• Title/Summary/Keyword: Peak-Current

Search Result 1,759, Processing Time 0.034 seconds

A study on the space charge polarization and electrical conduction in the dielectrics (유전체의 공간전하분극과 전기전도에 관한 연구)

  • 김영근;윤성도;이경섭;국상훈
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1991.10a
    • /
    • pp.79-82
    • /
    • 1991
  • In this paper we examined, by using the PET film with thickness of 16-350$\mu\textrm{m}$, space charge focused on TSC peak at the slightly higher temperature than transition temperture of the glass. In the result we found that charge quantity, leaking current and absorbing current at TSC peak were rarely dependant its thickness at the Al foil contact electrde. In the case of Al evaporated electrode, the absorbing current was rarely dependent its thickness but TSC charge quantity at C-peak was increased directly proportional to its thickness and leaking current was decayed inversely proportional to its thickness. Also current-volteag characteristics showed sublinerar property under ohmic area at the Al evaporated electrode.

Effects of Bay K, cAMP and Isoprenaline on the Na-Ca Exchange Current of Single Rabbit Atrial Cells (토끼 심방근에서 Na-Ca 교환 전류에 대한 Bay K, cAMP, Isoprenaline 효과)

  • Ho, Won-Kyung;Earm, Yung-E
    • The Korean Journal of Physiology
    • /
    • v.24 no.2
    • /
    • pp.377-388
    • /
    • 1990
  • Ca movements during the late plateau phase in rabbit atrium implicate Na-Ca exchange. In single atrial cells isolated from the rabbit the properties of the inward current of Na-Ca exchange were investigated using the whole cell voltage clamp technique. The inward currents were recorded during repolarization following brief 2 ms depolarizing pulse to +40 mV from a holding potential of -70 mV. Followings are the results obtained: 1) When stimulated every 30 sec, the inward currents were activated and reached peak values $6{\sim}12\;ms$ after the beginning of depolarizing pulse. The mean current amplitude was 342 pA/cell. 2) The current decayed spontaneously from the peak activation and the timecourse of the relaxation showed two different phases: fast and slow phase. 3) The recovery of the inward current was tested by paired pulse of various interval. The peak current recovered exponentialy with a time course similar to that of Ca current recovery. 4) Relaxation timecourse was also affected by pulse interval and time constant was reduced almost linearly according to the decrease of pulse interval between 30 sec and 1 sec. 5) The peak inward current was increased by long prepulse stimulation, Bay K, isoprenaline or c-AMP. 6) The relaxation time constant of the inward current was prolonged by Bay K or c-AMP, and shortened by isoprenaline. From the above results, it could be concluded that increase of the calcium current potentiates and prolongs intracellular calcium transients, while shortening of the timecourse by isoprenaline or short interval stimulations might be due to the facilitation of Ca uptake by SR.

  • PDF

Effect of current waveform on drop transfer in pulsed gas metal arc welding (Pulsed GMAW 의 전류 파형이 금속이행에 미치는 영향)

  • Hammad, Muhammad A.;Yoo, Choong-D.
    • Proceedings of the KWS Conference
    • /
    • 2009.11a
    • /
    • pp.48-48
    • /
    • 2009
  • Conventionally in pulsed gas metal arc welding (GMAW-P), drop transfer is analyzed with simplest square pulse waveform. While the pulse current is described by four parameters (peak current magnitude and time plus base current magnitude and time), it deviates the real pulse shape. Real pulse can be better idealized by the trapezoidal pulse waveform described by two additional parameters, i.e., current rise and fall rate (dI/dt). Power source response rate is described by these parameters. In this work, the effect of these parameters on drop transfer is predicted by the force displacement model (FDM). While peak current has significant effects on drop detachment, drop transfer is also influenced by the current rise rate. Predictions indicate that the current rise rate can have considerable effects on the size of the detached drop if other pulse parameters are kept constant. FDM is applied to determine peak time for one drop one pulse condition (ODOP) when rests of the pulse parameters are given. The predicted range of ODOP shows good agreement with experimental data.

  • PDF

Numerical Analysis of Through Transmission Pulsed Eddy Current Testing and Effects of Pulse Width Variation

  • Shin, Young-Kil;Choi, Dong-Myung
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.27 no.3
    • /
    • pp.255-261
    • /
    • 2007
  • By using numerical analysis methods, through transmission type pulsed eddy current (PEC) testing is modeled and PEC signal responses due to varying material conductivity, permeability, thickness, lift-off and pulse width are investigated. Results show that the peak amplitude of PEC signal gets reduced and the time to reach the peak amplitude is increased as the material conductivity, permeability, and specimen thickness increase. Also, they indicate that the pulse width needs to be shorter when evaluating the material conductivity and the plate thickness using the peak amplitude, and when the pulse width is long, the peak time is found to be more useful. Other results related to lift-off variation are reported as well.

