• Title/Summary/Keyword: Pedicle screw fixation

Search Result 83, Processing Time 0.024 seconds

Direct Pars Repair Surgery Using Two Different Surgical Methods : Pedicle Screw with Universal Hook System and Direct Pars Screw Fixation in Symptomatic Lumbar Spondylosis Patients

  • Shin, Myung-Hoon;Ryu, Kyeong-Sik;Rathi, Nitesh Kumar;Park, Chun-Kun
    • Journal of Korean Neurosurgical Society
    • /
    • 제51권1호
    • /
    • pp.14-19
    • /
    • 2012
  • Objective : The authors performed a retrospective study to assess the clinical and radiological outcome in symptomatic lumbar spondylolysis patients who underwent a direct pars repair surgery using two different surgical methods; pedicle screw with universal hook system (PSUH) and direct pars screw fixation (DPSF), and compared the results between two different treated groups. Methods : Forty-seven consecutive patients (PSUH; 23, DPSF; 15) with symptomatic lumbar spondylolysis who underwent a direct pars repair surgery were included. The average follow-up period was 37 months in the PSUH group, and 28 months in the DPSF group. The clinical outcome was measured using visual analogue pain scale (VAS) and Oswestry disability index (ODI). The length of operation time, the amount of blood loss, the duration of hospital stay, surgical complications, and fusion status were also assessed. Results : When compared to the DPSF group, the average preoperative VAS and ODI score of the PSUH group were less decreased at the last follow-up; (the PSUH group; back VAS : 4.9 vs. 3.0, leg VAS : 6.8 vs. 2.2, ODI : 50.6% vs. 24.6%, the DPSF group; back VAS : 5.7 vs. 1.1, leg VAS : 6.1 vs. 1.2, ODI : 57.4% vs. 18.2%). The average operation time was 174.9 minutes in the PSUH group, and 141.7 minutes in the DPSF group. The average blood loss during operation was 468.8 cc in the PSUH group, and 298.8 cc in the DPSF group. The average hospital stay after operation was 8.9 days in the PSUH group, and 7 days in the DPSF group. In the PSUH group, there was one case of a screw misplacement requiring revision surgery. In the DPSF group, one patient suffered from transient leg pain. The successful bone fusion rate was 78.3% in the PSUH group, and 93.3% in the DPSF group. Conclusion : The present study suggests that the technique using direct pars screw would be more effective than the method using pedicle screw with lamina hook system, in terms of decreased operation time, amount of blood loss, hospital stay, and increased fusion success rate, as well as better clinical outcome.

Polymethylmethacrylate-Augmented Screw Fixation for Stabilization of the Osteoporotic Spine : A Three-Year Follow-Up of 37 Patients

  • Moon, Bong-Ju;Cho, Bo-Young;Choi, Eun-Young;Zhang, Ho-Yeol
    • Journal of Korean Neurosurgical Society
    • /
    • 제46권4호
    • /
    • pp.305-311
    • /
    • 2009
  • Objective : The purpose of this study was to determine the efficacy, radiological findings, clinical outcomes and complications in patients with lumbar stenosis and osteoporosis after the use of polymethylmethacrylate (PMMA) augmentation of a cannulated pedicle screw. Methods : Thirty-seven patients with degenerative spinal stenosis and osteoporosis (T-score < -2.5) underwent lumbar fusion using the Dream Technology Pedicle Screw ($DTPS^{TM}$, Dream Spine Total Solutions, Dream STS, Seoul. Korea) between 2005 and 2007. The clinical outcomes were evaluated by using the visual analog scale (VAS) and the Prolo scale. Radiologic findings were documented through computed tomography (CT) and plain films. Results : Thirty-seven patients were evaluated and included, 2 males and 35 females with an average bone mineral density (BMD) of $0.47g/cm^2$. The average age of the patients was 68.7 (range, 57-88). The preoperative VAS for low back and leg pain ($7.87{\pm}0.95$ and $8.82{\pm}0.83$) were higher as compared with postoperative VAS ($2.30{\pm}1.61$ and $1.42{\pm}0.73$) with statistical significance (p = 0.006, p = 0.003). According to the Prolo scale, 11, 22, one and three patients were in excellent, good, fair and poor conditions, respectively. The average amount of the injected cement per one cannulated screw was $1.83{\pm}0.11\;mL$. Conclusion : The results show favorable outcome both clinically and radiographically for 37 patients who underwent lumbar fusion using $DTPS^{TM}$ and PMMA. Based on the results, the use of this surgical method can be a safe and effective option for the operation on the osteoporotic spine.

