• Title/Summary/Keyword: Peak operation

Search Result 810, Processing Time 0.029 seconds

Cooling Performance of Geothermal Heat Pump Using Surface Water Heat Exchanger (지표수 열교환기 적용 지열 히트펌프 시스템의 냉방 성능)

  • Lim, Hyo Jae;Kong, Hyoung Jin;Sohn, Byonghu
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.29 no.6
    • /
    • pp.316-326
    • /
    • 2017
  • Commercial buildings and institutions are predominantly cooled, thereby dissipating excess heat to a vertical ground heat exchanger (VGHE), than heat extracted over an annual cycle. Surface waters, such as lakes and ponds, provide a cost-effective means of reducing the VGHE length, and in balancing the thermal loads to the ground. This paper presents the measurement and analysis of the cooling performance of ground-coupled heat pump (GCHP) system, using surface water heat exchanger (SWHE) submerged in an artificial pond. In order to measure the performance of the system, we installed monitoring equipment, including sensors, for assessing the temperature and power consumption, after which the operation parameters were determined. The results from the thermal performance test for the SWHE indicate that the temperatures at the outlet of the SWHE and within the pond were affected by outdoor air temperature. In addition, the results reveal similar variation trends on temperatures; however, the peak temperatures of the SWHE were somewhat greater than those of outdoor air, due to the thermal capacity of the pond. Analyzing the cooling performance over the measurement period, the average coefficient of performance (COP) of heat pump was found to be 5.71, while that for the entire system was 2.99.

Effects of Mg and Cu Additions on Superplastic Behavior in MA Aluminum Alloys

  • Han, Chang-Suk;Jin, Sung-Yooun;Bang, Hyo-In
    • Korean Journal of Materials Research
    • /
    • v.28 no.8
    • /
    • pp.435-439
    • /
    • 2018
  • MA Al alloys are examined to determine the effects of alloying of Mg and Cu and rolling on tensile deformation behavior at 748 K over a wide strain rate range($10^{-4}-10^3/s$). A powder metallurgy aluminum alloy produced from mechanically alloyed pure Al powder exhibits only a small elongation-to-failure(${\varepsilon}_f$ < ~50%) in high temperature(748 K) tensile deformation at high strain rates(${\acute{\varepsilon}}=1-10^2/s$). ${\varepsilon}_f$ in MA Al-0.5~4.0Mg alloys increases slightly with Mg content(${\varepsilon}_f={\sim}140%$ at 4 mass%). Combined addition of Mg and Cu(MA Al-1.5%Mg-4.0%Cu) is very effective for the occurrence of superplasticity(${\varepsilon}_f$ > 500%). Warm-rolling(at 393-492 K) tends to raise ${\varepsilon}_f$. Lowering the rolling-temperature is effective for increasing the ductility. The effect is rather weak in MA pure Al and MA Al-Mg alloys, but much larger in the MA Al-1.5%Mg-4.0%Cu alloy. Additions of Mg and Cu and warm-rolling of the alloy cause a remarkable reduction in the logarithm of the peak flow stress at low strain rates (${\acute{\varepsilon}}$< ~1/s) and sharpening of microstructure and smoothening of grain boundaries. Additions of Mg and Cu make the strain rate sensitivity(the m value) larger at high strain rates, and the warm-rolling may make the grain boundary sliding easier with less cavitation. Grain boundary facets are observed on the fracture surface when ${\varepsilon}_f$ is large, indicating the operation of grain boundary sliding to a large extent during superplastic deformation.

