Reliability and validity of free software for the analysis of locomotor activity in mice

  • Hong, Yoo Rha;Moon, Eunsoo
    • Journal of Yeungnam Medical Science
    • /
    • v.35 no.1
    • /
    • pp.63-69
    • /
    • 2018
  • Background: Kinovea software that tracking semi-automatically the motion in video screen has been used to study motion-related tasks in several studies. However, the validation of this software in open field test to assess locomotor activity have not been studied yet. Therefore, this study aimed to examine the reliability and validity of this software in analyzing locomotor activities. Methods: Thirty male Institute Cancer Research mice were subjected in this study. The results examined by this software and the classical method were compared. Test-retest reliability and inter-rater reliability were analyzed with Pearson's correlation coefficient and intraclass correlation coefficient (ICC). The validity of this software was analyzed with Pearson's correlation coefficient. Results: This software showed good test-retest reliability (ICC=0.997, 95% confidence interval [CI]=0.975-0.994, p<0.001). This software also showed good inter-rater reliability (ICC=0.987, 95% CI=0.973-0.994, p<0.001). Furthermore, in three analyses for the validity of this software, there were significant correlations between two methods (Pearson's correlation coefficient=0.928-0.972, p<0.001). In addition, this software showed good reliability and validity in the analysis locomotor activity according to time interval. Conclusion: This study showed that this software in analyzing drug-induced locomotor activity has good reliability and validity. This software can be effectively used in animal study using the analysis of locomotor activity.

Correlation between Instrument on Pattern Identification for Depression and Psychological Tests by Statistical Analysis (통계적 분석을 통한 우울증 변증도구와 심리검사의 상관성 연구)

  • Kim, Hwan;Lee, Hun-Soo;Lee, Eun Jung;Park, Joon-Ho;Kang, Wee-Chang;Jung, In Chul
    • Journal of Oriental Neuropsychiatry
    • /
    • v.27 no.3
    • /
    • pp.131-146
    • /
    • 2016
  • Objectives: This study was performed to determine the correlation between Instrument on Pattern Identification for Depression and Psychological tests by Pearson Correlation Coefficient and Regression analysis.Methods: Two assessors carried out the evaluation using the instrument on pattern identification for depression. They also performed the following psychological tests: Beck Depression Inventory (BDI), State-Trait Anxiety Inventory (STAI), State-Trait Anger Expression Inventory (STAXI), the Temperament and Character Inventory (TCI), Insomnia Severity Index (ISI_Total), Self-disclosure Inventory, subjective well-being Inventory, Health perception Inventory, and Personality Assessment Inventory (PAI). A total of 167 participants who got HAM-D score over 12 were targeted for the evaluation. Our research team carried out Pearson correlation coefficient analyses and regression analysis between pattern identification for depression and Psychological tests. We listed the results by descending order and interpreted the results.Results: Pearson correlation analysis revealed the following results: 1) Stagnation of Liver Gi was associated with BDI (0.60) and STAI (0.55); 2) Dual Deficiency of the Heart and Spleen was associated with BDI (0.60), ISI_Total (0.52), and STAI (0.42); 3) Relieving stagnation of Phlegm-Gi was associated with BDI (0.65), STAI (0.54), and Subjective well-being inventory (−0.52); 4) Gi-deficiency Mingled with sputum was associated with BDI (0.50), ISI_Total (0.40), and STAI (0.395); 5) Stagnant Gi transforming into fire was associated with BDI (0.56), STAI_TR (0.51), and Health perception Inventory (−0.458); 6) Yin-Deficiency with Effulgent Fire was associated with BDI (0.55), ISI_total (0.54), and STAI (0.41).Conclusions: Through correlation analysis between Instrument on Pattern Identification for Depression and Psychological tests, we could suggest a System for Oriental Medical Diagnosis for Depression.

Identifying significant earthquake intensity measures for evaluating seismic damage and fragility of nuclear power plant structures

