams Mixed Steel Fibrous (강섬유를 혼입한 고강도 콘크리트 보의 탄소섬유쉬트 보강에 관한 연구)

  • 곽계환;곽경헌;정태영;고성재
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2001.11a
    • /
    • pp.491-496
    • /
    • 2001
  • In recent years, the research and development about the new material proceed rapidly and actively in the building industry. As building structures become bigger, higher and more specialized, so does the demand for material with higher strength. In the future, we will need to research repair and rehabilitation to make high strength concrete mixed steel fibrous building safe. The carbon fiber reinforced plastic bonding method is widely used in reinforcing the existing concrete structure among the various methods. The repair of initiate loaded reinforced high-strength concrete beams mixed steel fibrous with epoxy bonded Carbon Fiber Sheets(CFS) was investigated experimentally. The CFS thickness and length were varied to assess the peel failure at the curtailment of CFS, The behaviour of the repaired beams was represented by load-longitudinal steel strain relation and failure modes were discussed. The test results indicate that CFS is very effective for strengthening the demand beams and controlling deflections of reinforced high strength concrete beams mixed steel fibrous happen diagonal crack, the increase in the number of CFS layers over two layers didn't effect the increase in the strength of beams.

  • PDF

Bilateral fibrothorax with constrictive pericarditis (위축성 심낭염 [Constrictive Pericarditis]을 동반한 양측성 섬유흉 [Fibrothorax] 치험 1)

  • Sun, Kyung;Kim, Yo-Han;Baek, Kwang-Je;Lee, Chol-Sae;Kim, Hark-Jei;Kim, Hyoung-Mook
    • Journal of Chest Surgery
    • /
    • v.17 no.4
    • /
    • pp.703-708
    • /
    • 1984
  • Fibrothorax is the end stage of chronic pathologic processes of pleura such as hemothorax, empyema, or tuberculous effusion. The pleural space become adherent and obliterated, and the lung parenchyma is covered by a thick, fibrous, unexpandable "peel", so the lung function is diminished markedly with impaired ventilation and oxygenation. Constrictive pericarditis is often accompanied fibrothorax, also cardiac and hemodynamic function is deteriorated. Surgical relief of these fibrous peels causes remarkable improvement in pulmonary function, cardiac and hemodynamic function, and subjective symptoms. We experienced a case of bilateral fibrothorax combined with constrictive pericarditis which occured 3 years after bilateral tuberculous effusion. Decortication and percardiectomy were done at the same time through bilateral submammary thoracotomy with sternal transection. Comparing postoperative Peripheral venous pressure, Circulation time, Pulmonary function test, Arterial blood gas analysis, Subjective symptoms with preoperative conditions showed noticeable improvement.provement.

  • PDF

Fiber optic smart monitoring of concrete beam retrofitted by composite patches

  • Kim, Ki-Soo;Chung, Chul;Lee, Ho-Joon;Kang, Young-Goo;Kim, Hong
    • Structural Engineering and Mechanics
    • /
    • v.17 no.3_4
    • /
    • pp.347-356
    • /
    • 2004
  • In order to extend the lifetime of buildings and civil infrastructure, patch type fibrous composite retrofitting materials are widely used. Retrofitted concrete columns and beams gain stiffness and strength, but lose toughness and show brittle failure. Usually, the cracks in concrete structures are visible to the naked eye and the status of the structure in the life cycle is estimated through visual inspections. After retrofitting of the structure, crack visibility is blocked by retrofitted composite materials. Therefore, structural monitoring after retrofitting is indispensable and self diagnosis method with optical fiber sensors is very useful. In this paper, we try to detect the peel out effect and find the strain difference between the main structure and retrofitting patch material when they separate from each other. In the experiment, two fiber optic Bragg grating sensors are applied to the main concrete structure and the patching material separately at the same position. The sensors show coincident behaviors at the initial loading, but different behaviors after a certain load. The test results show the possibility of optical fiber sensor monitoring of beam structures retrofitted by the composite patches.