The Effects of Spinopelvic Parameters and Paraspinal Muscle Degeneration on S1 Screw Loosening

  • Kim, Jin-Bum;Park, Seung-Won;Lee, Young-Seok;Nam, Taek-Kyun;Park, Yong-Sook;Kim, Young-Baeg
    • Journal of Korean Neurosurgical Society
    • /
    • 제58권4호
    • /
    • pp.357-362
    • /
    • 2015
  • Objective : To investigate risk factors for S1 screw loosening after lumbosacral fusion, including spinopelvic parameters and paraspinal muscles. Methods : We studied with 156 patients with degenerative lumbar disease who underwent lumbosacral interbody fusion and pedicle screw fixation including the level of L5-S1 between 2005 and 2012. The patients were divided into loosening and non-loosening groups. Screw loosening was defined as a halo sign larger than 1 mm around a screw. We checked cross sectional area of paraspinal muscles, mean signal intensity of the muscles on T2 weight MRI as a degree of fatty degeneration, spinopelvic parameters, bone mineral density, number of fusion level, and the characteristic of S1 screw. Results : Twenty seven patients showed S1 screw loosening, which is 24.4% of total. The mean duration for S1 screw loosening was $7.3{\pm}4.1$ months after surgery. Statistically significant risk factors were increased age, poor BMD, 3 or more fusion levels (p<0.05). Among spinopelvic parameters, a high pelvic incidence (p<0.01), a greater difference between pelvic incidence and lumbar lordotic angle preoperatively (p<0.01) and postoperatively (p<0.05). Smaller cross-sectional area and high T2 signal intensity in both multifidus and erector spinae muscles were also significant muscular risk factors (p<0.05). Small converging angle (p<0.001) and short intraosseous length (p<0.05) of S1 screw were significant screw related risk factors (p<0.05). Conclusion : In addition to well known risk factors, spinopelvic parameters and the degeneration of paraspinal muscles also showed significant effects on the S1 screw loosening.

Comparison of Three Different Techniques in Cervical Transpedicular Screw Insertion

  • Seo, Young-Jun;Song, Geun-Sung;Cho, Won-Ho;Choi, Byung-Kwan;Cha, Seung-Heon;Baek, Sun-Yong
    • Journal of Korean Neurosurgical Society
    • /
    • 제39권5호
    • /
    • pp.360-365
    • /
    • 2006
  • Objective : This is a cadaver study to assess the accuracy of three cervical screw insertion techniques; the blind technique [Group I], the laminotomy technique [Group II], and the funnel technique [Group III]. Methods : Ten human cadavers embalmed with formaldehyde were prepared. After exposing the spinous processes, the laminas and the lateral masses, titanium alloy transpedicular screws were inserted from C3 to C7. A total of 100 pedicles were ramdomly assigned to one of three techniques [the blind technique : 31 screws, the laminotomy technique : 51 screws, the funnel technique: 18 screws]. Axial computed tomography with 1-mm slices, and sagittal and coronal reformation were performed to identify the accuracy of the screw insertion and the anatomic relationships. Results : In Group I, 9 screws [29%] were either contained within or penetrated less than 1mm, which were rated as successful. In Group II, 24 screws [47%] were successful. In Group III, 16 screws [89%] were successful. In the multiple comparison, there was a statistically significant difference between Groups I and III and between Groups II and III [$X^2$ test and Bonfenoni test]. Conclusion : The funnel technique can help a surgeon's understanding about the cervical pedicle more precisely than the other two techniques. The funnel technique is less dependent on lateral soft tissue retraction state.

Lumbo-sacro-pelvic Fixation Using Iliac Screws for the Complex Lumbo-sacral Fractures

  • Rhee, Woo-Tack;You, Seung-Hoon;Jang, Yeon-Gyu;Lee, Sang-Youl
    • Journal of Korean Neurosurgical Society
    • /
    • 제42권6호
    • /
    • pp.495-498
    • /
    • 2007
  • Fractures of lumbo-sacral junction involving bilateral sacral wings are rare. Posterior lumbo-sacral fixation does not always provide with sufficient stability in such cases. Various augmentation techniques including divergent sacral ala screws, S2 pedicle screws and Galveston rods have been reported to improve lumbo-sacral stabilization. Galveston technique using iliac bones would be the best surgical approach especially in patients with bilateral comminuted sacral fractures. However, original Galveston surgery is technically demanding and bending rods into the appropriate alignment is time consuming. We present a patient with unstable lumbo-sacral junction fractures and comminuted U-shaped sacral fractures treated by lumbo-sacro-pelvic fixation using iliac screws and discuss about the advantages of the iliac screws over the rod system of Galveston technique.

