• 제목/요약/키워드: Pediatric X-ray

검색결과 197건 처리시간 0.026초

자동 뼈 연령 평가를 위한 비전 트랜스포머와 손 X 선 영상 분석 (Unleashing the Potential of Vision Transformer for Automated Bone Age Assessment in Hand X-rays)

  • 정경희;;;추현승
    • 한국정보처리학회:학술대회논문집
    • /
    • 한국정보처리학회 2023년도 춘계학술발표대회
    • /
    • pp.687-688
    • /
    • 2023
  • Bone age assessment is a crucial task in pediatric radiology for assessing growth and development in children. In this paper, we explore the potential of Vision Transformer, a state-of-the-art deep learning model, for bone age assessment using X-ray images. We generate heatmap outputs using a pre-trained Vision Transformer model on a publicly available dataset of hand X-ray images and show that the model tends to focus on the overall hand and only the bone part of the image, indicating its potential for accurately identifying the regions of interest for bone age assessment without the need for pre-processing to remove background noise. We also suggest two methods for extracting the region of interest from the heatmap output. Our study suggests that Vision Transformer holds great potential for bone age assessment using X-ray images, as it can provide accurate and interpretable output that may assist radiologists in identifying potential abnormalities or areas of interest in the X-ray image.

소아 환자에서 방사선 차폐체로 인한 피폭선량과 화질의 변화 (Changes in Exposure Dose and Image Quality due to Radiation Shielding in Pediatric Patients)

  • 이영희;이용기
    • 한국방사선학회논문지
    • /
    • 제14권7호
    • /
    • pp.931-936
    • /
    • 2020
  • 본 연구는 자동노출선량장치을 사용했을 때 생식선 차폐체의 유무와 크기 변화에 따른 소아 환자의 방사선 피폭선량과 화질의 변화를 관찰하기 위하여 수행되었다. X-ray 장비를 이용하여 소아 팬텀의 복부와 생식선에서 차폐체가 없을 때와 3가지 크기의 차폐체를 사용했을 때의 방사선 피폭선량을 측정하였으며, 얻어진 영상을 통하여 SNR과 CNR을 측정하였다. 연구 결과 방사선 차폐체의 크기에 비례하여 생식선의 방사선 피폭선량은 감소하였으나 복부의 방사선 피폭선량은 오히려 증가되는 것으로 나타났으며 화질의 변화는 나타나지 않았다. AEC System 사용으로 인하여 방사선 차폐체로 인하여 증가된 방사선으로 인하여과 피폭되지 않도록 소아 환자의 연령과 몸무게, 신체 크기에 최적화된 크기의 차폐체를 사용하는 것이 효과적이라는 것을 확인할 수 있었다.

소아 X선 촬영에서 청각과 시각의 환경변화에 따른 유용성 평가 (Evaluation of Usefulness according to Environmental Change of Auditory and Visual in Pediatric X-ray)

  • 백성욱;송종남;김정훈;한재복
    • 한국방사선학회논문지
    • /
    • 제11권7호
    • /
    • pp.605-610
    • /
    • 2017
  • 성인과 달리 소아의 경우 인지능력과 의사전달이 정확하지 않아 X선 검사에 있어 심리적 불안감으로 인한 움직임은 재검사를 증가시키는 요인 중 하나이다. X선 검사라는 거부감을 최소화하고 의료 서비스의 만족도를 향상하기 위한 방법으로 검사실의 환경을 개선하여 심리적 안정에 도움을 주어 검사과정에서 발생하는 불필요한 재검사를 비롯한 피폭선량 절감에 긍정적인 방안을 알아보고자 하였다. 실험대상으로는 2017년 5월부터 2017년 8월까지 본원 일반촬영실에서 만 6개월 이상~만 36개월 미만의 총 186명의 소아를 대상으로 청각과 시각적 환경변화를 모두 적용시키지 않는 평소 검사실을 A 군, 시각적 환경변화는 제외시키고 청각적 환경변화만 적용한 검사실을 B 군, 청각적 환경변화는 제외시키고 시각적 환경변화만 적용한 검사실을 C 군, 청각과 시각적 환경변화를 모두 적용한 검사실을 D 군으로 설정하여 연구를 진행하였다. A 군에서는 재검사 건수가 10건, B 군 7건, C 군 5건, D 군 2건의 결과를 도출할 수 있었다. 특히 A 군과 D 군에서 통계학적 유의수준 p<0.053으로 유의 하다는 결과를 얻을 수 있었다. 결론적으로 청각과 시각적 환경변화가 소아 심리적 안정에 많은 영향을 미쳤으며, 재검사 건수도 감소하여 의료서비스의 질적 향상 보였다.

