• Title/Summary/Keyword: Pedometer

Search Result 32, Processing Time 0.03 seconds

Accuracy of Electronic Pedometers to Assess Body Fatness in Obese Children and Youth (비만 어린이와 청소년들의 체지방 평가를 위한 electronic pedometer 의 정확성 분석)

  • Kim, Do-Yeon
    • Journal of Life Science
    • /
    • v.19 no.10
    • /
    • pp.1368-1373
    • /
    • 2009
  • The purpose of this study was to assess the influence of waist size on the reliability and validity of pedometers to count steps in children and youth. The participants for this study were 20 children and youth, composed of 14 Hispanic and 6 Caucasian children. Ten children and youth had waist circumferences greater than the $85^{th}$ percentile (Body Mass Index (BMI)=$28.91\pm3.07$), and 10 children and youth had waist circumferences smaller than the $50^{th}$ percentile (BMI=$18.05\pm1.55$). To examine pedometer reliability, each child completed 3 ascent and descent trials up a set of 15 stairs while wearing a Yamax SW-701 pedometer. The main effect of trials was not statistically significant for the stair ascent trials F (2, 36)=2.575 or for the descent trials F (2, 36)=0.235. The trial by group interaction was also not statistically significant. To examine the influence of waist circumference on the validity of the pedometer in counting walking steps at a self-selected walking pace, the children and youth in the two groups completed a 400-m course. The main effect on the groups was statistically significant, F (1, 18)=7.489. The main effect of counting techniques was not statistically significant, F (1, 18)=2.983 (hand-counted vs. pedometer counted). Overall, the trial and trial by group interaction comparisons for the 400-m walk were not statistically significant, suggesting that the pedometer was equally valid as a tool for assessing walking steps in high waist circumference (HWC) and low waist circumference (LWC) in children and youth.

Design of a Robust Pedometer for Personal Navigation System against Ground Variation and Walking Behavior (지면 변화 및 보행 형태에 강인한 개인 항법 시스템용 걸음수 검출기 설계)

  • Jang, Han-Jin;Kim, Jeong-Won;Hwang, Dong-Hwan
    • The Transactions of the Korean Institute of Electrical Engineers D
    • /
    • v.55 no.9
    • /
    • pp.420-422
    • /
    • 2006
  • This paper proposes a new method to count the number of steps for personal navigation systems. The proposed method resolves the mis-counting problem caused by the variation of the ground and walking behavior. To this end, a 2-axis accelerometer is utilized and a reliable step counting algorithm is developed. Experimental test was carried out to show the effectiveness of the proposed method. Test results show that the proposed method gives a robust performance for several types of ground and walking behavior.

Assessment of Pedometer Counts, Physical Activity Level, Energy Expenditure, and Energy Balance of Weekdays and Weekend in Male High School Students (남자 고등학생의 주중과 주말의 보행수, 신체활동수준, 에너지 소비량 및 에너지 평형 평가)

  • Shin, Hyun-Mi;Jeon, Ji-Hye;Kim, Eun-Kyung
    • Journal of the Korean Dietetic Association
    • /
    • v.22 no.2
    • /
    • pp.131-142
    • /
    • 2016
  • The purpose of this study was to assess the physical activity and energy balance of weekdays and weekend in male high school students. Fifty healthy male high school students participated in this study. Anthropometric data were collected. Physical activity level (PAL) and energy intake for weekdays and weekend were calculated from a physical activity diary and food diary using the 24-hour recall method and interview. The resting metabolic rate (RMR) and estimated energy requirement (EER) were calculated from the prediction equations suggested in 2015 KDRIs. Total energy expenditure (TEE) was calculated by multiplying RMR by PAL. Mean age of subjects was $15.9{\pm}0.33years$. The daily pedometer counts were significantly higher in the weekdays (12,837 steps) than in weekend (6,661 steps) (P<0.001). The PAL of the weekdays ($1.63{\pm}0.17$) was significantly higher than that ($1.37{\pm}0.26$) of the weekend (P<0.001). PAL was significantly correlated with pedometer counts on the weekdays (r=0.495) and weekend (r=0.686). The total energy intakes ($2,847.2{\pm}681.5kcal$) and TEE ($3,046.3{\pm}437.3kcal$) of weekdays were significantly higher than those of the weekend. The results of this study would be useful to develop nutrition and exercise programs for male high school students on weekdays and weekend, respectively.

