• Title/Summary/Keyword: Pedicle Screw

Search Result 128, Processing Time 0.023 seconds

Biomechanical Effects of Facet Capsule Injuries in Posterior Lumbar Fusion Operations (후방경유 요추 융합수술시 척추후관절낭 손상의 운동역학적 영향)

  • Park, Seung Won;Kim, Young Baeg;Hwang, Sung Nam;Choi, Duck Young;Kwon, Jeong Taik;Min, Byung Kook;Suk, Jong Sik
    • Journal of Korean Neurosurgical Society
    • /
    • v.30 no.3
    • /
    • pp.358-365
    • /
    • 2001
  • Objectives : Although posterior lumbar fusion operations had been reported to accelerate spinal degeneration, there have been only a few studies for their biomechanical effects. We have studied the change of motion range at the vertebral joint one level above the fusion(UVJ) in pedicle screw fixation group(PSF)(n=13) where facet capsule was destroyed and in posterior lumbar interbody fusion group(PLIF)(n=8) where it was spared. Patients and Methods : The patients were divided into early(3 to 6 months) and late(over 12 months) according to postoperative follow-up period. The flexion, extension and flexion-extension angles(FA, EA, FEA) were measured at the UVJ with pre-operative, early and late post-operative films. Results : Mean age and male to female ratio were $52.7{\pm}9.3$ and 1 : 3.2. Mean follow-up periods were $144.1{\pm}30.0$ and $528.8{\pm}160.3$ days in early and late groups, respectively. The FEA and FA in the late PSF($11.8{\pm}3.1$, $8.5{\pm}2.9$) were significantly greater than pre-operative angles($7.8{\pm}3.9$, $5.1{\pm}3.7$)(p<0.01, p<0.05). All angles in the PLIF showed no significant changes with time. The FEA and FA in the late PSF($11.8{\pm}3.1$, $8.5{\pm}2.9$) were significantly greater than those of the late PLIF($7.6{\pm}2.3$, $3.4{\pm}2.0$)(p<0.01, p<0.001). All angles at early follow-up period were similar between PSF and PLIF. The EA showed no significant change in relation with follow-up period or fusion method. Conclusion : As a result, the facet capsule injury in pedicle screw fixation seems to be related with increased flexion angle or degeneration of the adjacent joint above the fused vertebra in the late phase.

  • PDF

Feasibility of Bilateral Crossing C7 Intralaminar Screws : A Cadaveric Study

  • Baek, Tae-Hyun;Kim, Ilsup;Hong, Jae-Taek;Kim, Daniel H.;Shin, Dongsuk;Lee, Sang-Won
    • Journal of Korean Neurosurgical Society
    • /
    • v.56 no.1
    • /
    • pp.5-10
    • /
    • 2014
  • Objective : When the pedicle screw insertion technique is failed or not applicable, C7 intralaminar screw insertion method has been used as an alternative or salvage fixation method recently. However, profound understanding of anatomy is required for safe application of the bilaterally crossing laminar screw at C7 in clinic. In this cadaveric study, we evaluated the anatomic feasibility of the bilateral crossing intralaminar screw insertion and especially focused on determination of proper screw entry point. Methods : The C7 vertebrae from 18 adult specimens were studied. Morphometric measurements of the mid-laminar height, the minimum laminar thickness, the maximal screw length, and spino-laminar angle were performed and cross-sectioned vertically at the screw entry point (spino-laminar junction). The sectioned surface was equally divided into 3 parts and maximal thickness and surface area of the parts were measured. All measurements were obtained bilaterally. Results : The mean mid-laminar height was 13.7 mm, mean minimal laminar thickness was 6.6 mm, mean maximal screw length was 24.6 mm, and mean spinolaminar angle was $50.8{\pm}4.7^{\circ}$. Based on the measured laminar thickness, the feasibility of 3.5 mm diameter intralaminar screw application was 83.3% (30 sides laminae out of total 36) when assuming a tolerance of 1 mm on each side. Cross-sectional measurement results showed that the mean maximal thickness of upper, middle, and lower thirds was 5.0 mm, 7.5 mm, and 7.3 mm, respectively, and mean surface area for each part was $21.2mm^2$, $46.8mm^2$, and $34.7mm^2$, respectively. Fourteen (38.9%) sides of laminae would be feasible for 3.5 mm intralaminar screw insertion when upper thirds of C7 spino-laminar junction is the screw entry point. In case of middle and lower thirds of C7 spino-laminar junction, 32 (88.9%) and 28 (77.8%) sides of laminae were feasible for 3.5 mm screw insertion, respectively. Conclusion : The vertical cross-sectioned area of middle thirds at C7 spinolaminar junction was the largest area and 3.5 mm screw can be accommodated with 77.8 % of feasibility when lower thirds were the screw entry point. Thus, selection of middle and lower thirds for each side of screw entry point in spino-laminar junction would be the safest way to place bilateral crossing laminar screw within the entire lamina. This anatomic study result will help surgeons to place the screw safely and accurately.