Clinical Comparison of the Predictive Value of the Simple Skull X-Ray and 3 Dimensional Computed Tomography for Skull Fractures of Children

  • Kim, Young-Im;Cheong, Jong-Woo;Yoon, Soo Han
    • Journal of Korean Neurosurgical Society
    • /
    • 제52권6호
    • /
    • pp.528-533
    • /
    • 2012
  • Objective : In the pediatric population the skull has not yet undergone ossification and it is assumed that the diagnostic rate of skull fractures by simple X-rays are lower than that of adults. It has been recently proposed that the diagnostic rates of skull fractures by 3-dimensional computer tomography (3D-CT) are higher than simple X-rays. The authors therefore attempted to compare the diagnostic rates of pediatric skull fractures by simple X-rays and 3D-CTs with respect to the type of fracture. Methods : One-hundred patients aged less than 12 years who visited the Emergency Center for cranial injury were subject to simple X-rays and 3D-CTs. The type and location of the fractures were compared and Kappa statistical analysis and the t-test were conducted. Results : Among the 100 pediatric patients, 65 were male and 35 were female. The mean age was $50{\pm}45$ months. 63 patients had simple skull fractures and 22 had complex fractures, and the types of fractures were linear fractures in 74, diastatic fractures 15, depressed fractures in 10, penetrating fracture in 1, and greenstick fractures in 3 patients. Statistical difference was observed for the predictive value of simple skull fractures' diagnostic rate depending on the method for diagnosis. A significant difference of the Kappa value was noted in the diagnosis of depressed skull fractures and diastatic skull fractures. Conclusion : In the majority of pediatric skull fractures, 3D-CT showed superior diagnosis rates compared to simple skull X-rays and therefore 3D-CT is recommended whenever skull fractures are suspected. This is especially true for depressed skull fractures and diastatic skull fractures.

자체 제작한 호흡 동기화 장치를 통한 흉부 일반촬영 검사의 호흡 재현성 평가 (Evaluation of Respiration Reproducibility of Chest General X-ray Examination using Self-made Respiratory Synchronization Device)

  • 권오영;이창훈;용금주;진선희;정다빈;허영철
    • 한국방사선학회논문지
    • /
    • 제15권7호
    • /
    • pp.1049-1056
    • /
    • 2021
  • 본 연구의 목적은 일반촬영용 호흡 동기화 장치를 개발하여 호흡 협조가 어려운 환자의 가슴 검사를 할 때 들숨의 재현성을 높이는 것이다. 공기압 센서를 이용하여 호흡 동기화 장치를 자체 제작(X-RSD)하였고, 심폐소생술용 마네킹에 벤틸레이터를 연결하여 공기를 주입하였다. 이때 주입한 공기의 양은 SkillReporting 장치를 이용하여 정량화하였다. 마네킹의 가슴에 X-RSD를 위치한 후 공기의 양을 200-700 cc까지 100 cc 씩 총 6 단계를 나눠서 검사하였다. 오차 평가는 총 80회씩 반복 측정하여 X-RSD의 민감도를 측정하였고 민감도는 100%로 매우 정교한 결과 값을 얻을 수 있었다. 이후 가슴 측면검사를 X-RSD를 보면서 검사한 영상과, 암맹 검사한 영상을 비교평가 하였고, X-RSD의 폐 용적이 암맹 검사보다 용적도 크게 측정되고, 편차도 적게 측정되었다. 종합적으로 X-RSD를 이용하면 협조가 어려운 환자의 가슴검사에 도움을 줄 수 있으며, 일반촬영의 재촬영률을 줄여 전체적인 피폭선량 감소에 기여가 가능할 것이라 사료된다.

Normal ossification of the glenoid mimicking a glenoid fracture in an adolescent patient: a case report

  • Maria Galan-Olleros;Rosa M. Egea-Gamez;Angel Palazon-Quevedo;Sergio Martinez-Alvarez;Olga M. Suarez Traba;Marta Escribano Perez
    • Clinics in Shoulder and Elbow
    • /
    • 제26권3호
    • /
    • pp.306-311
    • /
    • 2023
  • A 13-year-old male was diagnosed with a glenoid fracture following direct shoulder trauma, for which surgical treatment was considered. After referral to a center for pediatric orthopedic care, physical examination, contralateral shoulder X-ray, and detailed computed tomography examination ruled out the presence of fracture; these findings were later confirmed by magnetic resonance imaging. Normal ossification patterns in the adolescent shoulder may simulate a fracture in traumatic settings. To accurately diagnose and manage pediatric shoulder pathology, orthopedic surgeons must be aware of the normal anatomy of the growing shoulder, its secondary ossification centers, and growth plates.

요골두아탈구 환자에서 방사선 검사 시행과 연관된 인자 분석 (Factors Associated with Radiologic Tests in Patients with Radial Head Subluxation)