Personal Navigation System Using GPS and Dead Reckoning (GPS와 추축항법을 이용항 개인휴대 항법시스템)

  • Hong, Jin-Seok;Yoon, Seon-Il;Jee, Gyu-In
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.7 no.5
    • /
    • pp.454-464
    • /
    • 2001
  • In this paper, a personal navigation system is developed using GPS and dead reckoning sensors. This personal navigation system can be used to track a person inside a building, on an urban street, and in the mountain area. GPS can provide accurate absolute position information, but it cant be used without receiving enough satellite signals. Although the inertial sensors such as gyro an accelerometer and be used without this diggiculty, the inertial sensors severely suffer from their drift errors and the magne-tometer can be easily distorted by surrounding electromagnetic field. GPS and DR sensors can be inte-grated together to overcome these problems. A new personal navigation system that can be carried wit person is developed. A pedometer. actually vertically mounted accelerometer, detects ones footstep and gyro detects heading angle. These DR sensors are integrated with GPS and the humans walking pattern provides additional navigation information for compensating the DR sensors. The field testes are performed to evaluated the proposed navigation algorithm.

  • PDF

Design of Bowing-Activity Monitoring and Automatic Detection System Using 3-Axis Accelerometer (3축-가속도 센서를 이용한 배례(拜禮)동작 모니터링 및 자동검출 시스템 설계)

  • Lee, Young-Jae;Lee, Pil-Jae;Cha, Ji-Young;Sunoo, Sub;Hwang, Jin-Sang;Lee, Jeong-Whan
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.59 no.6
    • /
    • pp.1150-1158
    • /
    • 2010
  • In this paper, a new reliable portable activity monitoring device implemented with the buddhist-style bowing activity and walking step detection algorithm, is presented. In order to monitor the bowing and walking activities, miniaturized 3-axis accelerometer sensor with the sensitivity of 800 mV/g was used. After initial signal conditioning, vector magnitude of accelerometer signals was calculated. Syntactic peak detection method was used in order to feature points. All signal processing algorithms were implemented in ultra-low power microcontroller MSP430 with double precision floating point arithmetic. For evaluation, 19 young man($24.22\pm5.22$ yrs) and woman($22.28\pm2.72$ yrs) were involved. The accuracy of the proposed algorithms were 98.91 %($\pm0.011$) for walking step detection and 98.25 %($\pm0.023$) for buddhist-style bowing activity. Comparing to the commercialized pedometer accuracy, 87.1 %($\pm0.058$), the proposed walking step detection algorithms show more reliable accuracy.

Effect of a Randomized Controlled Trial Walking Program on Walking, Stress, Depressive Symptoms and Cardiovascular Biomarkers in Elderly Korean Immigrants

  • Sin, Mo-Kyung;Ibarra, Brandon;Tae, Thomas;Murphy, Patrick J.M.
    • Journal of Korean Biological Nursing Science
    • /
    • v.17 no.2
    • /
    • pp.89-96
    • /
    • 2015
  • Purpose: Despite well-known benefits of walking on cardiovascular health, no structured walking exercise program has been formally tested on elderly Korean immigrants (EKIs). This pilot randomized controlled trial study assessed the effect of a walking program on walking behavior (pedometer steps count), stress (cortisol), depressive symptoms (CESD-10), and cardiovascular disease biomarkers (hs-CRP and fibrinogen) via venipuncture in EKIs. Methods: Seventy EKIs recruited from a Korean community were randomly assigned to a 12-week walking group or control group in a 3:2 ratio. The working program included a pedometer, buddy, monthly coffee card, weekly call for goal setting, and physical activity consultation. Walking group EKIs maintained the Centers for Disease Control and Prevention recommended exercise guidelines and good mental health status over 12 weeks. Results: There was no significant difference in the outcomes between control and walking groups. Conclusion: Social networking with Koreans in the senior center and church from a well-established Korean community might have positive effects on mental health.

Assessment of Daily steps, Activity coefficient, Body composition, Resting Energy Expenditure and Daily Energy Expenditure in Female University Students (여대생의 1일 보행수, 활동계수, 신체조성, 휴식대사량 및 에너지 소비량의 평가)