A Biomechanical Comparison of Intralaminar C7 Screw Constructs with and without Offset Connector Used for C6-7 Cervical Spine Immobilization : A Finite Element Study

  • Qasim, Muhammad;Hong, Jae Taek;Natarajan, Raghu N.;An, Howard S.
    • Journal of Korean Neurosurgical Society
    • /
    • 제53권6호
    • /
    • pp.331-336
    • /
    • 2013
  • Objective : The offset connector can allow medial and lateral variability and facilitate intralaminar screw incorporation into the construct. The aim of this study was to compare the biomechanical characteristics of C7 intralaminar screw constructs with and without offset connector using a three dimensional finite element model of a C6-7 cervical spine segment. Methods : Finite element models representing C7 intralaminar screw constructs with and without the offset connector were developed. Range of motion (ROM) and maximum von Mises stresses in the vertebra for the two techniques were compared under pure moments in flexion, extension, lateral bending and axial rotation. Results : ROM for intralaminar screw construct with offset connector was less than the construct without the offset connector in the three principal directions. The maximum von Misses stress was observed in the C7 vertebra around the pedicle in both constructs. Maximum von Mises stress in the construct without offset connector was found to be 12-30% higher than the corresponding stresses in the construct with offset connector in the three principal directions. Conclusion : This study demonstrated that the intralaminar screw fixation with offset connector is better than the construct without offset connector in terms of biomechanical stability. Construct with the offset connector reduces the ROM of C6-7 segment more significantly compared to the construct without the offset connector and causes lower stresses around the C7 pedicle-vertebral body complex.

Comparative Analysis of Surgical Outcomes of C1-2 Fusion Spine Surgery between Intraoperative Computed Tomography Image Based Navigation-Guided Operation and Fluoroscopy-Guided Operation

  • Lee, Jun Seok;Son, Dong Wuk;Lee, Su Hun;Ki, Sung Soon;Lee, Sang Weon;Song, Geun Sung
    • Journal of Korean Neurosurgical Society
    • /
    • 제63권2호
    • /
    • pp.237-247
    • /
    • 2020
  • Objective : Fixation of the C1-2 segment is challenging because of the complex anatomy in the region and the need for a high degree of accuracy to avoid complications. Preoperative 3D-computed tomography (CT) scans can help reduce the risk of complications in the vertebral artery, spinal cord, and nerve roots. However, the patient may be susceptible to injury if the patient's anatomy does not match the preoperative CT scans. The intraoperative 3D image-based navigation systems have reduced complications in instrument-assisted techniques due to greater accuracy. This study aimed to compare the radiologic outcomes of C1-2 fusion surgery between intraoperative CT image-guided operation and fluoroscopy-guided operation. Methods : We retrospectively reviewed the radiologic images of 34 patients who underwent C1-2 fusion spine surgery from January 2009 to November 2018 at our hospital. We assessed 17 cases each of degenerative cervical disease and trauma in a study population of 18 males and 16 females. The mean age was 54.8 years. A total of 139 screws were used and the surgical procedures included 68 screws in the C1 lateral mass, 58 screws in C2 pedicle, nine screws in C2 lamina and C2 pars screws, four lateral mass screws in sub-axial level. Of the 34 patients, 19 patients underwent screw insertion using intraoperative mobile CT. Other patients underwent atlantoaxial fusion with a standard fluoroscopy-guided device. Results : A total of 139 screws were correctly positioned. We analyzed the positions of 135 screws except for the four screws that performed the lateral mass screws in C3 vertebra. Minor screw penetration was observed in seven cases (5.2%), and major pedicle screw penetration was observed in three cases (2.2%). In one case, the malposition of a C2 pedicle screw was confirmed, which was subsequently corrected. There were no complications regarding vertebral artery injury or onset of new neurologic deficits. The screw malposition rate was lower (5.3%) in patients who underwent intraoperative CT-based navigation than that for fluoroscopy-guided cases (10.2%). And we confirmed that the operation time can be significantly reduced by surgery using intraoperative O-arm device. Conclusion : Spinal navigation using intraoperative cone-beam CT scans is reliable for posterior fixation in unstable C1-2 pathologies and can be reduced the operative time.