The Effects of Lift-Off from Wall Thinning Signal in Pulsed Eddy Current Testing

  • Park, Duck-Gun;Angani, C.S.;Kishore, M.B.;Kim, C.G.;Lee, D.H.
    • Journal of Magnetics
    • /
    • v.17 no.4
    • /
    • pp.298-301
    • /
    • 2012
  • In order to know the effect of surface irregularity in the detection of local wall thinning of pipeline using pulsed eddy current (PEC), the lift-off effects on PEC signal have been investigated. Three kinds of parameters in the PEC signal, which is "peak amplitude", "time to peak amplitude" and "time to zero crossing" are analyzed to separate the lift-off effects in the PEC signal. The distance from sensor to the bottom of sample which is the total thickness of combined insulator and sample is kept constant. The magnitude of the differential peak amplitude is increased with increasing sample thickness, the time to peak amplitude is increased with increasing the sample thickness. To determine the effect of lift-off, a number of balanced transient responses combining wall thinning locations and lift-off distances were plotted.

Analysis and Experiment of Peak Current Controlled Buck LED Driver

  • Kim, Marn-Go;Jung, Young-Seok
    • Proceedings of the KIPE Conference
    • /
    • 2011.07a
    • /
    • pp.68-69
    • /
    • 2011
  • Realistic amounts of time delay are found to have significant effects on the average output LED current and on the critical inductor value at the boundary between the two conduction modes. Especially, the time delay can provide an accurate LED current for the peak current controlled (PCC) buck converter with a wide input voltage. Experimental results are presented for the PCC buck LED driver with constant-frequency controller.

  • PDF

Study on Transient Current Limiting Operational Characteristics of Transformer Type SFCL with Two Peak Current Limiting Function (두 번의 피크전류제한 기능을 갖는 변압기형 초전도한류기의 과도전류제한 동작 특성 연구)

  • Han, Tae-Hee;Lim, Sung-Hun
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.29 no.8
    • /
    • pp.499-504
    • /
    • 2016
  • In this paper, we analyzed the operational characteristics of the fault current limiting according to the amplitude of the fault current for the transformer type superconducting fault current limiter (SFCL). If the fault current happens, the superconducting element connected to the secondary coil is occurred quench and the fault current is limited. When the larger fault current occurs, the superconducting element connected to the third coil is occurred additional quench and the peak fault current is limited. We found that the fault current can be more effectively controlled through the analysis of the fault current limiting and the short-circuit tests.

A Design of Peak Current-mode DC-DC Buck Converter with ESD Protection Devices (ESD 보호 소자를 탑재한 Peak Current-mode DC-DC Buck Converter)

  • Park, Jun-Soo;Song, Bo-Bae;Yoo, Dae-Yeol;Lee, Joo-Young;Koo, Yong-Seo
    • Journal of IKEEE
    • /
    • v.17 no.1
    • /
    • pp.77-82
    • /
    • 2013
  • In this paper, dc-dc buck converter controled by the peak current-mode pulse-width-modulation (PWM) presented. Based on the small-signal model, we propose the novel methods of the power stage and the systematic stability designs. To improve the reliability and performance, over-temperature and over-current protection circuits have been designed in the dc-dc converter systems. To prevent electrostatic An electrostatic discharge (ESD) protection circuit is proposed. The proposed dc-dc converter circuit exhibits low triggering voltage by using the gate-substrate biasing techniques. Throughout the circuit simulation, it confirms that the proposed ESD protection circuit has lower triggering voltage(4.1V) than that of conventional ggNMOS (8.2V). The circuit simulation is performed by Mathlab and HSPICE programs utilizing the 0.35um BCD (Bipolar-CMOS-DMOS) process parameters.

Grid Peak Power Limiting / Compensation Power Circuit for Power Unit under Dynamic Load Profile Conditions (Dynamic Load Profile 조건의 전원 장치에 있어서 계통 Peak Power 제한/보상 전력 회로)

  • Jeong, Hee-Seong;Park, Do-Il;Lee, Yong-Hwi;Lee, Chang-Hyeon;Rho, Chung-Wook
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.27 no.5
    • /
    • pp.376-383
    • /
    • 2022
  • The improved performance of computer parts, such as graphic card, CPU, and main board, has led to the need for power supplies with a high power output. The dynamic load profile rapidly changes the usage of power consumption depending on load operations, such as PC power and air conditioner. Under dynamic load profile conditions, power consumption can be classified into maximum, normal, and standby power. Several problems arise in the case of maximum power. Peak power is generated at the system power source in the maximum-power situation. Frequent generation of peak power can cause high-frequency problems and reduce the life of high-pressure parts (especially high-pressure capacitors). For example, when a plurality of PCs are used, system overload occurs due to peak power generation and causes problems, such as power failure and increase in electricity bills due to exceeded contract power. To solve this problem, a system peak power limit/compensation power circuit is proposed for a power supply under dynamic load profile conditions. The proposed circuit detects the system current to determine the power situation of the load. When the system current is higher than the set level, the circuit recognizes that the system current generates peak power and compensates for the load power through a converter using a super capacitor as the power source. Thus, the peak power of loads with a dynamic load profile is limited and compensated for, and problems, such as high-frequency issues, are solved. In addition, the life of high-pressure parts is increased.

A Study on the Measurement of the Transformation Fraction of Steel Using an Eddy Current Sensor (와전류 방식에 의한 금속변태율 측정에 관한 연구)

  • Lee, J.R.;Peak, K.N.
    • Proceedings of the KIEE Conference
    • /
    • 1989.11a
    • /
    • pp.325-326
    • /
    • 1989
  • His paper is concerned on the measurement of transformation fraction of steel using an eddy current sensor. Four stainless duplex samples with different transformation fraction are made and electromagnetic characteristics of the samples are measured.

  • PDF