Surgical Treatment of Osteoporotic Vertebral Compression Fractures at Thoraco-Lumbar Levels: Only Pedicle Screw Constructs with Polymethylmethacrylate Augmentation (흉요추부 골다공증성 척추 압박 골절의 수술적 치료: 골시멘트 보강술을 이용한 척추경 나사 고정)

  • Jun, Deuk Soo;Baik, Jong-Min;Park, Ji Hyeon
    • Journal of the Korean Orthopaedic Association
    • /
    • v.54 no.4
    • /
    • pp.327-335
    • /
    • 2019
  • Purpose: To investigate the radiological efficacy of polymethylmethacrylate (PMMA) augmentation of pedicle screw operation in osteoporotic vertebral compression fractures (OVCF) patients. Materials and Methods: Twenty OVCF patients, who underwent only posterior fusion using pedicle screws with PMMA augmentation, were included in the study. The mean follow-up period was 15.6 months. The demographic data, bone mineral density (BMD), fusion segments, number of pedicle screws, and amount of PMMA were reviewed as medical records. To analyze the radiological outcomes, the radiologic parameters were measured as the time serial follow-up (preoperation, immediately postoperation, postoperation 6 weeks, 3, 6 months, and 1 year follow-up). Results: A total of 20 patients were examined (16 females [80.0%]; mean age, 69.1±8.9 years). The average BMD was -2.5±0.9 g/cm2. The average cement volume per vertebral body was 6.3 ml. The mean preoperative Cobb angle of focal kyphosis was 32.7°±7.0° and was improved significantly to 8.7°±6.9° postoperatively (p<0.001), with maintenance of the correction at the serial follow-up, postoperatively. The Cobb angle of instrumented kyphosis, wedge angle, and sagittal index showed similar patterns. In addition, the anterior part of fractured vertebral body height averaged 11.0±5.0 mm and was improved to 18.5±5.7 mm postoperatively (p=0.006), with maintenance of the improvement at the 3-month, 6-month, and 1-year follow-up. Conclusion: The reinforcement of pedicle screws using PMMA augmentation may be a feasible surgical technique for OVCF. Moreover, it appears to be appropriate for improving the focal thoracolumbar/lumbar kyphosis and is maintained well after surgery.

Correction of Single Thoracic Adolescent Idiopathic Scoliosis Using Pedicle Screw Instrumentation: Comparison of Stainless Steel to Titanium Alloy Instruments (척추경 나사못 고정술을 이용한 단일 흉추 청소년기 특발성 척추 측만증의 치료: 스테인리스강과 티타늄 합금 기기의 비교)