  • 장익완;김도균;박소영;서동범;정재윤;곽영호
    • Journal of Trauma and Injury
    • /
    • 제27권2호
    • /
    • pp.13-19
    • /
    • 2014
  • Purpose: In general, X-ray examinations are not recommended for radial head subluxation (pulled elbow) patients. The purpose of this study was to determine the frequency of X-ray examinations and to investigate the factors associated with the decision to perform an X-ray examination on a patient with a pulled elbow. Methods: Patients who visited the pediatric emergency department (ED) of one tertiary hospital from January 1, 2011, to December 31, 2012, with a diagnosis of radial head subluxation at discharge were enrolled in this study. Through retrospective chart reviews, factors that could have influenced the decision to perform an X-ray examination and their statistical relevance were analyzed. Results: A total 308 patients were enrolled, and 101 patients (32.8%) underwent X-ray examinations. Among the 252 patients with a typical pulled elbow, 65 underwent X-ray examination. This result showed statistical significance compared to atypical pull-elbow group (25.8% vs. 64.3%, p<0.001). Factors associated with the decision to perform an X-ray examination were analyzed using the Chi-square test and the Fisher's exact test. The mechanism of injury and consultation with an orthopedic surgeon (p=0.001) showed statistical significance. In the multivariable logistic regression, the odds ratio (OR) for the injury mechanism was 4.7 (95% CI: 1.8~8.8, p<0.001) and that for consultation with an orthopedic surgeon was 8.0 (95% CI: 1.6~40.7, p=0.004). Conclusion: One third of patients with a pulled elbow underwent X-ray examination, and patients with an atypical mechanism of injury underwent more frequent X-ray examinations than did patients with a typical mechanism of injury. The factors that could have influenced the decision to perform an X-ray examination were mechanism of injury and consultation with an orthopedic surgeon.

X선 촬영 시 연령별 장기선량 차이 연구 (Investigation of organ dose difference of age phantoms for medical X-ray examinations)

  • 박상현;이춘식;김우란;이재기
    • Journal of Radiation Protection and Research
    • /
    • 제28권1호
    • /
    • pp.35-42
    • /
    • 2003
  • 진단 X선 촬영에 의한 소아 및 성인의 장기 등가선량과 유효선량을 구하는 방법론을 개발하였다. 연령에 따른 체격의 차이가 방사선량 분포에 미치는 영향을 평가하기 위해, 식도를 포함한 4개 연령군의 MIRD형 수학적 모의피폭체를 제작하였다. 두 가지의 전형적인 진단 X선 절차인 흉부 PA와 복부 AP 진단 X선 촬영을 모사하여, 연령별 선량을 계산하였다. 흉부 PA 진단 X선 촬영절차에 의해서 환자들은 대략 0.03mSv의 유효선량을 피폭하는 것으로 나타났다. 복부 AP 진단 X선 촬영절차의 경우 연령에 따라서 0.4에서 1.7mSv의 유효선량을 받는 것으로 나타났다. 한정된 조사장을 갖는 방사선에 대해서 선량을 평가했기 때문에, 장기의 위치와 크기, 모양, 그리고 방사선이 입사하는 표면으로부터의 필이 등이 선량 계산에 상당한 영향을 미쳤다. 따라서 진단 X선의 조사장이나 선질의 조절 등을 통해 방호의 최적화를 위한 노력이 중요한 것으로 나타났다. 본 연구에서 개발된 선량계측 절차는 의료방사선 방호의 최적화를 위한 수단으로 활용될 수 있다.

Down the Rabbit Hole-Considerations for Ingested Foreign Bodies

  • Brown, Jerry;Kidder, Molly;Fabbrini, Abigail;deVries, Jonathan;Robertson, Jason;Chandler, Nicole;Wilsey, Michael
    • Pediatric Gastroenterology, Hepatology & Nutrition
    • /
    • 제22권6호
    • /
    • pp.619-623
    • /
    • 2019
  • We report the case of a seven-year-old boy with an ingested foreign body, which was retained within the appendix for a known duration of ten months, ultimately requiring appendectomy. The ingested foreign body was incidentally discovered by abdominal x-ray at an emergency room visit for constipation. Despite four bowel cleanouts, subsequent x-rays showed persistence of the foreign body in the right lower quadrant. While the patient did not have signs or symptoms of acute appendicitis, laparoscopic appendectomy was performed due to the risk of this foreign body causing appendicitis in the future. A small metallic object was found within the appendix upon removal. This case highlights the unique challenge presented by foreign body ingestions in non-verbal or developmentally challenged children and the importance of further diagnostic workup when concerns arise for potential retained foreign bodies.

소아 음낭 내에서 우연히 발견된 뇌실-복강 단락술 도관 1예 (An Incidentally Detected Ventriculoperitoneal Shunt Catheter in the Scrotum)

  • 문석배;이성철;정성은
    • Advances in pediatric surgery
    • /
    • 제13권2호
    • /
    • pp.212-216
    • /
    • 2007
  • Migration of a peritoneal catheter of a ventriculoperitoneal shunt into the scrotum is a rare complication. We treated a case of catheter migration in the scrotum. A 12-year old boy, who had had a ventriculoperitoneal shunt at the age of 4 months due to neonatal hydrocephalus, visited the outpatient clinic because of a right inguinal hernia. On physical examination, a firm mass was found in the left scrotum. Pelvic X-ray demonstrated a coiled catheter in the left scrotum. The catheter was successfully removed by exploring the left patent processus vaginalis after high ligation of the hernia sac. This case suggests a suction action of the patent processus vaginalis and the possibility of catheter migration long after shunt catheter insertion.

  • PDF