Circadian variation of IV PCA use in patients after orthognathic surgery - a retrospective comparative study

  • Park, Sookyung;Chi, Seong In;Seo, Kwang-Suk;Kim, Hyun Jeong
    • Journal of Dental Anesthesia and Pain Medicine
    • /
    • v.15 no.3
    • /
    • pp.141-146
    • /
    • 2015
  • Background: An understanding of the features of postoperative pain is essential for optimal analgesic dosing strategies. Using a visual analogue scale (VAS) score and patient controlled analgesia (PCA) infusion pattern analysis, an anesthesiologist can estimate when and how severely patients suffer from pain. Several reports have been published about circadian changes in the pain threshold. Postoperative pain was analyzed retrospectively in 250 patients who underwent orthognathic surgery. Methods: A total of 250 patients were allocated into two groups according to the time of recovery from anesthesia. Patients in the early group (group E) recovered from anesthesia before 06:00 p.m. Patients in the late group (group L) recovered from anesthesia after 06:00 p.m. All patients received intravenous patient controlled analgesia (IV PCA) at the end of the operation. The VAS score of pain intensity was measured. Self-administration of bolus analgesic from the IV PCA device was also analyzed according to actual time and elapsed time. Results: VAS scores showed no difference between the two groups except 36 hours after recovery from anesthesia. On POD1, there were two peaks for self-administration of bolus analgesics in group L and one peak in the morning for group E. Two peaks each in the morning and in the afternoon were shown in both groups on POD2. Conclusions: Diurnal variance in pain should be considered for effective dosing strategies.

Fabrication and Test of the Three-Phase 6.6 kV Resistive Superconducting Fault Current Limiter Using YBCO Thin Films (YBCO 박막을 이용한 3상 6.6kV 저항형 초전도 한류기 제작 및 시험)

  • Sim J.;Kim H. R.;Park K. B.;Kang J. S.;Lee B. W.;Oh I. S.;Hyun O. B.
    • Progress in Superconductivity and Cryogenics
    • /
    • v.6 no.3
    • /
    • pp.50-55
    • /
    • 2004
  • We fabricated and tested a resistive type superconducting fault current limiter (SFCL) of three-phase 6.6 $kV_{rms}/200 A_{rms}$ rating based on YBCO thin films grown on sapphire substrates with a diameter of 4 inches, Short circuit tests were carried out at a accredited test facility for single line-to- ground faults, phase-to-phase faults and three-phase faults, Each phase of the SFCL was composed of 8${\times}$6 elements connected in series and parallel respectively. Each element was designed to have the rated voltage of 600 $V_{rms}$. A NiCr shunt resistor of 23 Ω was connected to each element for simultaneous quenches. Firstly, single phase-to-ground fault tests were carried out. The SFCL successfully developed the impedance in the circuit within 0.12 msec after fault and controlled the fault current of 10 $kA_{rms} below 816 A_{peak}$ at the first half cycle. In addition, in case of phase-to-phase fault and three- phase fault test. simultaneous quenches among the SFCLs of the phases successfully accomplished. In conclusion. the SFCL showed excellent performance of current limitation upon fault and stable operation regardless of the amplitude of fault currents.

A Numerical Method & Experiments for the Aerodynamic Design of High Performance 2-Stage Axial Flow Fans (고성능 2단 축류송풍기의 공력설계를 위한 수치해석 및 실험에 관한 연구)

  • Cho, Jinsoo;Han, Cheolhui;Cho, Leesang
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.23 no.8
    • /
    • pp.1048-1062
    • /
    • 1999
  • A numerical method and experiments for the aerodynamic design of high performance two-stage axial flow fans was carried out. A vortex ring element method used for the aerodynamic analysis of the propellers was extended to the fan-duct system. Fan Performance and velocity profiles at the fan inlet and outlet are compared with experimental data for the validations of numerical method. Performance test was done based on KS B 6311(testing methods for turbo-fans and blowers). The velocity profile was obtained using a 5-hole pitot tube by the non-nulling method. The two stage axial flow fan configurations for the optimal operation conditions were set by using the experimental results for the single rotating axial flow fan and the single stage axial flow fan. The single rotating axial flow fan showed relatively low efficiency due to the swirl velocities behind rotor exit which produced pressure losses. In contrast, the single stage and the two-stage axial flow fans showed performance improvements due to the swirl velocity reduction by the stator. The peak efficiency of the two stage axial flow fan was improved by 21% and 6%, compared to the single rotating axial flow fan and the single stage axial flow fan, respectively.