  • Nguyen, Duy-Duan;Thusa, Bidhek;Han, Tong-Seok;Lee, Tae-Hyung
    • Nuclear Engineering and Technology
    • /
    • v.52 no.1
    • /
    • pp.192-205
    • /
    • 2020
  • Seismic design practices and seismic response analyses of civil structures and nuclear power plants (NPPs) have conventionally used the peak ground acceleration (PGA) or spectral acceleration (Sa) as an intensity measure (IM) of an earthquake. However, there are many other earthquake IMs that were proposed by various researchers. The aim of this study is to investigate the correlation between seismic responses of NPP components and 23 earthquake IMs and identify the best IMs for correlating with damage of NPP structures. Particularly, low- and high-frequency ground motion records are separately accounted in correlation analyses. An advanced power reactor NPP in Korea, APR1400, is selected for numerical analyses where containment and auxiliary buildings are modeled using SAP2000. Floor displacements and accelerations are monitored for the non- and base-isolated NPP structures while shear deformations of the base isolator are additionally monitored for the base-isolated NPP. A series of Pearson's correlation coefficients are calculated to recognize the correlation between each of the 23 earthquake IMs and responses of NPP structures. The numerical results demonstrate that there is a significant difference in the correlation between earthquake IMs and seismic responses of non-isolated NPP structures considering low- and high-frequency ground motion groups. Meanwhile, a trivial discrepancy of the correlation is observed in the case of the base-isolated NPP subjected to the two groups of ground motions. Moreover, a selection of PGA or Sa for seismic response analyses of NPP structures in the high-frequency seismic regions may not be the best option. Additionally, a set of fragility curves are thereafter developed for the base-isolated NPP based on the shear deformation of lead rubber bearing (LRB) with respect to the strongly correlated IMs. The results reveal that the probability of damage to the structure is higher for low-frequency earthquakes compared with that of high-frequency ground motions.

Reliability of Portable Spirometry Performed in the Korea National Health and Nutrition Examination Survey Compared to Conventional Spirometry

  • Park, Hye Jung;Rhee, Chin Kook;Yoo, Kwang Ha;Park, Yong Bum
    • Tuberculosis and Respiratory Diseases
    • /
    • v.84 no.4
    • /
    • pp.274-281
    • /
    • 2021
  • Background: The Korea National Health and Nutrition Examination Survey (KNHANES) is a well-designed survey to collect national data, which many researchers have used for their studies. In KNHANES, although portable spirometry was used, its reliability has not been verified. Methods: We prospectively enrolled 58 participants from four Korean institutions. The participants were classified into normal pattern, obstructive pattern, and restrictive pattern groups according to their previous spirometry results. Lung function was estimated by conventional spirometry and portable spirometry, and the results were compared. Results: The intraclass correlation coefficients of forced vital capacity (FVC) (coefficient, 9.993; 95% confidence interval [CI], 0.988-0.996), forced expiratory volume in 1 second (FEV1) (coefficient, 0.997; 95% CI, 0.995-0.998), FEV1/FVC ratio (coefficient, 0.995; 95% CI, 0.992-0.997), and forced expiratory flow at 25-75% (FEF25-75%; coefficient, 0.991; 95% CI, 0.984-0.994) were excellent (all p<0.001). In the subgroup analysis, the results of the three parameters were similar in all groups. In the overall and subgroup analyses, Pearson's correlation of all the parameters was also excellent in the total (coefficient, 0.986-0.994; p<0.001) and subgroup analyses (coefficient, 0.915-0.995; p<0.001). In the paired t-test, FVC, FEV1/FVC, and FEF25-75% estimated by the two instruments were statistically different. However, FEV1 was not significantly different. Conclusion: Lung function estimated by portable spirometry was well-correlated with that estimated by conventional spirometry. Although the values had minimal differences between them, we suggest that the spirometry results from the KNHANES are reliable.

Development and Verification of a Simultaneous Analytical Method for Whole Blood Metals and Metalloids for Biomonitoring Programs (바이오모니터링 프로그램을 위한 혈중 금속류 동시분석법 개발 및 확인 평가)

  • Cha, Sangwon;Oh, Eunha;Oh, Selim;Han, Sang Beom;Im, Hosub
    • Journal of Environmental Health Sciences
    • /
    • v.47 no.1
    • /
    • pp.64-77
    • /
    • 2021
  • Objective: Biological monitoring of trace elements in human blood samples has become an important indicator of the health environment. The purpose of this study was to detect and evaluate multiple metal items in blood samples based on ICP-MS, to perform comparative evaluation with the existing analysis method, and to develop and verify a new method. Methods: 100 μL of whole blood from 80 healthy subjects was used to analyze ten metals (Sb, tAs, Cd, Pb, Mn, Hg, Mo, Ni, Se, Tl) using ICP-MS. Verification of the analysis method included calculation of linearity, accuracy, precision and detection limits. In addition, a comparative test with the conventional graphite furnace atomic absorption spectroscopy (GF-AAS) method was performed. In the case of Pb, Cd, and Hg in whole blood, cross-analysis between Pb, Cd, and Hg analysis methods was performed to confirm the difference between the existing method and the new method (ICP-MS). Results: The coefficient of determination (R2) was 0.999 or higher in seven items and 0.995 or higher in three items. The Pb result showed that Pearson's correlation coefficient was very high at 0.983, and the intraclass correlation coefficient was 0.966. The Cd result showed that Pearson's correlation coefficient was 0.917 between the existing method and the new analysis concentration value. Its intraclass correlation coefficient was 0.960, and there was no significant difference between the two groups. Hg had a low correlation at 0.687, and the intraclass correlation coefficient was 0.761, which was lower than that of Pb and Cd. The intra-day and inter-day accuracy of Pd and Cd were satisfactory, but Hg did not meet the criteria for both accuracy and precision when compared with the conventional analysis method. Conclusion: This study can be meaningful in that it proposes a more efficient and feasible analysis method by verifying a blood heavy metal concentration experiment using multiple simultaneous analyses. All samples were processed and analyzed using the new ICP-MS. It was confirmed that the agreement between the two methods was very high, with the agreement between the current and new methods being 0.769 to 0.998. This study proposes an efficient simultaneous methodology capable of analyzing multiple elements with small samples. In the future, studies of various applications and the reliability of ICP-MS analysis methods are required, and research on the verification of accurate, precise, and continuous analysis methods is required.