  • Kim, Sung-Soo;Lim, Dong-Ju;Kim, Jung-Hoon;Choi, Byung-Wan;Kim, Hwi-Young;Lee, Jun-Seok
    • Journal of the Korean Orthopaedic Association
    • /
    • v.54 no.2
    • /
    • pp.141-149
    • /
    • 2019
  • Purpose: To compare the results of two different instruments made of stainless steel and titanium alloy for correction of single thoracic adolescent idiopathic scoliosis (AIS) using pedicle screw instrumentation. Materials and Methods: A total of 141 patients with single thoracic AIS treated with pedicle screw instrumentation and selective thoracic fusion were retrospectively reviewed after a follow-up of 2 years. The patients had a main thoracic curve of 40° to 75° and were divided into two groups based on instrument materials; S group (stainless steel, n=90) and T group (titanium alloy, n=51). The diameter of the stainless steel rod used was 7.0 mm while that of the titanium alloy rod was 6.35 mm or 6.0 mm. Standing long-cassette radiographic measurements including various coronal and sagittal parameters for the preoperative, early postoperative and 2-year postoperative followup were analyzed. There were no significant differences in the preoperative curve characteristics between the two groups. Results: In the S group, the preoperative main thoracic curve of 51.3°±8.4° was improved to 19.0°±7.6° (63.1% correction) and the lumbar curve of 32.3°±8.4° spontaneously decreased to 12.7°±8.2° (62.9% correction) at 2 years postoperatively. In the T group, the preoperative main thoracic curve of 49.5°±8.4° and the lumbar curve of 30.3°±8.9° was improved to 18.8°±7.4° (62.2% correction) and 11.3°±5.4° (63.3% correction), respectively. The corrections of coronal curves were not statistically different between the two groups (p>0.05). The thoracic kyphosis was changed from 16.8°±8.5° to 24.3°±6.1° in the S group and from 19.6°±11.2° to 26.6°±8.5° in the T group. There were no significant differences in the changes of sagittal curves, coronal and sagittal balances at the 2-year follow-up and the number of fused segments and used screws between the two groups (p>0.05). Conclusion: When conducting surgery for single thoracic AIS using pedicles screw instrumentation, two different instruments made of stainless steel and titanium alloy showed similar corrections for coronal and sagittal curves.

Biomechanical Efficacy of a Combined Flexible Cage with Pedicle Screws with Spring rods: A Finite Element Analysis (Spring rod를 사용한 척추경 나사못과 동반 시술된 Flexible cage의 생체역학적 효과)

  • Kim, Y.H.;Park, E.Y.;Kim, W.H.;Hwang, S.P.;Park, K.W.;Lee, Sung-Jae
    • Journal of Biomedical Engineering Research
    • /
    • v.38 no.1
    • /
    • pp.9-15
    • /
    • 2017
  • Recently, flexible cages have been introduced in an attempt to absorb and reduce the abnormal load transfer along the anterior parts of the spine. They are designed to be used with the pedicle screw systems to allow some mobility at the index level while containing ROM at the adjacent level. In this study, a finite element (FE) study was performed to assess biomechanical efficacies of the flexible cage when combined with pedicle screws with flexible rods. The post-operated models were constructed by modifying the L4-5 of a previously-validated 3-D FE model of the intact lumbar spine (L2-S1): (1) Type 1, flexible cage only; (2) Type 2, pedicle screws with flexible rods; (3) Type 3, interbody fusion cage plus pedicle screws with rigid rods; (4) Type 4, interbody fusion cage plus Type 2; (5) Type 5, Type 1 plus Type 2. Flexion/extension of 10 Nm with a compressive follower load of 400N was applied. As compared to the Type 3 (62~65%) and Type 4 (59~62%), Type 5 (53~55%) was able to limit the motion at the operated level effectively, despite moderate reduction at the adjacent level. It was also able to shift the load back to the anterior portions of the spine thus relieving excessively high posterior load transfer and to reduce stress on the endplate by absorbing the load with its flexible shape design features. The likelihood of component failure of flexble cage remained less than 30% regardless of loading conditions when combined with pedicle screws with flexible rods. Our study demonstrated that flexible cages when combined with posterior dynamic system may help reduce subsidence of cage and degeneration process at the adjacent levels while effectively providing stability at the operated level.

Anterior and Posterior Stabilization by One Stage Posterolateral Approach in the Unstable Fracture of Thoracolumbar and Lumbar Spine

  • Lee, Young-Min;Cho, Yang-Woon;Kim, Joon-Soo;Kim, Kyu-Hong;Lee, In-Chang;Bae, Sang-Do
    • Journal of Korean Neurosurgical Society
    • /
    • v.40 no.1
    • /
    • pp.22-27
    • /
    • 2006
  • Objective : The purpose of this study is to investigate the clinical results of anterior and posterior stabilization by one stage posterolateral approach for the unstable fracture of thoracolumbar and lumbar spine. Methods : By posterolateral approach with curved skin incision, unilateral facet and pedicle were removed. Through this route, corpectomy was performed, and then this space was replaced with mesh cage filled up with autologous bone graft. Both side pedicle screw fixation was followed to upper and lower levels. Results : Six of seven patients of this study showed neurological improvement. The other one patient showed no neurological change. One patient had postoperative infection, another patient had postoperative kyphosis. The other patient had epidural hematoma on operation site after surgery. And all patinets on this study made to have spinal stability except one patient happened postoperative kyphosis. Conclusion : In the unstable fracture of thoracolumbar and lumbar spine, one stage anterior and posterior stabilization and fusion by posterolateral approach seems to be an effective procedure, if we have more care and supplementation.