Study of Metal(Au) Bump for Transverse Ultrasonic Bonding (금속(Au)범프의 횡초음파 접합 조건 연구)

  • Ji, Myeong-Gu;Song, Chun-Sam;Kim, Joo-Hyun;Kim, Jong-Hyeong
    • Journal of Welding and Joining
    • /
    • v.29 no.1
    • /
    • pp.52-58
    • /
    • 2011
  • In this paper, the direct bonding process between FPCB and HPCB was studied. By using an ultrasonic horn which is mounted on the ultrasonic bonding machine, it is alternatively possible to bond the gold pads attached on the FPCB and HPCB at room temperature without an adhesive like ACA or NCA. The process condition for obtaining more bonding strength than 0.6 Kgf, which is commercially required, was carried out as 40 kHz of frequency, 0.6 MPa of bonding pressure and 2 second of bonding time. The peel off test was performed for evaluating bonding strength which results in more than 0.8 Kgf.

A study on the antibiotic effect using the d-limonene oil extracted to wasted mandarin peels in Cheju (제주 감귤피에서 추출한 d-limonene 오일의 항균 효과에 대한 연구)

  • Oh, Eun-Ha;Im, Ho-Sub;Yoon, Cheol-Hun
    • Journal of the Korean Applied Science and Technology
    • /
    • v.26 no.3
    • /
    • pp.350-356
    • /
    • 2009
  • The objection of this research is to conform of practicable possibility and recycling of producing junk after citrus fruits is processed. In the middle of practicable possibility, with verification of antibiosis that tactiling sensibility in a microorganism. With extracting d-limonene oil that have 70${\sim}$90% a component of oil out of junk citrus peel, making certain the about 12000ppm(1.2%) concentration of it. By means of antibiosis property over the a pathogenic bacterium as well as a residence bacterium, considerating the limit of application against daily living supplies needs to antibiosis. Antibiosis effect of a stationing bacterium in the body permanently and by means of antibiosis verification of special bacteria Propionibacterium Acnes that causative skin trouble is selected, in based the antibiotic sencitivity test check up result of minimal inhibitory concentration(MIC).

Nondestructive evaluation of spot weld quality using by ultrasonic measurement (초음파계측에 의한 SPOT용접품질의 비파괴평가)

  • 박익근
    • Journal of Welding and Joining
    • /
    • v.12 no.3
    • /
    • pp.109-117
    • /
    • 1994
  • Spot welding has wide used with a high work efficiency in the automotive and aerospace industries. Up to the present, the technique mainly used to test spot welds on production lines has been entirely depended upon destructive chisel or peel testing. Therefore, it's being very important assignment to secure the NDE technique which can be evaluate spot weld quality with more efficiency and high reliability. This paper discusses the feasibility of UNDE techniques to evaluate spot weld quality. For the sake of the approach to the quantitative measurement of nugget diameter and the discrimination of a the corona bond from nugget, ultrasonic c-scan image and distribution of reflective echo amplitude was measured by immersion method with the mechanical and the electronic scanning of point-focussed ultrasonic beam(25 MHz). As the results of this study, corona bond which is the most dangerous types of interface defects can be successfully detected, as well as expulsion and voids. Ultrasonic testing results were confirmed and compared by optical microscope and SAM(Scanning Acoustic Microscope) observation of the spot-weld cross section. The results show that the nugget diameter can be successfully measured with the accuracy of 0.8 mm.

  • PDF

Development of An Onion Peeler ( II ) - Air injection type peeling equipment - (양파 박피기 개발 (II) - 공기분사식 박피장치 -)

  • 민영봉;김성태;강동현;최선웅;유준현
    • Journal of Biosystems Engineering
    • /
    • v.27 no.4
    • /
    • pp.311-316
    • /
    • 2002
  • This study was carried out to investigate the optimum operating conditions of the air injection type onion peeling device which could be attached to a prototype onion peeler. An onion, stem and root was cut and some vertical line was dug in 1 mm depth on the skin, was put on the two parallel rollers. The diameters of the rollers were 105 mm and the ratio of peripheral velocity was 3:2, and moved by a geared motor. Air from the nozzle with high pressure and velocity was jetted to the rotating onion on the revolving rollers, and then the skin of the onion was stripped. On the test, the rolling characteristics of the experimental materials were measured. The effective peeling conditions were, the number of digging line on the skin of the onion was 4, and the air jet pressure was above 392.3 kPa(4.0 kg/$\textrm{cm}^2$) when the peripheral velocity was at 2.4 m/s. On these conditions, time requirement to peel an onion was less than 2 sec.