Development of the Self-Care Non-adherence Risk Assessment Scale for Patients with Chronic Illness (만성질환자의 자가간호 불이행 위험 사정도구 개발)

  • Jo, Mirae;Oh, Heeyoung
    • Research in Community and Public Health Nursing
    • /
    • v.32 no.4
    • /
    • pp.415-429
    • /
    • 2021
  • Purpose: The purpose of this study was to develop the Self-Care Non-adherence Risk Assessment Scale (SCNRAS) for patients with chronic illness in South Korea. Methods: This study was conducted from April to July, 2020 and utilized a convenience sampling method to recruit 336 patients with chronic illness from three hospitals located in South Korea. The content, factorial structure, item-convergent/discriminant validity, convergent validity, internal consistency reliability, and test-retest reliability of the scale were evaluated. The data were analyzed using exploratory and confirmatory factor analyses, Pearson's correlation coefficient, Cronbach's α, and intra-class correlation coefficient. Results: The exploratory and confirmatory factor analyses yielded six-factors. Convergent validity was demonstrated using measures of defining issues. Internal consistency reliability and test-retest reliability were found to be acceptable, as indicated by a Cronbach's α of .65~.81 and an intra-class correlation coefficient of .93~.98. The Self-Care Non-adherence Risk Assessment Scale for patients with chronic illness is a new instrument that comprehensively measures the knowledge, skill, physical function status, access to health care, social support, motivation, and confidence. It comprises 18 items scored on a 5-point Likert scale. The validity and reliability of the scale were verified. Conclusion: The scale developed through this study is expected to screen those who need nursing intervention early by predicting the self-care non-adherence risk group.

The Mechanical Properties of the Geochang Granite (거창화강암의 역학적 특성에 관한 연구)

  • Kim, Myeong Kyun
    • Tunnel and Underground Space
    • /
    • v.25 no.1
    • /
    • pp.24-36
    • /
    • 2015
  • The Geochang granite widely used in construction works is one of the most popular dimension stones in Korea. In order to evaluate the physical properties of rock, a lot of laboratory tests for the Geochang granite were conducted to find unit weight, absorption ratio, P wave velocity, S wave velocity, uniaxial compressive strength, Young's modulus, Poisson's ratio, tensile strength, cohesion, friction angle and point load strength index. The uniaxial compressive strength of the Geochang granite was 19.5 times tensile strength and also 8.6 times cohesion, besides P wave velocity was 1.5 times S wave velocity. Correlation analyses were also conducted to find the correlation among 11 different physical properties, where the uniaxial compressive strength showed Pearson correlation coefficient of more than 0.8 with Poisson's ratio, point load strength index and Young's modulus, respectively. Regression analyses were finally conducted by means of both linear and multiple analysis and the brief results including coefficient of determination of more than 0.7 were presented.

Comparison of traditional dental plaque indices with real stained plaque area (실제 착색된 치면세균막 면적과 전통적인 치면세균막 지수 비교)

  • Kim, Ji-Soo;Yang, Yong-Hoon;Jun, Eun-Joo;Kim, Jin-Bom;Jeong, Seung-Hwa
    • Journal of Korean Academy of Oral Health
    • /
    • v.41 no.4
    • /
    • pp.262-266
    • /
    • 2017
  • Objectives: The aim of this study was to compare Plaque Percent Index (PPI), calculated by Patient Hygiene Performance Index (PHPI), Rustogi's modification of the Navy Plaque Index (RMNPI), and the Quigley & Hein Plaque Index (QHPI), with visual assessment. Methods: Ninety-six subjects, aged between 30-65 years, were examined; twenty subjects were included in the final analysis. The subjects' teeth were stained and photographed. Dental coloring and intraoral camera photography were performed by a single examiner. The oral images obtained were analyzed using Image J to measure the area of dental plaque. The values of PHPI, RMNPI, and QHPI were calculated twice. Statistical analyses were performed using descriptive statistics, chi-square test, and Pearson's correlation coefficient. Results: The results of the correlation analyses of PPI with PHPI, QHPI, and RMNPI were as follows: for PHPI, the correlation coefficient (r)=0.584; for QHPI, r=0.689; and for RMNPI, r=0.729. Further, the kappa indices of PHPI, QHPI, and RMNPI were 0.810, 0.677, and 0.590 respectively. Conclusions: Among RMNPI, QHPI, and PHPI dental plaque indices, RMNPI and QHPI showed a high degree of correlation with the actual stained dental plaque area; on the other hand, PHPI showed the highest kappa index.