후방경유 요추 융합수술시 척추후관절낭 손상의 운동역학적 영향 (Biomechanical Effects of Facet Capsule Injuries in Posterior Lumbar Fusion Operations)

  • 박승원;김영백;황성남;최덕영;권정택;민병국;석종식
    • Journal of Korean Neurosurgical Society
    • /
    • 제30권3호
    • /
    • pp.358-365
    • /
    • 2001
  • Objectives : Although posterior lumbar fusion operations had been reported to accelerate spinal degeneration, there have been only a few studies for their biomechanical effects. We have studied the change of motion range at the vertebral joint one level above the fusion(UVJ) in pedicle screw fixation group(PSF)(n=13) where facet capsule was destroyed and in posterior lumbar interbody fusion group(PLIF)(n=8) where it was spared. Patients and Methods : The patients were divided into early(3 to 6 months) and late(over 12 months) according to postoperative follow-up period. The flexion, extension and flexion-extension angles(FA, EA, FEA) were measured at the UVJ with pre-operative, early and late post-operative films. Results : Mean age and male to female ratio were $52.7{\pm}9.3$ and 1 : 3.2. Mean follow-up periods were $144.1{\pm}30.0$ and $528.8{\pm}160.3$ days in early and late groups, respectively. The FEA and FA in the late PSF($11.8{\pm}3.1$, $8.5{\pm}2.9$) were significantly greater than pre-operative angles($7.8{\pm}3.9$, $5.1{\pm}3.7$)(p<0.01, p<0.05). All angles in the PLIF showed no significant changes with time. The FEA and FA in the late PSF($11.8{\pm}3.1$, $8.5{\pm}2.9$) were significantly greater than those of the late PLIF($7.6{\pm}2.3$, $3.4{\pm}2.0$)(p<0.01, p<0.001). All angles at early follow-up period were similar between PSF and PLIF. The EA showed no significant change in relation with follow-up period or fusion method. Conclusion : As a result, the facet capsule injury in pedicle screw fixation seems to be related with increased flexion angle or degeneration of the adjacent joint above the fused vertebra in the late phase.

  • PDF

Troublesome Occipital Neuralgia Developed by C1-C2 Harms Construct

  • Rhee, Woo-Tack;You, Seung-Hoon;Kim, Suk-Kyoung;Lee, Sang-Youl
    • Journal of Korean Neurosurgical Society
    • /
    • 제43권2호
    • /
    • pp.111-113
    • /
    • 2008
  • Recently, Harms and Melcher modified Goel's approach, the C1 lateral mass and C2 pedicle screw fixation, and the new technique is currently in favor among neurosurgeons. Comparing to the advantages of Harms construct, the disadvantages were not extensively investigated. We experienced a patient with severe occipital pain developed after the C1 lateral mass screw placement for the traumatic atlantoaxial instability. We reviewed literatures about Harms construct with focus on the occipital neuralgia as a postoperative complication and suggest here technical tips to avoid the troublesome pain.

척추경 나사못 고정술 시행 후 3차원 재구성CT영상의 유용성 평가 (Evaluation on usefulness of three dimensional reconstructive computed tomography images after pedicle screws fixation)

  • 김현주;장현철;조재환
    • 디지털콘텐츠학회 논문지
    • /
    • 제11권4호
    • /
    • pp.553-559
    • /
    • 2010
  • 본 연구는 척추경 나사못 고정술을 시행한 환자를 대상으로 고정술 전, 후 전산화 단층촬영 영상의 원 자료(raw data)를 이용하여 다양한 재구성 기법을 적용하여 나사못의 정확한 위치파악과 수술의 정확도 등 다양한 정보를 알아보고자 하였다. 임상에서 주로 이용 하는 재구성기법인 다평면재구성(MPR), 최대강도투영(MIP), 체적묘사기법(VRT)과 변형 제적묘사기법(modifying VRT)을 적용하여 영상데이터를 각 각 정량적 방법과 정성적 방법으로 비교 분석하였다. 재구성 영상의 분석 및 평가결과 전산화 단층촬영 영상재구성 기법 중 척추경 나사못 고정술 후 나사의 정확한 위치파악과 금속에 의한 인공음영을 최소화 시키는데 가장 유용한 재구성 기법으로는 변형 체적묘사기법으로 사료된다.