A Study on the Soldering Characteristic of 4 Bus Bar Crystalline Silicon Solar Cell on Infrared Lamp and Hot Plate Temperature Control (적외선 램프 및 핫 플레이트 온도 제어를 통한 4 Bus Bar 결정질 실리콘 태양전지 솔더링 특성에 관한 연구)

  • Lee, Jung Jin;Son, Hyoung Jin;Kim, Seong Hyun
    • Current Photovoltaic Research
    • /
    • v.5 no.3
    • /
    • pp.83-88
    • /
    • 2017
  • The growth of intermetallic compounds is an important factor in the reliability of solar cells. Especially, the temperature change in the soldering process greatly affects the thickness of the intermetallic compound layer. In this study, we investigated the intermetallic compound growth by Sn-diffusion in solder joints of solar cells. The thickness of the intermetallic compound layer was analyzed by IR lamp power and hot plate temperature control, and the correlation between the intermetallic compound layer and the adhesive strength was confirmed by a $90^{\circ}$ peel test. In order to investigate the growth of the intermetallic compound layer during isothermal aging, the growth of the intermetallic compound layer was analyzed at $85^{\circ}C$ and 85% for 500 h. In addition, the activation energy of Sn was calculated. The diffusion coefficient of the intermetallic compound layer was simulated and compared with experimental results to predict the long-term reliability.

Surface Modification Effect and Mechanical Property of para-Aramid Fiber by Low-temperature Plasma Treatment (저온 플라즈마 처리를 이용한 파라 아라미드 섬유의 표면 개질 효과 및 역학적 특성)

  • Park, Sung-Min;Kwon, Il-Jun;Kim, Myung-Soon;Kim, Sam-Soo;Choi, Jae-Young;Yeum, Jeong-Hyun
    • Textile Coloration and Finishing
    • /
    • v.24 no.2
    • /
    • pp.131-137
    • /
    • 2012
  • para-Aramid fibers were treated by low-temperature plasma to improve the adhesion. The surface of para-aramid fibers were treated with gaseous plasma of several discharge power and treatment time in oxygen gas at 1Torr pressure. The treated fibers at low-temperature plasma were taken oxygen-containing functional groups and micro-crator on the surface. The modified fibers were measured by dynamic contact angle analyzer and XPS(X-ray photoelectron spectroscopy). The Interfacial adhesion properties of aramid fabric and polyurethane resin were determined by T-peel test. The surface of aramid fibers were observed by FE-SEM photographs. It was found that surface modification and chemical component ratio of the aramid fibers were improved wettability and adhesion characterization.

Enhanced $Al_2O_3/Ti$ Interfacial Properties Using $NbC_xC_{1-x}/Y_2O_3$ Interlayers - (1) Sputtering and Thermal Stability ($NbC_xC_{1-x}/Y_2O_3$ 박막코팅을 이용한 $Al_2O_3/Ti$ 계면특성향상 - (1) 스퍼터링 및 열안정성)

  • 문철희
    • Journal of the Korean Ceramic Society
    • /
    • v.34 no.8
    • /
    • pp.908-913
    • /
    • 1997
  • Multilayer NbCxC1-x/Y2O3/Ti were sputter-coated on the alumina substrate, starting with a 0.7 ㎛ thick NbCxC1-x layer grown on substrate, followed by 0.7 ㎛ thick Y2O3 layer and 1 ㎛ thick Ti layer. To find out the optimum conditions for thickness uniformity and adhesion, sputtering works have been done with the variation of sputtering power and Ar pressure. After vacuum annealing at 950℃ and 1000℃, the thermal stability of the NbCxC1-x/Y2O3/Ti coated alumina substrates has been investigated by peel off test. The coating scheme didn't cause any debonded layer after an annealing at 950℃ for 3hrs. However, it was peeled off after annealing at 1000℃ for 3hr. It was found that the thermal stability of Al2O3/NbCxC1-x/Y2O3/Ti coating scheme changed with the NbCxC1-x composition.

  • PDF