  • Choe, Hyeon-Jeong;Song, Ju-Mi;Kim, Eun-Gyeong
    • Journal of the Korean Dietetic Association
    • /
    • v.11 no.2
    • /
    • pp.159-169
    • /
    • 2005
  • The purpose of this study was to assess the energy expenditure and investigate the relationship between related variables in 70 female university students. Resting energy expenditure estimated by Harris-Benedict formula, WHO/NAO/FAO formula and various formulas based on body weight and body surface area were 1366.9$\pm$74.4kcal/day, 1287.8$\pm$106.6kcal/day, 1171.4$\pm$155.8kcal/day and 1342.0$\pm$97.4kcal/day. Measured resting energy expenditure by indirect calorimetry(Model : Metavine and TrueOne2400) were 1582.0$\pm$150.1kcal/day and 1268.2$\pm$152.9kcal/day, respectively. Average step number per day was 11981.2$\pm$3014.4 steps and average step number per hour was 746.1$\pm$198.0 steps/hr. Daily energy expenditure by using Harris-Benedict formula, body weight formula, body surface area formula, WHO/NAO.FAO formula and 15-min check list formula were 2374.7$\pm$249.6kcal, 2033.5$\pm$313.2kcal, 2331.2$\pm$266.0kcal, 2240.8$\pm$185.5kcal and 2195.5$\pm$398.3kcal. Meanwhile energy intake of subjects was 1714.9$\pm$551.2 kcal. Daily energy expenditure has positive correlation(r=0.262) with daily step number. And there was significant positive correlations(r=0.35-0.68) between various daily energy expenditures and muscle mass. These results suggested that increase of daily step number by using pedometer is good method to increase daily energy expenditure. In particular, increase in step number can reinforce the amounts of muscle.

  • PDF

Performance Modeling and Evaluation of IEEE 802.15.4 Collision Free Period for Batch Traffic (배치 트래픽 특성을 고려한 IEEE 802.15.4 비경합구간 성능 모델링 및 평가)

  • Kim, Tae-Suk;Choi, Duke Hyun
    • The Journal of the Korea Contents Association
    • /
    • v.16 no.11
    • /
    • pp.83-90
    • /
    • 2016
  • In this paper, we performed the analysis of transmission performance for Collision Free Period(CFP) supported by the low-power communication technology, IEEE 802.15.4 MAC (Media Access Control). For the analysis, periodic traffic, original service target of CFP, is considered and, according to the Quality of Service required, packet arrival pattern to MAC layer is categorized as batch and non-batch, and analysis on throughput, delay, and energy is performed for those patterns. On the basis of the obtained analysis, performance comparison with Collision Avoidance Period(CAP) is carried out for the health care applications that generate periodic traffic such as Pedometer, ECG, EMG. The evaluation confirms that CFP is more energy efficient for healthcare applications that generate periodic and time-critical traffic and moreover for the application with high bandwidth requirement CFP achieves up to 46% energy savings compared to CAP.

A Study on a Measurement Method for pedometer using a Triaxial Sensor (3축 가속도 센서를 이용한 정확한 걸음 수 측정 방법 연구)

  • Lee, Seokwon;Kim, Donghwa;Park, Soyoung;Shin, Jieun;Shin, Hyowon;Seo, Dongmahn
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2016.10a
    • /
    • pp.503-505
    • /
    • 2016
  • 최근 전 세계적으로 비만의 문제점이 드러남에 따라 국가적 차원에서 비만인구를 줄이기 위한 노력을 하고 있다. 비만 해소에 가장 효율적인 운동으로 평가받고 있는 걷기운동을 효율적이고 효과적으로 수행할 수 있도록 도와주는 만보기는 다양한 형태의 기기 또는 어플리케이션으로 큰 인기를 얻고 있다. 이에 본 논문에서는 보다 정확한 만보기를 제작하기 위해 센서 및 체형, 신발의 종류에 따라 어떠한 특성을 가지는지 분석하고 효과적인 만보기 어플리케이션 구축 방법을 제안한다.

Design and Implementation of Walking Status Analysis System based on Multi-Sensors

  • Seo, Kwi-Bin;Lee, Seung-Hyun;Hong, Min
    • Journal of the Korea Society of Computer and Information
    • /
    • v.24 no.1
    • /
    • pp.159-166
    • /
    • 2019
  • Recently, the advanced development of smart devices has increased the interest in health-care, and many people are paying more attentions to disease prevention than disease treatment. Among these prevention methods, the bare body movement has received much attention, and especially walking exercise is attracting much attention because it is enjoyable without any restrictions on place and time. Walking exercise is generally divided into two types: walking on the ground and climbing the stairs. Walking up the stairs consumes much more calories compared to walking on the ground. These walking exercises have the advantage that they can be easily performed by male and female without special equipments or economic considerations. However, there is a lack of applications and systems that accurately determine such walking and stair walking and measure momentum according to stair walking. In this paper, we designed and implemented a real-time walking status analysis system using smartwatch's, pedometer, smartphone's barometer and beacons.