NFlex Dynamic Stabilization System : Two-Year Clinical Outcomes of Multi-Center Study

  • Coe, Jeffrey D.;Kitchel, Scott H.;Meisel, Hans Jorg;Wingo, Charles H.;Lee, Soo-Eon;Jahng, Tae-Ahn
    • Journal of Korean Neurosurgical Society
    • /
    • v.51 no.6
    • /
    • pp.343-349
    • /
    • 2012
  • Objective : Pedicle-based dynamic stabilization systems, in which semi-rigid rods or cords are used to restrict or control spinal segmental motion, aim to reduce or eliminate the drawbacks associated with rigid fusion. In this study, we analyzed the two-year clinical outcomes of patients treated with the NFlex (Synthes Spine, Inc.), a pedicle-based dynamic stabilization system. Methods : Five sites participated in a retrospective study of 72 consecutive patients who underwent NFlex stabilization. Of these 72 patients, 65 were available for 2-year follow-up. Patients were included based on the presence of degenerative disc disease (29 patients), degenerative spondylolisthesis (16 patients), lumbar stenosis (9 patients), adjacent segment degeneration (6 patients), and degenerative lumbar scoliosis (5 patients). The clinical outcome measures at each assessment were Visual Analogue Scale (VAS) to measure back pain, and Oswestry Disability Index (ODI) to measure functional status. Radiographic assessments included evidence of instrumentation failure or screw loosening. Results : Sixty-five patients (26 men and 39 women) with a mean age of 54.5 years were included. Mean follow-up was 25.6 months. The mean VAS score improved from 8.1 preoperatively to 3.8 postoperatively, representing a 53% improvement, and the ODI score from 44.5 to 21.8, representing a 51% improvement. Improvements in pain and disability scores were statistically significant. Three implant-related complications were observed. Conclusion : Posterior pedicle-based dynamic stabilization using the NFlex system seems effective in improving pain and functional scores, with sustained clinical improvement after two years. With appropriate patient selection, it may be considered an effective alternative to rigid fusion.

Evaluation on usefulness of three dimensional reconstructive computed tomography images after pedicle screws fixation (척추경 나사못 고정술 시행 후 3차원 재구성CT영상의 유용성 평가)

  • Kim, Hyeon-Ju;Jang, Hyun-Chul;Cho, Jae-Hwan
    • Journal of Digital Contents Society
    • /
    • v.11 no.4
    • /
    • pp.553-559
    • /
    • 2010
  • By applying the various reformation techniques by using a circle raw data of after computed tomography image in the patient enforcing the spine screw fixation, this research tried to look into the various information including the exact location of the position of the screw spike and accuracy of an operation. In a clinical, by applying the or multi planar reformatting(MPR), that is the re-composition technique used mainly, maximum intensity projection (MIP), and volume rendering technique(VRT) and transformation removal from a register modifying VRT, video data were compared and were analyzed by the quantitative method and qualitative method. It is judged as the transformation volume rendering technique of the re-composition technique which is most useful in minimizing the artifact shadow by the exact location of the position of a screw and metal among the analysis and evaluation result computed tomography image reformation technique of the reformation image after the spine screw fixation.

The Effect of Postoperative Use of Teriparatide Reducing Screw Loosening in Osteoporotic Patients