Reproducibility Assessment of Skin Furrows Measurement using Facial Skin Photographing System (전안촬영시스템을 이용한 주름 측정의 재현성 평가)

  • Lee, Seung-Ryun;Lee, Yun-Kyu;Park, Seo-Young;Ko, Kyoung-Mo;Lee, Yoon-Kyoung;Kim, Jae-Su;Lee, Bong-Hyo;Lim, Seong-Chul;Jung, Tae-Young;Lee, Kyung-Min
    • Journal of Acupuncture Research
    • /
    • v.25 no.1
    • /
    • pp.187-197
    • /
    • 2008
  • Objectives : The purpose of this study was to assess the reproducibility of measurement of facial skin furrows using a facial skin photographing system. Methods : Subjects were 19 patients who visited the department of acupuncture and moxsibustion, at the hospital of Oriental medical college, at Daegu Haany University for the cosmetic acupuncture treatment during August 2007 to 31th August 2007. The facial skin photograph of each participant was analyzed a total of six times in two days using DM-3(a facial skin photographing system). The square and counts of skin furrows were also measured for each one. As the statistical method, Pearson's correlation coefficient and repeated measured ANOVA were used. Results : The Pearson's correlation coefficient, it showed significantly high correlation in both the square and count of skin furrows for each analysis time. Repeated measured ANOVA showed no significant differences among analyses in both square and count of skin furrows. Conclusions : This study reveales that the measurement of the count and square of facial skin furrows by facial skin photograph analysis has high reproducibility. DM-3(a facial skin photographing system) can be useful for the evaluation of facial skin furrows in facial cosmetic acupuncture.

  • PDF

Restoration of the Broken Lumbopelvic-hip Neuromuscular Chain and Coordinated Synergistic Activation in Low Back Pain

  • Park, Haeun;Park, Chanhee;You, Joshua (Sung) Hyun
    • Physical Therapy Korea
    • /
    • v.29 no.3
    • /
    • pp.215-224
    • /
    • 2022
  • Background: The presence of the lumbopelvic-hip neuromuscular chain is essential for dynamic spinal stabilization; its therapeutic effects on dynamic movements of the distal extremity segment and underpinning motor mechanism remain unknown and warrant further study on participants with low back pain (LBP). Objects: We aim to compare the effects of the broken chain exercise (BCE) and connected chain exercise (CCE) on electromyography (EMG) amplitude and onset time in participants with and without LBP. Methods: Randomized controlled clinical trial. A convenience sample of 40 nonathletic participants (mean age: 24.78 ± 1.70) with and without LBP participated in this study. All participants underwent CCE for 30 minutes, 30-minute daily. We measured EMG amplitude and onset times on bilateral erector spinae (ES), gluteus maximus (GM), hamstring (HAM), transverse abdominis (TrA), internal oblique (IO), and external oblique (EO) during the prone hip extension (PHE) test before and after the BCE and CCE. We used multivariate analysis of variance (MANOVA) to analyze the amplitude and onset time difference between exercises (BCE and CCE) and Pearson's correlations to determine any synergistic relationship among the HAM, GM, bilateral TrA/IO, and ES muscles. The statistical analyses were used at p < 0.05. Results: MANOVA showed that CCE was more decreased on EMG amplitude in HAM and bilateral ES, while increased GM and contralateral TrA/IO than BCE (p < 0.05). MANOVA EMG onset time data analyses revealed that the main effect of the conditions was significant for all HAM, GM, and bilateral ES muscles, whereas the main effect for the group was significant only for GM and contralateral ES in healthy and LBP groups. Pearson's correlation coefficient was computed to assess the relationship between BCE and CCE on dependent variables. In most of the muscles, there was a strong, positive correlation between the two variables, and there was a significant relationship (p < 0.001). Conclusion: CCE produced more effective and coordinated core stabilization and motor control mechanism in the lumbopelvic-hip muscles in participants with and without LBP during PHE than BCE.