A Study on the Economic Analysis of the Energy Storage System in Customer (수용가용 전력저장시스템의 경제성분석에 관한 연구)

  • Kim, Jeongho;Jang, Junoh
    • New & Renewable Energy
    • /
    • v.10 no.3
    • /
    • pp.47-54
    • /
    • 2014
  • Recently, BESS is considered as one of essential countermeasure for demand side management. However, an economic evaluation is critical issue for the introduction of power system because the cost of BESS is very high in present stage. Therefor, this paper presents economic evaluation method for customer use case by considering peak shaving function based on the real time price. From the case study on the model power system and educational customer, it is confirmed that the proposed method is a practical tool for the economic analysis of BESS. and analytical approach for the reliability assessment in radially operated distribution systems. The approach can estimate the expected reliability performance of distribution systems by a direct assessment of the configuration of the systems using the reliability indexes such as NDP (Non-Delivery Power) and NDE (Non-Delivery Energy). The indexes can only consider the number and configuration of the load, but can not consider the characteristics of the load which is the one of the most important factor in the investment cost for the distribution systems. Therefore, this paper presents the new performance indexes for the investment of the distribution facilities considering both the expected interruption cost for the load section and the operation characteristics of Energy Storage System. The results from a case study show that the proposed methods can be a practical tool for the reliability management in distribution systems including Energy Storage System.

Surface Characterization of NF membranes for Hardness Removal and Its Implications to Fouling Mechanisms (경도제거용 나노여과막의 표면 특성 분석 및 막오염기작 연구)

  • Ham, Sangwoo;Kim, Youngjin;Kim, Chunghwan;Shon, Hokyong;Hong, Seungkwan
    • Journal of Korean Society on Water Environment
    • /
    • v.29 no.4
    • /
    • pp.559-567
    • /
    • 2013
  • In recent years, NF (nanofiltration) membrane has been receiving great attention for hardness removal and has begun to replace traditional lime soda ash softening process, particularly in Florida, USA, mainly due to less sludge production and easy operation. This study aimed to provide detailed surface characteristics of various commercial NF membranes by performing sophisticated surface analysis, which would help more fundamentally understand the performance of NF membranes. More specifically, a total of 7 NF membranes from top NF/RO manufacturers in the world were examined for basic performance tests, surface analysis, and fouling potential assessment. The results demonstrated that NF membranes are classified into two groups in terms of surface zeta potential; they are highly negatively charged ones, and neutral and/or less negatively charged ones. Their hydrophobicities, measured by contact angle, varied from hydrophilic to slightly hydrophobic ones. The AFM measurements showed various surface roughness, ranging from 23 nm (smooth) to 162 nm (rough) of average peak height. Lab-scale fouling experiments were performed using feedwater obtained from conventional water treatment plants in the province of Korea, and their results attempted to correlate to surface characteristics of NF membranes. However, unlike typical RO membranes, no clear correlation was found in this study, indicating that fouling mechanisms of NF membrane may be different from those of typical RO membranes, and both cake deposition and pore blocking mechanisms should be considered simultaneously.

Pre- and Postoperative Changes of Serum Levels of Slpha 1-proteinase Inhibitor in Patients with Bronchogenic Cancer (폐암 환자에서의 폐엽절제술 전후의 혈청 Alpha 1-Proteinase Inhibitor의 변화)