  • Kim, Jae Wook;Park, Seung Won;Kim, Young Baeg;Ko, Myeong Jin
    • Journal of Korean Neurosurgical Society
    • /
    • v.61 no.4
    • /
    • pp.494-502
    • /
    • 2018
  • Objective : The loosening of pedicle screws (PS) is one of the frequent problems of spinal surgery in the patients with osteoporosis. Previous studies had revealed that intermittent injection of teriparatide could reduce PS loosening by improving bone mass and quality when their patients took parathyroid hormone for a considerable duration before surgery. However, although the teriparatide is usually used after spine surgery in most clinical situations, there was no report on the efficacy of teriparatide treatment started after spine surgery. The purpose of this retrospective study was to examine the efficacy of teriparatide treatment started immediately after lumbar spinal surgery to prevent pedicle screw loosening in patients with osteoporosis. Methods : We included 84 patients with osteoporosis and degenerative lumbar disease who underwent transforaminal interbody fusion and PS fixation and received parathyroid hormone or bisphosphonate (BP) postoperatively. They were divided into teriparatide group (daily injection of $20{\mu}g$ of teriparatide for 6 months, 33 patients, 172 screws) and BP group (weekly oral administration of 35 mg of risedronate, 51 patients, 262 screws). Both groups received calcium (500 mg/day) and cholecalciferol (1000 IU/day) together. The screw loosening was evaluated with simple radiographic exams at 6 and 12 months after the surgery. We counted the number of patients with PS loosening and the number of loosened PS, and compared them between the two groups. Clinical outcomes were evaluated using visual analog scale (VAS) and Oswestry disability index (ODI) preoperatively, and at 12 months after surgery. Results : There was no significant difference in the age, sex, diabetes, smoking, bone mineral density, body mass index, and the number of fusion levels between the two groups. The number of PS loosening within 6 months after surgery did not show a significant difference between the teriparatide group (6.9%, 12/172) and the BP group (6.8%, 18/272). However, during 6-12 months after surgery, it was significantly lower in the teriparatide group (2.3%, 4/172) than the BP group (9.2%, 24/272) (p<0.05). There was no significant difference in the number of patients showing PS loosening between the teriparatide and BP groups. The teriparatide group showed a significantly higher degree of improvement of the bone mineral density (T-score) than that of BP group (p<0.05). There was no significant difference in the pre- and post-operative VAS and ODI between the groups. Conclusion : Our data suggest that the teriparatide treatment starting immediately after lumbar spinal fusion surgery could reduce PS loosening compared to BP.

Correction of Spondylolisthesis by Lateral Lumbar Interbody Fusion Compared with Transforaminal Lumbar Interbody Fusion at L4-5

  • Ko, Myeong Jin;Park, Seung Won;Kim, Young Baeg
    • Journal of Korean Neurosurgical Society
    • /
    • v.62 no.4
    • /
    • pp.422-431
    • /
    • 2019
  • Objective : In an aging society, the number of patients with symptomatic degenerative spondylolisthesis (DS) is increasing and there is an emerging need for fusion surgery. However, few studies have compared transforaminal lumbar interbody fusion (TLIF) and lateral lumbar interbody fusion (LLIF) for the treatment of patients with DS. The purpose of this study was to investigate the clinical and radiological outcomes between TLIF and LLIF in DS. Methods : We enrolled patients with symptomatic DS at L4-5 who underwent TLIF with open pedicle screw fixation (TLIF group, n=41) or minimally invasive LLIF with percutaneous pedicle screw fixation (LLIF group, n=39) and were followed-up for more than one year. Clinical (visual analog scale and Oswestry disability index) and radiological outcomes (spondylolisthesis rate, segmental sagittal angle [SSA], mean disc height [MDH], intervertebral foramen height [FH], cage subsidence, and fusion rate) were assessed. And we assessed the changes in radiological parameters between the postoperative and the last follow-up periods. Results : Preoperative radiological parameters were not significantly different between the two groups. LLIF was significantly superior to TLIF in immediate postoperative radiological results, including reduction of spondylolisthesis rate (3.8% and 7.2%), increase in MDH (13.9 mm and 10.3 mm) and FH (21.9 mm and 19.4 mm), and correction of SSA ($18.9^{\circ}$ and $15.6^{\circ}$) (p<0.01), and the changes were more stable from the postoperative period to the last follow-up (p<0.01). Cage subsidence was observed significantly less in LLIF (n=6) than TLIF (n=21). Fusion rate was not different between the two groups. The clinical outcomes did not differ significantly at any time point between the two groups. Complications were not statistically significant. However, TLIF showed chronic mechanical problems with screw loosening in four patients and LLIF showed temporary symptoms associated with the surgical approach, such as psoas and ileus muscle symptoms in three and two cases, respectively. Conclusion : LLIF was more effective than TLIF for spondylolisthesis reduction, likely due to the higher profile cage and ligamentotactic effect. In addition, LLIF showed mechanical stability of the reduction level by using a cage with a larger footprint. Therefore, LLIF should be considered a surgical option before TLIF for patients with unstable DS.