  • 이재성
    • Journal of Chest Surgery
    • /
    • v.28 no.3
    • /
    • pp.221-227
    • /
    • 1995
  • Malignancy is one of the several exogenous and endogenous factors that increase serum alpha 1-PI. In fact, serum levels of alpha 1-PI were significantly elevated in the patients with the nonresectable bronchogenic cancer. the purpose of this work was to determine if the immediate postoperative change of serum alpha 1-PI level following tumor resection relates to the patient`s postoperative course. Clinical experimental study was carried out to investigate the postoperative changes of serum alpha 1-PI level following operation for 20 cases of bronchogenic cancer and 10 cases of control, nephrectomy patients Alpha 1-PI concentrations in serum was quantitated by use of radial immunodiffusion technique.The results were as follows ; Preoperative serum level of alpha 1-PI was significantly elevated in patients with bronchogenic cancers [p < 0.001 , when compared to normal control levels. Immediate postoperative serum alpha 1-PI level was significantly increased in patients with bronchogenic cancer [p < 0.05 , but slightly decreased at control groups. The peak serum level of alpha 1-PI was the postoperative three days, and then gradually decreased at the 5, 9, 14 days, but slightly elevated comparing to preoperative alpha 1-PI levels. Serum alpha 1-PI level in patients with adenocarcinoma was elevated, when compared to squamous cell carcinoma, but not significantly. According to the stages of the bronchogenic cancer, each levels of the serum alpha 1-PI were slightly different, but the whole postoperative changes were the general similarity. There were no significant difference in changes of the serum alpha 1-PI level, according to the operative procedures. As the alpha 1-PI is acute reactant, that it was required at the reoperative state of the bronchogenic cancer and rapid response, consumption or requirement were occurred, postoperatively. Therefore, alpha 1-PI can be perioperative indicator for the evaluation of the bronchogenic cancer.

  • PDF

A Feasibility Study on Supplying Stream Minimum Flow Using Detention Storage in Developing Planned District (단지계획지구 홍수저류지의 하천유지유량 공급방안 연구)

  • Noh Jaekyoung;Park Hyun-goo
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2005.05b
    • /
    • pp.1219-1223
    • /
    • 2005
  • This study was accomplished to confirm the possibility of supplying stream minimum flow from detention storage which was determined to reduce peak flows of flood within developing planned district. The results analyzed was summarized as follows; Firstly, Sin-gil district situated in Ansan city was selected, of which watershed area has $0.56km^2$. And detention storage was determined to $5,370m^3$ from analyzing flood volume by the SCS unit hydrograph method. Secondly, using Visual Basic ver 6.0, a detention storage water balance model was developed, in which simulation was based on conditioning storage inflow and outflow according to streamflow volume or rate state. And streamflow was simulated using the DAWAST model. Thirdly, detention operation scenarios were consisted of the combinations with inflow referencing streamflow of 5mm/day, 10mm/day and outflow referencing streamflow of 1mm/day, 2mm/day. The developed detention storage water balance model was operated to simulate daily water storages of detention sized on flood by scenarios. Stream minimum flows were able to be supplied during 209 days to 237 days per a year, total volume of stream minimum flows supplied for this period was analyzed to reach 27 to $55\% of yearly streamflow volume. If inflow criteria of streamflows to detention was considered to be established on a theoretical condition, it is expected to supply stream minimum flows of 20 to $30\% of yearly streamflow from stream to detention. Also to maximize function of supplying urban stream minimum flow from detention storages, sewage waters within developing planned district have to be treated and entered to detention inflow together with streamflows to enrich function of detention planned to reduce flood volumes.

  • PDF

A Research on a Cross Post-Distortion Balanced Linear Power Amplifier for Base-Station (기지국용 Cross Post-Distortion 평형 선형 전력 증폭기에 관한 연구)

  • Choi, Heung-Jae;Jeong, Hee-Young;Jeong, Yong-Chae;Kim, Chul-Dong
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.18 no.11
    • /
    • pp.1262-1270
    • /
    • 2007
  • In this paper, we propose a new distortion cancellation mechanism for a balanced power amplifier structure using the carrier cancellation loop of a feedforward and post-distortion technique. The proposed cross post-distortion balanced linear amplifier can reduce nonlinear components as much as the conventional feedforward amplifier through the output dynamic range and broad bandwidth. Also the proposed system provides higher efficiency than the feedforward. The capacities of power amplifier and error power amplifier in the proposed system are analyzed and compared with those of feedforward amplifier. Also the operation mechanisms of the three kind loops are explained. The proposed cross post-distortion balanced linear power amplifier is implemented at the IMT-2000($f_0=2.14\;GHz$) band. With the commercial high power amplifiers of total power of 240 W peak envelope power fer base-station application, the adjacent channel leakage ratio measurement with wideband code division multiple access 4FA signal shows 18.6 dB improvement at an average output power of 40 dBm. The efficiency of fabricated amplifier Improves about 2 % than the conventional feedforward amplifier.